Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chem ; 91(24): 15411-15417, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31747247

RESUMO

Direct analyte-probed nanoextraction (DAPNe) is a technique that allows extraction of drug and endogenous compounds from a discrete location on a tissue sample using a nano capillary filled with solvent. Samples can be extracted from spot diameters as low as 6 µm. Studies previously undertaken by our group have shown that the technique can provide good precision (5%) for analyzing drug molecules in 150 µm diameter areas of homogenized tissue, provided an internal standard is sprayed on to the tissue prior to analysis. However, without an isotopically labeled standard, the repeatability is poor, even after normalization to the spot area or matrix compounds. By application to tissue homogenates spiked with drug compounds, we can demonstrate that it is possible to significantly improve the repeatability of the technique by incorporating a liquid chromatography separation step. Liquid chromatography is a technique for separating compounds prior to mass spectrometry (LC-MS) which enables separation of isomeric compounds that cannot be discriminated using mass spectrometry alone, as well as reducing matrix interferences. Conventionally, LC-MS is carried out on bulk or homogenized samples, which means analysis is essentially an average of the sample and does not take into account discrete areas. This work opens a new opportunity for spatially resolved liquid chromatography mass spectrometry with precision better than 20%.

2.
Anal Chem ; 90(20): 12094-12100, 2018 10 16.
Artigo em Inglês | MEDLINE | ID: mdl-30260213

RESUMO

Direct analyte probed nanoextraction (DAPNe) is a method of extracting material from a microscale region of a sample and provides the opportunity for detailed mass spectrometry analysis of extracted analytes from a small area. The technique has been shown to provide enhanced sensitivity compared with bulk analysis by selectively removing analytes from their matrix and has been applied for selective analysis of single cells and even single organelles. However, the quantitative capabilities of the technique are yet to be fully evaluated. In this study, various normalization techniques were investigated in order to improve the quantitative capabilities of the technique. Two methods of internal standard incorporation were applied to test substrates, which were designed to replicate biological sample matrices. Additionally, normalization to the extraction spot area and matrix compounds were investigated for suitability in situations when an internal standard is not available. The variability observed can be significantly reduced by using a sprayed internal standard and, in some cases, by normalizing to the extracted area.


Assuntos
Fígado/citologia , Nanotecnologia , Análise de Célula Única , Humanos , Espectrometria de Massas , Organelas/química
3.
Analyst ; 138(16): 4649-55, 2013 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-23775063

RESUMO

Imaging and analyzing gunshot residue (GSR) particles using the scanning electron microscope equipped with an energy dispersive X-ray spectrometer (SEM-EDS) is a standard technique that can provide important forensic evidence, but the discrimination power of this technique is limited due to low sensitivity to trace elements and difficulties in obtaining quantitative results from small particles. A new, faster method using a scanning proton microbeam and Particle Induced X-ray Emission (µ-PIXE), together with Elastic Backscattering Spectrometry (EBS) is presented for the non-destructive, quantitative analysis of the elemental composition of single GSR particles. In this study, the GSR particles were all Pb, Ba, Sb. The precision of the method is assessed. The grouping behaviour of different makes of ammunition is determined using multivariate analysis. The protocol correctly groups the cartridges studied here, with a confidence >99%, irrespective of the firearm or population of particles selected.


Assuntos
Armas de Fogo , Medicina Legal/métodos , Espectrometria por Raios X/métodos , Ferimentos por Arma de Fogo , Medicina Legal/normas , Humanos , Microscopia Eletrônica de Varredura/métodos , Microscopia Eletrônica de Varredura/normas , Espectrometria por Raios X/normas
4.
Forensic Sci Int ; 230(1-3): 81-6, 2013 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-23622791

RESUMO

The effect of vacuum exposure on latent fingerprint chemistry has been evaluated. Fingerprints were analysed using a quartz crystal microbalance to measure changes in mass, gas chromatography mass spectrometry to measure changes in lipid composition and attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) to determine changes in the content of water, fatty acids and their esters after exposure to vacuum. The results are compared with samples aged under ambient conditions. It was found that fingerprints lose around 26% of their mass when exposed to vacuum conditions, equivalent to around 5 weeks ageing under ambient conditions. Further exposure to vacuum causes a significant reduction in the lipid composition of a fingerprint, in particular with the loss of tetradecanoic and pentadecanoic acid, that was not observed in ambient aged samples. There are therefore implications for sequence in which fingerprint development procedures (for example vacuum metal deposition) are carried out, as well as the use of vacuum based methods such as secondary ion mass spectrometry (SIMS) and matrix-assisted laser desorption ionisation (MALDI) in the study of fingerprint chemistry.


Assuntos
Água Corporal , Dermatoglifia , Ácidos Graxos/análise , Vácuo , Ésteres , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Técnicas de Microbalança de Cristal de Quartzo , Espectroscopia de Infravermelho com Transformada de Fourier , Fatores de Tempo
5.
Anal Chem ; 84(20): 8514-23, 2012 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-22931387

RESUMO

The first analytical intercomparison of fingerprint residue using equivalent samples of latent fingerprint residue and characterized by a suite of relevant techniques is presented. This work has never been undertaken, presumably due to the perishable nature of fingerprint residue, the lack of fingerprint standards, and the intradonor variability, which impacts sample reproducibility. For the first time, time-of-flight secondary ion mass spectrometry, high-energy secondary ion mass spectrometry, and X-ray photoelectron spectroscopy are used to target endogenous compounds in fingerprints and a method is presented for establishing their relative abundance in fingerprint residue. Comparison of the newer techniques with the more established gas chromatography/mass spectrometry and attenuated total reflection Fourier transform infrared spectroscopic imaging shows good agreement between the methods, with each method detecting repeatable differences between the donors, with the exception of matrix-assisted laser desorption ionization, for which quantitative analysis has not yet been established. We further comment on the sensitivity, selectivity, and practicability of each of the methods for use in future police casework or academic research.


Assuntos
Dermatoglifia , Cromatografia Gasosa-Espectrometria de Massas , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Espectrometria de Massa de Íon Secundário , Espectroscopia de Infravermelho com Transformada de Fourier , Cromatografia Gasosa-Espectrometria de Massas/métodos , Humanos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Espectrometria de Massa de Íon Secundário/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
6.
Radiat Res ; 178(3): 182-90, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22823572

RESUMO

The Surrey vertical beam is a new facility for targeted irradiation of cells in medium with singly counted ions. A duo-plasmatron ion source and a 2 MV Tandem™ accelerator supply a range of ions from protons to calcium for this beamline and microscope endstation, with energy ranges from 0.5 to 12 MeV. A magnetic quadrupole triplet lens is used to focus the beam of ions. We present the design of this beamline, and early results showing the capability to count single ions with 98% certainty on CR-39 track etch. We also show that the beam targeting accuracy is within 5 µm and selectively target human fibroblasts with a <5 µm carbon beam, using γ-H2AX immunofluorescence to demonstrate which cell nuclei were irradiated. We discuss future commissioning steps necessary to achieve submicron targeting accuracy with this beamline.


Assuntos
Nanotecnologia/instrumentação , Aceleradores de Partículas/instrumentação , Radiobiologia/instrumentação , Animais , Linhagem Celular , Sobrevivência Celular/efeitos da radiação , Cricetinae , Cricetulus , Retroalimentação , Humanos , Umidade , Temperatura
7.
Anal Chem ; 84(9): 4083-7, 2012 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-22462501

RESUMO

A new protocol using time-of-flight secondary ion mass spectrometry (ToF-SIMS) has been developed to identify the deposition order of a fingerprint overlapping an ink line on paper. By taking line scans of fragment ions characteristic of the ink molecules (m/z 358.2 and 372.2) where the fingerprint and ink overlap and by calculating the normalized standard deviation of the intensity variation across the line scan, it is possible to determine whether or not a fingerprint is above ink on a paper substrate. The protocol adopted works for a selection of fingerprints from four donors tested here and for a fingerprint that was aged for six months; for one donor, the very faint fingerprints could not be visualized using either standard procedures (ninhydrin development) or SIMS, and therefore the protocol correctly gives an inconclusive result.


Assuntos
Dermatoglifia , Tinta , Espectrometria de Massa de Íon Secundário/métodos , Humanos , Papel , Sensibilidade e Especificidade
8.
Anal Chem ; 81(6): 2260-7, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19228010

RESUMO

The early stages of C(60) bombardment of octane and octatetraene crystals are modeled using molecular dynamics simulations with incident energies of 5-20 keV. Using the AIREBO potential, which allows for chemical reactions in hydrocarbon molecules, we are able to investigate how the projectile energy is partitioned into changes in potential and kinetic energy as well as how much energy flows into reacted molecules and internal energy. Several animations have been included to illustrate the bombardment process. The results show that the material near the edge of the crater can be ejected with low internal energies and that ejected molecules maintain their internal energies in the plume, in contrast to a collisional cooling mechanism previously proposed. In addition, a single C(60) bombardment was able to create many free and reacted H atoms which may aid in the ionization of molecules upon subsequent bombardment events.


Assuntos
Fulerenos/química , Íons/química , Simulação de Dinâmica Molecular , Octanos/química , Termodinâmica , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...