Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Heliyon ; 10(7): e27948, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38571643

RESUMO

Ischemic stroke is a significant burden on human health worldwide. Carotid Atherosclerosis stenosis plays an important role in the comprehensive assessment and prevention of ischemic stroke patients. High-resolution vessel wall magnetic resonance imaging has emerged as a successful technique for assessing carotid atherosclerosis stenosis. This advanced imaging modality has shown promise in effectively displaying a wide range of characteristics associated with the condition, leading to a comprehensive evaluation. High-resolution vessel wall magnetic resonance imaging not only enables a comprehensive evaluation of the instability of carotid atherosclerosis stenosis plaques but also provides valuable information for understanding the pathogenesis and predicting the prognosis of ischemic stroke patients. The purpose of this article is to review the application of high-resolution magnetic resonance imaging in ischemic stroke and carotid atherosclerotic stenosis.

2.
Eur J Med Res ; 28(1): 378, 2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37752519

RESUMO

BACKGROUND AND PURPOSE: Intracranial atherosclerotic stenosis (ICAS) is a major cause of ischemic stroke, and high-resolution vessel wall imaging (HR-VWI) can be used to assess the plaque characteristics of ICAS. This study combined HR-VWI, hemodynamics, and peripheral blood inflammatory indicators to investigate the role of these factors in symptomatic intracranial atherosclerotic stenosis (sICAS) and their inter-relationships. METHODS: Patients diagnosed with atherosclerotic middle cerebral artery stenosis were recruited retrospectively from June 2018 to July 2022. Plaque enhancement was qualitatively and quantitatively analyzed, and the degree of plaque enhancement was graded according to the plaque-to-pituitary stalk contrast ratio (CR). Computational fluid dynamics models were constructed, and then hemodynamic parameters, including wall shear stress (WSS) and pressure ratio (PR), were measured and recorded. Univariate and multivariable analyses were performed to identify factors that can predict sICAS. In addition, the correlation analysis between the plaque characteristics on HR-VWI, hemodynamic parameters, and peripheral blood inflammatory indicators was performed to investigate the interrelationships between these factors. RESULTS: Thirty-two patients were included. A higher proportion of plaque enhancement, maximum WSS, and WSS ratio (WSSR) were significantly associated with sICAS. The multiple logistic regression analysis showed that only the WSSR was an independent risk factor for sICAS. The correlation analysis revealed that both the CR and plaque burden showed linear positive correlation with the WSSR (R = 0.411, P = 0.022; R = 0.474, P = 0.007, respectively), and showed linear negative correlation with the lymphocyte to monocyte ratio (R = 0.382, P = 0.031; R = 0.716, P < 0.001, respectively). CONCLUSIONS: The plaque enhancement and WSSR were significantly associated with sICAS, WSSR was an independent risk factor for sICAS. Plaque enhancement and plaque burden showed linear correlation with the WSSR and lymphocyte-to-monocyte ratio (LMR). Hemodynamics and inflammation combined to promote plaque progression.


Assuntos
Transtornos Cerebrovasculares , Arteriosclerose Intracraniana , AVC Isquêmico , Placa Aterosclerótica , Acidente Vascular Cerebral , Humanos , AVC Isquêmico/complicações , Artéria Cerebral Média/diagnóstico por imagem , Estudos Retrospectivos , Constrição Patológica , Hemodinâmica , Placa Aterosclerótica/complicações , Placa Aterosclerótica/diagnóstico por imagem , Arteriosclerose Intracraniana/complicações , Arteriosclerose Intracraniana/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
3.
Brain Behav ; 13(6): e3032, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37128149

RESUMO

BACKGROUND AND PURPOSE: Intracranial atherosclerotic stenosis (ICAS) is a major cause of ischemic stroke (IS), and high-resolution vessel wall imaging (HR-VWI) can be used to assess the plaque characteristics of ICAS. This study aimed to qualitatively and quantitatively assess plaque enhancement of ICAS and to investigate the relationship between plaque enhancement, plaque morphological features, and IS. METHODS: Data from adult patients with ICAS from April 2018 to July 2022 were retrospectively collected, and all patients underwent HR-VWI examination. Plaque enhancement was qualitatively and quantitatively assessed, and the plaque-to-pituitary stalk contrast ratio (CR) indicated the degree of plaque enhancement. Plaque characteristics, such as plaque burden and area, were quantitatively measured using HR-VWI. Furthermore, receiver-operating characteristic (ROC) analysis was performed to assess the ability of CR to discriminate plaque enhancement. The patients were divided into a symptomatic ICAS group and an asymptomatic ICAS group according to the clinical and imaging characteristics. Univariate and multivariate analyses were performed to investigate which factors were significantly associated with plaque enhancement and symptomatic ICAS. The plaque burden and CR were compared using linear regression. RESULTS: A total of 91 patients with ICAS were enrolled in this study. ICAS plaque burden was significantly associated with plaque enhancement (p = .037), and plaque burden was linearly positively correlated with CR (R = 0.357, p = .001). ROC analysis showed that the cutoff value of CR for plaque enhancement was 0.56 (specificity of 81.8%). Both plaque enhancement and plaque burden were significantly associated with symptomatic ICAS, and only plaque enhancement was an independent risk factor after multivariate analysis. CONCLUSION: Plaque burden was an independent risk factor for plaque enhancement and showed a linear positive correlation with CR. The cutoff value of CR for plaque enhancement was 0.56, and CR ≥ 0.56 was significantly associated with symptomatic ICAS, which was independently associated with plaque enhancement.


Assuntos
Arteriosclerose Intracraniana , Placa Aterosclerótica , Acidente Vascular Cerebral , Adulto , Humanos , Acidente Vascular Cerebral/complicações , Constrição Patológica/complicações , Estudos Retrospectivos , Fatores de Risco , Placa Aterosclerótica/diagnóstico por imagem , Arteriosclerose Intracraniana/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
4.
Taiwan J Ophthalmol ; 12(3): 370-373, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36248073

RESUMO

Ocular surface squamous neoplasia represents neoplastic epithelial abnormalities of conjunctiva and cornea, ranging from squamous dysplasia to invasive squamous cell carcinoma and is both sight- and life-threatening. Squamous spindle cell carcinoma (SSCC) of conjunctiva is a rare variant with distinct behavior which is thought to be more locally aggressive. We describe an 83-year-old woman with a progressively enlarging huge SSCC in her right eye over the past 2 years. The tumor bulged out with local invasion into intraocular and orbital cavities. Wide excision of the tumor with frozen section control was performed. After surgery, topical 0.03% mitomycin C was given as adjuvant therapy. At 40-month follow-up, the lesion site showed no evidence of local recurrence. This case provides a valuable and complete experience of the clinical presentation for the progression and treatment of this rare disease.

5.
Front Immunol ; 13: 915126, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35935982

RESUMO

Background and purpose: Gadolinium enhancement on high-resolution vessel wall imaging (HR-VWI) is an imaging marker of intracranial atherosclerotic stenosis (ICAS) plaque instability. This study aimed to evaluate the relationships between hematological inflammatory indicators and the enhancement of ICAS plaques and to search for hematological indicators that can predict ICAS plaque instability. Methods: Consecutive adult patients diagnosed with ICAS from April 2018 to December 2021 were recruited retrospectively, and every patient underwent HR-VWI. Plaque enhancement was measured qualitatively and quantitatively. The plaque-to-pituitary stalk contrast ratio (CR) indicated the degree of plaque enhancement. Clinical and laboratory data, including the lymphocyte-to-monocyte ratio (LMR), neutrophil-to-lymphocyte ratio (NLR), and systemic immune inflammation index (SII), were recorded. The hematological inflammatory indicators were compared between ICAS patients with and without plaque enhancement and between patients with and without symptomatic plaque. The hematological inflammatory indicators and the CR were compared using linear regression. Furthermore, receiver operating characteristic curve analysis was performed to assess the discriminative abilities of the inflammatory indicators to predict plaque instability. Results: Fifty-nine patients were included. The NLR, SII and LMR were significantly correlated with plaque enhancement. The LMR was independently associated with plaque enhancement, and a linear negative correlation was observed between the LMR and CR (R = 0.716, P < 0.001). The NLR, LMR, plaque enhancement and CR were significantly associated with symptomatic ICAS, and the LMR and plaque enhancement were independent risk factors for symptomatic ICAS. The optimal cutoff value of the admission LMR to distinguish symptomatic plaque from asymptomatic plaque was 4.0 (80.0% sensitivity and 70.6% specificity). Conclusion: The LMR was independently associated with ICAS plaque enhancement and showed a linear negative correlation with CR. The LMR and plaque enhancement were independent risk factors for symptomatic ICAS. An LMR ≤ 4.0 may predict ICAS plaque instability.


Assuntos
Arteriosclerose Intracraniana , Placa Aterosclerótica , Adulto , Constrição Patológica , Meios de Contraste , Gadolínio , Humanos , Arteriosclerose Intracraniana/complicações , Linfócitos , Monócitos , Estudos Retrospectivos
6.
Front Neurol ; 13: 879882, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35669880

RESUMO

Background and Purpose: Neutrophil-lymphocyte ratio (NLR) predicts clinical outcomes in patients with stroke. Aneurysm wall enhancement (AWE) on high-resolution vessel wall magnetic resonance imaging (HR-VWI) is an inflammation marker for intracranial aneurysm (IA). This study aims to evaluate the association of NLR as a peripheral blood inflammatory marker with circumferential AWE in patients with IA. Methods: We analyzed data of consecutive patients harboring IAs between September 2017 and December 2021 at our institution. The peripheral blood inflammatory indicators were compared between patients with ruptured and unruptured IAs. The presence of circumferential AWE in unruptured IA was identified and quantitatively measured using the aneurysm-to-pituitary stalk contrast ratio (CRstalk) on HR-VWI. We used the optimal cutoff value of 0.5 for CRstalk to differentiate circumferential AWE in unruptured IAs. We assessed the relationship of clinical, laboratory, and radiological characteristics with circumferential AWE and CRstalk ≥0.5 in unruptured IAs. Results: The study group was composed of one hundred and twenty-five patients with 142 IAs. NLR level at admission was significantly higher in patients with ruptured IAs than those with unruptured IAs (7.55 vs. 1.81; P < 0.001). AWE on HR-VWI was present in 30 patients with unruptured IAs (38.5%), including 12 with focal AWE and 18 with circumferential AWE. NLR (odds ratio (OR), 2.168; 95% CI, 1.149-4.088) and size (odds ratio, 1.370; 95% CI, 1.126-1.667) were independently associated with circumferential AWE in unruptured IA. NLR was also independently associated with circumferential AWE in small unruptured IA (<7 mm). Furthermore, NLR level at admission was associated with CRstalk ≥.5 in patients with unruptured IA. The optimal cutoff value of NLR for circumferential AWE was 1.86. Conclusion: NLR is a valuable peripheral blood inflammatory marker is more often in the rupture status of IA and was associated with circumferential AWE on HR-VWI in unruptured IA.

