Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
1.
bioRxiv ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-39005369

RESUMO

Accurate quantification of tau binding from 18 F-PI-2620 PET requires kinetic modeling and an input function. Here, we implemented a non-invasive Image-derived input function (IDIF) derived using the state-of-the-art total-body uEXPLORER PET/CT scanner to quantify tau binding and tracer delivery rate from 18 F-PI-2620 in the brain. Additionally, we explored the impact of scan duration on the quantification of kinetic parameters. Total-body PET dynamic data from 15 elderly participants were acquired. Time-activity curves from the grey matter regions of interest (ROIs) were fitted to the two-tissue compartmental model (2TCM) using a subject-specific IDIF derived from the descending aorta. ROI-specific kinetic parameters were estimated for different scan durations ranging from 10 to 90 minutes. Logan graphical analysis was also used to estimate the total distribution volume (V T ). Differences in kinetic parameters were observed between ROIs, including significant reduction in tracer delivery rate (K 1 ) in the medial temporal lobe. All kinetic parameters remained relatively stable after the 60-minute scan window across all ROIs, with K 1 showing high stability after 30 minutes of scan duration. Excellent correlation was observed between V T estimated using 2TCM and Logan plot analysis. This study demonstrated the utility of IDIF with total-body PET in investigating 18 F-PI-2620 kinetics in the brain.

2.
IEEE Trans Image Process ; 33: 4075-4089, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38941203

RESUMO

Combining dual-energy computed tomography (DECT) with positron emission tomography (PET) offers many potential clinical applications but typically requires expensive hardware upgrades or increases radiation doses on PET/CT scanners due to an extra X-ray CT scan. The recent PET-enabled DECT method allows DECT imaging on PET/CT without requiring a second X-ray CT scan. It combines the already existing X-ray CT image with a 511 keV γ -ray CT (gCT) image reconstructed from time-of-flight PET emission data. A kernelized framework has been developed for reconstructing gCT image but this method has not fully exploited the potential of prior knowledge. Use of deep neural networks may explore the power of deep learning in this application. However, common approaches require a large database for training, which is impractical for a new imaging method like PET-enabled DECT. Here, we propose a single-subject method by using neural-network representation as a deep coefficient prior to improving gCT image reconstruction without population-based pre-training. The resulting optimization problem becomes the tomographic estimation of nonlinear neural-network parameters from gCT projection data. This complicated problem can be efficiently solved by utilizing the optimization transfer strategy with quadratic surrogates. Each iteration of the proposed neural optimization transfer algorithm includes: PET activity image update; gCT image update; and least-square neural-network learning in the gCT image domain. This algorithm is guaranteed to monotonically increase the data likelihood. Results from computer simulation, real phantom data and real patient data have demonstrated that the proposed method can significantly improve gCT image quality and consequent multi-material decomposition as compared to other methods.


Assuntos
Algoritmos , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Imagens de Fantasmas , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos
3.
Neuroimage ; 293: 120611, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38643890

RESUMO

Dynamic PET allows quantification of physiological parameters through tracer kinetic modeling. For dynamic imaging of brain or head and neck cancer on conventional PET scanners with a short axial field of view, the image-derived input function (ID-IF) from intracranial blood vessels such as the carotid artery (CA) suffers from severe partial volume effects. Alternatively, optimization-derived input function (OD-IF) by the simultaneous estimation (SIME) method does not rely on an ID-IF but derives the input function directly from the data. However, the optimization problem is often highly ill-posed. We proposed a new method that combines the ideas of OD-IF and ID-IF together through a kernel framework. While evaluation of such a method is challenging in human subjects, we used the uEXPLORER total-body PET system that covers major blood pools to provide a reference for validation. METHODS: The conventional SIME approach estimates an input function using a joint estimation together with kinetic parameters by fitting time activity curves from multiple regions of interests (ROIs). The input function is commonly parameterized with a highly nonlinear model which is difficult to estimate. The proposed kernel SIME method exploits the CA ID-IF as a priori information via a kernel representation to stabilize the SIME approach. The unknown parameters are linear and thus easier to estimate. The proposed method was evaluated using 18F-fluorodeoxyglucose studies with both computer simulations and 20 human-subject scans acquired on the uEXPLORER scanner. The effect of the number of ROIs on kernel SIME was also explored. RESULTS: The estimated OD-IF by kernel SIME showed a good match with the reference input function and provided more accurate estimation of kinetic parameters for both simulation and human-subject data. The kernel SIME led to the highest correlation coefficient (R = 0.97) and the lowest mean absolute error (MAE = 10.5 %) compared to using the CA ID-IF (R = 0.86, MAE = 108.2 %) and conventional SIME (R = 0.57, MAE = 78.7 %) in the human-subject evaluation. Adding more ROIs improved the overall performance of the kernel SIME method. CONCLUSION: The proposed kernel SIME method shows promise to provide an accurate estimation of the blood input function and kinetic parameters for brain PET parametric imaging.


