Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ecology ; 105(3): e4194, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37882101

RESUMO

A major restriction in predicting plant community response to future climate change is a lack of long-term data needed to properly assess species and community response to climate and identify a baseline to detect climate anomalies. Here, we use a 106-year dataset on a Sonoran Desert plant community to test the role of extreme temperature and precipitation anomalies on community dynamics at the decadal scale and over time. Additionally, we tested the climate sensitivity of 39 desert plant species and whether sensitivity was associated with growth form, longevity, geographic range, or local dominance. We found that desert plant communities had shifted directionally over the 106 years, but the climate had little influence on this directional change primarily due to nonlinear shifts in precipitation anomalies. Decadal-scale climate had the largest impact on species richness, species relative density, and total plant cover, explaining up to 26%, 45%, and 55% of the variance in each, respectively. Drought and the interaction between the frequency of freeze events and above-average summer precipitation were among the most influential climate factors. Increased drought frequency and wetter periods with frequent freeze events led to larger reductions in total plant cover, species richness, and the relative densities of dominant subshrubs Ambrosia deltoidea and Encelia farinosa. More than 80% of the tested species were sensitive to climate, but sensitivity was not associated with a species' local dominance, longevity, geographic range, or growth form. Some species appear to exhibit demographic buffering, where when they have a higher sensitivity to drought, they also tend to have a higher sensitivity to favorable (i.e., wetter and hotter) conditions. Overall, our results suggest that, while decadal-scale climate variation substantially impacts these desert plant communities, directional change in temperature over the last century has had little impact due to the relative importance of precipitation and drought. With projections of increased drought in this region, we may see reductions in total vegetation cover and species richness due to the loss of species, possibly through a breakdown in their ability to demographically buffer climatic variation, potentially changing community dynamics through a change in facilitative and competitive processes.


Assuntos
Clima Desértico , Plantas , Temperatura Alta , Temperatura , Estações do Ano
2.
Cornea ; 35(9): 1234-41, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27362877

RESUMO

PURPOSE: To evaluate crosslinking of cornea in vivo using green light activation of Rose Bengal (RGX) and assess potential damaging effects of the green light on retina and iris. METHODS: Corneas of Dutch belted rabbits were de-epithelialized, then stained with Rose Bengal and exposed to green light, or not further treated. Corneal stiffness was measured by uniaxial tensiometry. Re-epithelialization was assessed by fluorescein fluorescence. Keratocytes were counted on hematoxylin and eosin (H&E)-stained sections, and iris cell damage was assessed by lactate dehydrogenase staining. Thermal effects on the blood-retinal barrier (BRB) were assessed by fluorescein angiography and those on photoreceptors, retinal pigment epithelium (RPE), and choriocapillaris by light microscopy and transmission electron microscopy. RESULTS: RGX (10-min irradiation; 150 J/cm) increased corneal stiffness 1.9-fold on day 1 (1.25 ± 0.21 vs. 2.38 ± 0.59 N/mm; P = 0.036) and 2.8-fold compared with controls on day 28 (1.70 ± 0.74 vs. 4.95 ± 1.86 N/mm; P = 0.003). Keratocytes decreased only in the anterior stroma on day 1 (24.0 ± 3.0 vs. 3.67 ± 4.73, P = 0.003) and recovered by day 28 (37.7 ± 8.9 vs. 34.5 ± 2.4, P = 0.51). Iris cells were not thermally damaged. No evidence of BRB breakdown was detected on days 1 or 28. Retina from RGX-treated eyes seemed normal with RPE cells showing intact nuclei shielded apically by melanosomes, morphologically intact photoreceptor outer segments, normal outer nuclear layer thickness, and choriocapillaris containing intact erythrocytes. CONCLUSIONS: The substantial corneal stiffening produced by RGX together with the lack of significant effects on keratocytes and no evidence for retina or iris damage suggest that RGX-initiated corneal crosslinking may be a safe, rapid, and effective treatment.


Assuntos
Substância Própria/efeitos dos fármacos , Reagentes de Ligações Cruzadas , Lasers de Estado Sólido , Fotoquimioterapia , Fármacos Fotossensibilizantes/farmacologia , Rosa Bengala/farmacologia , Animais , Barreira Hematorretiniana/efeitos da radiação , Contagem de Células , Colágeno/metabolismo , Ceratócitos da Córnea/patologia , Substância Própria/metabolismo , Angiofluoresceinografia , Iris/efeitos da radiação , Masculino , Microscopia Eletrônica de Transmissão , Coelhos , Reepitelização
3.
Am J Bot ; 102(1): 85-91, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25587151

RESUMO

UNLABELLED: • PREMISE OF STUDY: Accurate demographic information about long-lived plant species is important for understanding responses to large-scale disturbances, including climate change. It is challenging to obtain these data from desert perennial plants because seedling establishment is exceptionally rare, and estimates of survival are lacking for their vulnerable early stages. Desert wildfires, urbanization, and climate change influence the persistence of the long-lived Yucca brevifolia. Quantitative demographic attributes are crucial for understanding how populations will respond to disturbances and where populations will recede or advance under future climate scenarios.• METHODS: We measured survival in a cohort of 53 pre-reproductive Y. brevifolia at Yucca Flat, Nevada, USA, for 22 yr and recorded their growth, nurse-plant relationships, and herbivory.• KEY RESULTS: Herbivory by black-tailed jackrabbits (Lepus californicus) caused severe losses of plants during the first and second years (45% and 31%, respectively). Surviving plants experienced <2.5% annual mortality. Survival for the population was 19% over 22 yr. Plants <25 cm in height had lower life expectancy. Average growth rate (± SD) for plants that survived to the last census was 3.12 ± 1.96 cm yr(-1), and growth rates were positively associated with precipitation. Thirty-year-old Y. brevifolia had not yet reproduced.• CONCLUSIONS: A rare establishment event for Y. brevifolia during 1983-1984, triggered by above-average summer rainfall, provided a unique opportunity to track early survival and growth. Infrequent but acute episodes of herbivory during drought influenced demography for decades. Variability in survival among young Y. brevifolia indicates that size-dependent demographic variables will improve forecasts for this long-lived desert species under predicted regional climate change.


Assuntos
Meio Ambiente , Yucca/fisiologia , Mudança Climática , Chuva , Reprodução , Estações do Ano , Yucca/crescimento & desenvolvimento
4.
Proc Natl Acad Sci U S A ; 107(50): 21263-70, 2010 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-21149727

RESUMO

Increasing human appropriation of freshwater resources presents a tangible limit to the sustainability of cities, agriculture, and ecosystems in the western United States. Marc Reisner tackles this theme in his 1986 classic Cadillac Desert: The American West and Its Disappearing Water. Reisner's analysis paints a portrait of region-wide hydrologic dysfunction in the western United States, suggesting that the storage capacity of reservoirs will be impaired by sediment infilling, croplands will be rendered infertile by salt, and water scarcity will pit growing desert cities against agribusiness in the face of dwindling water resources. Here we evaluate these claims using the best available data and scientific tools. Our analysis provides strong scientific support for many of Reisner's claims, except the notion that reservoir storage is imminently threatened by sediment. More broadly, we estimate that the equivalent of nearly 76% of streamflow in the Cadillac Desert region is currently appropriated by humans, and this figure could rise to nearly 86% under a doubling of the region's population. Thus, Reisner's incisive journalism led him to the same conclusions as those rendered by copious data, modern scientific tools, and the application of a more genuine scientific method. We close with a prospectus for reclaiming freshwater sustainability in the Cadillac Desert, including a suite of recommendations for reducing region-wide human appropriation of streamflow to a target level of 60%.


Assuntos
Clima Desértico , Água Doce , Abastecimento de Água , Agricultura/métodos , Conservação dos Recursos Naturais , Ecossistema , Humanos , Crescimento Demográfico , Sudoeste dos Estados Unidos , Movimentos da Água
5.
Invest Ophthalmol Vis Sci ; 51(2): 857-63, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19815733

RESUMO

PURPOSE: To evaluate the optical characteristics of the Boston Keratoprosthesis (KPro), identify glare sources, evaluate possible glare control, and examine the benefit of implantation when the fellow eye has normal vision. METHODS: Computed and optical-bench-measured point spread function (PSF) and glare sources were compared. A translucent plastic cornea was used to determine the impact of glare caused by scatter in the cornea and its control with a dark-iris tinted contact lens. The effect of glare in implanted eyes was measured with a brightness acuity test (BAT), with and without the dark-iris contact lens. Computed and measured visual fields were compared. Stereopsis was measured in patients with an intact fellow eye. RESULTS: Computed and measured modulation transfer functions for the KPro were found to be very close to the diffraction limit. Both the model-eye measurements and patients' BAT glare responses identified that the hazy corneal graft surrounding the KPro is the main source of glare and can be controlled with a dark-iris contact lens. The lid effectively blocks the light that would be scattered in the hazy cornea of patients in whom the type II KPro was implanted. An intact fellow eye remains the dominant eye, with better acuity, and the KPro eye supports only minimal stereo ability and does not expand the binocular visual field. CONCLUSIONS: Glare can be reduced significantly with the use of a contact lens with a dark iris. Implanting the KPro in a patient whose fellow eye has normal or near normal vision does not seem to improve visual function.


Assuntos
Órgãos Artificiais , Córnea , Ofuscação , Óptica e Fotônica , Próteses e Implantes , Espalhamento de Radiação , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Doenças da Córnea/cirurgia , Percepção de Profundidade/fisiologia , Humanos , Luz , Pessoa de Meia-Idade , Modelos Biológicos , Desenho de Prótese , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
6.
Behav Brain Funct ; 5: 46, 2009 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-19995444

RESUMO

BACKGROUND: Many studies have reported beneficial effects from the application of near-infrared (NIR) light photobiomodulation (PBM) to the body, and one group has reported beneficial effects applying it to the brain in stroke patients. We have reported that the measurement of a patient's left and right hemispheric emotional valence (HEV) may clarify data and guide lateralized treatments. We sought to test whether a NIR treatment could 1. improve the psychological status of patients, 2. show a relationship between immediate psychological improvements when HEV was taken into account, and 3. show an increase in frontal pole regional cerebral blood flow (rCBF), and 4. be applied without side effects. METHODS: We gave 10 patients, (5 M/5 F) with major depression, including 9 with anxiety, 7 with a past history of substance abuse (6 with an opiate abuse and 1 with an alcohol abuse history), and 3 with post traumatic stress disorder, a baseline standard diagnostic interview, a Hamilton Depression Rating Scale (HAM-D), a Hamilton Anxiety Rating Scale (HAM-A), and a Positive and Negative Affect Scale (PANAS). We then gave four 4-minute treatments in a random order: NIR to left forehead at F3, to right forehead at F4, and placebo treatments (light off) at the same sites. Immediately following each treatment we repeated the PANAS, and at 2-weeks and at 4-weeks post treatment we repeated all 3 rating scales. During all treatments we recorded total hemoglobin (cHb), as a measure of rCBF with a commercial NIR spectroscopy device over the left and the right frontal poles of the brain. RESULTS: At 2-weeks post treatment 6 of 10 patients had a remission (a score

7.
J Opt Soc Am A Opt Image Sci Vis ; 24(5): 1250-65, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17429471

RESUMO

After discussing the rationale and assumptions of the ANSI Z136.1-2000 Standard for protection of the human eye from laser exposure, we present the concise formulation of the exposure limits expressed as maximum permissible radiant exposure (in J/cm(2)) for light overfilling the pupil. We then translate the Standard to a form that is more practical for typical ophthalmic devices or in vision research situations, implementing the special qualifications of the Standard. The safety limits are then expressed as radiant power (watts) entering the pupil of the eye. Exposure by repetitive pulses is also addressed, as this is frequently employed in ophthalmic applications. Examples are given that will familiarize potential users with this format.


Assuntos
Segurança de Equipamentos/normas , Traumatismos Oculares/prevenção & controle , Guias como Assunto , Oftalmologia/instrumentação , Lesões por Radiação/prevenção & controle , Proteção Radiológica/normas , Radiometria/métodos , Análise de Falha de Equipamento/normas , Humanos , Doses de Radiação , Radiometria/normas , Estados Unidos
8.
Opt Lett ; 32(6): 659-61, 2007 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17308593

RESUMO

In vivo imaging of the mouse retina using visible and near infrared wavelengths does not achieve diffraction-limited resolution due to wavefront aberrations induced by the eye. Considering the pupil size and axial dimension of the eye, it is expected that unaberrated imaging of the retina would have a transverse resolution of 2 microm. Higher-order aberrations in retinal imaging of human can be compensated for by using adaptive optics. We demonstrate an adaptive optics system for in vivo imaging of fluorescent structures in the retina of a mouse, using a microelectromechanical system membrane mirror and a Shack-Hartmann wavefront sensor that detects fluorescent wavefront.


