Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(8): 1213-5, 2005 Aug.
Artigo em Chinês | MEDLINE | ID: mdl-16329483

RESUMO

A novel chemiluminescence method for the determination of uric acid based on its inhibitory effect on the catalysis of Co2+ for the oxidation of luminol by H2O2 is described. The proposed method is simple, very sensitive and inexpensive. The decrease of cheniluminescence intensity is linearly correlated with uric acid concentration. The calibration graph is linear over the range of 1.0 x 10(-10) - 7.0 x 10(-6) mol x L(-1) and the detection limit is 1.1 x 10(-11) mol x L(-1). The relative standard deviation (RSD) for 5.0 x 10(-8) is 1.9% (n=4). The method has been successfully applied to the determination of uric acid in human urine and serum samples.


Assuntos
Luminescência , Ácido Úrico/sangue , Ácido Úrico/urina , Catálise , Cobalto/química , Humanos , Peróxido de Hidrogênio/química , Concentração de Íons de Hidrogênio , Luminol/química , Oxirredução , Reprodutibilidade dos Testes , Espectrofotometria Ultravioleta , Ácido Úrico/análise
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(6): 844-7, 2005 Jun.
Artigo em Chinês | MEDLINE | ID: mdl-16201354

RESUMO

Based on the chemiluminescence reaction of KMnO4-HNO3-2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside sensitized by HCHO, an analytical method for 2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside by RP-HPLC with chemiluminescence detector was developed. The chromatographic conditions were optimized. AN ODS hypersil column(25 mm x 4.0 mm, 125 x 4.0 mm i.d. 5 microm) was used with acetonitrile--0.3% H3PO4 [25:75, (phi)] as mobile phase, and the flow rate was 0.8 mL x min(-1) at the column temperature of 40 degrees C. The linear range of calibration curve was from 15.75 to 136.5 microg x mL(-1), the detection limit was 11.83 microg x mL(-1) with a concentration of 21 microg x mL(-1) of 2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside, and the recovery was 102%-108%. The relative standard deviation was 3.45% (Cs = 21.0 microg x mL(-1), n = 3). The method has been applied to the determination of 2,3,5,4'-tetrahydroxystilbene-2-O-beta-D-glucoside in a few Chinese medicines, and the results were satisfactory. The method was simple, rapid and highly selective.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Medicamentos de Ervas Chinesas/química , Glucosídeos/análise , Luminescência , Estilbenos/análise , Cápsulas , Cromatografia Líquida de Alta Pressão/instrumentação , Formaldeído/química , Glucosídeos/química , Cinética , Medições Luminescentes/instrumentação , Medições Luminescentes/métodos , Estrutura Molecular , Ácido Nítrico/química , Reprodutibilidade dos Testes , Estilbenos/química , Comprimidos
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 24(4): 399-401, 2004 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-15766140

RESUMO

A novel chemiluminescence method for the determination of Levofloxacin is based on its enhancement effect on thereaction of luminol with H2O2. The calibration graph is linear over the range of 5.53 x 10(-11)-2.21 x 10(-8) mol x L(-1) and the detection limit is 1.38 x 10(-11) mol x L(-1). The relative standard deviation (RSD) is 2.56% (n = 9). The method has been successfully applied to the determination of Levofloxacin in capsule samples.


Assuntos
Levofloxacino , Luminescência , Medições Luminescentes/métodos , Luminol/química , Ofloxacino/análise , Preparações Farmacêuticas/análise , Calibragem , Análise de Injeção de Fluxo , Peróxido de Hidrogênio/química , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...