Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Opt Express ; 32(6): 8778-8790, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38571127

RESUMO

Recent advancements in ptychography have demonstrated the potential of coded ptychography (CP) for high-resolution optical imaging in a lensless configuration. However, CP suffers imaging throughput limitations due to scanning inefficiencies. To address this, we propose what we believe is a novel 'fly-scan' scanning strategy utilizing two eccentric rotating mass (ERM) vibration motors for high-throughput coded ptychographic microscopy. The intrinsic continuity of the 'fly-scan' technique effectively eliminates the scanning overhead typically encountered during data acquisition. Additionally, its randomized scanning trajectory considerably reduces periodic artifacts in image reconstruction. We also developed what we believe to be a novel rolling-shutter distortion correction algorithm to fix the rolling-shutter effects. We built up a low-cost, DIY-made prototype platform and validated our approach with various samples including a resolution target, a quantitative phase target, a thick potato sample and biospecimens. The reported platform may offer a cost-effective and turnkey solution for high-throughput bio-imaging.

2.
Cardiovasc Diagn Ther ; 14(1): 18-28, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38434554

RESUMO

Background: The early safety and efficacy of Castor branch stents have been demonstrated. However, the effect of aortic arch morphology on endovascular therapy remains an unresolved issue. This study aims to assess the impact of aortic arch morphology on the early outcomes of endovascular repair using Castor stent graft in patients who have acute type B aortic dissection involving the left subclavian artery (LSA). Methods: This is a retrospective cohort study. From January 2019 to December 2021, forty-one patients scheduled for thoracic endovascular aortic repair (TEVAR) of TBADs from Beijing Anzhen Hospital were enrolled in this retrospective cohort study and divided into two groups based on the length of the proximal landing zone left common carotid artery-LSA (PLZ LCCA-LSA), specifically the distance between the LCCA and the LSA (group A ≤10 mm and group B >10 mm). The study recorded technical success, mortality and aortic-related post-operative adverse events. Morphological indices were analyzed including the bird-beak configuration. The bird-beak configuration refers to the wedge-shaped gap between the undersurface of the endograft and the lesser curvature of the arch. The relationship between the risk of bird-beak configuration and PLZ was assessed with logistic regression analysis. Meanwhile, the relationship between the risk of aortic-related adverse events and bird-beak configuration was assessed with logistic regression analysis. Follow-up data were analyzed by Kaplan-Meier life table analysis. Results: The study included 41 patients with a mean age of 63.1±9.2 years, of which 80.5% were male. 18 patients from group A and 23 patients from group B were included in the comparative analysis. There were no significant differences in aortic-related adverse events, bird-beak phenomenon and re-intervention between groups A and B in 30-day outcomes. Six-month outcomes: aortic-related adverse events and the bird-beak phenomenon were observed in 11 (26.8%) and 12 (29.3%) patients, respectively. There was a significant difference in the occurrence of aortic-related adverse events (P=0.036) and bird-beak phenomenon (P=0.002) between groups A and B. In comparison to group B, the aortic-related adverse event rate was significantly higher in group A, with event-free rates of 83.3%, 83.3%, and 72.2% at 1, 3, and 6 months, respectively (P=0.020). Multivariable logistic regression analyses revealed that PLZ LCCA-LSA length [odds ratio (OR) 0.79; 95% CI: 0.64 to 0.97; P=0.026] was significantly associated with the occurrence of the bird-beak configuration, and bird-beak (OR 17.19; 95% CI: 2.24 to 131.81; P=0.006) was a significant risk factor for aortic-related adverse events. Conclusions: TEVAR with LSA revascularization has good early outcomes. However, it is more susceptible to aortic adverse events when the PLZ LCCA-LSA is less than 10 mm in length. This should be carefully considered, taking into account the risks and benefits.

3.
Opt Express ; 31(21): 35003-35015, 2023 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-37859242

RESUMO

Conventional multi-height microscopy techniques introduce different object-to-detector distances to obtain multiple measurements for phase retrieval. However, surpassing the diffraction limit imposed by the numerical aperture (NA) of the objective lens remains a challenging task. Here, we report a novel structured modulation multi-height microscopy technique for quantitative high-resolution imaging. In our platform, a thin diffuser is placed in between the sample and the objective lens. By translating the diffuser to different axial positions, a sequence of modulated intensity images is captured for reconstruction. The otherwise inaccessible high-resolution object information can thus be encoded into the optical system for detection. In the construction process, we report a ptychographic phase retrieval algorithm to recover the existing wavefront of the complex object. We validate our approach using a resolution target, a phase target, and various biological samples. We demonstrate a ∼4-fold resolution gain over the diffraction limit. We also demonstrate our approach to achieve a 6.5 mm by 4.3 mm field of view and a half-pitch resolution of 1.2 µm. The reported methodology provides a portable, turnkey solution for quantitative high-resolution imaging with potential applications in disease diagnosis, sample screening, and other fields.

4.
Nat Protoc ; 18(7): 2051-2083, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37248392

RESUMO

First envisioned for determining crystalline structures, ptychography has become a useful imaging tool for microscopists. However, ptychography remains underused by biomedical researchers due to its limited resolution and throughput in the visible light regime. Recent developments of spatial- and Fourier-domain ptychography have successfully addressed these issues and now offer the potential for high-resolution, high-throughput optical imaging with minimal hardware modifications to existing microscopy setups, often providing an excellent trade-off between resolution and field of view inherent to conventional imaging systems, giving biomedical researchers the best of both worlds. Here, we provide extensive information to enable the implementation of ptychography by biomedical researchers in the visible light regime. We first discuss the intrinsic connections between spatial-domain coded ptychography and Fourier ptychography. A step-by-step guide then provides the user instructions for developing both systems with practical examples. In the spatial-domain implementation, we explain how a large-scale, high-performance blood-cell lens can be made at negligible expense. In the Fourier-domain implementation, we explain how adding a low-cost light source to a regular microscope can improve the resolution beyond the limit of the objective lens. The turnkey operation of these setups is suitable for use by professional research laboratories, as well as citizen scientists. Users with basic experience in optics and programming can build the setups within a week. The do-it-yourself nature of the setups also allows these procedures to be implemented in laboratory courses related to Fourier optics, biomedical instrumentation, digital image processing, robotics and capstone projects.


Assuntos
Processamento de Imagem Assistida por Computador , Microscopia , Microscopia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imagem Óptica
5.
Biomed Opt Express ; 14(2): 489-532, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36874495

RESUMO

Ptychography is an enabling microscopy technique for both fundamental and applied sciences. In the past decade, it has become an indispensable imaging tool in most X-ray synchrotrons and national laboratories worldwide. However, ptychography's limited resolution and throughput in the visible light regime have prevented its wide adoption in biomedical research. Recent developments in this technique have resolved these issues and offer turnkey solutions for high-throughput optical imaging with minimum hardware modifications. The demonstrated imaging throughput is now greater than that of a high-end whole slide scanner. In this review, we discuss the basic principle of ptychography and summarize the main milestones of its development. Different ptychographic implementations are categorized into four groups based on their lensless/lens-based configurations and coded-illumination/coded-detection operations. We also highlight the related biomedical applications, including digital pathology, drug screening, urinalysis, blood analysis, cytometric analysis, rare cell screening, cell culture monitoring, cell and tissue imaging in 2D and 3D, polarimetric analysis, among others. Ptychography for high-throughput optical imaging, currently in its early stages, will continue to improve in performance and expand in its applications. We conclude this review article by pointing out several directions for its future development.

6.
Biosens Bioelectron ; 224: 115049, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36623342

RESUMO

Imaging a large number of bio-specimens at high speed is essential for many biomedical applications. The common strategy is to place specimens at different lateral positions and image them sequentially. Here we report a new on-chip imaging strategy, termed depth-multiplexed ptychographic microscopy (DPM), for parallel imaging and sensing at high speed. Different from the common strategy, DPM stacks multiple specimens in the axial direction and images the entire z-stack all at once. In our prototype platform, we modify a low-cost car mirror for programmable steering of the incident laser beam. A blood-coated image sensor is then placed underneath the stacked sample for acquiring the resulting diffraction patterns. With the captured images, we perform blind recovery of the incident beam angle and model different layers of the stacked sample as different coded surfaces for object reconstruction. For in vitro experiment, we demonstrate time-lapse cell culture monitoring by imaging 3 stacked microfluidic channels on the coded sensor. For high-throughput cytometric analysis, we image 5 stacked brain sections with a 205-mm2 field of view in ∼50 s. Cytometric analysis is also performed to quantify the cellular proliferation biomarkers on the slides. The DPM approach adds a new degree of freedom for data multiplexing in microscopy, enabling parallel imaging of multiple specimens using a single detector. The demonstrated 6-mm depth of field is among the longest ones in microscopy imaging. The novel depth-multiplexed configuration also complements the miniaturization provided by microfluidics devices, offering a solution for on-chip sensing and imaging with efficient sample handling.