7.
Brain Behav ; 12(5): e2568, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35531771

RESUMO

BACKGROUND: Aneurysm wall enhancement on high-resolution vessel wall imaging (HR-VWI) may represent vessel wall inflammation for unruptured intracranial aneurysms (UIAs). Further evidence for the role of circumferential aneurysm wall enhancement (CAWE) in evaluating the instability of UIAs is required, especially in small aneurysms (<7 mm). METHODS: We analyzed patients with saccular UIAs who prospectively underwent HR-VWI on a 3.0 T MRI scanner in our center from September 2017 to August 2021. The presence of AWE was identified and quantitatively measured using the aneurysm-to-pituitary stalk contrast ratio (CRstalk) with maximal signal intensity value. The PHASES and ELAPSS scores were used to assess the risk of aneurysm rupture and growth. We evaluated the association of CAWE and CRstalk value with intracranial aneurysm instability. RESULTS: One hundred patients with 109 saccular UIAs were included in this study. Eighty-three UIAs (76.1%) had a size smaller than 7 mm. PHASES and ELAPSS scores were significantly higher in UIAs with CAWE than in UIAs without CAWE (p < .01). The association of CAWE with PHASES and ELAPSS scores remained in small UIAs (<7 mm). The optimal cutoff value of CRstalk for CAWE was 0.5. PHASES and ELAPSS scores were significantly higher in UIAs with CRstalk ≥0.5 than in UIAs with CRstalk <0.5 (p < .01). CONCLUSIONS: CAWE on HR-VWI is a valuable imaging marker for aneurysm instability in UIAs. CRstalk value ≥0.5 may be associated with a higher risk of intracranial aneurysm rupture and growth.


Assuntos
Aneurisma Roto , Aneurisma Intracraniano , Aneurisma Roto/diagnóstico por imagem , Humanos , Inflamação , Aneurisma Intracraniano/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos
8.
Opt Express ; 30(4): 5255-5264, 2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35209492

RESUMO

In this study, a twisted nematic mode polymer-stabilized liquid crystal (TN mode PSLC) integrated with a crossed polarizer was used to create a transparent waveguide display. When a voltage was applied, the PSLC scattered the waveguide light with a high polarization selectivity such that no substantial loss of the outgoing light intensity was observed after integrating the polarizer. However, with a crossed polarizer, in the ON state, the background light was not only scattered but also absorbed by the analyzer. Using this device configuration, with a 12 µm cell gap and 7% monomer concentration, we successfully realized a normally transparent waveguide display. The contrast ratio of the waveguide outgoing light was 26 and that of the undesired background reached 90. This device can display images due to waveguide edge-lit light scattering and simultaneously block the background information to improve the image quality.

9.
Nanoscale ; 11(21): 10410-10419, 2019 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-31112143

RESUMO

Utilization of light to boost the performance of gas sensors allows us to operate sensor devices at room temperature. Here, we, for the first time, demonstrated an indoor light-activated 3D cone-shaped MoS2 bilayer-based NO gas sensor with ppb-level detection operated at room-temperature. Large-area cone-shaped (CS)-MoS2 bilayers were grown by depositing 2 nm-thick MoO3 layers on a 2'' three-dimensional (3D) cone-patterned sapphire substrate (CPSS) followed by a sulfurization process via chemical vapor deposition. Because the exposed area of MoS2 bilayers is increased by 30%, the CS-MoS2 gas sensor (GS) demonstrated excellent performance with a response of ∼470% and a fast response time of ∼25 s after exposure to 1 ppm of NO gas illuminated by ultraviolet (UV) light with a wavelength of 365 nm. Such extraordinary performance at room temperature is attributed to the enhanced light absorption because of the light scattering effect caused by the 3D configuration and photo-desorption induced by UV illumination. For NO concentrations ranging from 2 ppm down to 0.06 ppm, the CS-MoS2 GS demonstrated a stable sensing behavior with a high response and fast response time (470% and 25 s at 2 ppm NO) because of the light absorption enhanced by the 3D structure and photo-desorption under constant UV illumination. The CS-MoS2 GS exhibits a high sensitivity (∼189.2 R% ppm-1), allowing the detection of NO gas at 0.06 ppm in 130 s. In addition, the 3D cone-shaped structure prolonged the presence of sulfur vapor around MoO3, allowing MoO3 to react with sulfur completely. Furthermore, the CS-MoS2 GS using an indoor lighting to detect NO gas at room temperature was demonstrated for the first time where the CS-MoS2 GS exhibits a stable cycling behavior with a high response (165% at 1 ppm NO) in 50 s; for concentration as low as ∼0.06 ppm, the response of ∼75% in 150 s can be achieved.

