Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 83(9): 093112, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23020367

RESUMO

The paper presents the development and demonstrates the capabilities of a new laboratory-based environmental X-ray photoelectron spectroscopy system incorporating an electrostatic lens and able to acquire spectra up to 0.4 Torr. The incorporation of a two-dimensional detector provides imaging capabilities and allows the acquisition of angle-resolved data in parallel mode over an angular range of 14° without tilting the sample. The sensitivity and energy resolution of the spectrometer have been investigated by analyzing a standard Ag foil both under high vacuum (10(-8) Torr) conditions and at elevated pressures of N(2) (0.4 Torr). The possibility of acquiring angle-resolved data at different pressures has been demonstrated by analyzing a silicon/silicon dioxide (Si/SiO(2)) sample. The collected angle-resolved spectra could be effectively used for the determination of the thickness of the native silicon oxide layer.

2.
Rev Sci Instrum ; 81(6): 063112, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20590230

RESUMO

We have developed a rotatable hemispherical spectrometer with good energy and angular resolution, which can be positioned with the lens axis arbitrarily within a solid angle of 1 pi. The collection angle of the emitted electrons with respect to the polarization axis of the light is set by means of a three-axes goniometer, operating under vacuum. An important requirement for this setup was the possibility to perform coincidences between the electron analyzed by the spectrometer and one or several other particles, such as ions, electrons, or photons. The lens system and the hemispheres have been designed to accommodate such experimental demands, regarding parameters such as the resolving power, the acceptance angle, or the width of the kinetic energy window which can be recorded for a given pass energy. We have chosen to detect the impact position of the electron at the focal plane of the hemispherical analyzer with a delay line detector and a time-to-digital converter as acquisition card rather than using a conventional charge-coupled device camera.

3.
Rev Sci Instrum ; 81(3): 035104, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20370210

RESUMO

A new type of hemispherical electron energy analyzer that permits angle and spin resolved photoelectron spectroscopy has been developed. The analyzer permits standard angle resolved spectra to be recorded with a two-dimensional detector in parallel with spin detection using a mini-Mott polarimeter. General design considerations as well as technical solutions are discussed and test results from the Au(111) surface state are presented.

14.
Phys Rev A Gen Phys ; 40(8): 4369-4377, 1989 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-9902678
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...