Assuntos
Técnicas Biossensoriais , Microscopia , Dispositivos Lab-On-A-Chip , Luz , Microfluídica
7.
Opt Lett ; 48(2): 485-488, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36638490

RESUMO

The applications of conventional ptychography are limited by its relatively low resolution and throughput in the visible light regime. The new development of coded ptychography (CP) has addressed these issues and achieved the highest numerical aperture for large-area optical imaging in a lensless configuration. A high-quality reconstruction of CP relies on precise tracking of the coded sensor's positional shifts. The coded layer on the sensor, however, prevents the use of cross correlation analysis for motion tracking. Here we derive and analyze the motion tracking model of CP. A novel, to the best of our knowledge, remote referencing scheme and its subsequent refinement pipeline are developed for blind image acquisition. By using this approach, we can suppress the correlation peak caused by the coded surface and recover the positional shifts with deep sub-pixel accuracy. In contrast with common positional refinement methods, the reported approach can be disentangled from the iterative phase retrieval process and is computationally efficient. It allows blind image acquisition without motion feedback from the scanning process. It also provides a robust and reliable solution for implementing ptychography with high imaging throughput. We validate this approach by performing high-resolution whole slide imaging of bio-specimens.


Assuntos
Luz , Imagem Óptica , Movimento (Física)
8.
Pharm Biol ; 60(1): 1022-1031, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35635784

RESUMO

CONTEXT: Puerarin (Pue) and tanshinone IIA (Tan IIA) are often used in combination in the treatment of cerebrovascular diseases. OBJECTIVE: To investigate the neuroprotective effect and synergic mechanism of Pue-Tan IIA on the treatment of ischaemic stroke (IS). MATERIALS AND METHODS: IS was induced in rats by middle cerebral artery occlusion (MCAO). Rats were intraperitoneally injected with Pue (36 mg/kg), Tan IIA (7.2 mg/kg), or Pue-Tan IIA (36 and 7.2 mg/kg) for five times [30 min before ischaemia, immediately after reperfusion (0 h), 24, 48, and 72 h after reperfusion]. After administration, neurological function assessment and histological changes in the brain were performed. S-100ß and NSE levels were measured to determine the severity of brain injury. Oxidative stress parameters and inflammatory mediators were measured. The proteins involved in Nrf2/ARE signalling pathway were determined by qRT-PCR and western blot. RESULTS: After administration, the neurological function scores, infarct volume, S-100ß, and NSE levels were significantly reduced in MCAO rats, especially with Pue-Tan IIA treatment (p < 0.05). All treatments increased T-AOC, CAT, SOD, and GSH activities and reduced GSSG activity and MDA, TNF-α, IL-6, ICAM-1, and COX-2 levels in MCAO rats. Pue-Tan IIA significantly increased Nrf2 expression in the nucleus (1.81-fold) and decreased its expression in the cytoplasm (0.60-fold). Pue-Tan IIA significantly increased the expressions of HO-1 (1.87-fold) and NQO1 (1.76-fold) and decreased Keap1 expression (0.39-fold). DISCUSSION AND CONCLUSIONS: The combination of Pue and Tan IIA could alleviate ischaemic brain injury by activating Nrf2/ARE signalling pathway, providing an experimental basis for clinical applications.


Assuntos
Abietanos , Lesões Encefálicas , Isquemia Encefálica , AVC Isquêmico , Isoflavonas , Animais , Ratos , Abietanos/farmacologia , Isquemia Encefálica/tratamento farmacológico , Infarto da Artéria Cerebral Média/tratamento farmacológico , AVC Isquêmico/tratamento farmacológico , Isoflavonas/farmacologia , Proteína 1 Associada a ECH Semelhante a Kelch/metabolismo , Fator 2 Relacionado a NF-E2/metabolismo , Subunidade beta da Proteína Ligante de Cálcio S100
9.
Lab Chip ; 22(14): 2657-2670, 2022 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-35583207

