Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Aerosp Med Hum Perform ; 94(10): 770-779, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37726913

RESUMO

INTRODUCTION: Adding noise to a system to improve a weak signal's detectability is known as stochastic resonance (SR). SR has been shown to improve sensory perception and cognitive performance in certain individuals, but it is unknown whether this performance improvement can translate to meaningful macrocognitive enhancements in performance for complex, operational tasks.OBJECTIVE: We investigated human operator performance in a lunar landing simulation while applying auditory white noise and/or noisy galvanic vestibular stimulation.METHODS: We measured performance (N = 16 subjects) while completing simulation trials in our Aerospace Research Simulator. Trials were completed with and without the influence of auditory white noise, noisy galvanic vestibular stimulation, and both simultaneously in a multimodal fashion. Performance was observed holistically and across subdimensions of the task, which included flight skill and perception. Subjective mental workload was collected after completing four trials in each treatment.RESULTS: We did not find broad operator improvement under the influence of noise, but a significant interaction was identified between subject and noise treatment, indicating that some subjects were impacted by additive noise. We also found significant interactions between subject and noise treatment in performance subdimensions of flight skill and perception. We found no significant main effects on mental workload.CONCLUSIONS: This study investigated the utility of using additive sensory noise to induce SR for complex tasks. While SR has been shown to improve aspects of performance, our results suggest additive noise does not yield operational performance changes for a broad population, but specific individuals may be affected.Sherman SO, Shen Y-Y, Gutierrez-Mendoza D, Schlittenhart M, Watson C, Clark TK, Anderson AP. Additive sensory noise effects on operator performance in a lunar landing simulation. Aerosp Med Hum Perform. 2023; 94(10):770-779.


Assuntos
Lua , Vibração , Humanos , Simulação por Computador , Carga de Trabalho
2.
J Physiol ; 594(12): 3423-37, 2016 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-26836470

RESUMO

KEY POINTS: Reductions in cerebral blood flow (CBF) may be implicated in the development of neuromuscular fatigue; however, the contribution from hypocapnic-induced reductions (i.e. P ETC O2) in CBF versus reductions in CBF per se has yet to be isolated. We assessed neuromuscular function while using indomethacin to selectively reduce CBF without changes in P ETC O2 and controlled hyperventilation-induced hypocapnia to reduce both CBF and P ETC O2. Increased corticospinal excitability appears to be exclusive to reductions in P ETC O2 but not reductions in CBF, whereas sub-optimal voluntary output from the motor cortex is moderately associated with decreased CBF independent of changes in P ETC O2. These findings suggest that changes in CBF and P ETC O2 have distinct roles in modulating neuromuscular function. ABSTRACT: Although reductions in cerebral blood flow (CBF) may be involved in central fatigue, the contribution from hypocapnia-induced reductions in CBF versus reductions in CBF per se has not been isolated. This study examined whether reduced arterial PCO2 (P aC O2), independent of concomitant reductions in CBF, impairs neuromuscular function. Neuromuscular function, as indicated by motor-evoked potentials (MEPs), maximal M-wave (Mmax ) and cortical voluntary activation (cVA) of the flexor carpi radialis muscle during isometric wrist flexion, was assessed in ten males (29 ± 10 years) during three separate conditions: (1) cyclooxygenase inhibition using indomethacin (Indomethacin, 1.2 mg kg(-1) ) to selectively reduce CBF by 28.8 ± 10.3% (estimated using transcranial Doppler ultrasound) without changes in end-tidal PCO2 (P ETC O2); (2) controlled iso-oxic hyperventilation-induced reductions in P aC O2 (Hypocapnia), P ETC O2  = 30.1 ± 4.5 mmHg with related reductions in CBF (21.7 ± 6.3%); and (3) isocapnic hyperventilation (Isocapnia) to examine the potential direct influence of hyperventilation-mediated activation of respiratory control centres on CBF and changes in neuromuscular function. Change in MEP amplitude (%Mmax ) from baseline was greater in Hypocapnia tha in Isocapnia (11.7 ± 9.8%, 95% confidence interval (CI) [2.6, 20.7], P = 0.01) and Indomethacin (13.3 ± 11.3%, 95% CI [2.8, 23.7], P = 0.01) with a large Cohen's effect size (d ≥ 1.17). Although not statistically significant, cVA was reduced with a moderate effect size in Indomethacin (d = 0.7) and Hypocapnia (d = 0.9) compared to Isocapnia. In summary, increased corticospinal excitability - as reflected by larger MEP amplitude - appears to be exclusive to reduced P aC O2, but not reductions in CBF per se. Sub-optimal voluntary output from the motor cortex is moderately associated with decreased CBF, independent of reduced P aC O2.


Assuntos
Córtex Cerebral/fisiologia , Circulação Cerebrovascular , Hiperventilação/fisiopatologia , Hipocapnia/fisiopatologia , Nervo Mediano/fisiologia , Adulto , Circulação Cerebrovascular/efeitos dos fármacos , Inibidores de Ciclo-Oxigenase/farmacologia , Potencial Evocado Motor/efeitos dos fármacos , Humanos , Indometacina/farmacologia , Masculino , Músculo Esquelético/efeitos dos fármacos , Músculo Esquelético/fisiopatologia , Adulto Jovem
3.
ACS Comb Sci ; 17(6): 381-91, 2015 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-25970448

RESUMO

Combinatorial synthesis has proven extremely effective in screening for new battery materials for Li-ion battery electrodes. Here, a study in the Li-Ni-Mn-Co-O system is presented, wherein samples with nearly 800 distinct compositions were prepared using a combinatorial and high-throughput method to screen for single-phase materials of high interest as next generation positive electrode materials. X-ray diffraction is used to determine the crystal structure of each sample. The Gibbs' pyramid representing the pseudoquaternary system was studied by making samples within three distinct pseudoternary planes defined at fractional cobalt metal contents of 10%, 20%, and 30% within the Li-Ni-Mn-Co-O system. Two large single-phase regions were observed in the system: the layered region (ordered rocksalt) and cubic spinel region; both of which are of interest for next-generation positive electrodes in lithium-ion batteries. These regions were each found to stretch over a wide range of compositions within the Li-Ni-Mn-Co-O pseudoquaternary system and had complex coexistence regions existing between them. The sample cooling rate was found to have a significant effect on the position of the phase boundaries of the single-phase regions. The results of this work are intended to guide further research by narrowing the composition ranges worthy of study and to illustrate the broad range of applications where solution-based combinatorial synthesis can have significant impact.


Assuntos
Cobalto/química , Técnicas de Química Combinatória/métodos , Lítio/química , Manganês/química , Níquel/química , Óxidos/química , Fontes de Energia Elétrica , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...