Assuntos
Encéfalo , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Tomografia por Emissão de Pósitrons/normas , Encéfalo/diagnóstico por imagem , Imagem Corporal Total/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
4.
J Nucl Med ; 65(5): 714-721, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548347

RESUMO

The lungs are supplied by both the pulmonary arteries carrying deoxygenated blood originating from the right ventricle and the bronchial arteries carrying oxygenated blood downstream from the left ventricle. However, this effect of dual blood supply has never been investigated using PET, partially because the temporal resolution of conventional dynamic PET scans is limited. The advent of PET scanners with a long axial field of view, such as the uEXPLORER total-body PET/CT system, permits dynamic imaging with high temporal resolution (HTR). In this work, we modeled the dual-blood input function (DBIF) and studied its impact on the kinetic quantification of normal lung tissue and lung tumors using HTR dynamic PET imaging. Methods: Thirteen healthy subjects and 6 cancer subjects with lung tumors underwent a dynamic 18F-FDG scan with the uEXPLORER for 1 h. Data were reconstructed into dynamic frames of 1 s in the early phase. Regional time-activity curves of lung tissue and tumors were analyzed using a 2-tissue compartmental model with 3 different input functions: the right ventricle input function, left ventricle input function, and proposed DBIF, all with time delay and dispersion corrections. These models were compared for time-activity curve fitting quality using the corrected Akaike information criterion and for differentiating lung tumors from lung tissue using the Mann-Whitney U test. Voxelwise multiparametric images by the DBIF model were further generated to verify the regional kinetic analysis. Results: The effect of dual blood supply was pronounced in the high-temporal-resolution time-activity curves of lung tumors. The DBIF model achieved better time-activity curve fitting than the other 2 single-input models according to the corrected Akaike information criterion. The estimated fraction of left ventricle input was low in normal lung tissue of healthy subjects but much higher in lung tumors (∼0.04 vs. ∼0.3, P < 0.0003). The DBIF model also showed better robustness in the difference in 18F-FDG net influx rate [Formula: see text] and delivery rate [Formula: see text] between lung tumors and normal lung tissue. Multiparametric imaging with the DBIF model further confirmed the differences in tracer kinetics between normal lung tissue and lung tumors. Conclusion: The effect of dual blood supply in the lungs was demonstrated using HTR dynamic imaging and compartmental modeling with the proposed DBIF model. The effect was small in lung tissue but nonnegligible in lung tumors. HTR dynamic imaging with total-body PET can offer a sensitive tool for investigating lung diseases.


Assuntos
Neoplasias Pulmonares , Tomografia por Emissão de Pósitrons , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/metabolismo , Masculino , Feminino , Pessoa de Meia-Idade , Cinética , Tomografia por Emissão de Pósitrons/métodos , Modelos Biológicos , Adulto , Fluordesoxiglucose F18 , Idoso , Imagem Corporal Total , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Processamento de Imagem Assistida por Computador , Fatores de Tempo , Compostos Radiofarmacêuticos/farmacocinética
5.
IEEE Trans Radiat Plasma Med Sci ; 8(2): 113-137, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38476981

RESUMO

Spectral computed tomography (CT) has recently emerged as an advanced version of medical CT and significantly improves conventional (single-energy) CT. Spectral CT has two main forms: dual-energy computed tomography (DECT) and photon-counting computed tomography (PCCT), which offer image improvement, material decomposition, and feature quantification relative to conventional CT. However, the inherent challenges of spectral CT, evidenced by data and image artifacts, remain a bottleneck for clinical applications. To address these problems, machine learning techniques have been widely applied to spectral CT. In this review, we present the state-of-the-art data-driven techniques for spectral CT.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38500666

