Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Ayub Med Coll Abbottabad ; 22(2): 134-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21702287

RESUMO

BACKGROUND: In Dilated cardiomyopathy the heart is enlarged and ventricles are dilated. Gated myocardial perfusion single photon emission computed tomography is considered state of the art for myocardial perfusion imaging. A retrospective analysis was conducted to evaluate patients with dilated cardiomyopathy with Tc-99m sestamibi gated myocardial perfusion single photon emission computed tomography to evaluate its clinical utility. METHODS: A 10 year retrospective medical record review was done from 1991 to 2001 at Wake Forest University, North Carolina, USA. Eligibility criteria included a diagnosis of dilated cardiomyopathy and availability of coronary angiography and Tc-99m sestamibi cardiac imaging results. 26 cases were selected for the final review and inclusion in the study. The study was done with standard protocols for cardiac sestamibi imaging. RESULTS: A total of 26 cases were included in the final analysis. Cases were divided into two main groups. Group-A included 16 patients with no correlation between Tc-99m sestamibi and cardiac catheterisation reports. Group-B included 10 patients with good correlation between the above tests. There were no significant differences between the left ventricular ejection fraction, angina history, sex distribution and diabetic status between the two groups. We applied Wilcoxon Signed Rank Test and z-test to quantify the difference between the two groups. Data was tabulated and z-test was performed. The calculated p-value was <0.0001. This is significantly less than the tabulated p-value at 5% level of significance, i.e., 1.96. Significant differences exist between Group-A and Group-B. CONCLUSION: Tc-99m sestamibi is an excellent agent for investigating myocardial perfusion in dilated cardiomyopathy. The reversible and fixed perfusion defects (small to medium sized) seen in dilated cardiomyopathy after performance of Tc-99m sestamibi gated single photon emission computed tomography imaging may not be due to coronary artery disease. Tc-99m sestamibi single photon emission computed tomography is useful as a routine non-invasive technique to evaluate myocardial function in dilated cardiomyopathy.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Cardiomiopatia Dilatada/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Adulto , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/fisiopatologia , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Int J Radiat Oncol Biol Phys ; 58(3): 694-7, 2004 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-14967422

RESUMO

PURPOSE: A prospective, single institution study was conducted to evaluate the role of positron emission tomography with fluoro-deoxyglucose (FDG) before and after definitive radiation therapy for patients with head-and-neck cancer. Correlation with CT or MRI imaging and pathologic findings at the time of planned neck dissection was made. METHODS AND MATERIALS: Twelve patients with AJCC Stages III-IV cancer of the head and neck received CT or MRI and PET imaging before treatment with definitive radiation therapy. One month after completion of treatment, repeat CT or MRI and PET imaging was obtained. All images were reviewed independently by radiologists who were blind to the results of the other modality. Patients then underwent planned neck dissection. Pathologic correlation with posttreatment scans allowed calculation of the sensitivity, specificity, negative predictive value, and the positive predictive value for both CT/MRI and PET. RESULTS: Comparison of CT/MRI to PET obtained before definitive RT revealed both primary tumor and nodal disease were detected by both modalities in all cases where primary tumor was known. After RT, comparison of CT/MRI imaging to findings of neck dissection revealed a sensitivity of 90%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 50%. Comparison of PET imaging with pathologic findings demonstrated sensitivity of 45%, specificity of 100%, positive predictive value of 100%, and a negative predictive value of 14%. CONCLUSIONS: In this small series of patients, the presence of a positive PET 1 month after RT accurately indicated the presence of residual disease in all cases; however, a negative PET indicated absence of disease in only 14%. Further investigation is warranted before FDG-PET should be used to determine whether post-RT neck dissection should be omitted.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Esvaziamento Cervical , Tomografia Computadorizada de Emissão , Carcinoma de Células Escamosas/cirurgia , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/cirurgia , Humanos , Metástase Linfática , Imageamento por Ressonância Magnética , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
3.
Clin Nucl Med ; 28(12): 955-60, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14663315

