Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.070
Filtrar
2.
J Eur Acad Dermatol Venereol ; 38(1): 112-123, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37669776

RESUMO

BACKGROUND: While most cutaneous squamous cell carcinomas (cSCCs) are treatable, certain high-risk cSCCs, such as those in recessive dystrophic epidermolysis bullosa (RDEB) patients, are particularly aggressive. Owing to repeated wounding, inflammation and unproductive healing, RDEB patients have a 68% cumulative risk of developing life-threatening cSCCs by the age of 35, and a 70% risk of death by the age of 45. Despite aggressive treatment, cSCC represents the leading cause of premature mortality in these patients, highlighting an unmet clinical need. Increasing evidence points to a role of altered metabolism in the initiation and maintenance of cSCC, making metabolism a potential therapeutic target. OBJECTIVES: We sought to determine the feasibility of targeting tumour cell energetics as a strategy to selectively hinder the growth advantage of aggressive cSCC. METHODS: We evaluated the cell energetics profiles of RDEB-SCC cells by analysing available gene expression data against multiple gene signatures and single-gene targets linked to metabolic reprogramming. Additionally, we employed real-time metabolic profiling to measure glycolysis and respiration in these cells. Furthermore, we investigated the anti-neoplastic properties of the metformin against human and murine high-risk cSCCs in vitro and in vivo. RESULTS: Gene expression analyses highlighted a divergence in cell energetics profiles between RDEB-SCC and non-malignant RDEB keratinocytes, with tumour cells demonstrating enhanced respiration and glycolysis scores. Real-time metabolic profiling supported these data and additionally highlighted a metabolic plasticity of RDEB-SCC cells. Against this background, metformin exerted an anti-neoplastic potential by hampering both respiration and glycolysis, and by inhibiting proliferation in vitro. Metformin treatment in an analogous model of fast-growing murine cSCC resulted in delayed tumour onset and slower tumour growth, translating to a 29% increase in median overall survival. CONCLUSIONS: Our data indicate that metformin exerts anti-neoplastic properties in aggressive cSCCs that exhibit high-risk features by interfering with respiration and glycolytic processes.


Assuntos
Carcinoma de Células Escamosas , Epidermólise Bolhosa Distrófica , Epidermólise Bolhosa , Neoplasias Cutâneas , Humanos , Animais , Camundongos , Carcinoma de Células Escamosas/metabolismo , Neoplasias Cutâneas/genética , Fosforilação Oxidativa , Epidermólise Bolhosa/complicações , Epidermólise Bolhosa Distrófica/tratamento farmacológico , Epidermólise Bolhosa Distrófica/genética
3.
Radiother Oncol ; 190: 109953, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37839557

RESUMO

BACKGROUND AND PURPOSE: The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at an average dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by eFLASHvs. pFLASH has yet been performed and constitutes the aim of the present study. MATERIALS AND METHODS: The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥110 Gy/s eFLASH and pFLASH) dose rates. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed using previously validated dosimetric approaches and experimental murine models. RESULTS: The difference between the average absorbed dose measured at Gantry 1 with PSI reference dosimeters and with CHUV/IRA dosimeters was -1.9 % (0.1 Gy/s) and + 2.5 % (110 Gy/s). The neurocognitive capacity of eFLASH and pFLASH irradiated mice was indistinguishable from the control, while both eCONV and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained after an ablative dose of 20 Gy delivered with the two beams at CONV and FLASH dose rates. Tumor rejection upon rechallenge indicates that anti-tumor immunity was activated independently of the beam-type and the dose-rate. CONCLUSION: Despite major differences in the temporal microstructure of proton and electron beams, this study shows that dosimetric standards can be established. Normal brain protection and tumor control were produced by the two beams. More specifically, normal brain protection was achieved when a single dose of 10 Gy was delivered in 90 ms or less, suggesting that the most important physical parameter driving the FLASH sparing effect might be the mean dose rate. In addition, a systemic anti-tumor immunological memory response was observed in mice exposed to high ablative dose of electron and proton delivered at CONV and FLASH dose rate.