RESUMO

Dual-energy computed tomography (DECT) enables material decomposition for tissues and produces additional information for PET/CT imaging to potentially improve the characterization of diseases. PET-enabled DECT (PDECT) allows the generation of PET and DECT images simultaneously with a conventional PET/CT scanner without the need for a second x-ray CT scan. In PDECT, high-energy γ-ray CT (GCT) images at 511 keV are obtained from time-of-flight (TOF) PET data and are combined with the existing x-ray CT images to form DECT imaging. We have developed a kernel-based maximum-likelihood attenuation and activity (MLAA) method that uses x-ray CT images as a priori information for noise suppression. However, our previous studies focused on GCT image reconstruction at the PET image resolution which is coarser than the image resolution of the x-ray CT. In this work, we explored the feasibility of generating super-resolution GCT images at the corresponding CT resolution. The study was conducted using both phantom and patient scans acquired with the uEXPLORER total-body PET/CT system. GCT images at the PET resolution with a pixel size of 4.0 mm × 4.0 mm and at the CT resolution with a pixel size of 1.2 mm × 1.2 mm were reconstructed using both the standard MLAA and kernel MLAA methods. The results indicated that the GCT images at the CT resolution had sharper edges and revealed more structural details compared to the images reconstructed at the PET resolution. Furthermore, images from the kernel MLAA method showed substantially improved image quality compared to those obtained with the standard MLAA method.

7.
BMC Nephrol ; 25(1): 117, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38553732

RESUMO

BACKGROUND: Relationship between serum phosphorus time in range and mortality risk in peritoneal dialysis (PD) patients remains uncertain. We aimed to evaluate the association between serum phosphorus time in range and all-cause mortality in Chinese PD population. METHODS: This was a multicenter, retrospective, cohort study of 1,915 patients collected from January 2008 to October 2020 in 4 Chinese centers. Serum phosphorus time in range was estimated as the months during the first year that a patient's serum phosphorus level was within the target range (defined as 1.13-1.78 mmol/L). The primary outcome was all-cause mortality. The secondary outcomes were cardiovascular (CV) mortality and PD withdrawal. Cox proportional hazards regression model with comprehensive adjustments was used to assess the association. RESULTS: The primary outcome occurred in 249 (13.0%) PD patients over a median follow-up of 28 months. Overall, the serum phosphorus time in range was negatively associated with all-cause mortality (per 3-month increments, adjusted HR [aHR], 0.83; 95%CI: 0.75-0.92), CV mortality (per 3-month increments, aHR, 0.87; 95%CI: 0.77-0.99), and PD withdrawal (per 3-month increments, aHR, 0.89; 95%CI: 0.83-0.95). Competing-risk model showed that the relationship of serum phosphorus time in range with all-cause mortality remained stable. None of the variables including demographics, history of diabetes and CV disease, as well as several PD-related and clinical indicators modified this association. CONCLUSIONS: PD patients with longer serum phosphorus time in range in the first year was negatively associated with all-cause mortality and CV mortality. Our findings highlight the importance of maintaining serum phosphorus levels within 1.13-1.78 mmol/L for PD patients.


Assuntos
Doenças Cardiovasculares , Diálise Peritoneal , Humanos , Estudos de Coortes , Estudos Retrospectivos , Fósforo , Diálise Peritoneal/efeitos adversos , Modelos de Riscos Proporcionais
8.
ArXiv ; 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38351944

RESUMO

X-ray computed tomography (CT) in PET/CT is commonly operated with a single energy, resulting in a limitation of lacking tissue composition information. Dual-energy (DE) spectral CT enables material decomposition by using two different x-ray energies and may be combined with PET for improved multimodality imaging, but would either require hardware upgrade or increase radiation dose due to the added second x-ray CT scan. Recently proposed PET-enabled DECT method allows dual-energy spectral imaging using a conventional PET/CT scanner without the need for a second x-ray CT scan. A gamma-ray CT (gCT) image at 511 keV can be generated from the existing time-of-flight PET data with the maximum-likelihood attenuation and activity (MLAA) approach and is then combined with the low-energy x-ray CT image to form dual-energy spectral imaging. To improve the image quality of gCT, a kernel MLAA method was further proposed by incorporating x-ray CT as a priori information. The concept of this PET-enabled DECT has been validated using simulation studies, but not yet with 3D real data. In this work, we developed a general open-source implementation for gCT reconstruction from PET data and use this implementation for the first real data validation with both a physical phantom study and a human subject study on a uEXPLORER total-body PET/CT system. These results have demonstrated the feasibility of this method for spectral imaging and material decomposition.

9.
Aesthetic Plast Surg ; 48(7): 1417-1425, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38305924

RESUMO

BACKGROUND: Hyaluronic acid (HA) dermal fillers injection is a common procedure in patients with cosmetic needs. Concomitant pain is a major complaint among patients undergoing HA filler injections. Relevant research is limited and there is no consensus on pain management of dermal filler injection. OBJECTIVES: To assist physicians in determining a more appropriate treatment approach, and to better provide treatment suggestions. METHODS: A nationwide (China) cross-sectional survey was conducted using questionnaires designed for physicians and patients, respectively. A total of 62 semi-structured questionnaires were administered to aesthetic physicians via face-to-face interview, whereas 123 online-based questionnaires were collected from patients who have ever undergone HA treatment. The collected questionnaire information was analyzed using descriptive statistics and content analysis. RESULTS: 42 (67.74%) physicians observed that over 50% of their patients were concerned about pain during injection. 101 (82.11%) of patients were concerned about impending pain ≥5 points (a total score is 10) before injection. For preferred pain relief modalities, 48 (77.42%) physicians would choose a hyaluronic acid dermal filler with lidocaine, and 82 (66.67%) patients would choose anesthetic-containing products. 59 (95.16%) physicians who injected lidocaine-containing hyaluronic acid found patients had a comfortable treatment experience. CONCLUSIONS: Pain management during hyaluronic acid dermal fillers injection is important from both perspectives of physicians and patients. This survey showed that compared with other analgesic methods, lidocaine-containing hyaluronic acid has offered a more satisfying experience. It also provides insights to physicians and patients in pain management. LEVEL OF EVIDENCE V: This journal requires that authors assign a level of evidence to each article. For a full description of these evidence-based medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Técnicas Cosméticas , Preenchedores Dérmicos , Ácido Hialurônico , Manejo da Dor , Humanos , Preenchedores Dérmicos/administração & dosagem , Preenchedores Dérmicos/efeitos adversos , Estudos Transversais , Feminino , Pessoa de Meia-Idade , Adulto , Masculino , Ácido Hialurônico/administração & dosagem , Ácido Hialurônico/efeitos adversos , Manejo da Dor/métodos , Inquéritos e Questionários , China , Medição da Dor , Dor Processual/etiologia , Dor Processual/diagnóstico , Injeções Subcutâneas , Satisfação do Paciente/estatística & dados numéricos
10.
Water Res ; 253: 121287, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38387264

RESUMO

Biological aqua crust (biogenic aqua crust-BAC) is a potentially sustainable solution for metal(loid) bioremediation in global water using solar energy. However, the key geochemical factors and underlying mechanisms shaping microbial communities in BAC remain poorly understood. The current study aimed at determining the in situ metal(loid) distribution and the key geochemical factors related to microbial community structure and metal(loid)-related genes in BAC of a representative Pb/Zn tailing pond. Here we showed that abundant metal(loid)s (e.g. Pb, As) were co-distributed with Mn/Fe-rich minerals (e.g. biogenic Mn oxide, FeOOH) in BAC. Biogenic Mn oxide (i.e. Mn) was the most dominant factor in shaping microbial community structure in BAC and source tailings. Along with the fact that keystone species (e.g. Burkholderiales, Haliscomenobacter) have the potential to promote Mn ion oxidization and particle agglomeration, as well as Mn is highly associated with metal(loid)-related genes, especially genes related to As redox (e.g. arsC, aoxA), and Cd transport (e.g. zipB), biogenic Mn oxides thus effectively enhance metal(loid) remediation by accelerating the formation of organo-mineral aggregates in biofilm-rich BAC system. Our study indicated that biogenic Mn oxides may play essential roles in facilitating in situ metal(loid) bioremediation in BAC of mine drainage.


Assuntos
Compostos de Manganês , Metais Pesados , Microbiota , Manganês , Chumbo , Bactérias/genética , Óxidos , Minerais
11.
ArXiv ; 2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-37461421

RESUMO

Spectral computed tomography (CT) has recently emerged as an advanced version of medical CT and significantly improves conventional (single-energy) CT. Spectral CT has two main forms: dual-energy computed tomography (DECT) and photon-counting computed tomography (PCCT), which offer image improvement, material decomposition, and feature quantification relative to conventional CT. However, the inherent challenges of spectral CT, evidenced by data and image artifacts, remain a bottleneck for clinical applications. To address these problems, machine learning techniques have been widely applied to spectral CT. In this review, we present the state-of-the-art data-driven techniques for spectral CT.

