Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-1022937

RESUMO

The Elekta Synergy Linear Accelerator in some hospital from 2012 to 2022 were retrospectively analyzed in terms of operation,failure time distribution and failure of each system.Some countermeasures were put forward accordingly to decrease the failure rate and strengthen the training of relevant personnel's operation and maintenance.References were provided for effective management and operation of medical linear accelerators.

2.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-928916

RESUMO

OBJECTIVE@#In order to grasp the quality status of the first-aid ventilator in pre-hospital and field environment in time, the quality control and detection items of invasive ventilator were optimized to form a rapid detection operation process of first-aid ventilator and ensure the safety of patient treatment.@*METHODS@#Based on the quality control detection data of invasive ventilator in hospital in recent years, methods such as narrowing the range of qualified criteria and analyzing confidence interval were adopted to extract indicators prone to deviation and verify their correlation with similar indicators, so as to form an optimized rapid detection portfolio.@*RESULTS@#Compared with the original quality control detection procedures, the detection indicators of the rapid detection procedures were reduced from 5 categories of 24 indicators to 3 categories of 7 indicators. The detection time was shortened by 56.1% and the coincidence rate of the detection results was 100% after the actual measurement and verification.@*CONCLUSIONS@#Under the premise of ensuring the testing quality, the operating procedure for rapid detection of emergency ventilator can greatly reduce the detection time, and realize the rapid and high frequency quality control detection, so as to ensure the quality and safety of the equipment.


Assuntos
Humanos , Serviços de Assistência Domiciliar , Controle de Qualidade , Ventiladores Mecânicos
3.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-819470

RESUMO

OBJECTIVE@#To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens (IOLs), or the MCX11 ASP IOLs or the spherical IOLs (HQ-201HEP).@*METHODS@#Prospective nonrandomized controlled trial was used. A total of 105 patients (210 eyes) were divided into three groups according to the type of IOLs: ZA9003 (35 patients, 70 eyes), MCX11 ASP (35 patients, 70 eyes) or HQ-201HEP (35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration (SA) and total higher-order aberrations (HOAs).@*RESULTS@#The global score was significantly lower in the spherical IOL group than the aspherical IOL group of -020 μm SA (P  0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs.@*CONCLUSION@#Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations.

4.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-972589

RESUMO

Objective To compare patient-reported outcomes after implantation of the ZA9003 intraocular lens (IOLs), or the MCX11 ASP IOLs or the spherical IOLs (HQ-201HEP). Methods Prospective nonrandomized controlled trial was used. A total of 105 patients (210 eyes) were divided into three groups according to the type of IOLs: ZA9003 (35 patients, 70 eyes), MCX11 ASP (35 patients, 70 eyes) or HQ-201HEP (35 patients, 70 eyes). The main outcome was scores of Catquest nine-item short-form questionnaire. Additional outcome was best corrected visual acuities, spherical aberration (SA) and total higher-order aberrations (HOAs). Results The global score was significantly lower in the spherical IOL group than the aspherical IOL group of −020 μm SA (P 0.05). Significant differences were also found in question 2, question 5, question 6 and question 8 between the spherical IOLs and the aspherical IOLs. Conclusion Implantation of an aspherical IOL could improve vision-related quality of life compared with a spherical IOL. However, there were no statistically significant differences in vision-related quality of life between aspheric IOLs with different negative spherical aberrations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA