1.
Clin Ophthalmol ; 9: 2313-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26715834

RESUMO

PURPOSE: To assess the safety and efficacy of one, two, or three trabecular microbypass stents in eyes with primary open-angle glaucoma (OAG) not controlled on ocular hypotensive medication. A total of 119 subjects were followed for 18 months postoperatively. MATERIALS AND METHODS: Subjects with medicated intraocular pressure (IOP) 18-30 mmHg and postmedication-washout baseline IOP 22-38 mmHg were randomized to implantation of one, two, or three stents. Ocular hypotensive medication was to be used if postoperative IOP exceeded 18 mmHg. RESULTS: A total of 38 subjects were implanted with one stent, 41 subjects with two stents, and 40 subjects with three stents. Both month 12 IOP reduction ≥20% without ocular hypotensive medication vs baseline unmedicated IOP and month 12 unmedicated IOP ≤18 mmHg were achieved by 89.2%, 90.2%, and 92.1% of one-, two-, and three-stent eyes, respectively. Furthermore, 64.9%, 85.4%, and 92.1% of the three respective groups achieved unmedicated IOP ≤15 mmHg. Over the 18-month follow-up period, medication was required in seven one-stent subjects, four two-stent subjects, and three three-stent subjects. At 18 months, mean unmedicated IOP was 15.9±0.9 mmHg in one-stent subjects, 14.1±1.0 mmHg in two-stent subjects, and 12.2±1.1 mmHg in three-stent subjects. Month 18 IOP reduction was significantly greater (P<0.001) with implantation of each additional stent, with mean differences in reduction of 1.84 mmHg (95% confidence interval 0.96-2.73) for three-stent vs two-stent groups and 1.73 mmHg (95% confidence interval 0.83-2.64) for two-stent vs one-stent groups. Adverse events through 18 months were limited to cataract progression with best-corrected visual acuity loss and subsequent cataract surgery. CONCLUSION: In this series, implantation of each additional stent resulted in significantly greater IOP reduction with reduced medication use. Titratability of stents as a sole procedure was shown to be effective and safe, with sustained effect through 18 months postoperatively in OAG not controlled with medication.

2.
J Nucleic Acids ; 2013: 801505, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24455204

RESUMO

Large-scale genomics projects are identifying biomarkers to detect human disease. B. pseudomallei and B. mallei are two closely related select agents that cause melioidosis and glanders. Accurate characterization of metagenomic samples is dependent on accurate measurements of genetic variation between isolates with resolution down to strain level. Often single biomarker sensitivity is augmented by use of multiple or panels of biomarkers. In parallel with single biomarker validation, advances in DNA sequencing enable analysis of entire genomes in a single run: population-sequencing. Potentially, direct sequencing could be used to analyze an entire genome to serve as the biomarker for genome identification. However, genome variation and population diversity complicate use of direct sequencing, as well as differences caused by sample preparation protocols including sequencing artifacts and mistakes. As part of a Department of Homeland Security program in bacterial forensics, we examined how to implement whole genome sequencing (WGS) analysis as a judicially defensible forensic method for attributing microbial sample relatedness; and also to determine the strengths and limitations of whole genome sequence analysis in a forensics context. Herein, we demonstrate use of sequencing to provide genetic characterization of populations: direct sequencing of populations.

3.
J Cataract Refract Surg ; 38(8): 1339-45, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22814041

RESUMO

PURPOSE: To assess the long-term safety and efficacy of a single trabecular micro-bypass stent with concomitant cataract surgery versus cataract surgery alone for mild to moderate open-angle glaucoma. SETTING: Twenty-nine investigational sites, United States. DESIGN: Prospective randomized controlled multicenter clinical trial. METHODS: Eyes with mild to moderate glaucoma with an unmedicated intraocular pressure (IOP) of 22 mm Hg or higher and 36 mm Hg or lower were randomly assigned to have cataract surgery with iStent trabecular micro-bypass stent implantation (stent group) or cataract surgery alone (control group). Patients were followed for 24 months postoperatively. RESULTS: The incidence of adverse events was low in both groups through 24 months of follow-up. At 24 months, the proportion of patients with an IOP of 21 mm Hg or lower without ocular hypotensive medications was significantly higher in the stent group than in the control group (P=.036). Overall, the mean IOP was stable between 12 months and 24 months (17.0 mm Hg ± 2.8 [SD] and 17.1 ± 2.9 mm Hg, respectively) in the stent group but increased (17.0 ± 3.1 mm Hg to 17.8 ± 3.3 mm Hg, respectively) in the control group. Ocular hypotensive medication was statistically significantly lower in the stent group at 12 months; it was also lower at 24 months, although the difference was no longer statistically significant. CONCLUSIONS: Patients with combined single trabecular micro-bypass stent and cataract surgery had significantly better IOP control on no medication through 24 months than patients having cataract surgery alone. Both groups had a similar favorable long-term safety profile. FINANCIAL DISCLOSURE: Dr. Craven was an investigator in the clinical trial of the iStent. Dr. Katz is a consultant to Glaukos and was the medical monitor for the clinical trial of the iStent. Dr. Katz is a stockholder in Glaukos. Mr. Wells and Ms. Giamporcaro are employees of Glaukos.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Implante de Lente Intraocular , Facoemulsificação , Implantação de Prótese , Stents , Malha Trabecular/cirurgia , Catarata/complicações , Glaucoma de Ângulo Aberto/complicações , Humanos , Pressão Intraocular/fisiologia , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia , Campos Visuais/fisiologia
4.
Ophthalmology ; 118(3): 459-67, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20828829

RESUMO

OBJECTIVE: To assess the safety and efficacy of the iStent trabecular micro-bypass stent (Glaukos Corporation, Laguna Hills, CA) in combination with cataract surgery in subjects with mild to moderate open-angle glaucoma. DESIGN: Prospective, randomized, open-label, controlled, multicenter clinical trial. PARTICIPANTS: A total of 240 eyes with mild to moderate open-angle glaucoma with intraocular pressure (IOP) ≤24 mmHg controlled on 1 to 3 medications were randomized to undergo cataract surgery with iStent implantation (treatment group) or cataract surgery only (control). Fifty additional subjects were enrolled to undergo cataract surgery with iStent implantation under protocol expansion. Data in this report are based on the first 240 eyes enrolled. INTERVENTION: Implantation of the iStent trabecular micro-bypass stent in conjunction with cataract surgery or cataract surgery only. MAIN OUTCOME MEASURES: The primary efficacy measure was unmedicated IOP ≤21 mmHg at 1 year. A secondary measure was unmedicated IOP reduction ≥20% at 1 year. Safety measures included best-corrected visual acuity (BCVA), slit-lamp observations, complications, and adverse events. RESULTS: The study met the primary outcome, with 72% of treatment eyes versus 50% of control eyes achieving the criterion (P<0.001). At 1 year, IOP in both treatment groups was statistically significantly lower from baseline values. Sixty-six percent of treatment eyes versus 48% of control eyes achieved ≥20% IOP reduction without medication (P = 0.003). The overall incidence of adverse events was similar between groups with no unanticipated adverse device effects. CONCLUSIONS: Pressure reduction on fewer medications was clinically and statistically significantly better 1 year after stent plus cataract surgery versus cataract surgery alone, with an overall safety profile similar to that of cataract surgery alone.


Assuntos
Catarata/complicações , Glaucoma de Ângulo Aberto/cirurgia , Facoemulsificação , Stents , Malha Trabecular/cirurgia , Idoso , Humor Aquoso/metabolismo , Feminino , Glaucoma de Ângulo Aberto/complicações , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Intubação/métodos , Implante de Lente Intraocular , Masculino , Estudos Prospectivos , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
5.
Proc Natl Acad Sci U S A ; 103(5): 1173-7, 2006 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-16432242

RESUMO

We create long polymer nanotubes by directly pulling on the membrane of polymersomes using either optical tweezers or a micropipette. The polymersomes are composed of amphiphilic diblock copolymers, and the nanotubes formed have an aqueous core connected to the aqueous interior of the polymersome. We stabilize the pulled nanotubes by subsequent chemical cross-linking. The cross-linked nanotubes are extremely robust and can be moved to another medium for use elsewhere. We demonstrate the ability to form networks of polymer nanotubes and polymersomes by optical manipulation. The aqueous core of the polymer nanotubes together with their robust character makes them interesting candidates for nanofluidics and other applications in biotechnology.