12.
Int J Surg ; 110(3): 1637-1644, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38079604

RESUMO

BACKGROUND: There are challenges for beginners to identify standard biliopancreatic system anatomical sites on endoscopic ultrasonography (EUS) images. Therefore, the authors aimed to develop a convolutional neural network (CNN)-based model to identify standard biliopancreatic system anatomical sites on EUS images. METHODS: The standard anatomical structures of the gastric and duodenal regions observed by EUS was divided into 14 sites. The authors used 6230 EUS images with standard anatomical sites selected from 1812 patients to train the CNN model, and then tested its diagnostic performance both in internal and external validations. Internal validation set tests were performed on 1569 EUS images of 47 patients from two centers. Externally validated datasets were retrospectively collected from 16 centers, and finally 131 patients with 85 322 EUS images were included. In the external validation, all EUS images were read by CNN model, beginners, and experts, respectively. The final decision made by the experts was considered as the gold standard, and the diagnostic performance between CNN model and beginners were compared. RESULTS: In the internal test cohort, the accuracy of CNN model was 92.1-100.0% for 14 standard anatomical sites. In the external test cohort, the sensitivity and specificity of CNN model were 89.45-99.92% and 93.35-99.79%, respectively. Compared with beginners, CNN model had higher sensitivity and specificity for 11 sites, and was in good agreement with the experts (Kappa values 0.84-0.98). CONCLUSIONS: The authors developed a CNN-based model to automatically identify standard anatomical sites on EUS images with excellent diagnostic performance, which may serve as a potentially powerful auxiliary tool in future clinical practice.


Assuntos
Inteligência Artificial , Endossonografia , Humanos , Estudos Retrospectivos , Redes Neurais de Computação , Sensibilidade e Especificidade
13.
Nutr Metab Cardiovasc Dis ; 34(3): 699-705, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38161121

RESUMO

BACKGROUND AND AIM: To date, few studies have investigated the association between dietary manganese intake and the risk of hypertension, so the prospective relationship of dietary manganese intake and new-onset hypertension remains uncertain. We aimed to investigate the association between dietary manganese intake and the risk of new-onset hypertension in the general Chinese population. METHODS AND RESULTS: This prospective cohort study included 12,177 participants who were free of hypertension at baseline from China Health and Nutrition Survey (CHNS). Dietary intake was measured by 3 consecutive 24-h dietary recalls combined with a household food inventory. The study outcome was new-onset hypertension, defined as systolic blood pressure ≥140 mm Hg or diastolic blood pressure ≥90 mm Hg or diagnosed by a physician or under antihypertensive treatment during the follow-up. During a median follow-up duration of 6.1 years, 4269 (44.9 per 1000 person-years) participants developed new-onset hypertension. Overall, there was a positive association between dietary manganese intake and new-onset hypertension. The adjusted HRs (95%CIs) of new-onset hypertension were 1.00 (reference), 0.97 (0.87, 1.08), 1.24 (1.10, 1.39) and 1.75 (1.52, 2.01) across the quartiles of dietary manganese intake, respectively. Accordingly, a significantly higher risk of new-onset hypertension (HR, 1.38; 95%CI: 1.27, 1.50) was found in participants in quartiles 3-4 of dietary manganese intake (≥6.0 mg/day), compared with those in quartiles 1-2 (<6.0 mg/day). CONCLUSIONS: In the general Chinese population, dietary manganese intake was positively associated with the risk of new hypertension, independent of sodium intake and other important covariates.


Assuntos
Hipertensão , Manganês , Humanos , Manganês/efeitos adversos , Estudos Prospectivos , Estudos de Coortes , Hipertensão/induzido quimicamente , Hipertensão/diagnóstico , Hipertensão/epidemiologia , China/epidemiologia
14.
EJNMMI Res ; 13(1): 97, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-37947880

RESUMO

BACKGROUND: The need for arterial blood data in quantitative PET research limits the wider usability of this imaging method in clinical research settings. Image-derived input function (IDIF) approaches have been proposed as a cost-effective and non-invasive alternative to gold-standard arterial sampling. However, this approach comes with its own limitations-partial volume effects and radiometabolite correction among the most important-and varying rates of success, and the use of IDIF for brain PET has been particularly troublesome. MAIN BODY: This paper summarizes the limitations of IDIF methods for quantitative PET imaging and discusses some of the advances that may make IDIF extraction more reliable. The introduction of automated pipelines (both commercial and open-source) for clinical PET scanners is discussed as a way to improve the reliability of IDIF approaches and their utility for quantitative purposes. Survey data gathered from the PET community are then presented to understand whether the field's opinion of the usefulness and validity of IDIF is improving. Finally, as the introduction of next-generation PET scanners with long axial fields of view, ultra-high sensitivity, and improved spatial and temporal resolution, has also brought IDIF methods back into the spotlight, a discussion of the possibilities offered by these state-of-the-art scanners-inclusion of large vessels, less partial volume in small vessels, better description of the full IDIF kinetics, whole-body modeling of radiometabolite production-is included, providing a pathway for future use of IDIF. CONCLUSION: Improvements in PET scanner technology and software for automated IDIF extraction may allow to solve some of the major limitations associated with IDIF, such as partial volume effects and poor temporal sampling, with the exciting potential for accurate estimation of single kinetic rates. Nevertheless, until individualized radiometabolite correction can be performed effectively, IDIF approaches remain confined at best to a few tracers.

15.
Sensors (Basel) ; 23(21)2023 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-37960618

RESUMO

Rubidium laser optically pumped magnetometers (OPMs) are widely used magnetic sensors based on the Zeeman effect, laser pumping, and magnetic resonance principles. They measure the magnetic field by measuring the magnetic resonance signal passing through a rubidium atomic gas cell. The quality of the magnetic resonance signal is a necessary condition for a magnetometer to achieve high sensitivity. In this research, to obtain the best magnetic resonance signal of rubidium laser OPMs in the Earth's magnetic field intensity, the experiment system of rubidium laser OPMs is built with a rubidium atomic gas cell as the core component. The linewidth and amplitude ratio (LAR) of magnetic resonance signals is utilized as the optimization objective function. The magnetic resonance signals of the magnetometer experiment system are experimentally measured for different laser frequencies, radio frequency (RF) intensities, laser powers, and atomic gas cell temperatures in a background magnetic field of 50,765 nT. The experimental results indicate that optimizing these parameters can reduce the LAR by one order of magnitude. This shows that the optimal parameter combination can effectively improve the sensitivity of the magnetometer. The sensitivity defined using the noise spectral density measured under optimal experimental parameters is 1.5 pT/Hz1/2@1 Hz. This work will provide key technical support for rubidium laser OPMs' product development.

16.
ArXiv ; 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37873021

RESUMO

Integrated use of dual-energy computed tomography (DECT) with positron emission tomography (PET) has many potential clinical applications. However, the integration would either require costly hardware upgrade or increase radiation dose on PET/CT scanners due to the need for an additional Xray CT scan. The recently proposed PET-enabled DECT method enables DECT imaging on PET/CT without requiring the second X-ray CT scan. It combines the already-existing low-energy X-ray CT image with a 511 keV {\gamma}-ray CT (gCT) image reconstructed from time-of-flight PET emission data. A kernelized attenuation and activity (KAA) estimation method has been developed for reconstructing the gCT image from PET but the method has not fully exploited the potential of image prior knowledge. In this work, we propose a neural KAA method by using neural network representation as a deep coefficient prior to improve the existing KAA method. The resulting maximum-likelihood neural network-based reconstruction problem can be efficiently solved by utilizing the theory of optimization transfer. Each iteration of the algorithm consists of three modular steps: PET activity image update, gCT image update, and neural-network learning in the image domain. This algorithm is guaranteed to monotonically increase the data likelihood. The results from computer simulation and real phantom data have demonstrated that the proposed neural KAA method can significantly improve gCT image quality and consequent multi-material decomposition as compared to other methods.