Assuntos
Produtos Biológicos , Neoplasias , Terapia com Prótons , Humanos , Animais , Camundongos , Prótons , Elétrons , Dosagem Radioterapêutica , Radiometria
5.
Phys Med Biol ; 68(24)2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-37820691

RESUMO

Objective.Online adaptive radiotherapy aims to fully leverage the advantages of highly conformal therapy by reducing anatomical and set-up uncertainty, thereby alleviating the need for robust treatments. This requires extensive automation, among which is the use of deformable image registration (DIR) for contour propagation and dose accumulation. However, inconsistencies in DIR solutions between different algorithms have caused distrust, hampering its direct clinical use. This work aims to enable the clinical use of DIR by developing deep learning methods to predict DIR uncertainty and propagating it into clinically usable metrics.Approach.Supervised and unsupervised neural networks were trained to predict the Gaussian uncertainty of a given deformable vector field (DVF). Since both methods rely on different assumptions, their predictions differ and were further merged into a combined model. The resulting normally distributed DVFs can be directly sampled to propagate the uncertainty into contour and accumulated dose uncertainty.Main results.The unsupervised and combined models can accurately predict the uncertainty in the manually annotated landmarks on the DIRLAB dataset. Furthermore, for 5 patients with lung cancer, the propagation of the predicted DVF uncertainty into contour uncertainty yielded for both methods anexpected calibration errorof less than 3%. Additionally, theprobabilisticly accumulated dose volume histograms(DVH) encompass well the accumulated proton therapy doses using 5 different DIR algorithms. It was additionally shown that the unsupervised model can be used for different DIR algorithms without the need for retraining.Significance.Our work presents first-of-a-kind deep learning methods to predict the uncertainty of the DIR process. The methods are fast, yield high-quality uncertainty estimates and are useable for different algorithms and applications. This allows clinics to use DIR uncertainty in their workflows without the need to change their DIR implementation.


Assuntos
Aprendizado Profundo , Humanos , Incerteza , Redes Neurais de Computação , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos
6.
Sci Rep ; 13(1): 14809, 2023 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-37684299

RESUMO

The aim of this randomized clinical trial was to evaluate the impact of all-trans retinoic acid (ATRA) in combination with non-intensive chemotherapy in older unfit patients (> 60 years) with newly diagnosed NPM1-mutated acute myeloid leukemia. Patients were randomized (1:1) to low-dose chemotherapy with or without open-label ATRA 45 mg/m2, days 8-28; the dose of ATRA was reduced to 45 mg/m2, days 8-10 and 15 mg/m2, days 11-28 after 75 patients due to toxicity. Up to 6 cycles of cytarabine 20 mg/day s.c., bid, days 1-7 and etoposide 100 mg/day, p.o. or i.v., days 1-3 with (ATRA) or without ATRA (CONTROL) were intended. The primary endpoint was overall survival (OS). Between May 2011 and September 2016, 144 patients (median age, 77 years; range, 64-92 years) were randomized (72, CONTROL; 72, ATRA). Baseline characteristics were balanced between the two study arms. The median number of treatment cycles was 2 in ATRA and 2.5 in CONTROL. OS was significantly shorter in the ATRA compared to the CONTROL arm (p = 0.023; median OS: 5 months versus 9.2 months, 2-years OS rate: 7% versus 10%, respectively). Rates of CR/CRi were not different between treatment arms; infections were more common in ATRA beyond treatment cycle one. The addition of ATRA to low-dose cytarabine plus etoposide in an older, unfit patient population was not beneficial, but rather led to an inferior outcome.The clinical trial is registered at clinicaltrialsregister.eu (EudraCT Number: 2010-023409-37, first posted 14/12/2010).


Assuntos
Leucemia Mieloide Aguda , Humanos , Idoso , Etoposídeo/efeitos adversos , Leucemia Mieloide Aguda/tratamento farmacológico , Leucemia Mieloide Aguda/genética , Citarabina/efeitos adversos , Tretinoína/uso terapêutico , Proteínas Nucleares
7.
Phys Med Biol ; 68(17)2023 08 11.
Artigo em Inglês | MEDLINE | ID: mdl-37385266

RESUMO

Objective.Anatomical and daily set-up uncertainties impede high precision delivery of proton therapy. With online adaptation, the daily plan is reoptimized on an image taken shortly before the treatment, reducing these uncertainties and, hence, allowing a more accurate delivery. This reoptimization requires target and organs-at-risk (OAR) contours on the daily image, which need to be delineated automatically since manual contouring is too slow. Whereas multiple methods for autocontouring exist, none of them are fully accurate, which affects the daily dose. This work aims to quantify the magnitude of this dosimetric effect for four contouring techniques.Approach.Plans reoptimized on automatic contours are compared with plans reoptimized on manual contours. The methods include rigid and deformable registration (DIR), deep-learning based segmentation and patient-specific segmentation.Main results.It was found that independently of the contouring method, the dosimetric influence of usingautomaticOARcontoursis small (<5% prescribed dose in most cases), with DIR yielding the best results. Contrarily, the dosimetric effect of using theautomatic target contourwas larger (>5% prescribed dose in most cases), indicating that manual verification of that contour remains necessary. However, when compared to non-adaptive therapy, the dose differences caused by automatically contouring the target were small and target coverage was improved, especially for DIR.Significance.The results show that manual adjustment of OARs is rarely necessary and that several autocontouring techniques are directly usable. Contrarily, manual adjustment of the target is important. This allows prioritizing tasks during time-critical online adaptive proton therapy and therefore supports its further clinical implementation.


Assuntos
Terapia com Prótons , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Radiometria , Órgãos em Risco
8.
Phys Med Biol ; 68(11)2023 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-37172608

RESUMO

Objective.4D dose reconstruction in proton therapy with pencil beam scanning (PBS) typically relies on a single pre-treatment 4DCT (p4DCT). However, breathing motion during the fractionated treatment can vary considerably in both amplitude and frequency. We present a novel 4D dose reconstruction method combining delivery log files with patient-specific motion models, to account for the dosimetric effect of intra- and inter-fractional breathing variability.Approach.Correlation between an external breathing surrogate and anatomical deformations of the p4DCT is established using principal component analysis. Using motion trajectories of a surface marker acquired during the dose delivery by an optical tracking system, deformable motion fields are retrospectively reconstructed and used to generate time-resolved synthetic 4DCTs ('5DCTs') by warping a reference CT. For three abdominal/thoracic patients, treated with respiratory gating and rescanning, example fraction doses were reconstructed using the resulting 5DCTs and delivery log files. The motion model was validated beforehand using leave-one-out cross-validation (LOOCV) with subsequent 4D dose evaluations. Moreover, besides fractional motion, fractional anatomical changes were incorporated as proof of concept.Main results.For motion model validation, the comparison of 4D dose distributions for the original 4DCT and predicted LOOCV resulted in 3%/3 mm gamma pass rates above 96.2%. Prospective gating simulations on the p4DCT can overestimate the target dose coverage V95%by up to 2.1% compared to 4D dose reconstruction based on observed surrogate trajectories. Nevertheless, for the studied clinical cases treated with respiratory-gating and rescanning, an acceptable target coverage was maintained with V95%remaining above 98.8% for all studied fractions. For these gated treatments, larger dosimetric differences occurred due to CT changes than due to breathing variations.Significance.To gain a better estimate of the delivered dose, a retrospective 4D dose reconstruction workflow based on motion data acquired during PBS proton treatments was implemented and validated, thus considering both intra- and inter-fractional motion and anatomy changes.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Humanos , Terapia com Prótons/métodos , Estudos Retrospectivos , Estudos Prospectivos , Tomografia Computadorizada Quadridimensional/métodos , Movimento (Física) , Carmustina , Planejamento da Radioterapia Assistida por Computador/métodos
9.
bioRxiv ; 2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37131769

RESUMO

Background and purpose: The FLASH effect has been validated in different preclinical experiments with electrons (eFLASH) and protons (pFLASH) operating at a mean dose rate above 40 Gy/s. However, no systematic intercomparison of the FLASH effect produced by e vs. pFLASH has yet been performed and constitutes the aim of the present study. Materials and methods: The electron eRT6/Oriatron/CHUV/5.5 MeV and proton Gantry1/PSI/170 MeV were used to deliver conventional (0.1 Gy/s eCONV and pCONV) and FLASH (≥100 Gy/s eFLASH and pFLASH) irradiation. Protons were delivered in transmission. Dosimetric and biologic intercomparisons were performed with previously validated models. Results: Doses measured at Gantry1 were in agreement (± 2.5%) with reference dosimeters calibrated at CHUV/IRA. The neurocognitive capacity of e and pFLASH irradiated mice was indistinguishable from the control while both e and pCONV irradiated cohorts showed cognitive decrements. Complete tumor response was obtained with the two beams and was similar between e and pFLASH vs. e and pCONV. Tumor rejection was similar indicating that T-cell memory response is beam-type and dose-rate independent. Conclusion: Despite major differences in the temporal microstructure, this study shows that dosimetric standards can be established. The sparing of brain function and tumor control produced by the two beams were similar, suggesting that the most important physical parameter driving the FLASH effect is the overall time of exposure which should be in the range of hundreds of milliseconds for WBI in mice. In addition, we observed that immunological memory response is similar between electron and proton beams and is independent off the dose rate.

