Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neural Eng ; 21(4)2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38885673

RESUMO

Objective. The insertion of penetrating neural probes into the brain is crucial for advancing neuroscience, yet it involves various inherent risks. Prototype probes are typically inserted into hydrogel-based brain phantoms and the mechanical responses are analyzed in order to inform the insertion mechanics duringin vivoimplantation. However, the underlying mechanism of the insertion dynamics of neural probes in hydrogel brain phantoms, particularly the phenomenon of cracking, remains insufficiently understood. This knowledge gap leads to misinterpretations and discrepancies when comparing results obtained from phantom studies to those observed under thein vivoconditions. This study aims to elucidate the impact of probe sharpness and dimensions on the cracking mechanisms and insertion dynamics characterized during the insertion of probes in hydrogel phantoms.Approach. The insertion of dummy probes with different shank shapes defined by the tip angle, width, and thickness is systematically studied. The insertion-induced cracks in the transparent hydrogel were accentuated by an immiscible dye, tracked byin situimaging, and the corresponding insertion force was recorded. Three-dimensional finite element analysis models were developed to obtain the contact stress between the probe tip and the phantom.Main results. The findings reveal a dual pattern: for sharp, slender probes, the insertion forces remain consistently low during the insertion process, owing to continuously propagating straight cracks that align with the insertion direction. In contrast, blunt, thick probes induce large forces that increase rapidly with escalating insertion depth, mainly due to the formation of branched crack with a conical cracking surface, and the subsequent internal compression. This interpretation challenges the traditional understanding that neglects the difference in the cracking modes and regards increased frictional force as the sole factor contributing to higher insertion forces. The critical probe sharpness factors separating straight and branched cracking is identified experimentally, and a preliminary explanation of the transition between the two cracking modes is derived from three-dimensional finite element analysis.Significance. This study presents, for the first time, the mechanism underlying two distinct cracking modes during the insertion of neural probes into hydrogel brain phantoms. The correlations between the cracking modes and the insertion force dynamics, as well as the effects of the probe sharpness were established, offering insights into the design of neural probes via phantom studies and informing future investigations into cracking phenomena in brain tissue during probe implantations.


Assuntos
Encéfalo , Hidrogéis , Imagens de Fantasmas , Hidrogéis/química , Encéfalo/fisiologia , Análise de Elementos Finitos , Estresse Mecânico , Eletrodos Implantados
2.
J Biomech ; 160: 111829, 2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37826955

RESUMO

Biaxial mechanical characterizations are the accepted approach to determine the mechanical response of many biological soft tissues. Although several computational and experimental studies have examined how experimental factors (e.g., clamped vs. suture mounting) affect the acquired tissue mechanical behavior, little is known about the role of specimen dimensions in data acquisition and the subsequent modeling. In this study, we combined our established mechanical characterization framework with an iterative size-reduction protocol to test the hypothesis that specimen dimensions affect the observed mechanical behavior of biaxial characterizations. Our findings indicated that there were non-significant differences in the peak equibiaxial stretches of tricuspid valve leaflets across four specimen dimensions ranging from 4.5×4.5mm to 9 × 9mm. Further analyses revealed that there were significant differences in the low-tensile modulus of the circumferential tissue direction. These differences resulted in significantly different constitutive model parameters for the Tong-Fung model between different specimen dimensions of the posterior and septal leaflets. Overall, our findings demonstrate that specimen dimensions play an important role in experimental characterizations, but not necessarily in constitutive modeling of soft tissue mechanical behavior during biaxial testing with the commercial CellScale BioTester.

3.
Nanotechnology ; 30(39): 394002, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31181541

RESUMO

Transient electronics is an emerging technology that enables unique functional transformation or the physical disappearance of electronic devices, and is attracting increasing attention for potential applications in data secured hardware as an ultimate solution against data breaches. Developing smart triggered degradation modalities of silicon (Si) remain the key challenge to achieve advanced non-recoverable on-demand transient electronics. Here, we present a novel electrochemically triggered transience mechanism of Si by lithiation, allowing complete and controllable destruction of Si devices. The depth and microstructure of the lithiation-affected zone over time is investigated in detail and the results suggest a few hours of lithiation is sufficient to create microcracks and significantly promote lithium penetration. Finite element models are proposed to confirm the mechanism. Electrochemically triggered degradation of thin film Si ribbons and Si integrated circuit chips with metal-oxide-semiconductor field-effect transistors from a commercial 0.35 micrometer complementary metal-oxide-semiconductor technology node is performed to demonstrate the potential applications for commercial electronics. This work opens new opportunities for versatile triggered transience of Si-based devices for critical secured information systems and green consumer electronics.

4.
R Soc Open Sci ; 4(8): 170484, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28878995

RESUMO

A generalized solution procedure is developed for in-plane free vibration of rectangular and annular sectorial plates with general boundary conditions. For the annular sectorial plate, the introduction of a logarithmic radial variable simplifies the basic theory and the expression of the total energy. The coordinates, geometric parameters and potential energy for the two different shapes are organized in a unified framework such that a generalized solving procedure becomes feasible. By using the improved Fourier-Ritz approach, the admissible functions are formulated in trigonometric form, which allows the explicit assembly of global mass and stiffness matrices for both rectangular and annular sectorial plates, thereby making the method computationally effective, especially when analysing annular sectorial plates. Moreover, the improved Fourier expansion eliminates the potential discontinuity of the original normal and tangential displacement functions and their derivatives in the entire domain, and accelerates the convergence. The generalized Fourier-Ritz approach for both shapes has the characteristics of generality, accuracy and efficiency. These features are demonstrated via a few numerical examples.

5.
J Appl Mech ; 84(4): 0410021-410026, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28289315

RESUMO

Mechanics of tympanic membrane (TM) is crucial for investigating the acoustic transmission through the ear. In this study, we studied the wrinkling behavior of tympanic membrane when it is exposed to mismatched air pressure between the ambient and the middle ear. The Rayleigh-Ritz method is adopted to analyze the critical wrinkling pressure and the fundamental eigenmode. An approximate analytical solution is obtained and validated by finite element analysis (FEA). The model will be useful in future investigations on how the wrinkling deformation of the TM alters the acoustic transmission function of the ear.

6.
Adv Mater ; 29(8)2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28004863

RESUMO

Scissoring in thick bars suppresses buckling behavior in serpentine traces that have thicknesses greater than their widths, as detailed in a systematic set of analytical and experimental studies. Scissoring in thick copper traces enables elastic stretchability as large as ≈350%, corresponding to a sixfold improvement over previously reported values for thin geometries (≈60%).

7.
Adv Mater ; 28(46): 10257-10265, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27714861

RESUMO

Mechanically reinforced skin-electronics are presented by exploiting networked nanocomposite elastomers where high quality metal nanowires serve as conducting paths. Theoretical and experimental studies show that the established skin-electronics exhibit superior mechanical enhancements against crack and delamination phenomena. Device applications include a class of biomedical devices that offers the ability of thermotherapeutic stimulation and electrophysiological monitoring, all via the skin.

8.
IEEE Trans Compon Packaging Manuf Technol ; 5(9): 1201-1218, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27668126

RESUMO

Mechanical concepts and designs in inorganic circuits for different levels of stretchability are reviewed in this paper, through discussions of the underlying mechanics and material theories, fabrication procedures for the constituent microscale/nanoscale devices, and experimental characterization. All of the designs reported here adopt heterogeneous structures of rigid and brittle inorganic materials on soft and elastic elastomeric substrates, with mechanical design layouts that isolate large deformations to the elastomer, thereby avoiding potentially destructive plastic strains in the brittle materials. The overall stiffnesses of the electronics, their stretchability, and curvilinear shapes can be designed to match the mechanical properties of biological tissues. The result is a class of soft stretchable electronic systems that are compatible with traditional high-performance inorganic semiconductor technologies. These systems afford promising options for applications in portable biomedical and health-monitoring devices. Mechanics theories and modeling play a key role in understanding the underlining physics and optimization of these systems.

9.
Small ; 11(3): 367-73, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25183293

RESUMO

The use of fractal-inspired geometric designs in electrical interconnects represents an important approach to simultaneously achieve large stretchability and high aerial coverage of active devices for stretchable electronics. The elastic stiffness of fractal interconnects is determined analytically in this paper. Specifically, the elastic energy and the tensile stiffness for an order n fractal interconnect of arbitrary shape are obtained, and are verified by the finite element analysis and experiments.

10.
Proc Natl Acad Sci U S A ; 111(36): 12998-3003, 2014 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-25136094

RESUMO

Octopus, squid, cuttlefish, and other cephalopods exhibit exceptional capabilities for visually adapting to or differentiating from the coloration and texture of their surroundings, for the purpose of concealment, communication, predation, and reproduction. Long-standing interest in and emerging understanding of the underlying ultrastructure, physiological control, and photonic interactions has recently led to efforts in the construction of artificial systems that have key attributes found in the skins of these organisms. Despite several promising options in active materials for mimicking biological color tuning, existing routes to integrated systems do not include critical capabilities in distributed sensing and actuation. Research described here represents progress in this direction, demonstrated through the construction, experimental study, and computational modeling of materials, device elements, and integration schemes for cephalopod-inspired flexible sheets that can autonomously sense and adapt to the coloration of their surroundings. These systems combine high-performance, multiplexed arrays of actuators and photodetectors in laminated, multilayer configurations on flexible substrates, with overlaid arrangements of pixelated, color-changing elements. The concepts provide realistic routes to thin sheets that can be conformally wrapped onto solid objects to modulate their visual appearance, with potential relevance to consumer, industrial, and military applications.


Assuntos
Adaptação Ocular , Cefalópodes/anatomia & histologia , Eletrônica/instrumentação , Óptica e Fotônica/instrumentação , Pele/anatomia & histologia , Animais , Cor
11.
Nat Mater ; 13(6): 593-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24776535

RESUMO

Expenses associated with shipping, installation, land, regulatory compliance and on-going maintenance and operations of utility-scale photovoltaics can be significantly reduced by increasing the power conversion efficiency of solar modules through improved materials, device designs and strategies for light management. Single-junction cells have performance constraints defined by their Shockley-Queisser limits. Multi-junction cells can achieve higher efficiencies, but epitaxial and current matching requirements between the single junctions in the devices hinder progress. Mechanical stacking of independent multi-junction cells circumvents these disadvantages. Here we present a fabrication approach for the realization of mechanically assembled multi-junction cells using materials and techniques compatible with large-scale manufacturing. The strategy involves printing-based stacking of microscale solar cells, sol-gel processes for interlayers with advanced optical, electrical and thermal properties, together with unusual packaging techniques, electrical matching networks, and compact ultrahigh-concentration optics. We demonstrate quadruple-junction, four-terminal solar cells with measured efficiencies of 43.9% at concentrations exceeding 1,000 suns, and modules with efficiencies of 36.5%.

12.
Adv Mater ; 25(20): 2773-8, 2013 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-23440975

RESUMO

Materials and designs are presented for electronics and sensors that can be conformally and robustly integrated onto the surface of the skin. A multifunctional device of this type can record various physiological signals relevant to health and wellness. This class of technology offers capabilities in biocompatible, non-invasive measurement that lie beyond those available with conventional, point-contact electrode interfaces to the skin.


Assuntos
Bandagens , Materiais Biocompatíveis/síntese química , Eletrônica/instrumentação , Epiderme/fisiologia , Impressão Molecular/métodos , Nanomedicina/instrumentação , Fenômenos Fisiológicos da Pele , Adulto , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Teste de Materiais , Adulto Jovem
13.
Proc Natl Acad Sci U S A ; 109(49): 19910-5, 2012 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-23150574

RESUMO

Curved surfaces, complex geometries, and time-dynamic deformations of the heart create challenges in establishing intimate, nonconstraining interfaces between cardiac structures and medical devices or surgical tools, particularly over large areas. We constructed large area designs for diagnostic and therapeutic stretchable sensor and actuator webs that conformally wrap the epicardium, establishing robust contact without sutures, mechanical fixtures, tapes, or surgical adhesives. These multifunctional web devices exploit open, mesh layouts and mount on thin, bio-resorbable sheets of silk to facilitate handling in a way that yields, after dissolution, exceptionally low mechanical moduli and thicknesses. In vivo studies in rabbit and pig animal models demonstrate the effectiveness of these device webs for measuring and spatially mapping temperature, electrophysiological signals, strain, and physical contact in sheet and balloon-based systems that also have the potential to deliver energy to perform localized tissue ablation.


Assuntos
Materiais Biocompatíveis , Eletrônica Médica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Coração/fisiologia , Pericárdio/anatomia & histologia , Próteses e Implantes , Animais , Catéteres , Eletrônica Médica/métodos , Desenho de Equipamento/métodos , Coração/anatomia & histologia , Teste de Materiais , Nanotecnologia/métodos , Coelhos , Semicondutores , Seda , Temperatura
15.
Nat Commun ; 3: 916, 2012 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-22735444

RESUMO

The realization of levels of stretchability that extend beyond intrinsic limits of bulk materials is of great importance to stretchable electronics. Here we report large-area, three-dimensional nano-architectures that achieve this outcome in materials that offer both insulating and conductive properties. For the elastomer poly(dimethylsiloxane), such geometries enhance the stretchability and fracture strain by ~62% and ~225% over the bulk, unstructured case. The underlying physics involves local rotations of narrow structural elements in the three-dimensional network, as identified by mechanical modelling. To demonstrate the applications of three-dimensional poly(dimethylsiloxane), we create a stretchable conductor obtained by filling the interstitial regions with liquid metal. This stretchable composite shows extremely high electrical conductivity (~24,100 S cm(-1)) even at strains >200%, with good cyclic properties and with current-carrying capacities that are sufficient for interconnects in light-emitting diode systems. Collectively, these concepts provide new design opportunities for stretchable electronics.


Assuntos
Eletrônica , Nanotecnologia/métodos , Condutividade Elétrica , Nanotecnologia/instrumentação
16.
Science ; 333(6044): 838-43, 2011 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-21836009

RESUMO

We report classes of electronic systems that achieve thicknesses, effective elastic moduli, bending stiffnesses, and areal mass densities matched to the epidermis. Unlike traditional wafer-based technologies, laminating such devices onto the skin leads to conformal contact and adequate adhesion based on van der Waals interactions alone, in a manner that is mechanically invisible to the user. We describe systems incorporating electrophysiological, temperature, and strain sensors, as well as transistors, light-emitting diodes, photodetectors, radio frequency inductors, capacitors, oscillators, and rectifying diodes. Solar cells and wireless coils provide options for power supply. We used this type of technology to measure electrical activity produced by the heart, brain, and skeletal muscles and show that the resulting data contain sufficient information for an unusual type of computer game controller.


Assuntos
Eletrodiagnóstico/instrumentação , Eletrodiagnóstico/métodos , Epiderme , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Semicondutores , Adesividade , Derme , Módulo de Elasticidade , Elastômeros , Fontes de Energia Elétrica , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrodos , Eletroencefalografia/instrumentação , Eletroencefalografia/métodos , Eletromiografia/instrumentação , Eletromiografia/métodos , Humanos , Fenômenos Mecânicos , Nanoestruturas
17.
Small ; 6(7): 851-6, 2010 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-20205199

RESUMO

The fabrication of a hemispherical electronic-eye camera with optimized designs based upon micromechanical analysis is reported. The photodetector arrays combine layouts with multidevice tiles and extended, non-coplanar interconnects to improve the fill factor and deformability, respectively. Quantitative comparison to micromechanics analysis reveals the key features of these designs. Color images collected with working cameras demonstrate the utility of these approaches.


Assuntos
Eletrônica/instrumentação , Fenômenos Mecânicos , Dispositivos Ópticos , Fotografação/instrumentação , Silício/química
18.
Small ; 5(23): 2703-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19866476

RESUMO

Materials and methods to achieve electronics intimately integrated on the surfaces of substrates with complex, curvilinear shapes are described. The approach exploits silicon membranes in circuit mesh structures that can be deformed in controlled ways using thin, elastomeric films. Experimental and theoretical studies of the micromechanics of such curvilinear electronics demonstrate the underlying concepts. Electrical measurements illustrate the high yields that can be obtained. The results represent significant experimental and theoretical advances over recently reported concepts for creating hemispherical photodetectors in electronic eye cameras and for using printable silicon nanoribbons/membranes in flexible electronics. The results might provide practical routes to the integration of high performance electronics with biological tissues and other systems of interest for new applications.


Assuntos
Nanoestruturas/química , Pontos Quânticos , Silício/química , Eletrônica , Microscopia Eletrônica de Varredura , Nanoestruturas/ultraestrutura , Nanotecnologia , Dispositivos Ópticos , Propriedades de Superfície
19.
Nat Mater ; 7(11): 907-15, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18836435

RESUMO

The high natural abundance of silicon, together with its excellent reliability and good efficiency in solar cells, suggest its continued use in production of solar energy, on massive scales, for the foreseeable future. Although organics, nanocrystals, nanowires and other new materials hold significant promise, many opportunities continue to exist for research into unconventional means of exploiting silicon in advanced photovoltaic systems. Here, we describe modules that use large-scale arrays of silicon solar microcells created from bulk wafers and integrated in diverse spatial layouts on foreign substrates by transfer printing. The resulting devices can offer useful features, including high degrees of mechanical flexibility, user-definable transparency and ultrathin-form-factor microconcentrator designs. Detailed studies of the processes for creating and manipulating such microcells, together with theoretical and experimental investigations of the electrical, mechanical and optical characteristics of several types of module that incorporate them, illuminate the key aspects.

20.
Nature ; 454(7205): 748-53, 2008 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-18685704

RESUMO

The human eye is a remarkable imaging device, with many attractive design features. Prominent among these is a hemispherical detector geometry, similar to that found in many other biological systems, that enables a wide field of view and low aberrations with simple, few-component imaging optics. This type of configuration is extremely difficult to achieve using established optoelectronics technologies, owing to the intrinsically planar nature of the patterning, deposition, etching, materials growth and doping methods that exist for fabricating such systems. Here we report strategies that avoid these limitations, and implement them to yield high-performance, hemispherical electronic eye cameras based on single-crystalline silicon. The approach uses wafer-scale optoelectronics formed in unusual, two-dimensionally compressible configurations and elastomeric transfer elements capable of transforming the planar layouts in which the systems are initially fabricated into hemispherical geometries for their final implementation. In a general sense, these methods, taken together with our theoretical analyses of their associated mechanics, provide practical routes for integrating well-developed planar device technologies onto the surfaces of complex curvilinear objects, suitable for diverse applications that cannot be addressed by conventional means.


Assuntos
Materiais Biomiméticos , Biomimética/instrumentação , Eletrônica/instrumentação , Olho , Silício/química , Humanos , Lasers , Iluminação , Semicondutores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...