Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 84(8): 084705, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24007086

RESUMO

An electromagnetic exposure chamber was designed to safely deliver electromagnetic power in the range of microwaves between 0.8 and 4.2 GHz to a thin cylindrical materials. This instrumentation is unique because the diagnostics not only measure sample heating with a response time of 1.3 ms, but also energy transmitted and reflected. Energy absorption at different frequencies was quantified via electromagnetic heating using an infrared camera. This in situ IR imaging of the spatial distribution of temperature during microwave exposure coupled with sensors for determining transmitted and reflected energy enables novel new microwave energy experiments. Samples were exposed to a portion of both the electric and magnetic fields inside a waveguide and based on sample dimensions, the field strengths were assumed uniform across the sample. Three materials were examined: two were borosilicate, first coated with graphite paint and a second without the coating; and, the third was a compressed sample of flake graphite pressed to 69% of its bulk density. Results are in agreement with the theories of microwave heating and verify the functionality of this experimental design. This diagnostic will be important in future tests where a variety of different materials can be exposed to weak electromagnetic waves and their efficiency in coupling to the microwaves can be examined.

2.
Scanning ; 25(6): 297-9, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-14696978

RESUMO

The ability to detect small amounts of materials, especially bacterial organisms, is important for medical diagnostics and national security issues. Engineered micromechanical systems provide one approach for constructing multifunctional, highly sensitive, real-time, immunospecific biological detectors. We present qualitative detection of specific Salmonella enterica strains using a functionalized silicon nitride microcantilever. Detection is achieved due to a change in the surface stress on the cantilever surface in situ upon binding of a small number of bacteria. Scanning electron micrographs indicate that less than 25 adsorbed bacteria are required for detection.


Assuntos
Microscopia de Força Atômica/instrumentação , Microscopia de Força Atômica/métodos , Salmonella enterica/isolamento & purificação , Salmonella enterica/ultraestrutura , Anticorpos Antibacterianos , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Salmonella enterica/imunologia , Compostos de Silício
3.
Phys Rev Lett ; 88(25 Pt 1): 255505, 2002 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-12097097

RESUMO

We have investigated the effects of humidity, tip speed, and dwell time on feature size during dip pen nanolithography. Our results indicate a transition between two distinct deposition regimes occurs at a dwell time independent of humidity. While feature size increases with humidity, the relative increase is independent of dwell time. The results are described by a model that accounts for detachment and reattachment at the tip. The model suggests that, at short dwell times (high speed), the most important parameter controlling the feature size is the activation energy for thiol detachment.

4.
Ultramicroscopy ; 87(1-2): 19-23, 2001 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11310538

RESUMO

A novel application of coated silica tips for use in high-pressure, high-temperature, scanning tunneling microscopy is introduced. Thermal drift is reduced in the Z-direction due to the low thermal expansion of silica. Virtually, any conducting material that can be evaporated or sputtered can be used as a tip material. Experimental results are shown for tips sputter coated with platinum, along with images obtained.

SELEÇÃO DE REFERÊNCIAS