Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Immunol Methods ; 445: 37-44, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28274835

RESUMO

The immunogenicity risk assessment and bioanalytical strategy for novel therapeutics should account for both unique biophysical properties and potential consequences of immunogenicity. When assessing the immunogenicity risk of etelcalcetide, a peptide agonist of the calcium-sensing receptor, we considered the potential that the d-amino acid 'backbone' and biotransformation of etelcalcetide could allow the drug to act as a hapten. As a consequence, we validated and implemented a surface plasmon resonance immunoassay platform with both etelcalcetide and etelcalcetide-'carrier' surfaces to detect anti-drug antibodies (ADA). No evidence of in-vitro neutralizing activity with surrogate controls was detected despite multiple immunization approaches and a sensitive cell-based activity assay. Therefore, a neutralizing assay was not implemented for clinical support. We conducted an integrated analysis of immunogenicity data pooled from two pivotal placebo-controlled trials to define the clinical impact of anti-etelcalcetide antibodies. While both pre-existing and developing anti-etelcalcetide antibodies were detected, we show here that they have no consequences for clinical exposure, efficacy, or safety of etelcalcetide.


Assuntos
Imunoensaio , Peptídeos/imunologia , Ressonância de Plasmônio de Superfície , Animais , Anticorpos/imunologia , Humanos , Coelhos
2.
J Immunol Methods ; 396(1-2): 44-55, 2013 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-23933325

RESUMO

As with other protein therapeutics, trebananib (AMG 386), an investigational peptide Fc-fusion protein ("peptibody") that inhibits angiogenesis by neutralizing the interaction of angiopoietin-1 (Ang1) and angiopoietin-2 (Ang2) with the Tie2 receptor, has the potential to trigger an immune response in cancer patients treated with the therapeutic. An electrochemiluminescence bridging anti-drug antibody (ADA) assay that was utilized to support early-phase clinical trials in the development of trebananib was found to lack adequate sensitivity and drug tolerance in later-phase clinical studies when higher doses of trebananib were administered. Therefore, we developed a surface plasmon resonance (SPR) immunoassay method utilizing a secondary confirmatory detector antibody (goat anti-human IgG F[ab']2) known to cross-react with human IgG and IgM to better assess the potential impact of immunogenicity on the pharmacokinetics, pharmacodynamics, and toxicity of trebananib. The SPR method was more sensitive than the electrochemiluminescence bridging assay because of signal amplification from the confirmatory binding of the detector antibody; drug tolerance was improved since antibody binding avidity does not affect detection on this platform. Despite the inability of the confirmatory detector antibody to bind angiopoietins in protein-free buffer, false-positive ADA results were generated from patient serum samples containing Ang1 and Ang2 through an apparently specific binding between the angiopoietins and the confirmatory detector antibody, likely mediated by the interaction of the angiopoietins with serum immunoglobulins. Addition to the sample diluent of a human antibody that specifically binds to Ang1 and Ang2 with high affinity resulted in a complete block of angiopoietin interference without affecting ADA detection. This biosensor-based assay provides a reliable method for assessing immunogenicity in phase 3 clinical trials.


Assuntos
Inibidores da Angiogênese/análise , Técnicas Biossensoriais/métodos , Imunoensaio/métodos , Proteínas Recombinantes de Fusão/análise , Inibidores da Angiogênese/efeitos adversos , Inibidores da Angiogênese/farmacologia , Angiopoietina-1/metabolismo , Angiopoietina-2/metabolismo , Anticorpos Anti-Idiotípicos/sangue , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Luminescência , Neovascularização Patológica , Receptor TIE-2/metabolismo , Proteínas Recombinantes de Fusão/efeitos adversos , Proteínas Recombinantes de Fusão/farmacologia , Ressonância de Plasmônio de Superfície
3.
Clin Vaccine Immunol ; 20(1): 46-51, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23114696

RESUMO

Patients treated with erythropoietin-based erythropoiesis-stimulating agents (ESAs) can develop a rare but life-threatening condition called antibody-mediated pure red cell aplasia (amPRCA). The antibody characteristics in a nephrology patient with amPRCA include high antibody concentrations with neutralizing activity and a mixed IgG subclass including anti-ESA IgG4 antibodies. In contrast, anti-ESA IgG4 antibody is generally not detected in baseline samples and antibody-positive non-PRCA patients. Therefore, we validated a highly sensitive immunoassay on the ImmunoCAP 100 instrument to quantitate anti-ESA IgG4 antibodies using a human recombinant anti-epoetin alfa (EPO) IgG4 antibody as a calibrator. The biotinylated ESA was applied to a streptavidin ImmunoCAP, and bound anti-ESA IgG4 antibodies were detected using a ß-galactosidase-conjugated mouse anti-human IgG4 antibody. The validated assay was used to detect anti-ESA IgG4 in amPRCA and non-PRCA patients. The immunoassay detected 15 ng/ml of human anti-EPO IgG4 antibody in the presence of a 200 M excess of human anti-ESA IgG1, IgG2, or IgM antibody and tolerated 2 µg/ml of soluble erythropoietin. All patient samples with confirmed amPRCA had measurable anti-ESA IgG4 antibodies. In addition, 94% (17/18) of non-PRCA patient samples were antibody negative or had below 15 ng/ml of anti-ESA IgG4 antibodies. This novel immunoassay can measure low-nanogram quantities of human anti-ESA IgG4 antibodies in the presence of other anti-ESA antibodies. An increased concentration of anti-ESA IgG4 antibody is associated with the development of amPRCA. We propose that the measurement of anti-ESA specific IgG4 antibodies may facilitate early detection of amPRCA in patients receiving all ESAs structurally related to human erythropoietin.