Assuntos
Angiofluoresceinografia/métodos , Aumento da Imagem/instrumentação , Lentes , Microscopia de Fluorescência/métodos , Retina/anatomia & histologia , Animais , Desenho de Equipamento , Análise de Falha de Equipamento , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
J Biomed Opt ; 11(4): 041126, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16965154

RESUMO

Scanning laser ophthalmoscopy (SLO) is a powerful imaging tool with specialized applications limited to research and ophthalmology clinics due in part to instrument size, cost, and complexity. Conversely, low-cost retinal imaging devices have limited capabilities in screening, detection, and diagnosis of diseases. To fill the niche between these two, a hand-held, nonmydriatic line-scanning laser ophthalmoscope (LSLO) is designed, constructed, and tested on normal human subjects. The LSLO has only one moving part and uses a novel optical approach to produce wide-field confocal fundus images. Imaging modes include multiwavelength illumination and live stereoscopic imaging with a split aperture. Image processing and display functions are controlled with two stacked prototype compact printed circuit boards. With near shot-noise limited performance, the digital LSLO camera requires low illumination power (<500 microW) at near-infrared wavelengths. The line-scanning principle of operation is examined in comparison to SLO and other imaging modes. The line-scanning approach produces high-contrast confocal images with nearly the same performance as a flying-spot SLO. The LSLO may significantly enhance SLO utility for routine use by ophthalmologists, optometrists, general practitioners, and also emergency medical personnel and technicians in the field for retinal disease detection and other diverse applications.


Assuntos
Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Microscopia Confocal/instrumentação , Oftalmoscópios , Processamento de Sinais Assistido por Computador/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Armazenamento e Recuperação da Informação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Vision Res ; 46(22): 3775-81, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16938334

RESUMO

Color matches made with a Nagel anomaloscope are used in the differentiation of color vision deficiencies. When these color matches are made over a wide range of retinal illuminances, the changes in the color match provide information about the regeneration kinetics and the absorption spectra of the middle- and long-wavelength cone photopigments. These steady-state color matches vary with a variety of conditions, and may have value in screening for eye disease. Recently, high-brightness LEDs have become available that allowed us to construct a LED-based, high-brightness anomaloscope. We used inexpensive, low-energy components to replicate an earlier instrument, getting a maximum retinal illuminance over 5.6 log Trolands.


Assuntos
Testes de Percepção de Cores/instrumentação , Defeitos da Visão Cromática/diagnóstico , Adaptação Ocular/fisiologia , Adulto , Idoso , Percepção de Cores/fisiologia , Defeitos da Visão Cromática/fisiopatologia , Eletrônica , Desenho de Equipamento , Feminino , Humanos , Luz , Masculino , Pessoa de Meia-Idade , Óptica e Fotônica , Projetos Piloto , Psicofísica , Reprodutibilidade dos Testes , Retina/fisiopatologia , Células Fotorreceptoras Retinianas Cones/fisiologia , Pigmentos da Retina/fisiologia
11.
Appl Opt ; 44(19): 4000-3, 2005 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-16004046

RESUMO

Ultrabright light emitting diodes (LEDs) are a new light source for visual psychophysics and microscopy. The new LEDs are intended primarily for room and exterior illumination, and the manufacturers' specifications are adequate for that. However, we use them as light sources in situations where a more complete characterization may be useful. For one set of LEDs we have measured the radiometric intensity and its distribution in space and wavelength, and we have tested for interactions of these variables and their dependence on driver configuration. We describe techniques for making these measurements and give a link to a simple calculator for converting among radiometric and photometric measures, as well as an evaluation of the safety considerations these very bright sources demand.


Assuntos
Eletroquímica/instrumentação , Análise de Falha de Equipamento/métodos , Iluminação , Fotometria/métodos , Radiometria/métodos , Eletroquímica/métodos , Desenho de Equipamento , Luz , Fotometria/instrumentação , Doses de Radiação , Semicondutores
12.
Appl Opt ; 43(28): 5330-3, 2004 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-15495423

RESUMO

We demonstrate a simple optical configuration that amplifies the usable stroke of a deformable mirror. By arranging for the wavefront to traverse the deformable mirror more than once, we correct it more than once. The experimental implementation of the idea demonstrates a doubling of 2.0 and 2.04 by two different means.

