1.
J Biomech ; 169: 112145, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38761745

RESUMO

To investigate the optimal cutting depth (Cap) in small incision lenticule extraction from the perspective of corneal biomechanics, a three-dimensional finite element model of the cornea was established using a stromal sub-regional material model to simulate small incision lenticule extraction. The displacement difference PΔ at the central point of the posterior corneal surface before and after lenticule extraction, as well as the von Mises stress at four points of different thicknesses in the center of the cornea, were analyzed using the finite element model considering the hyperelastic property and the difference in stiffness between the anterior and posterior of the cornea. The numerical curves of PΔ-Cap and von Mises Stress-Cap relations at different diopters show that the displacement difference PΔ has a smallest value at the same diopter. In this case, the von Mises stress at four points with different thicknesses in the center of the cornea was also minimal. Which means that the optimal cutting depth exsisting in the cornea. Moreover, PΔ-Cap curves for different depth of stromal stiffness boundaries show that the optimal cap thickness would change with the depth of the stromal stiffness boundary. These results are of guiding significance for accurately formulating small incision lenticule extraction surgery plans and contribute to the advancement of research on the biomechanical properties of the cornea.


Assuntos
Córnea , Análise de Elementos Finitos , Modelos Biológicos , Humanos , Córnea/cirurgia , Córnea/fisiologia , Córnea/fisiopatologia , Fenômenos Biomecânicos , Substância Própria/cirurgia , Estresse Mecânico , Cirurgia da Córnea a Laser/métodos , Simulação por Computador
2.
Exp Eye Res ; 236: 109677, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37827443

RESUMO

Lacking specimens is the biggest limitation of studying the mechanical behaviors of human corneal. Extracting stress-strain curves is the crucial step in investigating hyperelastic and anisotropic properties of human cornea. 15 human corneal specimens extracted from the small incision lenticule extraction (SMILE) surgery were applied in this study. To accurately measure the personalized true stress-strain curve using corneal lenticules, the digital image correlation (DIC) method and finite element method were used to calibrate the stress and the strain of the biaxial extension test. The hyperelastic load-displacement curves obtained from the biaxial extension test were performed in preferential fibril orientations, which are arranged along the nasal-temporal (NT) and the superior-inferior (SI) directions within the anterior central stroma. The displacement and strain fields were accurately calibrated and calculated using the digital image correlation (DIC) method. A conversion equation was given to convert the effective engineering strain to the true strain. The stress field distribution, which was simulated using the finite element method, was verified. Based on this, the effective nominal stress with personalized characteristics was calibrated. The personalized stress-strain curves containing individual characteristic, like diopter and anterior surface curvature, was accurately measured in this study. These results provide an experimental method using biaxial tensile test with corneal lenticules. It is the foundation for investigating the hyperelasticity and anisotropy of the central anterior stroma of human cornea.


Assuntos
Córnea , Substância Própria , Humanos , Anisotropia , Calibragem , Análise de Elementos Finitos
3.
J Mech Behav Biomed Mater ; 142: 105802, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37043981

RESUMO

To study the hyperelastic and anisotropic behaviors of the central anterior stroma for patients with myopia, 40 corneal stromal specimens extracted after small incision lenticule extraction (SMILE) surgery were used in the biaxial extension test along two preferential fibril orientations. An improved collagen fibril crimping constitutive model with a specific physical meaning was proposed to analyze the hyperelasticity and anisotropy of the stroma. The effective elastic modulus of the two families of preferentially oriented collagen fibrils and the stiffness of the non-collagenous matrix along all three directions were compared according to the specific physical meaning of the parameters. Anisotropic behavior was found in the hyperelastic properties of the corneal anterior central stroma in the preferential fibril orientations. The stiffness of non-collagenous matrix is significantly larger in the optical axis direction than in the nasal-temporal (NT) and superior-inferior (SI) directions. Moreover, individual differences between males and females slightly impact on hyperelastic and anisotropic behaviors. The differences of these behaviors were significant in the comparison of the left and right eyes. These results have a guiding significance for the accurate design of surgical plans for refractive surgery according to a patient's condition and have a driving value for the further exploration of the biomechanical properties of the whole cornea.