10.
Cell Transplant ; 27(12): 1763-1777, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30362372

RESUMO

Non-coding RNAs (ncRNAs) are a class of functional RNAs that regulate gene expression in a post-transcriptional manner. NcRNAs include microRNAs, long non-coding RNAs and circular RNAs. They are highly expressed in the brain and are involved in the regulation of physiological and pathophysiological processes, including cerebral ischemic injury, neurodegeneration, neural development, and plasticity. Stroke is one of the leading causes of death and physical disability worldwide. Acute ischemic stroke (AIS) occurs when brain blood flow stops, and that stoppage results in reduced oxygen and glucose supply to cells in the brain. In this article, we review the latest progress on ncRNAs in relation to their implications in AIS, as well as their potential as diagnostic and prognostic biomarkers. We also review ncRNAs acting as possible therapeutic targets in future precision medicine. Finally, we conclude with a brief discussion of current challenges and future directions for ncRNAs studies in AIS, which may facilitate the translation of ncRNAs research into clinical practice to improve clinical outcome of AIS.


Assuntos
Biomarcadores/metabolismo , RNA não Traduzido/metabolismo , Acidente Vascular Cerebral/patologia , Barreira Hematoencefálica/metabolismo , Isquemia Encefálica/genética , Isquemia Encefálica/patologia , Humanos , Microglia/metabolismo , NF-kappa B/metabolismo , Estresse Oxidativo/genética , Prognóstico , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/genética
11.
Small ; 14(22): e1704052, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29707890

RESUMO

Phase-engineered type-II metal-selenide heterostructures are demonstrated by directly selenizing indium-tin oxide to form multimetal selenides in a single step. The utilization of a plasma system to assist the selenization facilitates a low-temperature process, which results in large-area films with high uniformity. Compared to single-metal-selenide-based photodetectors, the multimetal-selenide photodetectors exhibit obviously improved performance, which can be attributed to the Schottky contact at the interface for tuning the carrier transport, as well as the type-II heterostructure that is beneficial for the separation of the electron-hole pairs. The multimetal-selenide photodetectors exhibit a response to light over a broad spectrum from UV to visible light with a high responsivity of 0.8 A W-1 and an on/off current ratio of up to 102 . Interestingly, all-transparent photodetectors are successfully produced in this work. Moreover, the possibility of fabricating devices on flexible substrates is also demonstrated with sustainable performance, high strain tolerance, and high durability during bending tests.

12.
Small ; 14(19): e1800032, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29635730

RESUMO

The formation of PtSe2 -layered films is reported in a large area by the direct plasma-assisted selenization of Pt films at a low temperature, where temperatures, as low as 100 °C at the applied plasma power of 400 W can be achieved. As the thickness of the Pt film exceeds 5 nm, the PtSe2 -layered film (five monolayers) exhibits a metallic behavior. A clear p-type semiconducting behavior of the PtSe2 -layered film (≈trilayers) is observed with the average field effective mobility of 0.7 cm2 V-1 s-1 from back-gated transistor measurements as the thickness of the Pt film reaches below 2.5 nm. A full PtSe2 field effect transistor is demonstrated where the thinner PtSe2 , exhibiting a semiconducting behavior, is used as the channel material, and the thicker PtSe2 , exhibiting a metallic behavior, is used as an electrode, yielding an ohmic contact. Furthermore, photodetectors using a few PtSe2 -layered films as an adsorption layer synthesized at the low temperature on a flexible substrate exhibit a wide range of absorption and photoresponse with the highest photocurrent of 9 µA under the laser wavelength of 408 nm. In addition, the device can maintain a high photoresponse under a large bending stress and 1000 bending cycles.

