Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 85(2): 023508, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593362

RESUMO

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the ignition stage of inertial confinement fusion (ICF) implosions at NIF. Since the neutron source is small (∼100 µm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-µm resolution are 20-cm long, single-sided tapers in gold. These apertures, which have triangular cross sections, produce distortions in the image, and the extended nature of the pinhole results in a non-stationary or spatially varying point spread function across the pinhole field of view. In this work, we have used iterative Maximum Likelihood techniques to remove the non-stationary distortions introduced by the aperture to reconstruct the underlying neutron source distributions. We present the detailed algorithms used for these reconstructions, the stopping criteria used and reconstructed sources from data collected at NIF with a discussion of the neutron imaging performance in light of other diagnostics.

3.
Phys Rev Lett ; 106(8): 085003, 2011 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-21405579

RESUMO

The first soft x-ray radiation flux measurements from hohlraums using both a 96 and a 192 beam configuration at the National Ignition Facility have shown high x-ray conversion efficiencies of ∼85%-90%. These experiments employed gold vacuum hohlraums, 6.4 mm long and 3.55 mm in diameter, heated with laser energies between 150-635 kJ. The hohlraums reached radiation temperatures of up to 340 eV. These hohlraums for the first time reached coronal plasma conditions sufficient for two-electron processes and coronal heat conduction to be important for determining the radiation drive.

4.
Rev Sci Instrum ; 81(10): 10E321, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034019

RESUMO

The first 96 and 192 beam vacuum Hohlraum target experiments have been fielded at the National Ignition Facility demonstrating radiation temperatures up to 340 eV and fluxes of 20 TW/sr as viewed by DANTE representing an ∼20 times flux increase over NOVA/Omega scale Hohlraums. The vacuum Hohlraums were irradiated with 2 ns square laser pulses with energies between 150 and 635 kJ. They produced nearly Planckian spectra with about 30±10% more flux than predicted by the preshot radiation hydrodynamic simulations. To validate these results, careful verification of all component calibrations, cable deconvolution, and software analysis routines has been conducted. In addition, a half Hohlraum experiment was conducted using a single 2 ns long axial quad with an irradiance of ∼2×10(15) W/cm(2) for comparison with NIF Early Light experiments completed in 2004. We have also completed a conversion efficiency test using a 128-beam nearly uniformly illuminated gold sphere with intensities kept low (at 1×10(14) W/cm(2) over 5 ns) to avoid sensitivity to modeling uncertainties for nonlocal heat conduction and nonlinear absorption mechanisms, to compare with similar intensity, 3 ns OMEGA sphere results. The 2004 and 2009 NIF half-Hohlraums agreed to 10% in flux, but more importantly, the 2006 OMEGA Au Sphere, the 2009 NIF Au sphere, and the calculated Au conversion efficiency agree to ±5% in flux, which is estimated to be the absolute calibration accuracy of the DANTEs. Hence we conclude that the 30±10% higher than expected radiation fluxes from the 96 and 192 beam vacuum Hohlraums are attributable to differences in physics of the larger Hohlraums.

5.
Rev Sci Instrum ; 81(10): 10E538, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21034065

RESUMO

The static x-ray imager at the National Ignition Facility is a pinhole camera using a CCD detector to obtain images of Hohlraum wall x-ray drive illumination patterns seen through the laser entrance hole (LEH). Carefully chosen filters, combined with the CCD response, allow recording images in the x-ray range of 3-5 keV with 60 µm spatial resolution. The routines used to obtain the apparent size of the backlit LEH and the location and intensity of beam spots are discussed and compared to predictions. A new soft x-ray channel centered at 870 eV (near the x-ray peak of a 300 eV temperature ignition Hohlraum) is discussed.

6.
Ground Water ; 39(2): 230-8, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11286070

RESUMO

A rapid-screening technique was developed to identify lithologies that best disperse artificial recharge via surface infiltration and minimize effects on ground water chemistry. The technique prospectively evaluates basin infiltration rates and water chemistry influences by integrating geotechnical, hydraulic, and water quality data with column test data and numerical modeling. The technique was validated using field data collected from surface infiltration basins designed to recharge ground water pumped from the Pipeline pit gold mine in Nevada. Observed recharge rates at these infiltration sites correlated most significantly with depth to groundwater, with basins in coarse-grained lithologies performing better (0.45 to 0.85 m/day) than those with fine-grained layers (< 0.30 m/day). Observed water quality resulting from leaching of the previously unsaturated vadose zone showed a transitory (< six months) increase in solute concentrations followed by a decrease to baseline conditions, a phenomenon also observed in column tests that leached native soils with local ground water. Leaching of fine-grained soils with evaporites resulted in greater solute concentrations (TDS > 2000 mg/L) than coarse-grained soils (< 1200 mg/L). The results of HYDRUS_2D simulations using the accumulated data as input were in agreement with observed ground water chemistry downgradient of the infiltration basins for a variety of lithologies. Sites for infiltration basins can be rapidly screened to include areas with greatest depth to groundwater and in coarsest alluvial sediments, and impact to ground water chemistry can be reliably predicted using computer modeling and column test results.


Assuntos
Água Doce/química , Geologia , Movimentos da Água , Simulação por Computador , Filtração , Fenômenos Geológicos , Nevada , Solo , Purificação da Água/métodos
7.
Nurs Clin North Am ; 35(2): 557-68, 2000 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10873268

RESUMO

For many nurses, the first step toward becoming a nurse researcher is to obtain help to develop and conduct research that documents outcomes of their novel innovation. These opportunities to engage in health services research often require collaborating with trained researchers who may not have clinical backgrounds. Collaboration generates learning and sharing processes that can be rewarding on many levels. To understand the realities of the collaboration process, this article provides a case study as the authors recount their experiences.


Assuntos
Pesquisa em Enfermagem Clínica/organização & administração , Pesquisa sobre Serviços de Saúde/organização & administração , Doença Crônica , Pesquisa em Enfermagem Clínica/tendências , Comportamento Cooperativo , Humanos
8.
Appl Environ Microbiol ; 52(3): 479-83, 1986 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3532954

RESUMO

Water samples were collected from 71 public drinking-water supply wells in the Tucson, Ariz., basin. Virus decay rates in the water samples were determined with MS-2 coliphage as a model virus. The correlations between the virus decay rates and the sample locations were shown by fitting a spherical model to the experimental semivariogram. Kriging, a geostatistical technique, was used to calculate virus decay rates at unsampled locations by using the known values at nearby wells. Based on the regional characteristics of groundwater flow and the kriged estimates of virus decay rates, a contour map of the area was constructed. The map shows the variation in separation distances that would have to be maintained between wells and sources of contamination to afford similar degrees of protection from viral contamination of the drinking water in wells throughout the basin.


Assuntos
Colífagos/crescimento & desenvolvimento , Esgotos , Microbiologia da Água , Escherichia coli , Fenômenos Geológicos , Geologia , Humanos , Análise de Regressão , Estatística como Assunto , Temperatura , Abastecimento de Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...