10.
Phys Med Biol ; 68(9)2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-37019120

RESUMO

Objective.fast and accurate contouring of daily 3D images is a prerequisite for online adaptive radiotherapy. Current automatic techniques rely either on contour propagation with registration or deep learning (DL) based segmentation with convolutional neural networks (CNNs). Registration lacks general knowledge about the appearance of organs and traditional methods are slow. CNNs lack patient-specific details and do not leverage the known contours on the planning computed tomography (CT). This works aims to incorporate patient-specific information into CNNs to improve their segmentation accuracy.Approach.patient-specific information is incorporated into CNNs by retraining them solely on the planning CT. The resulting patient-specific CNNs are compared to general CNNs and rigid and deformable registration for contouring of organs-at-risk and target volumes in the thorax and head-and-neck regions.Results.patient-specific fine-tuning of CNNs significantly improves contour accuracy compared to standard CNNs. The method further outperforms rigid registration and a commercial DL segmentation software and yields similar contour quality as deformable registration (DIR). It is additionally 7-10 times faster than DIR.Significance.patient-specific CNNs are a fast and accurate contouring technique, enhancing the benefits of adaptive radiotherapy.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias de Cabeça e Pescoço , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Planejamento da Radioterapia Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Redes Neurais de Computação
11.
Phys Med Biol ; 68(10)2023 05 11.
Artigo em Inglês | MEDLINE | ID: mdl-37084737

RESUMO

Background.At the Center for Proton Therapy at the Paul Scherrer Institute (PSI) the delivery of proton radiation is controlled via gas-based ionization chambers: the beam is turned off when a certain amount of preset charge has been collected. At low dose rates the charge collection efficiency in these detectors is unity, at ultra-high dose rates it is less due to induced charge recombination effects. If not corrected, the latter would lead to an overdosage.Purpose.In the scope of this work, we developed a novel approach to anin situcharge recombination correction for our dose defining detectors, when irradiated with a proton beam at ultra-high dose rates. This approach is based on the Two-Voltage-Method.Methods.We have translated this method to two separate devices operated simultaneously at different conditions. By doing so, the charge collection losses can be corrected directly and without the need for empirical correction values. This approach has been tested at ultra-high dose rates; proton beam was delivered by the COMET cyclotron to Gantry 1 at PSI.Results.We were able to correct the charge losses caused by recombination effects at local beam currents of approximately 700 nA (i.e. instantaneous dose rate of 3600 Gy s-1at isocenter). The corrected collected charges in our gaseous detectors were compared against recombination-free measurements with a Faraday cup. The ratio of both quantities shows no significant dose rate dependence within their respective combined uncertainties.Conclusions. Correcting recombination effects in our gas-based detectors with the novel method greatly eases the handling of Gantry 1 as 'FLASH test bench'. Not only is the application of a preset dose more accurate compared to using an empirical correction curve, also the re-determination of empirical correction curves in the case of a beam phase space change can be omitted.


Assuntos
Terapia com Prótons , Prótons , Radiometria/métodos , Terapia com Prótons/métodos , Ciclotrons , Radiação Ionizante
12.
Clin Lymphoma Myeloma Leuk ; 23(4): 279-290, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36797154