17.
medRxiv ; 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37790461

RESUMO

Immunotherapies, especially the checkpoint inhibitors such as anti-PD-1 antibodies, have transformed cancer treatment by enhancing immune system's capability to target and kill cancer cells. However, predicting immunotherapy response remains challenging. 18F-AraG is a molecular imaging tracer targeting activated T cells, which may facilitate therapy response assessment by non-invasive quantification of immune cell activity within tumor microenvironment and elsewhere in the body. The aim of this study was to obtain preliminary data on total-body pharmacokinetics of 18F-AraG, as a potential quantitative biomarker for immune response evaluation. Methods: The study consisted of 90-min total-body dynamic scans of four healthy subjects and one non-small cell lung cancer (NSCLC) patient, scanned before and after anti-PD-1 immunotherapy. Compartmental modeling with Akaike information criterion model selection were employed to analyze tracer kinetics in various organs. Additionally, seven sub-regions of the primary lung tumor and four mediastinal lymph nodes were analyzed. Practical identifiability analysis was performed to assess reliability of kinetic parameter estimation. Correlations of SUVmean, SUVR (tissue-to-blood ratio), and Logan plot slope KLogan with total volume-of-distribution VT were calculated to identify potential surrogates for kinetic modeling. Results: Strong correlations were observed between KLogan and SUVR values with VT, suggesting that they can be used as promising surrogates for VT, especially in organs with low blood-volume fraction. Moreover, the practical identifiability analysis suggests that the dynamic 18F-AraG PET scans could potentially be shortened to 60 minutes, while maintaining quantification accuracy for all organs-of-interest. The study suggests that although 18F-AraG SUV images can provide insights on immune cell distribution, kinetic modeling or graphical analysis methods may be required for accurate quantification of immune response post-therapy. While SUVmean showed variable changes in different sub-regions of the tumor post-therapy, the SUVR, KLogan, and VT showed consistent increasing trends in all analyzed sub-regions of the tumor with high practical identifiability. Conclusion: Our findings highlight the promise of 18F-AraG dynamic imaging as a non-invasive biomarker for quantifying the immune response to immunotherapy in cancer patients. The promising total-body kinetic modeling results also suggest potentially wider applications of the tracer in investigating the role of T cells in the immunopathogenesis of diseases.

18.
J Nucl Med ; 64(11): 1831-1838, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37652544

RESUMO

Tissue perfusion can be affected by physiology or disease. With the advent of total-body PET, quantitative measurement of perfusion across the entire body is possible. [11C]-butanol is a perfusion tracer with a superior extraction fraction compared with [15O]-water and [13N]-ammonia. To develop the methodology for total-body perfusion imaging, a pilot study using [11C]-butanol on the uEXPLORER total-body PET/CT scanner was conducted. Methods: Eight participants (6 healthy volunteers and 2 patients with peripheral vascular disease [PVD]) were injected with a bolus of [11C]-butanol and underwent 30-min dynamic acquisitions. Three healthy volunteers underwent repeat studies at rest (baseline) to assess test-retest reproducibility; 1 volunteer underwent paired rest and cold pressor test (CPT) studies. Changes in perfusion were measured in the paired rest-CPT study. For PVD patients, local changes in perfusion were investigated and correlated with patient medical history. Regional and parametric kinetic analysis methods were developed using a 1-tissue compartment model and leading-edge delay correction. Results: Estimated baseline perfusion values ranged from 0.02 to 1.95 mL·min-1·cm-3 across organs. Test-retest analysis showed that repeat baseline perfusion measurements were highly correlated (slope, 0.99; Pearson r = 0.96, P < 0.001). For the CPT subject, the largest regional increases were in skeletal muscle (psoas, 142%) and the myocardium (64%). One of the PVD patients showed increased collateral vessel growth in the calf because of a peripheral stenosis. Comorbidities including myocardial infarction, hypothyroidism, and renal failure were correlated with variations in organ-specific perfusion. Conclusion: This pilot study demonstrates the ability to obtain reproducible measurements of total-body perfusion using [11C]-butanol. The methods are sensitive to local perturbations in flow because of physiologic stressors and disease.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Butanóis , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Cinética , Projetos Piloto , Imagem de Perfusão/métodos , Perfusão , Circulação Coronária , Imagem de Perfusão do Miocárdio/métodos
19.
J Nucl Med ; 64(11): 1821-1830, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37591539