13.
ACS Nano ; 11(9): 8768-8776, 2017 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-28753274

RESUMO

Integration of strain engineering of two-dimensional (2D) materials in order to enhance device performance is still a challenge. Here, we successfully demonstrated the thermally strained band gap engineering of transition-metal dichalcogenide bilayers by different thermal expansion coefficients between 2D materials and patterned sapphire structures, where MoS2 bilayers were chosen as the demonstrated materials. In particular, a blue shift in the band gap of the MoS2 bilayers can be tunable, displaying an extraordinary capability to drive electrons toward the electrode under the smaller driven bias, and the results were confirmed by simulation. A model to explain the thermal strain in the MoS2 bilayers during the synthesis was proposed, which enables us to precisely predict the band gap-shifted behaviors on patterned sapphire structures with different angles. Furthermore, photodetectors with enhancement of 286% and 897% based on the strained MoS2 on cone- and pyramid-patterned sapphire substrates were demonstrated, respectively.

14.
Sci Rep ; 7: 42962, 2017 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-28256529

RESUMO

In this research, nano-ring light-emitting diodes (NRLEDs) with different wall width (120 nm, 80 nm and 40 nm) were fabricated by specialized nano-sphere lithography technology. Through the thinned wall, the effective bandgaps of nano-ring LEDs can be precisely tuned by reducing the strain inside the active region. Photoluminescence (PL) and time-resolved PL measurements indicated the lattice-mismatch induced strain inside the active region was relaxed when the wall width is reduced. Through the simulation, we can understand the strain distribution of active region inside NRLEDs. The simulation results not only revealed the exact distribution of strain but also predicted the trend of wavelength-shifted behavior of NRLEDs. Finally, the NRLEDs devices with four-color emission on the same wafer were demonstrated.

15.
Nanoscale Res Lett ; 12(1): 208, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28330186

RESUMO

In this work, aiming at developing a rapid and environmental-friendly process for fabricating CuIn1-x Ga x Se2 (CIGS) solar cells, we demonstrated the one-step selenization process by using selenium vapor as the atmospheric gas instead of the commonly used H2Se gas. The photoluminescence (PL) characteristics indicate that there exists an optimal location with superior crystalline quality in the CIGS thin films obtained by one-step selenization. The energy dispersive spectroscopy (EDS) reveals that the Ga lateral distribution in the one-step selenized CIGS thin film is intimately correlated to the blue-shifted PL spectra. The surface morphologies examined by scanning electron microscope (SEM) further suggested that voids and binary phase commonly existing in CIGS films could be successfully eliminated by the present one-step selenization process. The agglomeration phenomenon attributable to the formation of MoSe2 layer was also observed. Due to the significant microstructural improvement, the current-voltage (J-V) characteristics and external quantum efficiency (EQE) of the devices made of the present CIGS films have exhibited the remarkable carrier transportation characteristics and photon utilization at the optimal location, resulting in a high conversion efficiency of 11.28%. Correlations between the defect states and device performance of the one-step selenized CIGS thin film were convincingly delineated by femtosecond pump-probe spectroscopy.

16.
PLoS One ; 11(11): e0165715, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27802323

RESUMO

Induced pluripotent stem cells (iPSCs) are powerful tools for basic and translational research, as well as regenerative medicine. In routine human in vitro fertilization (IVF) practices, cumulus cells (CCs) are discarded, representing a potential source of biological materials for regenerative medicine. In this study, we derived patient-specific iPSCs using CCs from human infertility clinics for the first time. The human cumulus cell derived iPSCs (hc-iPSCs) were characterized for growth, karyotype, expression of pluripotency genes, and were subjected to embryoid bodies (EBs) and teratoma assays to evaluate their differentiation capacity. Hc-iPSCs display typical iPSC characteristics, and are capable of differentiating into all germ layers in vitro and in vivo. We further show that putative primordial germ cell like cells (PGCLCs) can be derived using hc-iPSCs. Our data demonstrate the feasibility of deriving patient-specific pluripotent stem cells using CCs.