RESUMO

BACKGROUND: Hyperfractionated cyclophosphamide and dexamethasone (HyperCd) alone, or with carfilzomib(K) and/or daratumumab(D), represents a potential treatment option when rapid disease control is needed for patients with aggressive presentations of relapsed/refractory multiple myeloma (RRMM). PATIENTS AND METHODS: This is a single-center, retrospective analysis of adult patients with RRMM who received HyperCd with or without K and/or D between May 1, 2016 and August 1, 2019 at the University of Texas MD Anderson Cancer Center. We here report treatment response and safety outcomes. RESULTS: Data from 97 patients, 12 with plasma cell leukemia (PCL), were reviewed in this analysis. Patients had had a median of 5 prior lines of therapy and received a median of 1 consecutive cycle of hyperCd-based therapy. The overall response rate (ORR) of all patients was 71.8% (HyperCd 75%, HyperCdK 64.3%, D-HyperCd 73.3%, and D-HyperCdK 76.9%). Median progression-free survival and overall survival among all patients was 4.3 months (HyperCd 3.1 months, HyperCdK 4.5 months, D-HyperCd 3.3 months, and D-HyperCdK 6 months) and 9.0 months (HyperCd 7.4 months, HyperCdK 9.0 months, D-HyperCd 7.5 months, and D-HyperCdK 15.2 months), respectively. Grade 3/4 hematologic toxicities were common, thrombocytopenia being the most frequent at 76%. Notably, 29-41% of patients per treatment group had existing grade 3/4 cytopenias at initiation of hyperCd-based therapy. CONCLUSION: HyperCd-based regimens provided rapid disease control among MM patients, even when heavily pre-treated and with few remaining treatment options. Grade 3/4 hematologic toxicities were frequent, but manageable with aggressive supportive care.


Assuntos
Mieloma Múltiplo , Trombocitopenia , Adulto , Humanos , Estudos Retrospectivos , Ciclofosfamida/efeitos adversos , Dexametasona/uso terapêutico , Trombocitopenia/induzido quimicamente , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
13.
Phys Med Biol ; 68(1)2022 12 26.
Artigo em Inglês | MEDLINE | ID: mdl-36571234

RESUMO

Objective.4D dose calculation (4DDC) for pencil beam scanned (PBS) proton therapy is typically based on phase-sorting of individual pencil beams onto phases of a single breathing cycle 4DCT. Understanding the dosimetric limitations and uncertainties of this approach is essential, especially for the realistic treatment scenario with irregular free breathing motion.Approach.For three liver and three lung cancer patient CTs, the deformable multi-cycle motion from 4DMRIs was used to generate six synthetic 4DCT(MRI)s, providing irregular motion (11/15 cycles for liver/lung; tumor amplitudes ∼4-18 mm). 4DDCs for two-field plans were performed, with the temporal resolution of the pencil beam delivery (4-200 ms) or with 8 phases per breathing cycle (500-1000 ms). For the phase-sorting approach, the tumor center motion was used to determine the phase assignment of each spot. The dose was calculated either using the full free breathing motion or individually repeating each single cycle. Additionally, the use of an irregular surrogate signal prior to 4DDC on a repeated cycle was simulated. The CTV volume with absolute dose differences >5% (Vdosediff>5%) and differences in CTVV95%andD5%-D95%compared to the free breathing scenario were evaluated.Main results.Compared to 4DDC considering the full free breathing motion with finer spot-wise temporal resolution, 4DDC based on a repeated single 4DCT resulted inVdosediff>5%of on average 34%, which resulted in an overestimation ofV95%up to 24%. However, surrogate based phase-sorting prior to 4DDC on a single cycle 4DCT, reduced the averageVdosediff>5%to 16% (overestimationV95%up to 19%). The 4DDC results were greatly influenced by the choice of reference cycle (Vdosediff>5%up to 55%) and differences due to temporal resolution were much smaller (Vdosediff>5%up to 10%).Significance.It is important to properly consider motion irregularity in 4D dosimetric evaluations of PBS proton treatments, as 4DDC based on a single 4DCT can lead to an underestimation of motion effects.


Assuntos
Neoplasias Pulmonares , Terapia com Prótons , Humanos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Quadridimensional/métodos , Movimento (Física) , Terapia com Prótons/métodos , Respiração , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia
14.
Phys Med ; 104: 101-111, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36395638

RESUMO

PURPOSE: To characterize an experimental setup for ultra-high dose rate (UHDR) proton irradiations, and to address the challenges of dosimetry in millimetre-small pencil proton beams. METHODS: At the PSI Gantry 1, high-energy transmission pencil beams can be delivered to biological samples and detectors up to a maximum local dose rate of âˆ¼9000 Gy/s. In the presented setup, a Faraday cup is used to measure the delivered number of protons up to ultra-high dose rates. The response of transmission ion-chambers, as well as of different field detectors, was characterized over a wide range of dose rates using the Faraday cup as reference. RESULTS: The reproducibility of the delivered proton charge was better than 1 % in the proposed experimental setup. EBT3 films, Al2O3:C optically stimulated luminescence detectors and a PTW microDiamond were used to validate the predicted dose. Transmission ionization chambers showed significant volume ion-recombination (>30 % in the tested conditions) which can be parametrized as a function of the maximum proton current density. Over the considered range, EBT3 films, inorganic scintillator-based screens and the PTW microDiamond were demonstrated to be dose rate independent within ±3 %, ±1.8 % and ±1 %, respectively. CONCLUSIONS: Faraday cups are versatile dosimetry instruments that can be used for dose estimation, field detector characterization and on-line dose verification for pre-clinical experiments in UHDR proton pencil beams. Among the tested detectors, the commercial PTW microDiamond was found to be a suitable option to measure real time the dosimetric properties of narrow pencil proton beams for dose rates up to 2.2 kGy/s.


Assuntos
Prótons , Reprodutibilidade dos Testes
15.
J Nutr Health Aging ; 26(4): 346-351, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35450990

RESUMO

IMPORTANCE: Inflammaging is considered a driver of age-related loss of muscle mass and function (sarcopenia). As nutrition might play a role in this process, the Dietary Inflammatory Index® (DII) has been developed to quantify the inflammatory potential of an individual diet. OBJECTIVES: We aimed to examine associations between the DII, inflammation, oxidative stress and sarcopenia-related parameters in healthy old compared to young adults. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional study included data of 79 community-dwelling, healthy old adults (65-85 years) and 59 young adults (18-35 years) who participated in a randomized controlled trial from April to December 2019. MEASUREMENTS: The DII was computed with dietary data collected from 24-h recall interviews. Associations between the DII, inflammatory and oxidative stress markers as well as bioimpedance-derived body composition, handgrip strength and gait speed were determined with multiple linear regression analyses adjusted for age, sex, physical activity and insulin resistance. RESULTS: Regression analyses revealed significant relationships between a higher interleukin (IL) 6 and IL-6:IL-10-ratio and higher percentage fat mass (%FM), waist-to-height-ratio (WHtR) as well as lower percentage skeletal muscle mass (%SMM) and gait speed exclusively in old adults. Subsequent analyses showed that IL-6 was associated with a pro-inflammatory diet as indicated by a higher DII, again exclusively in old adults (beta coefficient (ß)= 0.027, standard error (SE) 0.013, p=0.037). While the DII was not related with handgrip strength or oxidative stress in neither old nor young adults, linear models confirmed that a higher DII was inversely associated with gait speed in old participants (ß= -0.022, SE 0.006, p<0.001). Finally, a pro-inflammatory diet was significantly associated with higher %FM, WHtR and lower %SMM in both age groups. CONCLUSION AND RELEVANCE: A pro-inflammatory diet reflected by the DII is associated with higher systemic inflammation, slower gait speed as well as lower muscle mass in old adults. Intervention studies are needed to examine whether anti-inflammatory dietary approaches can help to improve muscle mass and function and thus minimize the risk for sarcopenia in the long-term.


Assuntos
Sarcopenia , Índice de Massa Corporal , Estudos Transversais , Dieta , Força da Mão , Humanos , Inflamação , Interleucina-6 , Músculo Esquelético/fisiologia , Sarcopenia/etiologia
16.
Neth Heart J ; 30(10): 481-485, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35352274

RESUMO

BACKGROUND: Data on the impact of the cumulative percutaneous left atrial appendage closure (LAAC) caseload on cardiovascular outpatient and hospitalisation costs are limited. METHODS: The present single-institution analysis includes patients treated consecutively from the beginning of our LAAC experience in January 2012 until December 2016. Pre- and post-LAAC costs for hospitalisation and ambulatory visits were included. RESULTS: A total of 676 patients underwent percutaneous LAAC (using the Watchman device): 49 (2012), 78 (2013), 211 (2014), 210 (2015), and 129 (2016). LAAC procedural costs were stable over the years (overall median €9639; 2012: €9630; 2013: €10,003; 2014: €9841; 2015: €9394; 2016: €9530; p = 0.8) and there was no correlation between cumulative caseload and procedural costs (p = 0.9). Although annualised cardiovascular management costs after LAAC were lower than before LAAC (median difference between pre-LAAC and post-LAAC yearly costs: €727; 2012: €235; 2013: €1187; 2014: €716; 2015: €527; 2016: €1052; p = 0.5 among years analysed) from the beginning of the cumulative procedural experience, a significant reduction in costs was observed only from 2014 onwards. Institutional cumulative LAAC caseload and year of procedure were not related to the amount of reduction in the costs for cardiovascular care. CONCLUSION: LAAC led to cost-of-care savings from the beginning of our institutional procedural experience.

17.
Clin Oncol (R Coll Radiol) ; 33(12): e578-e585, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34340918

RESUMO

AIMS: Sacral chordomas are locally aggressive, radio-resistant tumours. Proton therapy has the potential to deliver high radiation doses, which may improve the therapeutic ratio when compared with conventional radiotherapy. We assessed tumour control and radiation-induced toxicity in a cohort of sacral chordoma patients treated with definitive or postoperative pencil beam scanning proton therapy. METHODS AND MATERIALS: Sixty patients with histologically proven sacral chordoma treated between November 1997 and October 2018 at the Paul Scherrer Institute with postoperative (n = 50) or definitive proton therapy (n = 10) were retrospectively analysed. Only 10 (17%) patients received combined photon radiotherapy and proton therapy. Survival rates were calculated using the Kaplan-Meier actuarial method. The Log-rank test was used to compare different functions for local control, freedom from distant recurrence and overall survival. Acute and late toxicity were assessed according to the Common Terminology Criteria for Adverse Events (CTCAE) v5.0. RESULTS: The median follow-up was 48 months (range 4-186). Local recurrence occurred in 20 (33%) patients. The 4-year local control, freedom from distant recurrence and overall survival rates were 77%, 89% and 85%, respectively. On univariate analysis, subtotal resection/biopsy (P = 0.02), tumour extension restricted to bone (P = 0.01) and gross tumour volume >130 ml (P = 0.04) were significant predictors for local recurrence. On multivariate analysis, tumour extension restricted to bone (P = 0.004) and gross total resection (P = 0.02) remained independent favourable prognostic factors for local recurrence. Twenty-four (40%), 28 (47%) and eight (11%) patients experienced acute grade 1, 2 and 3 toxicities, respectively. The 4-year late toxicity-free survival was 91%. Two patients developed secondary malignancies to the bladder 3-7 years after proton therapy. CONCLUSIONS: Our data indicate that pencil beam scanning proton therapy for sacral chordomas is both safe and effective. Gross total resection, tumour volume <130 ml and tumour restricted to the bone are favourable prognostic factors for local tumour control.


Assuntos
Cordoma , Terapia com Prótons , Neoplasias da Coluna Vertebral , Cordoma/radioterapia , Humanos , Recidiva Local de Neoplasia/radioterapia , Terapia com Prótons/efeitos adversos , Estudos Retrospectivos , Neoplasias da Coluna Vertebral/radioterapia , Carga Tumoral
18.
Nat Commun ; 12(1): 4512, 2021 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-34301938

RESUMO

α-RuCl3 is a major candidate for the realization of the Kitaev quantum spin liquid, but its zigzag antiferromagnetic order at low temperatures indicates deviations from the Kitaev model. We have quantified the spin Hamiltonian of α-RuCl3 by a resonant inelastic x-ray scattering study at the Ru L3 absorption edge. In the paramagnetic state, the quasi-elastic intensity of magnetic excitations has a broad maximum around the zone center without any local maxima at the zigzag magnetic Bragg wavevectors. This finding implies that the zigzag order is fragile and readily destabilized by competing ferromagnetic correlations. The classical ground state of the experimentally determined Hamiltonian is actually ferromagnetic. The zigzag state is stabilized by quantum fluctuations, leaving ferromagnetism - along with the Kitaev spin liquid - as energetically proximate metastable states. The three closely competing states and their collective excitations hold the key to the theoretical understanding of the unusual properties of α-RuCl3 in magnetic fields.

