Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 59(5): 776-784, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32273159

RESUMO

OBJECTIVE: The chimney technique (ChEVAR) allows for proximal landing zone extension for endovascular repair of complex aortic aneurysms. The aim of the present study was to assess ChEVAR national outcomes in French university hospital centres. METHODS: All centres were contacted and entered data into a computerised online database on a voluntary basis. Clinical and radiological data were collected on all consecutive ChEVAR patients operated on in 14 centres between 2008 and 2016. Patients were deemed unfit for open repair. Factors associated with early (30 day or in hospital) mortality and type 1 endoleak (Type I EL) were calculated using multivariable analysis. RESULTS: In total, 201 patients with 343 target vessels were treated. There were 94 juxtarenal (46.8%), 67 pararenal (33.3%), 10 Crawford type IV thoraco-abdominal (5%) aneurysms, and 30 (15.1%) proximal failures of prior repairs. The pre-operative diameter was 66.8 ± 16.7 mm and 28 (13.9%) ChEVAR were performed as an emergency, including six (2.9%) ruptures. There were 23 (11.7%) unplanned intra-operative procedures, mainly related to access issues. The rate of early deaths was 11.4% (n = 23). The elective mortality rate was 9.8% (n = 17). Nine patients (4.5%) presented with a stroke. The rate of early proximal Type I EL was 11.9%. Survival was 84.6%, 79.4%, 73.9%, 71.1% at 6, 12, 18, and 24 months, respectively. The primary patency of chimney stents was 97.4%, 96.7%, 95.2%, and 93.3% at 6, 12, 18, and 24 months, respectively. Performing unplanned intra-operative procedures (OR 3.7, 95% CI 1.3-10.9) was identified as the only independent predictor of post-operative death. A ChEVAR for juxtarenal aneurysm was independently associated with fewer post-operative Type I ELs (OR 0.17, 95% CI 0.05-0.58). CONCLUSION: In this large national ChEVAR series, early results were concerning. The reasons may lie in heterogeneous practices between centres and ChEVAR use outside of current recommendations regarding oversizing rates, endograft types, and sealing zones. Future research should focus on improvements in pre-operative planning and intra-operative technical aspects.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , França , Hospitais Universitários , Humanos , Masculino , Estudos Retrospectivos , Resultado do Tratamento
2.
Ann Vasc Surg ; 61: 471.e3-471.e7, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31394215

RESUMO

The present case describes acute and early infection of a superficial femoral artery drug-eluting stent (DES) in a 65-year-old patient 2 days after its implantation in outpatient clinic, with intense clinical presentation. The initial indication was Rutherford 3 peripheral artery disease. Radical treatment by means of stent explantation and femoro-femoral bypass using autogenous vein was performed. Both stent and blood cultures were positive for methicillin-sensitive Staphylococcus aureus. Informative imaging and intraoperative view are provided. Local evolution was satisfactory but endocarditis occurred secondarily. The pathophysiology of this first reported DES infection and the management of the infected vessel are discussed, in light of data derived from coronary literature and open vascular surgery.


Assuntos
Stents Farmacológicos/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Artéria Femoral/microbiologia , Doença Arterial Periférica/terapia , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/microbiologia , Idoso , Antibacterianos/uso terapêutico , Remoção de Dispositivo , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Artéria Femoral/cirurgia , Humanos , Masculino , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Veia Safena/transplante , Infecções Estafilocócicas/diagnóstico , Infecções Estafilocócicas/cirurgia , Fatores de Tempo , Resultado do Tratamento
3.
Ann Vasc Surg ; 33: 229.e7-229.e10, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26902937

RESUMO

We report a patient who developed a type B aortic dissection and ruptured his aneurysmal sac 1 year after endovascular abdominal aortic aneurysm repair (EVAR), despite standard follow-up. This 79-year-old man was presented to emergency room with acute abdominal pain and an acute lower limb ischemia. Computed tomography scan showed an acute type B aortic dissection feeding the aneurysmal sac of the EVAR. The aneurysm rupture occurred during imaging. Type B aortic dissection is a rare cause of aneurysmal rupture after EVAR. The first postoperative computed tomography scan should maybe include the arch and the descending thoracic aorta to rule out an iatrogenic dissection after EVAR.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/etiologia , Ruptura Aórtica/etiologia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Doença Iatrogênica , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/cirurgia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Emergências , Evolução Fatal , Humanos , Masculino , Reoperação , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...