Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Med Chem ; 65(19): 12883-12894, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-36194724

RESUMO

Cancer cells deploy several glucose transport protein (GLUT) channels on the cell membranes to increase glucose uptake. Cancer cells die within 24 h in the absence of glucose. Thus, preventing the deployment of GLUT channels can deprive them of glucose, resulting in apoptosis within 24 h. Herein, we developed the ID-Checker with a glucose tag that ensures its highly specific macroscale delivery of anticancer agents to the cancer cells through the GLUT channels. ID-Checker presented here showed IC50 values of 0.17-0.27 and 3.34 µM in cancer and normal cell lines, respectively. ID-Checker showed a selectivity index of 12.5-20.2, which is about 10-20 times higher than that of known anticancer agents such as colchicine. ID-Checker inhibits the microtubule formation, which results in the prevention of the deployment of GLUT channels in 6 h and kills the cancer cells within 24 h without any damage to normal cells.


Assuntos
Antineoplásicos , Neoplasias , Antineoplásicos/farmacologia , Colchicina , Glucose/metabolismo , Proteínas Facilitadoras de Transporte de Glucose/metabolismo , Transportador de Glucose Tipo 1 , Neoplasias/tratamento farmacológico , Tecnologia
2.
Biosensors (Basel) ; 12(2)2022 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-35200387

RESUMO

Lung cancer is a leading cause of death worldwide, claiming nearly 1.80 million lives in 2020. Screening with low-dose computed tomography (LDCT) reduces lung cancer mortality by about 20% compared to standard chest X-rays among current or heavy smokers. However, several reports indicate that LDCT has a high false-positive rate. In this regard, methods based on biomarker detection offer excellent potential for developing noninvasive cancer diagnostic tests to complement LDCT for detecting stage 0∼IV lung cancers. Herein, we have developed a method for detecting and quantifying a p53-anti-p53 autoantibody complex and the total p53 antigen (wild and mutant). The LOD for detecting Tp53 and PIC were 7.41 pg/mL and 5.74 pg/mL, respectively. The detection ranges for both biomarkers were 0-7500 pg/mL. The known interfering agents in immunoassays such as biotin, bilirubin, intra-lipid, and hemoglobin did not detect Tp53 and PIC, even at levels that were several folds higher levels than their normal levels. Furthermore, the present study provides a unique report on this preliminary investigation using the PIC/Tp53 ratio to detect stage I-IV lung cancers. The presented method detects lung cancers with 81.6% sensitivity and 93.3% specificity. These results indicate that the presented method has high applicability for the identification of lung cancer patients from the healthy population.


Assuntos
Neoplasias Pulmonares , Proteína Supressora de Tumor p53 , Complexo Antígeno-Anticorpo , Biomarcadores , Detecção Precoce de Câncer/métodos , Humanos , Neoplasias Pulmonares/diagnóstico
3.
Drug Dev Res ; 83(3): 769-782, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35038352

RESUMO

Microtubule targeting agents (MTAs) are the potential drug candidates for anticancer drug discovery. Disrupting the microtubule formation or inhibiting the de-polymerization process by a synthetic molecule can lead to an excellent anticancer drug candidate. Here, we present the 2,5-substituted-1H-benzo[d]imidazole derivatives as potential colchicine, nocodazole binding site targeting agents. About 20 benzimidazole derivatives were synthesized with 82.0%-94.0% yield using mild reaction conditions. The synthesized compounds showed moderate to excellent anticancer activity established in three cell lines, including Hela cells, A549 cells, MRC-5 cells. The compounds B15, B16, B19, and B20 are the potential candidates with the IC50 values <15 µM in the three different cell lines. In MTT assay, compounds B15, B16, B19, and B20 showed excellent antiproliferation activity indicated by IC50 values in the range of 5.3 ± 0.21 to 18.1 ± 0.32 µM using HeLa and A549 cell lines. The predicted absorption, distribution, metabolism and excretion (ADME) properties and drug-likeness properties of B15, B16, B19, and B20 indicate that these compounds can be used as lead compounds for further study to develop excellent MTAs.


Assuntos
Antineoplásicos , Moduladores de Tubulina , Antibacterianos/farmacologia , Antifúngicos/farmacologia , Antineoplásicos/química , Linhagem Celular Tumoral , Proliferação de Células , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Células HeLa , Humanos , Imidazóis/química , Imidazóis/farmacologia , Microtúbulos/metabolismo , Estrutura Molecular , Relação Estrutura-Atividade , Tubulina (Proteína)/metabolismo , Tubulina (Proteína)/farmacologia , Moduladores de Tubulina/química , Moduladores de Tubulina/farmacologia
4.
Bioorg Chem ; 119: 105490, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34836645

RESUMO

The reported methods mainly use biomolecules such as antibodies, enzymes, and aptamers for biomarker detection. However, applying an abiotic fluorescent probe to detect cancer biomarkers such as carcinoembryonic antigen (CEA) has not been reported. In this regard, we conceived an abiotic fluorescent probe BIQ-1 for the rapid yet straightforward detection of CEA. The bioinformatics tools and molecular docking techniques were used to develop the probe BIQ-1 for the selective detection and quantification of CEA in a buffer matrix resembling serum. The probe BIQ-1 exhibited a limit of detection of 0.2 ng/mL for CEA in a simple cuvette-based experiment. The BIQ-1 did no show interference from the possible interfering components such as hemoglobin, intralipid, and human serum albumin (HSA) in concentrations several-fold higher (µg/mL) than CEA.


