Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Med Phys ; 39(6Part4): 3631, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28519518

RESUMO

PURPOSE: The major concern with CT fluoroscopy is patient radiation dose, which is determined by applied technical parameters as well as practitioner/operator practice, e.g. habits and choice of dose saving features. This study is to investigate the effects of these intangible factors on patient doses. METHODS: 381 patients underwent CT biopsy were retrospectively studied. Patient doses (dose length product, DLP) were analyzed and compared. Comparisons were made among physicians using only conventional intermittent shots, physicians using a low mA dose saving feature, and physicians using a combination of both. Linear regression analyses were performed to investigate any possible relationship between the variables and the patient dose. The Patient detriment index (PDI) was developed to set a threshold for the purpose of the Joint Commission sentinel dose events monitoring. An odds ratio was calculated to determine the odds of a group of patients receiving a dose above the median threshold when compared to another group. RESULTS: The median DLP for all physicians was 1194 mGy-cm. There is a significant difference (p<0.01) between the doses patients received (DLP=539.8 ±76 mGy-cm) when physicians used dose saving feature vs. when the feature was not used (DLP=1269.7±659 mGy-cm). In general, those physicians who used dose saving feature have a lower relative PDI (<1) compared to the PDIs (>1) without dose feature. This is not absolute since some physicians who did not use the dose saving feature have PDIs

2.
Med Phys ; 39(6Part4): 3632, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28519537

RESUMO

PURPOSE: To explore recent advances in available dose metrics and dose reduction features and their impacts during various fluoroscopy procedures. METHODS: Besides traditional dose metrics (cumulative dose, DAP, etc), recent methods such as real time dose mapping and dose calculation from DICOM information and their relevance to entrance skin exposure (ESE) are demonstrated. Dose reduction features and their potential effects on ESE are explored for different interventional procedures, including dose setting options, frame rate settings, wedges, software options and how these help reduce patient dose, etc. Real time dose monitoring techniques such as DoseAware are investigated. Dose alert such as flagging higher doses at about half of the Joint Commission sentinel event limit, Dose Index Registry and their impacts are discussed. Habit related practices, such as a physician leaning over patients, are highlighted, also taking foot off the fluoroscopy pedal when not needed, and best places to stand are illustrated. A practice improvement procedure involving measurement, analysis and improvement actions is instituted. We also discuss the impact of physician follow up letters to patients who might not have reached the JC Sentinel Event limits but may still have skin issues. RESULTS: In our institutes, these efforts have led to reduction of both patient dose and personnel exposure for interventional procedures. The recording of technical parameters and fluoroscopy dose by the staff has led to a better understanding of appropriate dose levels and technique settings for each procedure. CONCLUSIONS: This article can serve as a refresher for radiological staff on how to protect patients and themselves from high doses, while providing the best care possible. It can also serve as criteria for health care providers to institute changes and make quality improvement in interventional practices.

3.
Acta Trop ; 112(1): 49-53, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19539590

RESUMO

Many societies use locally sourced mosquito nets made from a variety of materials. For protecting against malaria these require regular re-treatment with insecticide. K-O Tab 1-2-3 is a 'dip-it-yourself' long-lasting formulation with time-limited interim recommendation from WHO for treatment of washed white and coloured polyester nets for up to 15 washes. To determine wash-resistance on different fabrics, nets made of polyester, polyethylene, cotton or nylon were treated with K-O Tab 1-2-3 and washed up to 20 times using standard WHO washing procedures. Efficacy was assessed using cone and cylinder bioassays and tunnel tests, and deltamethrin content using high-pressure liquid chromatography. Polyethylene and cotton nets treated with K-O Tab 1-2-3 and washed 20 times achieved the WHO threshold of >80% mortality in tunnel tests. Polyethylene matched the performance of polyester in all bioassays in contrast to cotton and nylon which produced low mortality and knock-down in cone and cylinder bioassays. After 20 washes 16.5% of the loading dose of deltamethrin remained on the polyester nets compared with 28.7% on polyethylene, 38.9% on cotton and 2.2% on nylon. Cotton nets retained a high concentration of insecticide but the relatively poor performance in terms of knock-down and mortality suggest most insecticide is bound within the cotton fibres rather than on the surface. K-O Tab 1-2-3 renders insecticide wash fast on polyethylene nets, less so on cotton and nylon. Nets made from polyethylene can be treated in the home to render the insecticide long lasting.


Assuntos
Culicidae/efeitos dos fármacos , Inseticidas/farmacologia , Controle de Mosquitos/métodos , Nitrilas/farmacologia , Equipamentos de Proteção , Piretrinas/farmacologia , Animais , Estabilidade de Medicamentos , Feminino , Zeladoria
4.
Vet Radiol Ultrasound ; 40(3): 318-22, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10519314

RESUMO

Portal radiographs, radiographs made to document the accuracy of radiotherapy treatment fields, are typically of poor image contrast. Recently, a new portal film and screened-cassette system was marketed, the Kodak EC-L system, with the claim of greatly improved image contrast. This new EC-L system was tested on a canine cadaver exposed to Cobalt-60 teletherapy gamma radiation, and image quality was compared to earlier marketed Kodak portal film products. The EC-L system was found to provide portal images of improved contrast/quality.


Assuntos
Radiografia/veterinária , Radioterapia/veterinária , Tecnologia Radiológica/veterinária , Animais , Cães , Radiografia/instrumentação , Radioterapia/instrumentação , Ecrans Intensificadores para Raios X
5.
J Cutan Laser Ther ; 1(3): 135-43, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-11360409

RESUMO

The perception of unwanted hair is culturally dependent, and its removal is a multibillion-dollar business in North America each year. Examples of hair removal techniques on the market today include shaving, depilatories, wax, epilation, electrolysis and photo-epilation. Electrolysis, or electrothermolysis, was the only known permanent hair removal modality to date. However, long term or permanent hair removal with lasers is becoming a reality for treatment of hirsuitism or unwanted hair. Laser hair removal is an exciting new field with improvements occurring continually, making it difficult to stay abreast of the newest treatments and their effectiveness. This review provides an overview of hair follicle anatomy, mechanisms of photo-destruction to hair follicles and physics of lasers and the skin. The different types of lasers used for hair removal, their mechanisms and clinical research are reviewed.


Assuntos
Remoção de Cabelo/métodos , Fotocoagulação/métodos , Desenho de Equipamento , Folículo Piloso/anatomia & histologia , Folículo Piloso/fisiologia , Humanos , Fotocoagulação a Laser/instrumentação , Fotocoagulação a Laser/métodos , Lasers , Fotocoagulação/instrumentação
6.
Nurs Manage ; 29(6): 31-3, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9807425

RESUMO

Internal customers often are overlooked when business techniques are applied. By applying common external customer satisfaction survey techniques to internal business functions, one hospital identified areas for improvement.


Assuntos
Unidades Hospitalares/normas , Supervisão de Enfermagem/organização & administração , Satisfação do Paciente , Gestão da Qualidade Total/organização & administração , Humanos , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...