1.
Magn Reson Med ; 91(1): 39-50, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796151

RESUMO

PURPOSE: To explore the potential of 3T deuterium metabolic imaging (DMI) using a birdcage 2 H radiofrequency (RF) coil in both healthy volunteers and patients with central nervous system (CNS) lesions. METHODS: A modified gradient filter, home-built 2 H volume RF coil, and spherical k-space sampling were employed in a three-dimensional chemical shift imaging acquisition to obtain high-quality whole-brain metabolic images of 2 H-labeled water and glucose metabolic products. These images were acquired in a healthy volunteer and three subjects with CNS lesions of varying pathologies. Hardware and pulse sequence experiments were also conducted to improve the signal-to-noise ratio of DMI at 3T. RESULTS: The ability to quantify local glucose metabolism in correspondence to anatomical landmarks across patients with varying CNS lesions is demonstrated, and increased lactate is observed in one patient with the most active disease. CONCLUSION: DMI offers the potential to examine metabolic activity in human subjects with CNS lesions with DMI at 3T, promising for the potential of the future clinical translation of this metabolic imaging technique.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Humanos , Deutério , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Razão Sinal-Ruído , Glucose
2.
Magn Reson Med ; 75(3): 973-84, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25946547

RESUMO

PURPOSE: MRS of hyperpolarized [2-(13)C]pyruvate can be used to assess multiple metabolic pathways within mitochondria as the (13)C label is not lost with the conversion of pyruvate to acetyl-CoA. This study presents the first MR spectroscopic imaging of hyperpolarized [2-(13)C]pyruvate in glioma-bearing brain. METHODS: Spiral chemical shift imaging with spectrally undersampling scheme (1042 Hz) and a hard-pulse excitation was exploited to simultaneously image [2-(13)C]pyruvate, [2-(13)C]lactate, and [5-(13)C]glutamate, the metabolites known to be produced in brain after an injection of hyperpolarized [2-(13)C]pyruvate, without chemical shift displacement artifacts. A separate undersampling scheme (890 Hz) was also used to image [1-(13)C]acetyl-carnitine. Healthy and C6 glioma-implanted rat brains were imaged at baseline and after dichloroacetate administration, a drug that modulates pyruvate dehydrogenase kinase activity. RESULTS: The baseline metabolite maps showed higher lactate and lower glutamate in tumor as compared to normal-appearing brain. Dichloroacetate led to an increase in glutamate in both tumor and normal-appearing brain. Dichloroacetate-induced %-decrease of lactate/glutamate was comparable to the lactate/bicarbonate decrease from hyperpolarized [1-(13)C]pyruvate studies. Acetyl-carnitine was observed in the muscle/fat tissue surrounding the brain. CONCLUSION: Robust volumetric imaging with hyperpolarized [2-(13)C]pyruvate and downstream products was performed in glioma-bearing rat brains, demonstrating changes in mitochondrial metabolism with dichloroacetate.


Assuntos
Neoplasias Encefálicas/patologia , Isótopos de Carbono/metabolismo , Glioma/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Ácido Pirúvico/metabolismo , Animais , Encéfalo/metabolismo , Encéfalo/patologia , Isótopos de Carbono/química , Masculino , Ácido Pirúvico/química , Ratos , Ratos Wistar , Processamento de Sinais Assistido por Computador
3.
Magn Reson Med ; 71(6): 2051-8, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23878057

RESUMO

PURPOSE: In contrast to [1-(13) C]pyruvate, hyperpolarized [2-(13) C]pyruvate permits the ability to follow the (13) C label beyond flux through pyruvate dehydrogenase complex and investigate the incorporation of acetyl-coenzyme A into different metabolic pathways. However, chemical shift imaging (CSI) with [2-(13) C]pyruvate is challenging owing to the large spectral dispersion of the resonances, which also leads to severe chemical shift displacement artifacts for slice-selective acquisitions. METHODS: This study introduces a sequence for three-dimensional CSI of [2-(13) C]pyruvate using spectrally selective excitation of limited frequency bands containing a subset of metabolites. Dynamic CSI data were acquired alternately from multiple frequency bands in phantoms for sequence testing and in vivo in rat heart. RESULTS: Phantom experiments verified the radiofrequency pulse design and demonstrated that the signal behavior of each group of resonances was unaffected by excitation of the other frequency bands. Dynamic three-dimensional (13) C CSI data demonstrated the sequence capability to image pyruvate, lactate, acetylcarnitine, glutamate, and acetoacetate, enabling the analysis of organ-specific spectra and metabolite time courses. CONCLUSIONS: The presented method allows CSI of widely separated resonances without chemical shift displacement artifact, acquiring multiple frequency bands alternately to obtain dynamic time-course information. This approach enables robust imaging of downstream metabolic products of acetyl-coenzyme A with hyperpolarized [2-(13) C]pyruvate.


