Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Appl Physiol (1985) ; 91(4): 1600-10, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11568141

RESUMO

There is presently significant interest in cellular responses to physical forces, and numerous devices have been developed to apply stretch to cultured cells. Many of the early devices were limited by the heterogeneity of deformation of cells in different locations and by the high degree of anisotropy at a particular location. We have therefore developed a system to impose cyclic, large-strain, homogeneous stretch on a multiwell surface-treated silicone elastomer substrate plated with pulmonary epithelial cells. The pneumatically driven mechanism consists of four plates each with a clamp to fix one edge of the cruciform elastomer substrate. Four linear bearings set at predetermined angles between the plates ensure a constant ratio of principal strains throughout the stretch cycle. We present the design of the device and membrane shape, the surface modifications of the membrane to promote cell adhesion, predicted and experimental measurements of the strain field, and new data using cultured airway epithelial cells. We present for the first time the relationship between the magnitude of cyclic mechanical strain and the extent of wound closure and cell spreading.


Assuntos
Células Cultivadas/fisiologia , Técnicas Citológicas/instrumentação , Algoritmos , Fenômenos Biomecânicos , Células Cultivadas/metabolismo , Dinoprostona/biossíntese , Células Epiteliais/metabolismo , Células Epiteliais/fisiologia , Células Epiteliais/ultraestrutura , Análise de Elementos Finitos , Humanos , Membranas Artificiais , Pressão , Prostaglandinas/biossíntese , Espectrometria por Raios X , Propriedades de Superfície , Ferimentos e Lesões/patologia
2.
Radiology ; 218(3): 683-8, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11230640

RESUMO

PURPOSE: To evaluate the imaging characteristics of an amorphous silicon flat-panel detector (FPD) for digital chest radiography. MATERIALS AND METHODS: The 41 x 41-cm digital FPD is constructed on a single monolithic glass substrate with a structured cesium iodide scintillator layer and an amorphous silicon thin-film transistor array for image readout. Basic imaging characteristics of the FPD and associated image processing system were assessed on acquired images, including linearity, repeatability, uniformity of response, modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), contrast sensitivity, and scatter content. Results with the FPD system were compared to those with a storage phosphor computed radiography (CR) system. RESULTS: Images obtained with the FPD demonstrated excellent uniformity, repeatability, and linearity, as well as MTF and DQE that were superior to those with the storage phosphor CR system. The contrast and scatter content of images acquired with the FPD were equivalent to those acquired with the storage phosphor system. CONCLUSION: The FPD provides radiographic images with excellent inherent physical image quality.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Radiografia Torácica/instrumentação , Estudos de Avaliação como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA