Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
IEEE Trans Biomed Eng ; 65(10): 2248-2258, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29993470

RESUMO

OBJECTIVE: Novel minimum-contact vital signs monitoring techniques like textile or capacitive electrocardiogram (ECG) provide new opportunities for health monitoring. These techniques are sensitive to artifacts and require handling of unstable signal quality. Spatio-temporal blind source separation (BSS) is capable of processing suchlike multichannel signals. However, BSS's permutation indeterminacy requires the selection of the cardiac signal (i.e., the component resembling the electric cardiac activity) after its separation from artifacts. This study evaluates different concepts for solving permutation indeterminacy. METHODS: Novel automated component selection routines based on heartbeat detections are compared with standard concepts, as using higher order moments or frequency-domain features, for solving permutation indeterminacy in spatio-temporal BSS. BSS was applied to a textile and a capacitive ECG dataset of healthy subjects performing a motion protocol, and to the MIT-BIH Arrhythmia Database. The performance of the subsequent component selection was evaluated by means of the heartbeat detection accuracy (ACC) using an automatically selected single component. RESULTS: The proposed heartbeat-detection-based selection routines significantly outperformed the standard selectors based on Skewness, Kurtosis, and frequency-domain features, especially for datasets containing motion artifacts. For arrhythmia data, beat analysis by sparse coding outperformed simple periodicity tests of the detected heartbeats. CONCLUSION: Component selection routines based on heartbeat detections are capable of reliably selecting cardiac signals after spatio-temporal BSS in case of severe motion artifacts and arrhythmia. SIGNIFICANCE: The availability of robust cardiac component selectors for solving permutation indeterminacy facilitates the usage of spatio-temporal BSS to extract cardiac signals in artifact-sensitive minimum-contact vital signs monitoring techniques.


Assuntos
Eletrocardiografia/métodos , Coração/fisiologia , Processamento de Sinais Assistido por Computador , Algoritmos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Bases de Dados Factuais , Humanos
2.
Biomed Tech (Berl) ; 63(5): 617-634, 2018 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-29897880

RESUMO

Over the last few years, the contactless acquisition of cardiovascular parameters using cameras has gained immense attention. The technique provides an optical means to acquire cardiovascular information in a very convenient way. This review provides an overview on the technique's background and current realizations. Besides giving detailed information on the most widespread application of the technique, namely the contactless acquisition of heart rate, we outline further concepts and we critically discuss the current state.


Assuntos
Diagnóstico por Imagem/métodos , Frequência Cardíaca/fisiologia , Fotopletismografia/instrumentação , Humanos , Fotopletismografia/métodos
3.
Biomed Eng Online ; 17(1): 33, 2018 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-29540189

RESUMO

BACKGROUND: Camera-based photoplethysmography (cbPPG) is a measurement technique which enables remote vital sign monitoring by using cameras. To obtain valid plethysmograms, proper regions of interest (ROIs) have to be selected in the video data. Most automated selection methods rely on specific spatial or temporal features limiting a broader application. In this work, we present a new method which overcomes those drawbacks and, therefore, allows cbPPG to be applied in an intraoperative environment. METHODS: We recorded 41 patients during surgery using an RGB and a near-infrared (NIR) camera. A Bayesian skin classifier was employed to detect suitable regions, and a level set segmentation approach to define and track ROIs based on spatial homogeneity. RESULTS: The results show stable and homogeneously illuminated ROIs. We further evaluated their quality with regards to extracted cbPPG signals. The green channel provided the best results where heart rates could be correctly estimated in 95.6% of cases. The NIR channel yielded the highest contribution in compensating false estimations. CONCLUSIONS: The proposed method proved that cbPPG is applicable in intraoperative environments. It can be easily transferred to other settings regardless of which body site is considered.


Assuntos
Dispositivos Ópticos , Fotopletismografia/instrumentação , Idoso , Feminino , Frequência Cardíaca , Humanos , Período Intraoperatório , Masculino , Razão Sinal-Ruído
4.
J Biomed Opt ; 22(3): 35002, 2017 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-28257535

RESUMO

Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-to-noise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR.


Assuntos
Determinação da Frequência Cardíaca/métodos , Frequência Cardíaca , Processamento de Sinais Assistido por Computador , Algoritmos , Determinação da Frequência Cardíaca/normas , Humanos , Análise de Componente Principal , Razão Sinal-Ruído , Gravação em Vídeo
5.
Physiol Meas ; 35(8): 1551-67, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25071095

RESUMO

The fetal ECG derived from abdominal leads provides an alternative to standard means of fetal monitoring. Furthermore, it permits long-term and ambulant recordings, which expands the range diagnostic possibilities for evaluating the fetal health state. However, due to the temporal and spectral overlap of maternal and fetal signals, the usage of abdominal leads imposes the need for elaborated signal processing routines.In this work a modular combination of processing techniques is presented. Its core consists of two maternal ECG estimation techniques, namely the extended Kalman smoother (EKS) and template adaption (TA) in combination with an innovative detection algorithm. Our detection method employs principles of evolutionary computing to detect fetal peaks by considering the periodicity and morphological characteristics of the fetal signal. In a postprocessing phase, single channel detections are combined by means of kernel density estimation and heart rate correction.The described methodology was presented during the Computing in Cardiology Challenge 2013. The entry was the winner of the closed-source events with average scores for events 4/5 with 15.1/3.32 (TA) and 69.5/4.58 (EKS) on training set-A and 20.4/4.57 (TA) and 219/7.69 (EKS) on test set-B, respectively. Using our own clinical data (24 subjects each 20 min recordings) and statistical measures beyond the Challenge's scoring system, we further validated the proposed method. For our clinical data we obtained an average detection rate of 82.8% (TA) and 83.4% (EKS). The achieved results show that the proposed methods are able produce reliable fetal heart rate estimates from a restricted number of abdominal leads.


Assuntos
Abdome , Eletrocardiografia/métodos , Monitorização Fetal/métodos , Feto/fisiologia , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Frequência Cardíaca Fetal , Humanos , Gravidez , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...