Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 121: 91-95, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28040603

RESUMO

Assessment of chromium content in human nail or nail clippings could serve as an effective biomarker of chromium status. The feasibility of a new portable x-ray fluorescence (XRF) approach to chromium measurement was investigated through analysis of nail and nail clipping phantoms. Five measurements of 180s (real time) duration were first performed on six whole nail phantoms having chromium concentrations of 0, 2, 5, 10, 15, and 20µg/g. Using nail clippers, these phantoms were then converted to nail clippings, and assembled into different mass groups of 20, 40, 60, 80, and 100mg for additional measurements. The amplitude of the chromium Kα characteristic x-ray energy peak was examined as a function of phantom concentration for all measurement conditions to create a series of calibration lines. The minimum detection limit (MDL) for chromium was also calculated for each case. The chromium MDL determined from the whole nail intact phantoms was 0.88±0.03µg/g. For the clipping phantoms, the MDL ranged from 1.2 to 3.3µg/g, depending on the mass group analyzed. For the 40mg clipping group, the MDL was 1.2±0.1µg/g, and higher mass collections did not improve upon this result. This MDL is comparable to chromium concentration levels seen in various studies involving human nail clippings. Further improvements to the portable XRF technique would be required to detect chromium levels expected from the lower end of a typical population.


Assuntos
Cromo/análise , Unhas/química , Espectrometria por Raios X/métodos , Biomarcadores/análise , Calibragem , Estudos de Viabilidade , Humanos , Limite de Detecção , Imagens de Fantasmas , Espectrometria por Raios X/instrumentação , Espectrometria por Raios X/normas , Oligoelementos/análise
2.
Appl Radiat Isot ; 120: 1-6, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27889549

RESUMO

The feasibility of measuring arsenic and selenium contents in a single nail clipping was investigated using a small-focus portable X-ray fluorescence (XRF) instrument with monochromatic excitation beams. Nail clipping phantoms supplemented with arsenic and selenium to produce materials with 0, 5, 10, 15, and 20µg/g were used for calibration purposes. In total, 10 different clippings were analyzed at two different measurement positions. Energy spectra were fit with detection peaks for arsenic Kα, selenium Kα, arsenic Kß, selenium Kß, and bromine Kα characteristic X-rays. Data analysis was performed under two distinct conditions of fitting constraint. Calibration lines were established from the amplitude of each of the arsenic and selenium peaks as a function of the elemental contents in the clippings. The slopes of the four calibration lines were consistent between the two conditions of analysis. The calculated minimum detection limit (MDL) of the method, when considering the Kα peak only, ranged from 0.210±0.002µg/g selenium under one condition of analysis to 0.777±0.009µg/g selenium under another. Compared with previous portable XRF nail clipping studies, MDLs were substantially improved for both arsenic and selenium. The new measurement technique had the additional benefits of being short in duration (~3min) and requiring only a single nail clipping. The mass of the individual clipping used did not appear to play a major role in signal strength, but positioning of the clipping is important.


Assuntos
Arsênio/análise , Unhas/química , Selênio/análise , Espectrometria por Raios X/instrumentação , Arsênio/toxicidade , Calibragem , Exposição Ambiental , Estudos de Viabilidade , Humanos , Limite de Detecção , Imagens de Fantasmas , Selênio/toxicidade , Espectrometria por Raios X/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...