RESUMO

The recent advent of whole slide imaging (WSI) systems has moved digital pathology closer to diagnostic applications and clinical practices. Integrating WSI with machine learning promises the growth of this field in upcoming years. Here we report the design and implementation of a handheld, colour-multiplexed, and AI-powered ptychographic whole slide scanner for digital pathology applications. This handheld scanner is built using low-cost and off-the-shelf components, including red, green, and blue laser diodes for sample illumination, a modified stage for programmable sample positioning, and a synchronized image sensor pair for data acquisition. We smear a monolayer of goat blood cells on the main sensor for high-resolution lensless coded ptychographic imaging. The synchronized secondary sensor acts as a non-contact encoder for precisely tracking the absolute object position for ptychographic reconstruction. For WSI, we introduce a new phase-contrast-based focus metric for post-acquisition autofocusing of both stained and unstained specimens. We show that the scanner can resolve the 388-nm linewidth on the resolution target and acquire gigapixel images with a 14 mm × 11 mm area in ∼70 seconds. The imaging performance is validated with regular stained pathology slides, unstained thyroid smears, and malaria-infected blood smears. The deep neural network developed in this study further enables high-throughput cytometric analysis using the recovered complex amplitude. The reported do-it-yourself scanner offers a portable solution to transform the high-end WSI system into one that can be made widely available at a low cost. The capability of high-throughput quantitative phase imaging may also find applications in rapid on-site evaluations.


Assuntos
Ensaios de Triagem em Larga Escala , Processamento de Imagem Assistida por Computador , Microscopia , Inteligência Artificial , Tecnologia Digital , Desenho de Equipamento , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Microscopia/instrumentação , Microscopia/métodos
10.
ACS Sens ; 7(4): 1058-1067, 2022 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-35393855

RESUMO

The Blu-ray drive is an engineering masterpiece that integrates disc rotation, pickup head translation, and three lasers in a compact and portable format. Here, we integrate a blood-coated image sensor with a modified Blu-ray drive for high-throughput cytometric analysis of various biospecimens. In this device, samples are mounted on the rotating Blu-ray disc and illuminated by the built-in lasers from the pickup head. The resulting coherent diffraction patterns are then recorded by the blood-coated image sensor. The rich spatial features of the blood-cell monolayer help down-modulate the object information for sensor detection, thus forming a high-resolution computational biolens with a theoretically unlimited field of view. With the acquired data, we develop a lensless coherent diffraction imaging modality termed rotational ptychography for image reconstruction. We show that our device can resolve the 435 nm line width on the resolution target and has a field of view only limited by the size of the Blu-ray disc. To demonstrate its applications, we perform high-throughput urinalysis by locating disease-related calcium oxalate crystals over the entire microscope slide. We also quantify different types of cells on a blood smear with an acquisition speed of ∼10,000 cells per second. For in vitro experiments, we monitor live bacterial cultures over the entire Petri dish with single-cell resolution. Using biological cells as a computational lens could enable new intriguing imaging devices for point-of-care diagnostics. Modifying a Blu-ray drive with the blood-coated sensor further allows the spread of high-throughput optical microscopy from well-equipped laboratories to citizen scientists worldwide.


Assuntos
Lasers , Microscopia
11.
Biosens Bioelectron ; 196: 113699, 2022 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-34653716

RESUMO

Traditional microbial detection methods often rely on the overall property of microbial cultures and cannot resolve individual growth event at high spatiotemporal resolution. As a result, they require bacteria to grow to confluence and then interpret the results. Here, we demonstrate the application of an integrated ptychographic sensor for lensless cytometric analysis of microbial cultures over a large scale and with high spatiotemporal resolution. The reported device can be placed within a regular incubator or used as a standalone incubating unit for long-term microbial monitoring. For longitudinal study where massive data are acquired at sequential time points, we report a new temporal-similarity constraint to increase the temporal resolution of ptychographic reconstruction by 7-fold. With this strategy, the reported device achieves a centimeter-scale field of view, a half-pitch spatial resolution of 488 nm, and a temporal resolution of 15-s intervals. For the first time, we report the direct observation of bacterial growth in a 15-s interval by tracking the phase wraps of the recovered images, with high phase sensitivity like that in interferometric measurements. We also characterize cell growth via longitudinal dry mass measurement and perform rapid bacterial detection at low concentrations. For drug-screening application, we demonstrate proof-of-concept antibiotic susceptibility testing and perform single-cell analysis of antibiotic-induced filamentation. The combination of high phase sensitivity, high spatiotemporal resolution, and large field of view is unique among existing microscopy techniques. As a quantitative and miniaturized platform, it can improve studies with microorganisms and other biospecimens at resource-limited settings.


