Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 126: 168-170, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28236554

RESUMO

The Ultra-Low Background Liquid Scintillation Counter developed by Pacific Northwest National Laboratory will expand the application of liquid scintillation counting by enabling lower detection limits and smaller sample volumes. By reducing the overall count rate of the background environment approximately 2 orders of magnitude below that of commercially available systems, backgrounds on the order of tens of counts per day over an energy range of ~3-3600keV can be realized. Initial test results of the ULB LSC show promising results for ultra-low background detection with liquid scintillation counting.

2.
Appl Radiat Isot ; 105: 209-218, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26334781

RESUMO

Pacific Northwest National Laboratory has recently opened a shallow underground laboratory intended for measurement of low-concentration levels of radioactive isotopes in samples collected from the environment. The development of a low-background liquid scintillation counter is currently underway to further augment the measurement capabilities within this underground laboratory. Liquid scintillation counting is especially useful for measuring charged particle (e.g., ß and α) emitting isotopes with no (or very weak) gamma-ray yields. The combination of high-efficiency detection of charged particle emission in a liquid scintillation cocktail coupled with the low-background environment of an appropriately designed shield located in a clean underground laboratory provides the opportunity for increased-sensitivity measurements of a range of isotopes. To take advantage of the 35m-water-equivalent overburden of the underground laboratory, a series of simulations have evaluated the scintillation counter's shield design requirements to assess the possible background rate achievable. This report presents the design and background evaluation for a shallow underground, low background liquid scintillation counter design for sample measurements.

3.
Appl Radiat Isot ; 81: 151-5, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23623763

RESUMO

A new ultra-low-background proportional counter was recently developed with an internal volume of 100 cm(3) and has been characterized at pressures from 1-10 atm with P-10 (90% Ar, 10% methane) gas. This design, along with a counting system providing event digitization and passive and active shielding, has been developed to complement a new shallow underground laboratory (30 m water-equivalent). Backgrounds and low-level reference materials have been measured, and system sensitivity for (37)Ar has been calculated.


Assuntos
Argônio/análise , Gases/análise , Laboratórios , Radioisótopos/análise , Contagem de Cintilação/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Estados Unidos
4.
Rev Sci Instrum ; 83(11): 113503, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23206058

RESUMO

Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.

5.
Phys Rev Lett ; 87(17): 172301, 2001 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-11690266

RESUMO

Measurements of the (2)H((-->)e,e(')p)n reaction were performed with the out-of-plane magnetic spectrometers (OOPS) at the MIT-Bates Linear Accelerator. The longitudinal-transverse, f(LT) and f(')(LT), and the transverse-transverse, f(TT), interference responses at a missing momentum of 210 MeV/c were simultaneously extracted in the dip region at Q2 = 0.15 (GeV/c)(2). In comparison to models of deuteron electrodisintegration, the data clearly reveal strong effects of relativity and final-state interactions and the importance of two-body meson-exchange currents and isobar configurations. We demonstrate that such effects can be disentangled by extracting these responses using the novel out-of-plane technique.

6.
Phys Rev Lett ; 86(14): 2959-62, 2001 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-11290082

RESUMO

The recoil proton polarization has been measured in the p(e-->,e'p-->)pi(0) reaction in parallel kinematics around W = 1232 MeV, Q2 = 0.121 (GeV/c)2, and epsilon = 0.718 using the polarized cw electron beam of the Mainz Microtron. All three proton polarization components, Px/P(e) = (-11.4+/-1.3+/-1.4)%, P(y) = (-43.1+/-1.3+/-2.2)%, and P(z)/P(e) = (56.2+/-1.5+/-2.6)%, could be measured simultaneously. The Coulomb quadrupole to magnetic dipole ratio, CMR = (-6.4+/-0.7(stat)+/-0.8(syst))%, was determined from Px in the framework of the Mainz Unitary Isobar Model. The consistency among the reduced polarizations and the extraction of the ratio of longitudinal-to-transverse response is discussed.

7.
Phys Rev Lett ; 86(14): 2963-6, 2001 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-11290083

RESUMO

High-precision 1H(e,e'p)pi(0) measurements at Q2 = 0.126 (GeV/c)2 are reported, which allow the determination of quadrupole amplitudes in the gamma*N-->Delta transition; they simultaneously test the reliability of electroproduction models. The derived quadrupole-to-dipole ( I = 3/2) amplitude ratios, R(SM) = (-6.5+/-0.2(stat+sys)+/-2.5(mod))% and R(EM) = (-2.1+/-0.2(stat+sys)+/-2.0(mod))%, are dominated by model error. Previous R(SM) and R(EM) results should be reconsidered after the model uncertainties associated with the method of their extraction are taken into account.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...