Assuntos
Anticorpos Neutralizantes/sangue , Autoanticorpos/sangue , Técnicas de Laboratório Clínico/métodos , Eritropoetina/imunologia , Imunoglobulina G/sangue , Aplasia Pura de Série Vermelha/diagnóstico , Eritropoese/efeitos dos fármacos , Eritropoese/imunologia , Humanos , Imunoensaio/métodos , Sensibilidade e Especificidade
4.
BMC Clin Pharmacol ; 11: 17, 2011 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-22070868

RESUMO

BACKGROUND: Panitumumab is a fully human antibody against the epidermal growth factor receptor that is indicated for the treatment of metastatic colorectal cancer (mCRC) after disease progression on standard chemotherapy. The purpose of this analysis was to examine the immunogenicity of panitumumab and to evaluate the effect of anti-panitumumab antibodies on pharmacokinetic and safety profiles in patients with mCRC receiving panitumumab in combination with oxaliplatin- or irinotecan-based chemotherapies. METHODS: Three validated assays (two screening immunoassays and a neutralizing antibody bioassay) were used to detect the presence of anti-panitumumab antibodies in serum samples collected from patients enrolled in four panitumumab combination chemotherapy clinical trials. The impact of anti-panitumumab antibodies on pharmacokinetic and safety profiles was analyzed using population pharmacokinetic analysis and descriptive statistics, respectively. RESULTS: Of 1124 patients treated with panitumumab in combination with oxaliplatin- or irinotecan-based chemotherapy with postbaseline samples available for testing, 20 (1.8%) patients developed binding antibodies and 2 (0.2%) developed neutralizing antibodies. The incidence of anti-panitumumab antibodies was similar in patients with tumors expressing wild-type or mutant KRAS and in patients receiving oxaliplatin- or irinotecan-based chemotherapies. No evidence of an altered pharmacokinetic or safety profile was found in patients who tested positive for anti-panitumumab antibodies. CONCLUSIONS: The immunogenicity of panitumumab in the combination chemotherapy setting was infrequent and similar to the immunogenicity observed in the monotherapy setting. Panitumumab immunogenicity did not appear to alter pharmacokinetic or safety profiles. This low rate of immunogenicity may be attributed to the fully human nature of panitumumab.


Assuntos
Anticorpos Anti-Idiotípicos/análise , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais/efeitos adversos , Antineoplásicos/efeitos adversos , Hipersensibilidade a Drogas/imunologia , Anticorpos Monoclonais/sangue , Anticorpos Monoclonais/farmacocinética , Anticorpos Monoclonais/uso terapêutico , Anticorpos Monoclonais Humanizados/sangue , Anticorpos Monoclonais Humanizados/farmacocinética , Anticorpos Monoclonais Humanizados/uso terapêutico , Anticorpos Neutralizantes/análise , Antineoplásicos/sangue , Antineoplásicos/farmacocinética , Antineoplásicos/uso terapêutico , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Camptotecina/análogos & derivados , Camptotecina/uso terapêutico , Neoplasias Colorretais/complicações , Neoplasias Colorretais/tratamento farmacológico , Neoplasias Colorretais/imunologia , Hipersensibilidade a Drogas/sangue , Hipersensibilidade a Drogas/complicações , Hipersensibilidade a Drogas/epidemiologia , Humanos , Incidência , Irinotecano , Compostos Organoplatínicos/uso terapêutico , Oxaliplatina , Panitumumabe , Índice de Gravidade de Doença
5.
AAPS J ; 11(3): 526-34, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19626442

RESUMO

We designed a three-step statistical approach to transfer bioanalytical assays (ELISA and Biacore) which evaluates the (1) average equivalence between the two labs (2) concordance in individual sample results between the two labs, and (3) long-term stability of assay performance. Each experimental design evaluated the contribution of four critical variables to the overall variability. Two lots of each variable were examined in a controlled experiment. The variables tested for ELISA were analyst, plate washer, biotinylated-therapeutic protein, and streptavidin-horseradish peroxidase; and for Biacore were analyst, instrument, chip lot, and conjugation chemistry reagent lots. Equivalence in the mean signal to noise (S/N) or mean relative units (RU) between the two labs was established through statistical evaluation of the assay performance characteristics across multiple assay variables. Concordance between the two labs in the individual sample results was subsequently verified both quantitatively and qualitatively. The long-term maintenance of assay stability was monitored by performance testing of a predefined set of samples which were prepared in sufficient quantities to last several years. The process of method validation for biomarker testing in clinical trials is to analyze the variability of the assay performance. However, different factors contribute to this variability and need to be evaluated when the method is transferred to another site/lab. Lack of understanding the critical variables can potentially result in unexpected problems and delays. The three-step statistical approach of assay transfer provides a robust process for transferring complex biological assays.


Assuntos
Desenho de Fármacos , Ensaio de Imunoadsorção Enzimática/métodos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...