Assuntos
Técnicas Biossensoriais , Estudos Longitudinais , Microscopia
12.
Opt Express ; 29(23): 37892-37906, 2021 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-34808853

RESUMO

Ptychography-based lensless on-chip microscopy enables high-throughput imaging by retrieving the missing phase information from intensity measurements. Numerous reconstruction algorithms for ptychography have been proposed, yet only a few incremental algorithms can be extended to lensless on-chip microscopy because of large-scale datasets but limited computational efficiency. In this paper, we propose the use of accelerated proximal gradient methods for blind ptychographic phase retrieval in lensless on-chip microscopy. Incremental gradient approaches are adopted in the reconstruction routine. Our algorithms divide the phase retrieval problem into sub-problems involving the evaluation of proximal operator, stochastic gradient descent, and Wirtinger derivatives. We benchmark the performances of accelerated proximal gradient, extended ptychographic iterative engine, and alternating direction method of multipliers, and discuss their convergence and accuracy in both noisy and noiseless cases. We also validate our algorithms using experimental datasets, where full field of view measurements are captured to recover the high-resolution complex samples. Among these algorithms, accelerated proximal gradient presents the overall best performance regarding accuracy and convergence rate. The proposed methods may find applications in ptychographic reconstruction, especially for cases where a wide field of view and high resolution are desired at the same time.

13.
Indoor Air ; 31(3): 872-886, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33205466

RESUMO

In this study, 30 subjects were exposed to different combinations of air temperature (Ta : 24, 27, and 30°C) and CO2 level (8000, 10 000, and 12 000 ppm) in a high-humidity (RH: 85%) underground climate chamber. Subjective assessments, physiological responses, and cognitive performance were investigated. The results showed that as compared with exposure to Ta  = 24°C, exposure to 30°C at all CO2 levels caused subjects to feel uncomfortably warm and experience stronger odor intensity, while increased mental effort and greater intensity of acute health symptoms were reported. However, no significant effects of Ta on task performance or physiological responses were found. This indicated that subjects had to exert more effort to maintain their performance in an uncomfortably warm environment. Increasing CO2 from 8000 to 12 000 ppm at all Ta caused subjects to report higher rates of headache, fatigue, agitation, and feeling depressed, although the results were statistically significant only at 24 and 27°C. The text typing performance and systolic blood pressure (SBP) decreased significantly at this exposure, whereas diastolic blood pressure (DBP) and thermal discomfort increased significantly. These effects suggest higher arousal/stress. No significant interaction effect of Ta and CO2 concentration on human responses was identified.


Assuntos
Dióxido de Carbono , Exposição Ambiental , Temperatura , Poluição do Ar em Ambientes Fechados , Pressão Sanguínea , Temperatura Alta , Humanos , Umidade , Análise e Desempenho de Tarefas , Ventilação
14.
Opt Lett ; 45(19): 5405-5408, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33001905

RESUMO

Fourier ptychographic microscopy (FPM) is a computational approach geared towards creating high-resolution and large field-of-view images without mechanical scanning. Acquiring color images of histology slides often requires sequential acquisitions with red, green, and blue illuminations. The color reconstructions often suffer from coherent artifacts that are not presented in regular incoherent microscopy images. As a result, it remains a challenge to employ FPM for digital pathology applications, where resolution and color accuracy are of critical importance. Here we report a deep learning approach for performing unsupervised image-to-image translation of FPM reconstructions. A cycle-consistent adversarial network with multiscale structure similarity loss is trained to perform virtual brightfield and fluorescence staining of the recovered FPM images. In the training stage, we feed the network with two sets of unpaired images: (1) monochromatic FPM recovery and (2) color or fluorescence images captured using a regular microscope. In the inference stage, the network takes the FPM input and outputs a virtually stained image with reduced coherent artifacts and improved image quality. We test the approach on various samples with different staining protocols. High-quality color and fluorescence reconstructions validate its effectiveness.