Assuntos
Substância Própria , Miopia , Masculino , Feminino , Humanos , Anisotropia , Substância Própria/cirurgia , Córnea/cirurgia , Córnea/fisiologia , Matriz Extracelular
4.
Biomed Opt Express ; 13(9): 5067-5081, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36187250

RESUMO

This study aimed to investigate the effectiveness of two-photon induced collagen cross-linking (CXL) using femtosecond lasers in human corneal stroma. An 800-nm femtosecond laser optical path for CXL was established. Corneal samples that received two-photon induced CXL and ultraviolet-A (UVA) CXL underwent uniaxial stretching experiments, proteolytic resistance assays and observation of collagen fiber structure changes. Two-photon induced CXL can achieve corneal stiffening effects comparable to UVA CXL and showed better advantages at low strains. The cornea after two-photon induced CXL exhibited high enzymatic resistance and tight collagen fiber arrangement. Two-photon induced CXL promises to be a new option for keratoconus.

5.
Front Bioeng Biotechnol ; 10: 882392, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35669060

RESUMO

Purpose: To investigate the ex vivo elastic modulus of human corneal stroma using tensile testing with optical coherence tomography (OCT) imaging and its correlation with in vivo measurements using corneal visualization Scheimpflug technology. Methods: Twenty-four corneal specimens extracted from stromal lenticules through small incision lenticule extraction were cut into strips for uniaxial tensile tests. In vivo corneal biomechanical responses were evaluated preoperatively using the corneal visualization Scheimpflug technology (CorVis ST). The correlation of the elastic modulus with clinical characteristics and dynamic corneal response parameters were analyzed using Spearman's correlation analysis. Results: The mean low strain tangent modulus (LSTM) of the human corneal stroma was 0.204 ± 0.189 (range 0.010-0.641) MPa, and high strain tangent modulus (HSTM) 5.114 ± 1.958 (range 2.755-9.976) MPa. Both LSTM (r = 0.447, p = 0.029) and HSTM (r = 0.557, p = 0.005) were positively correlated with the stress-strain index (SSI). LSTM was also positively correlated with the A1 deflection length (r = 0.427, p = 0.037) and A1 deflection area (r = 0.441, p = 0.031). HSTM was positively correlated with spherical equivalent (r = 0.425, p = 0.038). Conclusions: The correlation of corneal elastic modulus with A1 deflection parameters and SSI may indicate a relationship between these parameters and tissue elasticity. The HSTM decreased with the degree of myopia. Combining tensile test with OCT may be a promising approach to assess corneal biomechanical properties.

6.
Sensors (Basel) ; 18(2)2018 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-29419782

RESUMO

In this work, we irradiated a high-definition (HD) industrial camera based on a commercial-off-the-shelf (COTS) CMOS image sensor (CIS) with Cobalt-60 gamma-rays. All components of the camera under test were fabricated without radiation hardening, except for the lens. The irradiation experiments of the HD camera under biased conditions were carried out at 1.0, 10.0, 20.0, 50.0 and 100.0 Gy/h. During the experiment, we found that the tested camera showed a remarkable degradation after irradiation and differed in the dose rates. With the increase of dose rate, the same target images become brighter. Under the same dose rate, the radiation effect in bright area is lower than that in dark area. Under different dose rates, the higher the dose rate is, the worse the radiation effect will be in both bright and dark areas. And the standard deviations of bright and dark areas become greater. Furthermore, through the progressive degradation analysis of the captured image, experimental results demonstrate that the attenuation of signal to noise ratio (SNR) versus radiation time is not obvious at the same dose rate, and the degradation is more and more serious with increasing dose rate. Additionally, the decrease rate of SNR at 20.0, 50.0 and 100.0 Gy/h is far greater than that at 1.0 and 10.0 Gy/h. Even so, we confirm that the HD industrial camera is still working at 10.0 Gy/h during the 8 h of measurements, with a moderate decrease of the SNR (5 dB). The work is valuable and can provide suggestion for camera users in the radiation field.

7.
Zhongguo Yi Liao Qi Xie Za Zhi ; 38(2): 79-83, 2014 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-24941766

RESUMO

Integrating physiological parameters measurement into mobile devices is a development tendency of mobile healthcare. Measurement methods for skin moisture and body fat content are studied in this paper. Electrodes are designed for easy integration into mobile devices, and can be embedded in the cover of the mobile phone. Experiments were conducted to obtain a fast and easy measurement method. The results of evaluation show that the measurement system can achieve the same accuracy as commercial products (with correlation above 0.9 and root mean squared error below 4%) in skin moisture and body fat content measurement. Measurement of local-area body fat content showed a nearly linear positive correlation between local-area body fat content and local-area body impedance.


Assuntos
Adiposidade , Aplicativos Móveis , Monitorização Fisiológica/instrumentação , Fenômenos Fisiológicos da Pele , Tecido Adiposo , Humanos , Monitorização Fisiológica/métodos , Dobras Cutâneas