Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JMIR Form Res ; 7: e44575, 2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-36995742

RESUMO

BACKGROUND: Remote photoplethysmography (rPPG) can record vital signs (VSs) by detecting subtle changes in the light reflected from the skin. Lifelight (Xim Ltd) is a novel software being developed as a medical device for the contactless measurement of VSs using rPPG via integral cameras on smart devices. Research to date has focused on extracting the pulsatile VS from the raw signal, which can be influenced by factors such as ambient light, skin thickness, facial movements, and skin tone. OBJECTIVE: This preliminary proof-of-concept study outlines a dynamic approach to rPPG signal processing wherein green channel signals from the most relevant areas of the face (the midface, comprising the cheeks, nose, and top of the lip) are optimized for each subject using tiling and aggregation (T&A) algorithms. METHODS: High-resolution 60-second videos were recorded during the VISION-MD study. The midface was divided into 62 tiles of 20×20 pixels, and the signals from multiple tiles were evaluated using bespoke algorithms through weighting according to signal-to-noise ratio in the frequency domain (SNR-F) score or segmentation. Midface signals before and after T&A were categorized by a trained observer blinded to the data processing as 0 (high quality, suitable for algorithm training), 1 (suitable for algorithm testing), or 2 (inadequate quality). On secondary analysis, observer categories were compared for signals predicted to improve categories following T&A based on the SNR-F score. Observer ratings and SNR-F scores were also compared before and after T&A for Fitzpatrick skin tones 5 and 6, wherein rPPG is hampered by light absorption by melanin. RESULTS: The analysis used 4310 videos recorded from 1315 participants. Category 2 and 1 signals had lower mean SNR-F scores than category 0 signals. T&A improved the mean SNR-F score using all algorithms. Depending on the algorithm, 18% (763/4212) to 31% (1306/4212) of signals improved by at least one category, with up to 10% (438/4212) improving into category 0, and 67% (2834/4212) to 79% (3337/4212) remaining in the same category. Importantly, 9% (396/4212) to 21% (875/4212) improved from category 2 (not usable) into category 1. All algorithms showed improvements. No more than 3% (137/4212) of signals were assigned to a lower-quality category following T&A. On secondary analysis, 62% of signals (32/52) were recategorized, as predicted from the SNR-F score. T&A improved SNR-F scores in darker skin tones; 41% of signals (151/369) improved from category 2 to 1 and 12% (44/369) from category 1 to 0. CONCLUSIONS: The T&A approach to dynamic region of interest selection improved signal quality, including in dark skin tones. The method was verified by comparison with a trained observer's rating. T&A could overcome factors that compromise whole-face rPPG. This method's performance in estimating VS is currently being assessed. TRIAL REGISTRATION: ClinicalTrials.gov NCT04763746; https://clinicaltrials.gov/ct2/show/NCT04763746.

2.
JMIR Form Res ; 6(11): e36340, 2022 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-36374541

RESUMO

BACKGROUND: The detection of early changes in vital signs (VSs) enables timely intervention; however, the measurement of VSs requires hands-on technical expertise and is often time-consuming. The contactless measurement of VSs is beneficial to prevent infection, such as during the COVID-19 pandemic. Lifelight is a novel software being developed to measure VSs by remote photoplethysmography based on video captures of the face via the integral camera on mobile phones and tablets. We report two early studies in the development of Lifelight. OBJECTIVE: The objective of the Vital Sign Comparison Between Lifelight and Standard of Care: Development (VISION-D) study (NCT04763746) was to measure respiratory rate (RR), pulse rate (PR), and blood pressure (BP) simultaneously by using the current standard of care manual methods and the Lifelight software to iteratively refine the software algorithms. The objective of the Vital Sign Comparison Between Lifelight and Standard of Care: Validation (VISION-V) study (NCT03998098) was to validate the use of Lifelight software to accurately measure VSs. METHODS: BP, PR, and RR were measured simultaneously using Lifelight, a sphygmomanometer (BP and PR), and the manual counting of RR. Accuracy performance targets for each VS were defined from a systematic literature review of the performance of state-of-the-art VSs technologies. RESULTS: The VISION-D data set (17,233 measurements from 8585 participants) met the accuracy targets for RR (mean error 0.3, SD 3.6 vs target mean error 2.3, SD 5.0; n=7462), PR (mean error 0.3, SD 4.0 vs mean error 2.2, SD 9.2; n=10,214), and diastolic BP (mean error -0.4, SD 8.5 vs mean error 5.5, SD 8.9; n=8951); for systolic BP, the mean error target was met but not the SD (mean error 3.5, SD 16.8 vs mean error 6.7, SD 15.3; n=9233). Fitzpatrick skin type did not affect accuracy. The VISION-V data set (679 measurements from 127 participants) met all the standards: mean error -0.1, SD 3.4 for RR; mean error 1.4, SD 3.8 for PR; mean error 2.8, SD 14.5 for systolic BP; and mean error -0.3, SD 7.0 for diastolic BP. CONCLUSIONS: At this early stage in development, Lifelight demonstrates sufficient accuracy in the measurement of VSs to support certification for a Level 1 Conformité Européenne mark. As the use of Lifelight does not require specific training or equipment, the software is potentially useful for the contactless measurement of VSs by nonclinical staff in residential and home care settings. Work is continuing to enhance data collection and processing to achieve the robustness and accuracy required for routine clinical use. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.2196/14326.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...