15.
J Biophotonics ; 13(12): e202000227, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32844560

RESUMO

Whole slide imaging (WSI) has moved digital pathology closer to diagnostic practice in recent years. Due to the inherent tissue topography variability, accurate autofocusing remains a critical challenge for WSI and automated microscopy systems. The traditional focus map surveying method is limited in its ability to acquire a high degree of focus points while still maintaining high throughput. Real-time approaches decouple image acquisition from focusing, thus allowing for rapid scanning while maintaining continuous accurate focus. This work reviews the traditional focus map approach and discusses the choice of focus measure for focal plane determination. It also discusses various real-time autofocusing approaches including reflective-based triangulation, confocal pinhole detection, low-coherence interferometry, tilted sensor approach, independent dual sensor scanning, beam splitter array, phase detection, dual-LED illumination and deep-learning approaches. The technical concepts, merits and limitations of these methods are explained and compared to those of a traditional WSI system. This review may provide new insights for the development of high-throughput automated microscopy imaging systems that can be made broadly available and utilizable without loss of capacity.


Assuntos
Processamento de Imagem Assistida por Computador , Microscopia
16.
Opt Lett ; 45(13): 3486-3489, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32630878

RESUMO

We report an angle-tilted, wavelength-multiplexed ptychographic modulation approach for multispectral lensless on-chip microscopy. In this approach, we illuminate the specimen with lights at five wavelengths simultaneously. A prism is added at the illumination path for spectral dispersion. Thus, lightwaves at different wavelengths hit the specimen at slightly different incident angles, breaking the ambiguities in mixed-state ptychographic reconstruction. At the detection path, we place a thin diffuser between the specimen and the monochromatic image sensor for encoding the spectral information into 2D intensity measurements. By scanning the sample to different x-y positions, we acquire a sequence of monochromatic images for reconstructing the five complex object profiles at the five wavelengths. An up-sampling procedure is integrated into the recovery process to bypass the resolution limit imposed by the imager pixel size. We demonstrate a half-pitch resolution of 0.55 µm using an image sensor with 1.85 µm pixel size. We also demonstrate quantitative and high-quality multispectral reconstructions of stained tissue sections for digital pathology applications.

17.
Artigo em Inglês | MEDLINE | ID: mdl-32190081

RESUMO

Garlic has been proven effective in the prevention and treatment of atherosclerosis (AS), which is widely used as a food and medicine by people in daily life. Garlic saponins are the main active nonsulfur compounds of garlic, which have a variety of pharmacological activities against cardiovascular diseases. In this study, the antiatherosclerosis properties and mechanism of total saponins of garlic (TSG) in rats were explored. The AS animal model was established by a combination of high-fat feeding, intraperitoneal injection of vitamin D3, and ovalbumin-induced inflammation in SD rats. Then, the atherosclerotic rats were gavaged daily by TSG for 4 weeks. Administration of TSG markedly decreased atherosclerotic lesions in the aorta of atherosclerotic rats. TSG restored the serum lipid profile by significantly decreasing the lipid levels and had effective antioxidation by inhibiting the content of malondialdehyde (MDA) and restoring the reduced activity of superoxide dismutase (SOD). Additionally, the ratio of thromboxane B2 (TXB2) and 6-keto-prostaglandin F1α (6-keto-PGF1α ) could be maintained in a relatively stable dynamic balance after administration of TSG to maintain the vascular homeostasis. In summary, TSG had therapeutic effects on AS, which are promising as functional foods or nutraceuticals for the prevention and treatment of AS.

18.
Lab Chip ; 20(6): 1058-1065, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32073018

RESUMO

We report a novel lensless on-chip microscopy platform based on near-field blind ptychographic modulation. In this platform, we place a thin diffuser in between the object and the image sensor for light wave modulation. By blindly scanning the unknown diffuser to different x-y positions, we acquire a sequence of modulated intensity images for quantitative object recovery. Different from previous ptychographic implementations, we employ a unit magnification configuration with a Fresnel number of ∼50 000, which is orders of magnitude higher than those of previous ptychographic setups. The unit magnification configuration allows us to have the entire sensor area, 6.4 mm by 4.6 mm, as the imaging field of view. The ultra-high Fresnel number enables us to directly recover the positional shift of the diffuser in the phase retrieval process, addressing the positioning accuracy issue plaguing regular ptychographic experiments. In our implementation, we use a low-cost, DIY scanning stage to perform blind diffuser modulation. Precise mechanical scanning that is critical in conventional ptychography experiments is no longer needed in our setup. We further employ an up-sampling phase retrieval scheme to bypass the resolution limit set by the imager pixel size and demonstrate a half-pitch resolution of 0.78 µm. We validate the imaging performance via in vitro cell cultures, transparent and stained tissue sections, and a thick biological sample. We show that the recovered quantitative phase map can be used to perform effective cell segmentation of a dense yeast culture. We also demonstrate 3D digital refocusing of the thick biological sample based on the recovered wavefront. The reported platform provides a cost-effective and turnkey solution for large field-of-view, high-resolution, and quantitative on-chip microscopy. It is adaptable for a wide range of point-of-care-, global-health-, and telemedicine-related applications.