Assuntos
Biomarcadores Tumorais , Antígeno Carcinoembrionário , Corantes Fluorescentes , Humanos , Biomarcadores Tumorais/sangue , Antígeno Carcinoembrionário/sangue , Biologia Computacional , Relação Dose-Resposta a Droga , Corantes Fluorescentes/síntese química , Corantes Fluorescentes/química , Simulação de Acoplamento Molecular , Estrutura Molecular , Relação Estrutura-Atividade
5.
Biosensors (Basel) ; 11(11)2021 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-34821635

RESUMO

The measurement of cysteine in human urine and live cells is crucial for evaluating biological metabolism, monitoring and maintaining the immune system, preventing tissue/DNA damage caused by free radicals, preventing autoimmune diseases, and diagnosing disorders such as cystinuria and cancer. A method that uses a fluorescence turn-on probe and a portable fluorescence spectrometer device are crucial for highly sensitive, simple, rapid, and inexpensive cysteine detection. Herein, we present the synthesis and application of a benzimidazole-based fluorescent probe (ABIA) along with the design and development of a portable fluorescence spectrometer device (CysDDev) for detecting cysteine in simulated human urine. ABIA showed excellent selectivity and sensitivity in detecting cysteine over homocysteine, glutathione, and other amino acids with the response time of 1 min and demonstrated a detection limit of 16.3 nM using the developed CysDDev. Further, ABIA also demonstrated its utility in detecting intracellular cysteine, making it an excellent probe for bio-imaging assay.


Assuntos
Cisteína , Corantes Fluorescentes , Benzimidazóis , Cisteína/urina , Glutationa , Humanos , Espectrometria de Fluorescência
6.
Biosensors (Basel) ; 11(8)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34436067

RESUMO

Highly sensitive (high SBR) and highly specific (high SNP discrimination ratio) DNA hybridization is essential for a biosensor with clinical application. Herein, we propose a method that allows detecting multiple pathogens on a single platform with the SNP discrimination ratios over 160:1 in the dynamic range of 101 to 104 copies per test. The newly developed SWAT method allows achieving highly sensitive and highly specific DNA hybridizations. The detection and discrimination of the MTB and NTM strain in the clinical samples with the SBR and SNP discrimination ratios higher than 160:1 indicate the high clinical applicability of the SWAT.


Assuntos
Técnicas Biossensoriais , Hibridização de Ácido Nucleico , DNA , Humanos , Projetos de Pesquisa
7.
Cancers (Basel) ; 12(11)2020 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-33143045

RESUMO

A complimentary biomarker test that can be used in combination with LDCT for lung cancer screening is highly desirable to improve the diagnostic capacity of LDCT and reduce the false-positive rates. Most importantly, the stage I lung cancer detection rate can be dramatically increased by the simultaneous use of a biomarker test with LDCT. The present study was conducted to evaluate 9G testTM Cancer/Lung's sensitivity and specificity in detecting Stage 0~IV lung cancer. The obtained results indicate that the 9G testTM Cancer/Lung can detect lung cancer with overall sensitivity and specificity of 75.0% (69.1~80.3) and 97.3% (95.0~98.8), respectively. The detection of stage I, stage II, stage III, and stage IV cancers with sensitivities of 77.5%, 78.1%, 67.4%, and 33.3%, respectively, at the specificity of 97.3% have never been reported before. The receiver operating characteristic curve analysis allowed us to determine the population-weighted AUC of 0.93 (95% CI, 0.91-0.95). These results indicate that the 9G testTM Cancer/Lung can be used in conjunction with LDCT to screen lung cancer. Furthermore, obtained results indicate that the use of 9G testTM Cancer/Lung with LDCT for lung cancer screening can increase stage I cancer detection, which is crucial to improve the currently low 5-year survival rates.

8.
ACS Omega ; 5(19): 10794-10799, 2020 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-32455199

RESUMO

The World Health Organization and the World Health Assembly recommended eradicating hepatitis as a public threat by 2030. The accurate genotyping of hepatitis C virus (HCV) is crucial to achieving this goal because it is vital for the selection of anti-HCV therapy required for complete cure of HCV infection. We report the development of a method for accurate genotyping of HCV 1a, 1b, 2, 3, 4, and 6 genotypes. The merits of the developed method for HCV genotyping include (i) requirement of a single polymerase chain reaction (PCR) primer set, (ii) room-temperature detection in 30 min after the PCR, (iii) no need of highly trained professionals, (iv) highly accurate HCV genotyping results afforded by highly specific DNA-DNA hybridization, and (v) probe sequences that can be used on other platforms.

9.
Sensors (Basel) ; 19(19)2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-31575036

RESUMO

Hepatitis C virus (HCV) accounts for 15%-20% of cases of acute infection, and chronic HCV infection is developed in about 50%-80% of HCV patients. Unfortunately, due to the lack of proper medical care, difficulty in screening for HCV infection, and lack of awareness resulted in chronic HCV infection in 71 million people on a global scale, and about 399,000 deaths in 2016. It is crucial to recognize that the effective use of antiviral medicines can cure more than 95% of HCV infected people. The Global Health Sector Strategy (GHSS) aim is to reduce the new HCV infections and the HCV associated mortality by 90% and 65%, respectively. Therefore, the methods that are simple, yet powerful enough to detect HCV infections with high sensitivity, specificity, and a shorter window period are crucial to restrain the global burden of HCV healthcare. This article focuses on the technologies used for the detection of HCV in clinical specimens.


Assuntos
Hepacivirus/imunologia , Hepatite C/diagnóstico , Immunoblotting/métodos , Técnicas Imunoenzimáticas/métodos , Anticorpos Antivirais/análise , Antígenos Virais/análise , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Hepacivirus/genética , Hepatite C/imunologia , Humanos , Luminescência , Proteínas Virais/metabolismo
10.
Chem Commun (Camb) ; 55(73): 10984, 2019 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-31475260

RESUMO

Correction for 'Quantification of CYFRA 21-1 and a CYFRA 21-1-anti-CYFRA 21-1 autoantibody immune complex for detection of early stage lung cancer' by Keum-Soo Song et al., Chem. Commun., 2019, 55, 10060-10063.

11.
Chem Commun (Camb) ; 55(68): 10060-10063, 2019 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-31328750
12.
Sensors (Basel) ; 18(10)2018 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-30322029

RESUMO

According to the World Health Organization (WHO), 71 million people were living with Hepatitis C virus (HCV) infection worldwide in 2015. Each year, about 399,000 HCV-infected people succumb to cirrhosis, hepatocellular carcinoma, and liver failure. Therefore, screening of HCV infection with simple, rapid, but highly sensitive and specific methods can help to curb the global burden on HCV healthcare. Apart from the determination of viral load/viral clearance, the identification of specific HCV genotype is also critical for successful treatment of hepatitis C. This critical review focuses on the technologies used for the detection, discrimination, and genotyping of HCV in clinical samples. This article also focuses on advantages and disadvantages of the reported methods used for HCV detection, quantification, and genotyping.


Assuntos
Técnicas Biossensoriais/métodos , Hepacivirus/genética , Hepatite C/diagnóstico , Nanotecnologia/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Técnicas Biossensoriais/instrumentação , Técnicas de Genotipagem , Hepatite C/genética , Humanos , Nanopartículas , Nanotecnologia/instrumentação , Nanotubos de Carbono , Pontos Quânticos , Reação em Cadeia da Polimerase em Tempo Real , Transcrição Reversa , Carga Viral/genética
13.
Sensors (Basel) ; 17(9)2017 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-28906476

RESUMO

Cardiovascular diseases such as acute myocardial infarction and heart failure accounted for the death of 17.5 million people (31% of all global deaths) in 2015. Monitoring the level of circulating N-terminal proBNP (NT-proBNP) is crucial for the detection of people at risk of heart failure. In this article, we describe a novel ultra-sensitive NT-proBNP test (us-NT-proBNP) that allows the quantification of circulating NT-proBNP in 30 min at 25 °C in the linear detection range of 7.0-600 pg/mL. It is a first report on the application of a fluorescence bead labeled detection antibody, DNA-guided detection method, and glass fiber membrane platform for the quantification of NT-proBNP in clinical samples. Limit of blank, limit of detection, and limit of quantification were 2.0 pg/mL, 3.7 pg/mL, and 7 pg/mL, respectively. The coefficient of variation was found to be less than 10% in the entire detection range of 7-600 pg/mL. The test demonstrated specificity for NT-proBNP without interferences from bilirubin, intra-lipid, biotin, and hemoglobin. The serial dilution test for plasma samples containing various NT-proBNP levels showed the linear decrement in concentration with the regression coefficient of 0.980-0.998. These results indicate that us-NT-proBNP test does not suffer from the interference of the plasma components for the measurement of NT-proBNP in clinical samples.


Assuntos
Insuficiência Cardíaca , Biomarcadores , Humanos , Infarto do Miocárdio , Peptídeo Natriurético Encefálico , Fragmentos de Peptídeos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...