1.
Perfusion ; 38(5): 1088-1091, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-35619539

RESUMO

INTRODUCTION: No antidote or established extracorporeal elimination strategy is available for argatroban. Hemadsorption facilitates elimination of smaller drugs. CASE REPORT: A 34-year-old patient underwent urgent heart transplantation. Because of a history of heparin-induced thrombocytopenia, preoperative anticoagulation was performed with argatroban. Despite ceasing of the continuous infusion of argatroban 2 h before surgery, concentration only declined from 0.60 µg/ml to 0.58 µg/ml before surgery, and the activated clotting time (ACT) value shortly was 223 s. Microvascular bleeding had been observed when starting surgery. A CytoSorb® absorption column was integrated into the system of the heparin-anticoagulated cardiopulmonary bypass (CPB) circuit and a flow of 400 mL/min provided during the 2 h of extracorporeal circulation. The argatroban concentration after weaning from CPB was 0.04 µg/ml and satisfying hemostasis had been achieved after protamine administration. CONCLUSION: Data indicate that the CytoSorb® absorption column might be an effective tool for quick extracorporeal removal of therapeutic concentrations of argatroban.