13.
Ophthalmology ; 111(7): 1368-79, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15234139

RESUMO

OBJECTIVE: To compare visual outcomes in eyes undergoing aberrometry-guided (InterWave) LASIK with those in eyes undergoing standard LASIK treatment based upon refractive measures. DESIGN: Single-center, comparative, interventional, consecutive case series. PARTICIPANTS: Four hundred two consecutive eyes undergoing LASIK were analyzed retrospectively. One group, 106 eyes undergoing primary LASIK and 224 eyes undergoing LASIK enhancement, was treated with standard LASIK treatment using a 5.5-mm optical zone, 1.5-mm transition zone laser with the settings determined by manifest refraction. The second group, 44 untreated (primary) eyes and 28 previously treated (enhancement) eyes, received a multipass, multistage treatment in which the laser settings for each stage were determined by aberrometry measurements. Eyes with desired monovision (undercorrected) outcome and preoperative hyperopia were excluded from the study. INTERVENTION: An aberrometry-guided laser treatment (InterWave LASIK) was compared with the standard LASIK treatment based upon the manifest refraction. MAIN OUTCOME MEASURES: Uncorrected visual acuity (VA), manifest refraction, best spectacle-corrected VA (BSCVA), severity of halos, and root mean square (RMS) retinal blur area measured at 3 months postoperatively. RESULTS: Three months postoperatively there was no difference in uncorrected VA, BSCVA, refraction, or RMS retinal blur areas for pupil sizes of 3.5 mm between eyes treated by InterWave and those treated by standard LASIK. However, InterWave LASIK reduced the retinal blur area by 48% (P<0.0103) and 58% (P<0.0004) in primary cases and 43% (P<0.0430) and 74% (P<0.0271) in enhancement cases, respectively, for pupil sizes of 4.5 and 6.5 mm relative to standard LASIK treatments. Patients undergoing InterWave-guided treatment reported less severity of halo (0.37 vs. 0.98 [P<0.016] for primary cases and 0.35 vs. 0.73 [P<0.04] for enhancement cases). CONCLUSION: InterWave LASIK achieved acuity and refractive results equivalent to those of standard LASIK treatment based upon refraction, but resulted in superior quality mesopic vision.


Assuntos
Córnea/fisiopatologia , Técnicas de Diagnóstico Oftalmológico , Ceratomileuse Assistida por Excimer Laser In Situ , Indicadores de Qualidade em Assistência à Saúde , Erros de Refração/fisiopatologia , Visão Ocular/fisiologia , Adulto , Idoso , Córnea/cirurgia , Humanos , Pessoa de Meia-Idade , Refração Ocular/fisiologia , Procedimentos Cirúrgicos Refrativos , Estudos Retrospectivos , Acuidade Visual/fisiologia
14.
Appl Opt ; 42(22): 4621-32, 2003 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-12916631

RESUMO

The effectiveness of image stabilization with a retinal tracker in a multifunction, compact scanning laser ophthalmoscope (TSLO) was demonstrated in initial human subject tests. The retinal tracking system uses a co confocal reflectometer with a closed-loop optical servo system to lock onto features in the fundus. The system is multifarious and modular to allow configuration for many research a clinical applications. Adult volunteers were tested without mydriasis to optimize the tracking instrumentation and to characterize imaging performance. The retinal tracking system achieves a bandwidth of greater than 1 kHz, which permits tracking at rates that greatly exceed the maximum rate of motion of the human eye. The TSLO system stabilized images to an accuracy of 0.05 deg in all test subjects during ordinary saccades with a velocity up to approximately 500 deg/s. Feature lock was maintained for minutes despite subject eye blinking. Even when nearly 1000 frames were coadded, image blur was minimal. Successful frame coaddition allowed image acquisition with decreased noise in low-light applications. The retinal tracking system significantly enhances the imaging capabilities of the scanning laser ophthalmoscope.


Assuntos
Processamento de Imagem Assistida por Computador , Lasers , Oftalmoscópios , Retina/fisiologia , Desenho de Equipamento , Humanos , Microscopia Confocal , Espalhamento de Radiação
15.
Appl Opt ; 42(4): 736-44, 2003 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-12564494

RESUMO

The spatially resolved refractometer is an aberrometer used to measure the wave-front aberrations of the human eye. In its original form and the new configuration that we report, it uses the patient's perception in a psychophysical task to evaluate the wave-front errors at a variable number of loci (typically 40 or 160) across the cornea. This configuration includes pupil tracking and the ability to choose the measurement loci in software. An automated configuration that does not require patient input is also described.


Assuntos
Fenômenos Fisiológicos Oculares , Psicofísica/instrumentação , Refração Ocular , Calibragem , Córnea/fisiologia , Humanos , Modelos Teóricos , Psicofísica/métodos , Reprodutibilidade dos Testes , Retina/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...