J Clin Monit Comput ; 20(2): 95-100, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16779622

RESUMO

OBJECTIVE: Compare airway pressure measurements at the ventilator Y-piece of the breathing circuit (P( Y )) to intratracheal pressure measured at the distal end (P( T )) of the endotracheal tube (ETT) during mechanical ventilation and spontaneous breathing of intubated children. METHODS: Thirty children (age range 29 days to 5 years) receiving general anesthesia were intubated with an ETT incorporating a lumen embedded in its sidewall that opened at the distal end to measure P( T ). Peak inflation pressure (PIP) was measured at P( Y ) and P( T ) during positive pressure ventilation. Just before extubation, all measurements were repeated and imposed resistive work of breathing (WOBi) was calculated at both sites while breathing spontaneously. RESULTS: Average PIP was approximately 25% greater at P( Y ) (19.7 +/- 3.4 cm H(2)O) vs. P( T ) (15.0 +/- 2.9 cm H(2)O), p < 0.01. During spontaneous inhalation P( T ) was 59% lower ({bond}8.5 +/- 4.0 cm H(2)O) vs. P( Y ) ({bond}3.5 +/- 2.0 cm H(2)O), p < 0.01. WOBi measured at P( Y ) (0.10 +/- 0.02 Joule/L) was 86% less than WOBi measured at P( T ) (0.70 +/- 0.40 Joule/L), p < 0.01. CONCLUSIONS: In healthy children P( Y ) significantly overestimates PIP in the trachea during positive pressure ventilation and underestimates the intratracheal airway pressure during spontaneous inhalation. During positive pressure ventilation P( T ) better assesses the pressure generated in the airways and lungs compared to P( Y ) because P( T ) also includes the difference in airway pressure across the ETT tube due to resistance. During spontaneous inhalation, P( T ) reflects the series resistance of the ETT and ventilator circuit, while P( Y ) reflects only the resistance of the ventilator circuit, accounting for the smaller decreases in pressure. Additionally, P( Y ) underestimates the total WOBi load on the respiratory muscles. Thus, P( T ) is a more accurate reflection of pulmonary airway pressures than P( Y ) and suggests that it should be incorporated into ventilator systems to more accurately trigger the ventilator and to reduce work of breathing.


Assuntos
Intubação Intratraqueal/instrumentação , Intubação Intratraqueal/métodos , Respiração Artificial/métodos , Respiração , Insuficiência Respiratória , Anestesia Geral , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Respiração com Pressão Positiva , Respiração Artificial/instrumentação , Fenômenos Fisiológicos Respiratórios , Sistema Respiratório , Ventiladores Mecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...