RESUMO

Conventional whole-body static 18F-FDG PET imaging provides a semiquantitative evaluation of overall glucose metabolism without insight into the specific transport and metabolic steps. Here we demonstrate the ability of total-body multiparametric 18F-FDG PET to quantitatively evaluate glucose metabolism using macroparametric quantification and assess specific glucose delivery and phosphorylation processes using microparametric quantification for studying recovery from coronavirus disease 2019 (COVID-19). Methods: The study included 13 healthy subjects and 12 recovering COVID-19 subjects within 8 wk of confirmed diagnosis. Each subject had a 1-h dynamic 18F-FDG scan on the uEXPLORER total-body PET/CT system. Semiquantitative SUV and the SUV ratio relative to blood (SUVR) were calculated for different organs to measure glucose utilization. Tracer kinetic modeling was performed to quantify the microparametric blood-to-tissue 18F-FDG delivery rate [Formula: see text] and the phosphorylation rate k 3, as well as the macroparametric 18F-FDG net influx rate ([Formula: see text]). Statistical tests were performed to examine differences between healthy subjects and recovering COVID-19 subjects. The effect of COVID-19 vaccination was also investigated. Results: We detected no significant difference in lung SUV but significantly higher lung SUVR and [Formula: see text] in COVID-19 recovery, indicating improved sensitivity of kinetic quantification for detecting the difference in glucose metabolism. A significant difference was also observed in the lungs with the phosphorylation rate k 3 but not with [Formula: see text], which suggests that glucose phosphorylation, rather than glucose delivery, drives the observed difference of glucose metabolism. Meanwhile, there was no or little difference in bone marrow 18F-FDG metabolism measured with SUV, SUVR, and [Formula: see text] but a significantly higher bone marrow [Formula: see text] in the COVID-19 group, suggesting a difference in glucose delivery. Vaccinated COVID-19 subjects had a lower lung [Formula: see text] and a higher spleen [Formula: see text] than unvaccinated COVID-19 subjects. Conclusion: Higher lung glucose metabolism and bone marrow glucose delivery were observed with total-body multiparametric 18F-FDG PET in recovering COVID-19 subjects than in healthy subjects, implying continued inflammation during recovery. Vaccination demonstrated potential protection effects. Total-body multiparametric PET of 18F-FDG can provide a more sensitive tool and more insights than conventional whole-body static 18F-FDG imaging to evaluate metabolic changes in systemic diseases such as COVID-19.


Assuntos
COVID-19 , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Vacinas contra COVID-19 , COVID-19/diagnóstico por imagem , Glucose , Tomografia por Emissão de Pósitrons/métodos
20.
J Econ Entomol ; 116(5): 1838-1849, 2023 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-37459048

RESUMO

Detection of sex pheromones of insects relies on the antennae. The female pheromone signal transmission in the male antennae ultimately initiates the courtship and mating behaviors of males. To investigate the proteins and metabolites involved in this neural transduction, integrative proteomics and metabolomics analysis including tandem mass tag (TMT) proteomic quantification and liquid chromatography tandem mass spectrometry (LC/MS)-based metabolomics was adopted for comparing proteomic and metabolic changes between the antennae of male moths following stimulation by females and the non-stimulated males of Antheraea pernyi (Guérin-Méneville, Lepidoptera: Saturniidae) in this study. A total of 92 differentially expressed proteins (DEPs) containing 52 upregulated and 40 downregulated proteins and 545 differentially expressed metabolites (DEMs) including 218 upregulated and 327 downregulated metabolites were identified from the antennae of female-stimulated male moths based on the proteome and metabolome data, respectively. Bioinformatics analysis was performed for the 45 DEPs and 160 DEMs, including Gene Ontology (GO), Clusters of Orthologous Groups (COG), and Kyoto Encylopaedia of Genes and Genomes (KEGG) enrichment analysis and Human Metabolome Database (HMDB) annotation. A number of DEPs and DEMs related to neural transmission of female pheromone signals in the male antennae of A. pernyi were screened, including tyrosine hydroxylase, cryptochrome-1, tachykinin, arylalkylamine N-acetyltransferase, cadherin-23, glutathione S-transferase delta 3, tyramine, tryptamine, n-oleoyl dopamine, n-stearoyl dopamine, and n-stearoyl tyrosine. The altered expression levels of those proteins or metabolites were speculated involved in regulating the neuron activity for enhanced transmission of neural impulses and continuous perception, reception, and transduction of female pheromone signals. Our findings yielded novel insights into the potential mechanisms in the antennae of male A. pernyi responding to female attraction.


Assuntos
Mariposas , Masculino , Feminino , Humanos , Animais , Mariposas/fisiologia , Dopamina/metabolismo , Proteômica , Feromônios
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...