Assuntos
Microscopia
19.
Cancer Biol Ther ; 21(4): 332-343, 2020 04 02.
Artigo em Inglês | MEDLINE | ID: mdl-31906826

RESUMO

Gemcitabine (Gem) is currently used as the first-line therapy for liver and pancreatic cancer but has limited efficacy in most cases. Dexamethasone (Dex) have been applied as a chemoprotectant and chemosensitizer in cancer chemotherapy. This study further explored the potential of combination of Gem and Dex and tested the hypothesis that glucocorticoid receptor signaling is essential for the synergistic antitumor activity. In the HepG2 and AsPC-1 xenograft models, the combination treatment showed a significantly synergistic antitumor activity. Immunohistochemistry of post-treatment tumors showed a significant decrease in proliferation and angiogenesis as compared to either of the treatments alone. Dex alone and the combination with Gem inhibited the expression of glucocorticoid receptor. The combination of Dex and Gem showed synergistic cytotoxicity in cell lines in vitro. The antiproliferative synergism is prevented by used glucocorticoid receptor (GR) small interfering RNA, demonstrating that the glucocorticoid receptor is required for the antiproliferative synergism of Gem and Dex. The inhibition of glucocorticoid receptor signaling pathway and induction of apoptosis via activation of caspases 3, 8 and 9, PARP, contributed to the synergistic effect of this combination therapy. These results demonstrate that Dex could potentiate the antitumor efficacy of Gem. The synergistic antitumor activity of the combination of Dex and Gem was through glucocorticoid receptor signaling. Taken together, a combination of Dex and Gem shows a significant synergistic antitumor activity and lesser toxicity both in vitro and in vivo and could be a combination chemotherapy for the treatment of highly expression of glucocorticoid receptor patients.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Carcinoma Hepatocelular/tratamento farmacológico , Sinergismo Farmacológico , Regulação Neoplásica da Expressão Gênica/efeitos dos fármacos , Neoplasias Hepáticas/patologia , Neoplasias Pancreáticas/tratamento farmacológico , Receptores de Glucocorticoides/metabolismo , Animais , Apoptose , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/metabolismo , Carcinoma Hepatocelular/metabolismo , Carcinoma Hepatocelular/patologia , Proliferação de Células , Desoxicitidina/administração & dosagem , Desoxicitidina/análogos & derivados , Dexametasona/administração & dosagem , Feminino , Humanos , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto , Gencitabina
20.
Zhongguo Zhong Yao Za Zhi ; 43(20): 4152-4162, 2018 Oct.
Artigo em Chinês | MEDLINE | ID: mdl-30486544

RESUMO

In this article, we analyze the clinical characteristics of five kinds of traditional Chinese medicine injections in treating heart failure based on Meta-analysis. A total of 24 Meta-analysis papers were included, which involved Shenfu Injection, Shenmai Injection, Shengmai Injection, Danhong Injection and Huangqi Injection. The numbers of literatures of Shenfu Injection, Shenmai Injection and Shengmai Injection are high than the other two injections. The efficiencies of these injections combined with Western medicine are higher than the Western medicine used alone. They can improve 6 minute walk test result, ejection fraction, the level of brain peptide sodium and so on. Shenfu Injection can also improve the living quality of patients' life, heart rate and other indicators. Shenfu Injection can be used for patients with Yin deficiency, while Shenmai Injection can be used for patients with Yin deficiency and Shengmai Injection can be used for patients with Qi and Yin deficiency. From this information, we can see that Western medicine combined with traditional Chinese medicine injections can significantly improve the clinical efficiency. These injections need to be used according to patients' symptom. In the present, as the quality of clinical research literature of traditional Chinese medicine injections is low, the efficiency and safety evaluation of Chinese medicine injections still requires higher level of clinical evidence.


Assuntos
Medicamentos de Ervas Chinesas/uso terapêutico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Injeções , Medicina Tradicional Chinesa , Deficiência da Energia Yin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...