Assuntos
Imageamento Tridimensional , Espectroscopia de Ressonância Magnética/métodos , Miocárdio/metabolismo , Piruvatos/metabolismo , Acetoacetatos/metabolismo , Acetilcarnitina/metabolismo , Animais , Isótopos de Carbono/metabolismo , Meios de Contraste/química , Ácido Glutâmico/metabolismo , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Lactatos/metabolismo , Masculino , Meglumina/química , Compostos Organometálicos/química , Imagens de Fantasmas , Ratos , Ratos Wistar , Fatores de Tempo
4.
Environ Geochem Health ; 34(2): 279-88, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21983883

RESUMO

Simulated lung fluids are solutions designed to mimic the composition of human interstitial lung fluid as closely as possible. Analysis of mineral dusts using such solutions has been used to evaluate the respiratory bioaccessibility of various elements for which solubility in the lungs is a primary determinant of reactivity. The objective of this study was to employ simulated lung fluid analysis to investigate the respiratory bioaccessibility of nickel in soils. Current occupational guidelines in Australia regulate nickel compounds in terms of water solubility, though this may not be an accurate estimation of the total nickel that will dissociate in the lungs. Surface soils were collected from the city of Kalgoorlie in Western Australia, the site of an operational nickel smelter and metal mining activities. The fraction of the samples less than 10 µm was extracted from the soil, and it was this sub-10-µm fraction that was found to hold most of the total nickel present in the soil. The fine fraction was analyzed using a simulated lung fluid (modified Gamble's solution) to isolate the nickel phases soluble in the lungs. In addition, a sequential extraction was employed to compare the bioaccessible fraction to those dissolved from different binding forms in the soil. In all samples, the simulated lung fluid extracted more nickel than the two weakest leaches of the sequential extraction combined, providing a more representative nickel bioaccessibility value than the current water leach method.


Assuntos
Exposição por Inalação , Pulmão/metabolismo , Modelos Biológicos , Níquel/metabolismo , Poluentes do Solo/metabolismo , Secreções Corporais/metabolismo , Monitoramento Ambiental , Mineração , Medição de Risco , Solo/química , Solubilidade
5.
Magn Reson Med ; 63(4): 1050-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20373406

RESUMO

MR acoustic radiation force imaging provides a promising method to monitor therapeutic ultrasound treatments. By measuring the displacement induced by the acoustic radiation force, MR acoustic radiation force imaging can locate the focal spot, without a significant temperature rise. In this work, the encoding gradient for MR acoustic radiation force imaging is optimized to achieve an enhanced accuracy and precision of the displacement measurement. By analyzing the sources of artifacts, bulk motion and eddy currents are shown to introduce errors to the measurement, and heavy diffusion-weighting is shown to result in noisy displacement maps. To eliminate these problems, a new encoding scheme is proposed, which utilizes a pair of bipolar gradients. Improved precision is achieved with robustness against bulk motion and background phase distortion, and improved accuracy is achieved with reduced diffusion-weighting and optimized encoding pulse width. The experiment result shows that the signal-to-noise ratio can be enhanced by more than 2-fold. These significant improvements are obtained at no cost of scan time or encoding sensitivity, enabling the detection of a displacement less than 0.l microm in a gel phantom with MR acoustic radiation force imaging.


Assuntos
Acústica , Imagem de Difusão por Ressonância Magnética/métodos , Técnicas de Imagem por Elasticidade/métodos , Terapia por Ultrassom/métodos , Algoritmos , Artefatos , Modelos Lineares , Imagens de Fantasmas
6.
J Magn Reson Imaging ; 17(1): 131-5, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12500282

RESUMO

PURPOSE: To evaluate the acute lesion created by cryosurgery with diffusion-weighted magnetic resonance imaging (DWI). MATERIALS AND METHODS: The appearance of the acute cryolesion was evaluated in four canine prostates DWI after they were warmed to original body temperature. The prostates were excised, stained with triphenyl tetrazolium chloride (TTC), photographed, prepared for hematoxylin and eosin (H&E) staining, and examined under a light microscope. RESULTS: A marked decrease in apparent diffusion coefficient of 38% was evident in the center of the previously frozen tissue, but not in all of the previously frozen tissue. Histologic results confirm differences between the iceball core and the periphery of the iceball, which have markedly different imaging characteristics on DWI. CONCLUSION: The core of the previously frozen tissue has a reduced apparent diffusion coefficient (ADC) compared to the periphery of the previously frozen tissue and previously unfrozen tissue.


Assuntos
Imagem de Difusão por Ressonância Magnética , Próstata/anatomia & histologia , Animais , Criocirurgia , Cães , Masculino