RESUMO

At our tertiary care institution, a targeted minimally invasive parathyroidectomy (MIP) is the preferred surgical procedure for primary hyperparathyroidism. Similar to unilateral neck exploration (UNE), preoperative scintigraphic localization of the adenoma in relation to the midline is required. However, in contrast to the abbreviated standard incision for UNE, 2 distinct incision sites, 1 medial and 1 lateral, are available on each side with MIP. The incision site is ultimately chosen based on scintigraphic determination of the adenoma's vascular origin to facilitate ligation and removal. Unfortunately, the scintigraphic location of a parathyroid adenoma does not necessarily reflect the site of its vascular origin. We reviewed our database to identify factors that accurately predict the site of vascular origin of parathyroid adenomas. A retrospective chart review was performed on 125 patients who underwent Tc-99m sestamibi scintigraphy and parathyroidectomy. Scintigraphic localization, surgical findings, and histopathology were recorded. Preoperative image interpretations that were discordant with operative findings were independently reviewed. Scintigraphy identified the presence of an adenoma in 105 of 118 patients (89%) with primary hyperparathyroidism. In 17 of the 105 cases (16%), the scintigraphic interpretation did not accurately reflect the site of superior or inferior vascular origin seen at surgery. In many discordant cases, anterior images were insufficient for determining the vascular origin. The posterior displacement of an adenoma in relation to the thyroid on early lateral images was often critical in determining the superior or inferior vascular origin. Scintigraphic determination of the superior or inferior vascular origin of a parathyroid adenoma directs incision placement for MIP. Imaging protocols should include early lateral images when localizing parathyroid adenomas before minimally invasive parathyroidectomy.


Assuntos
Adenoma/diagnóstico por imagem , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/cirurgia , Paratireoidectomia/métodos , Cuidados Pré-Operatórios/métodos , Cirurgia Assistida por Computador/métodos , Tomografia Computadorizada de Emissão/métodos , Adenoma/irrigação sanguínea , Adenoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/patologia , Glândulas Paratireoides/irrigação sanguínea , Glândulas Paratireoides/patologia , Guias de Prática Clínica como Assunto , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
Am Surg ; 69(6): 478-83; discussion 483-4, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12852504

RESUMO

Minimally invasive parathyroidectomy (MIP) has become the preferred surgical treatment for selected patients diagnosed with primary hyperparathyroidism (PHPT) at our tertiary-care center. Preoperative scintigraphy establishes the position of a parathyroid adenoma, dictates the incision site, and can minimize incision size and consequent tissue dissection. We reviewed our database and sought to identify factors that led to discordant preoperative imaging and operative findings and to assess the effect of experience on these findings. A retrospective review was performed on all patients with biochemically proven PHPT who underwent Tc-99m sestamibi scintigraphy and surgical intervention. Patient demographics, date of surgical intervention, scintigraphic localization, surgical findings, pre- and postoperative biochemical markers, histopathology, coexisting thyroid pathology, and 6-month follow up were recorded. Preoperative images that were discordant with operative findings were independently reviewed. Parathyroid scintigraphy was performed on 125 consecutive patients for PHPT between November 1999 and January 2002. Seventy-six patients had MIPs, 35 had standard cervical explorations, 11 had MIPs that were converted to standard cervical explorations, and three had surgery directed to an ectopic location. At 6-month follow-up 98.4 per cent were cured. Preoperative imaging and surgical findings were ipsilateral and concordant in 105 of 118 (89%) patients with parathyroid adenoma. The anatomic origin of an adenoma was predicted in only 83 of 118 (68%) patients. Most of the inaccurate scintigraphy readings occurred during the first 13 of the 26 months that MIPs were performed at our institution. Only two discordant cases occurred during the last 9 months of this period. Biochemical markers, prior neck operation, and concomitant thyroid pathology had no correlation with imaging sensitivity. Scintigraphic interpretation of smaller adenomas was less reliable; discordant cases were more common in small adenomas. Communication between endocrine surgeons and nuclear medicine physicians about the MIP technique and anatomic orientation of adenomas led to better scintigraphic localization as experience increased. Now that MIP by skilled endocrine surgeons is becoming the favored treatment for PHPT experienced nuclear medicine physicians may be the most important factor to achieve maximum success.


Assuntos
Adenoma/cirurgia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia/métodos , Tomografia Computadorizada de Emissão de Fóton Único/normas , Adenoma/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cirurgia Geral/normas , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias das Paratireoides/diagnóstico por imagem , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tecnécio Tc 99m Sestamibi
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA