Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1009228

RESUMO

OBJECTIVE@#To investigate the clinical effect of total hip replacement (THA) in the treatment of traumatic arthritis secondary to acetabular fracture.@*METHODS@#From October 2019 to June 2022, 15 patients with secondary traumatic arthritis of acetabulum fracture were treated with THA. There were 8 males and 7 females, aged from 40 to 76 years old with an average of (59.20±9.46) years old. Prosthesis loosening, dislocation of hip joint, range of motion of hip joint, nerve injury and other conditions were recorded before and after surgery. Harris score, visual analogue scale (VAS) and imaging were used to evaluate hip joint function and surgical effect.@*RESULTS@#Follow-up time ranged 6 to 39 months with an average of (18.33±9.27) months. All the 15 patients successfully completed the operation, no nerve and blood vessel injury during the operation, postoperative wound healing was stageⅠ, no infection, one case of acetabular side prosthesis loosening at half a year after operation, and recovered well after revision surgery, one case of hip dislocation was cured after open reduction treatment, no adverse consequences. Harris score at the last postoperative follow-up was (88.60±4.01) points, compared with the preoperative (47.20±11.77) points, the difference was statistically significant (P<0.05), and VAS at the lateat postoperative follow-up was 1 (1) points, compared with the preoperative 8 (2) points, the difference was statistically significant (P<0.05). At the last follow-up, the pain symptoms were relieved or disappeared, and the joint function was satisfactory. The imaging data of the latest follow-up showed joint was well pseudoradiated, no abnormal ossification occurred, and the prosthesis was not loose.@*CONCLUSION@#THA is effective in the treatment of traumatic arthritis secondary to acetabular fracture and can effectively improve the quality of life of patients. Preoperative comprehensive evaluation and bone defect evaluation of patients, and intraoperative management of acetabulum, femur, internal fixation and bone defect are key factors for the success of surgery.


Assuntos
Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/métodos , Falha de Prótese , Estudos Retrospectivos , Qualidade de Vida , Acetábulo/lesões , Prótese de Quadril , Fraturas do Quadril/cirurgia , Fraturas da Coluna Vertebral/cirurgia , Artrite/cirurgia , Resultado do Tratamento , Seguimentos
2.
Orthop Surg ; 15(7): 1806-1813, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37310092

RESUMO

OBJECTIVE: Increasing evidence has shown that calf muscular vein thrombosis (CMVT) can develop into proximal deep vein thrombosis, even causing pulmonary embolism. However, opinions about the prevalence and risk factors are still controversial. This study aimed to investigate the prevalence and risk factors for CMVT in elderly patients with hip fractures to facilitate their preoperative management. METHODS: We included 419 elderly patients with hip fracture who were treated in the orthopaedic department of our hospital from June 2017 to December 2020. The patients were divided into CMVT and non-CMVT groups based on color Doppler ultrasound screening of the venous system in the lower extremities. Clinical data, such as age, sex, body mass index, time from injury to admission, and laboratory data were collected. Univariate and multivariate logistic regression analyses were performed to determine independent risk factors for CMVT. A receiver operating characteristic curve was used to analyze the predictive effectiveness of the model. Finally, the clinical utility of the model was analyzed using decision curve analysis and clinical impact curves. RESULTS: The prevalence of preoperative CMVT was 30.5% (128/419). Independent predictors of preoperative CMVT identified by univariate and multivariate logistic regression analyses were sex, time from injury to admission, American Society of Anesthesiologists (ASA) classification, C-reactive protein (CRP) level, and D-dimer level (p < 0.05). The area under curve (AUC) was 0.750 (95% CI: 0.699-0.800, p < 0.001) and the sensitivity and specificity were 0.698 and 0.711, respectively, which meant the prediction model has a good efficacy in the prediction of CMVT risk. In addition, the fitting degree of the prediction model was also good (Hosmer-Lemeshow χ2 = 8.447, p > 0.05). The clinical utility of the model was verified using decision curve analysis and clinical impact curves. CONCLUSION: Sex, time from injury to admission, ASA classification, CRP level, and D-dimer levels are independent preoperative predictors of CMVT in elderly patients with hip fractures. Measures should be taken for patients with these risk factors to prevent the occurrence and deterioration of CMVT.


Assuntos
Fraturas do Quadril , Trombose , Humanos , Idoso , Prevalência , Estudos Retrospectivos , Fraturas do Quadril/cirurgia , Fraturas do Quadril/epidemiologia , Fatores de Risco
3.
Front Surg ; 10: 964160, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36936650

RESUMO

Purpose: To determine the side-to-side difference in intraindividual rotation alignment of patients with bilateral varus-type knee osteoarthritis (OA) and compare it with control subjects. Methods: This retrospective study enrolled 60 patients with bilateral varus-type knee OA and 50 control subjects. All cases underwent bilateral lower limb CT angiography. Bilateral femoral and tibial rotation alignment were measured, and the overall lower limb rotation was calculated by two different methods. Method 1 was calculated by subtracting angle of the femoral torsion from the tibial torsion and method 2 was determined by relative rotation of the femoral neck angle to bimalleolar angle. The intraindividual variance and differences between the two groups were analyzed. Results: Both OA and control samples showed significant differences between right and left for all measurements. Femoral torsion for control group was 10.4 ± 5.5°, tibial torsion was -22.1 ± 6.1°, and overall leg rotation by method 1 was -15.6 ± 7.2° and method 2 was -11.7 ± 8.2°. Femoral torsion, tibial torsion, method 1, and method 2 in the patients with OA were 8.2 ± 6.3°, -18.6 ± 4.1°, -14.9 ± 7.9°, and -10.4 ± 7.6°, respectively. Patients with OA showed a more pronounced retroversion in the femur (p = 0.008) and more internal rotation in the tibia (p < 0.001). No statistical significance of both methods was found between the two groups. Patients with OA had a greater median side-to-side absolute difference in all measurements, though the differences of both two methods of overall lower limb rotation were not statistically significant. Conclusions: The discrepancy of side-to-side differences of bilateral lower limb rotation ought to be noticed with caution in diagnosing and treating rotational deformities of the lower limb, especially for patients with bilateral knee OA.

4.
Acta Pharmaceutica Sinica ; (12): 652-656, 2008.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-277780

RESUMO

To prepare verapamil hydrochloride (VH) core-in-cup tablets with tri-layered tablet and four-layered tablet as core tablets, separately, which can provide biphasic release with double-pulsatile and multi-phasic release, core tablets were prepared by direct compression method, and core-in-cup tablets by dry-compression coated technology. The parameter, time-lag (T(lag)), was used to evaluate the influence of factors, such as the weight of the top cover layer, the amount of hydroxypropylmethylcellulose (HPMC), and the compression load on VH release. With the increase of the weight and HPMC amount of the top cover layer, the first lag time T(lag1) was prolonged. The second lag time T(lag2) of core-in-cup tablet with four-layered tablet as core tablet increased with the increasing amount of HPMC K100M. With the increase of compression load among the range (6 - 10 kg x cm(-2)), the two lag times were prolonged. Core-in-cup tablets with double-pulsatile and multi-phasic release released VH after the first lag time (4 -5 h), then kept sustained release for 12 h or 13 h, finally released rapidly. The drug in the core-in-cup tablet only released from the top cover layer. T(lag) is determined by the erosion rate of the inhibitor layers (the top cover layer and the sustained-release layer of the multi-layer core tablet).


Assuntos
Preparações de Ação Retardada , Portadores de Fármacos , Composição de Medicamentos , Métodos , Sistemas de Liberação de Medicamentos , Excipientes , Química , Derivados da Hipromelose , Metilcelulose , Química , Comprimidos , Verapamil
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...