Assuntos
Células do Cúmulo/citologia , Células-Tronco Pluripotentes Induzidas/citologia , Adulto , Diferenciação Celular , Cromossomos Humanos X/genética , Feminino , Regulação da Expressão Gênica , Camadas Germinativas/citologia , Humanos , Células-Tronco Pluripotentes Induzidas/metabolismo
17.
Adv Mater ; 28(44): 9831-9838, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27717140

RESUMO

The necessity for new sources for greener and cleaner energy production to replace the existing ones has been increasingly growing in recent years. Of those new sources, the hydrogen evolution reaction has a large potential. In this work, for the first time, MoSe2 /Mo core-shell 3D-hierarchical nanostructures are created, which are derived from the Mo 3D-hierarchical nanostructures through a low-temperature plasma-assisted selenization process with controlled shapes grown by a glancing angle deposition system.

18.
Opt Express ; 24(17): 19032-9, 2016 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-27557183

RESUMO

This study presents an approach for patterning a polydimethylsiloxane (PDMS) phosphor film with a photonic crystal nano-honeycomb structure on a blue chip package. A phosphor film with a nano-honeycomb structure was patterned and transferred using a nanosphere and used for fabricating remote white light-emitting diodes (w-LEDs). The angular correlated color temperature deviation of the remote phosphor LED could be improved by varying nano-honeycomb structure pitches (450, 750, and 1150 nm). In particular, w-LED samples with excellent color uniformity (ΔCCT ranging from 940 to 440 K) were fabricated from 750-nm w-LED samples with nano-honeycomb-patterned tops.

19.
Sci Rep ; 6: 27471, 2016 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-27273257

RESUMO

Gonadotropin signaling plays an indispensable role in ovarian cancer progression. We previously have demonstrated that thyrostimulin and thyroid-stimulating hormone receptor (TSHR), the most ancient glycoprotein hormone and receptor pair that evolved much earlier than the gonadotropin systems, co-exist in the ovary. However, whether thyrostimulin-driven TSHR activation contributes to ovarian cancer progression in a similar way to gonadotropin receptors has never been explored. In this study, we first found that TSHR is expressed in both rat normal ovarian surface epithelium and human epithelial ovarian cancers (EOCs). Using human NIH:OVCAR-3 as a cell model, we demonstrated that thyrostimulin promotes EOC cell proliferation as strongly as gonadotropins. Thyrostimulin treatment not only activated adenylyl cyclase and the subsequent PKA, MEK-ERK1/2 and PI3K-AKT signal cascades, but also trans-activated EGFR signaling. Signaling dissection using diverse inhibitors indicated that EOC cell proliferation driven by thyrostimulin-TSHR signaling is PKA independent, but does require the involvement of the MEK-ERK and PI3K-AKT signal cascades, which are activated mainly via the trans-activation of EGFR. Thus, not only have we proved that this ancient glycoprotein hormone system is involved in NIH:OVCAR-3 cell proliferation for the first time, but also that it may possibly become a novel oncotarget when studying ovarian cancer.


Assuntos
Proliferação de Células , Receptores ErbB/metabolismo , Glicoproteínas/metabolismo , Neoplasias Ovarianas/metabolismo , Receptores da Tireotropina/metabolismo , Linhagem Celular Tumoral , Feminino , Humanos , Neoplasias Ovarianas/patologia , Transdução de Sinais
20.
Sci Rep ; 6: 23563, 2016 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-27005829

RESUMO

In this study, a novel photoluminescent quantum dots device with laser-processed microscale patterns has been demonstrated to be used as a white light emitting source. The pulsed laser ablation technique was employed to directly fabricate microscale square holes with nano-ripple structures onto the sapphire substrate of a flip-chip blue light-emitting diode, confining sprayed quantum dots into well-defined areas and eliminating the coffee ring effect. The electroluminescence characterizations showed that the white light emission from the developed photoluminescent quantum-dot light-emitting diode exhibits stable emission at different driving currents. With a flexibility of controlling the quantum dots proportions in the patterned square holes, our developed white-light emitting source not only can be employed in the display applications with color triangle enlarged by 47% compared with the NTSC standard, but also provide the great potential in future lighting industry with the correlated color temperature continuously changed in a wide range.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...