19.
ESMO Open ; 6(3): 100161, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34090172

RESUMO

BACKGROUND: The improved efficacy of tyrosine kinase inhibitors (TKI) mandates reappraisal of local therapy (LT) for brain metastases (BM) of oncogene-driven non-small-cell lung cancer (NSCLC). PATIENTS AND METHODS: This study included all epidermal growth factor receptor-mutated (EGFR+, n = 108) and anaplastic lymphoma kinase-rearranged (ALK+, n = 33) TKI-naive NSCLC patients diagnosed with BM in the Thoraxklinik Heidelberg between 2009 and 2019. Eighty-seven patients (62%) received early LT, while 54 (38%) received delayed (n = 34; 24%) or no LT (n = 20; 14%). LT comprised stereotactic (SRT; n = 40; 34%) or whole-brain radiotherapy (WBRT; n = 77; 66%), while neurosurgical resection was carried out in 19 cases. RESULTS: Median overall survival (OS) was 49.1 months for ALK+ and 19.5 months for EGFR+ patients (P = 0.001), with similar median intracranial progression-free survival (icPFS) (15.7 versus 14.0 months, respectively; P = 0.80). Despite the larger and more symptomatic BM (P < 0.001) of patients undergoing early LT, these experienced longer icPFS [hazard ratio (HR) 0.52; P = 0.024], but not OS (HR 1.63; P = 0.12), regardless of the radiotherapy technique (SRT versus WBRT) and number of lesions. High-risk oncogene variants, i.e. non-del19 EGFR mutations and 'short' EML4-ALK fusions (mainly variant 3, E6:A20), were associated with earlier intracranial progression (HR 2.97; P = 0.001). The longer icPFS with early LT was also evident in separate analyses of the EGFR+ and ALK+ subsets. CONCLUSIONS: Despite preferential use for cases with poor prognostic factors, early LT prolongs the icPFS, but not OS, in TKI-treated EGFR+/ALK+ NSCLC. Considering the lack of survival benefit, and the neurocognitive effects of WBRT, patients presenting with polytopic BM may benefit from delaying radiotherapy, or from radiosurgery of multiple or selected lesions. For SRT candidates, the improved tumor control with earlier radiotherapy should be weighed against the potential toxicity and the enhanced intracranial activity of newer TKI. High-risk EGFR/ALK variants are associated with earlier intracranial failure and identify patients who could benefit from more aggressive management.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radiocirurgia , Encéfalo , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Oncogenes/genética
20.
Radiat Oncol ; 16(1): 81, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33933118

RESUMO

INTRODUCTION: The current phase III EORTC 1420 Best-of trial (NCT02984410) compares the swallowing function after transoral surgery versus intensity modulated radiotherapy (RT) in patients with early-stage carcinoma of the oropharynx, supraglottis and hypopharynx. We report the analysis of the Benchmark Case (BC) procedures before patient recruitment with special attention to dysphagia/aspiration related structures (DARS). MATERIALS AND METHODS: Submitted RT volumes and plans from participating centers were analyzed and compared against the gold-standard expert delineations and dose distributions. Descriptive analysis of protocol deviations was conducted. Mean Sorensen-Dice similarity index (mDSI) and Hausdorff distance (mHD) were applied to evaluate the inter-observer variability (IOV). RESULTS: 65% (23/35) of the institutions needed more than one submission to achieve Quality assurance (RTQA) clearance. OAR volume delineations were the cause for rejection in 53% (40/76) of cases. IOV could be improved in 5 out of 12 OARs by more than 10 mm after resubmission (mHD). Despite this, final IOV for critical OARs in delineation remained significant among DARS by choosing an aleatory threshold of 0.7 (mDSI) and 15 mm (mHD). CONCLUSIONS: This is to our knowledge the largest BC analysis among Head and neck RTQA programs performed in the framework of a prospective trial. Benchmarking identified non-common OARs and target delineations errors as the main source of deviations and IOV could be reduced in a significant number of cases after this process. Due to the substantial resources involved with benchmarking, future benchmark analyses should assess fully the impact on patients' clinical outcome.


Assuntos
Benchmarking/métodos , Neoplasias Hipofaríngeas/radioterapia , Órgãos em Risco/efeitos da radiação , Neoplasias Orofaríngeas/radioterapia , Garantia da Qualidade dos Cuidados de Saúde/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Supraglotite/radioterapia , Ensaios Clínicos Fase III como Assunto , Humanos , Neoplasias Hipofaríngeas/patologia , Variações Dependentes do Observador , Neoplasias Orofaríngeas/patologia , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Supraglotite/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...