Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
4.
Heart Rhythm ; 21(3): 250-257, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38036235

RESUMO

BACKGROUND: Pulsed-field ablation (PFA) is a nonthermal energy source for ablation of cardiac arrhythmias. This study investigated the prospective outcomes of a novel PFA generator in conjunction with a commercially available, contact force-sensing, focal ablation catheter. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and lesion characteristics of point-by-point PFA in consecutive patients undergoing repeat ablation of atrial fibrillation (AF). METHODS: The study involved reisolation of pulmonary veins (PVs) with electrical reconnection and the creation of an anterior line (AL) in patients with anterior substrate or durable pulmonary vein isolation (PVI). RESULTS: In 24 patients (46% female; mean age 67 ± 10 years; 67% persistent AF), successful reisolation of 27 of 27 reconnected PVs (100%) was performed. In 19 patients, AL ablation was performed, with bidirectional block in 16 (84%), median ablation time 26 [21, 33] minutes, and first-pass bidirectional block in 13 patients (68%). Acute AL reconduction occurred in 8 of 19 patients (42%). Among these 8 patients, a subsequent sustained block of the AL was achieved in 5 (63%). Ultra-high-density electroanatomic mapping revealed homogeneous but relatively large low-voltage areas in the ablated regions. Median procedural, left atrial dwell, and fluoroscopy times were 100 [90, 109] minutes, 83 [75, 98] minutes, and 10 [8, 13] minutes, respectively. No major or minor complications occurred. CONCLUSION: This study demonstrated feasibility, acute efficacy, and safety of point-by-point PFA for repeat PVI and AL ablation. Further studies are warranted to assess the long-term durability and comparison with established ablation methods.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Veias Pulmonares/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Átrios do Coração , Ablação por Cateter/métodos , Recidiva
5.
J Clin Invest ; 133(24)2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37856217

RESUMO

A20 is a ubiquitin-modifying protein that negatively regulates NF-κB signaling. Mutations in A20/TNFAIP3 are associated with a variety of autoimmune diseases, including multiple sclerosis (MS). We found that deletion of A20 in central nervous system (CNS) endothelial cells (ECs) enhances experimental autoimmune encephalomyelitis (EAE), a mouse model of MS. A20ΔCNS-EC mice showed increased numbers of CNS-infiltrating immune cells during neuroinflammation and in the steady state. While the integrity of the blood-brain barrier (BBB) was not impaired, we observed a strong activation of CNS-ECs in these mice, with dramatically increased levels of the adhesion molecules ICAM-1 and VCAM-1. We discovered ICOSL to be expressed by A20-deficient CNS-ECs, which we found to function as adhesion molecules. Silencing of ICOSL in CNS microvascular ECs partly reversed the phenotype of A20ΔCNS-EC mice without reaching statistical significance and delayed the onset of EAE symptoms in WT mice. In addition, blocking of ICOSL on primary mouse brain microvascular ECs impaired the adhesion of T cells in vitro. Taken together, we propose that CNS EC-ICOSL contributes to the firm adhesion of T cells to the BBB, promoting their entry into the CNS and eventually driving neuroinflammation.


Assuntos
Encefalomielite Autoimune Experimental , Doenças Neuroinflamatórias , Proteína 3 Induzida por Fator de Necrose Tumoral alfa , Animais , Camundongos , Barreira Hematoencefálica/metabolismo , Sistema Nervoso Central/metabolismo , Células Endoteliais/metabolismo , Camundongos Endogâmicos C57BL , Esclerose Múltipla/metabolismo , Doenças Neuroinflamatórias/metabolismo , Linfócitos T/metabolismo , Ligante Coestimulador de Linfócitos T Induzíveis/metabolismo , Proteína 3 Induzida por Fator de Necrose Tumoral alfa/metabolismo
6.
Sci Rep ; 13(1): 14525, 2023 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-37666935

RESUMO

Arterial hypertension is considered a risk factor for the development of heart failure. Here we investigate cross-sectional associations of systolic and diastolic blood pressure with subtle functional and morphological changes of left ventricular echocardiographic parameters representing early dysfunction in three representative German population-based studies. We assessed 26,719 individuals without symptomatic heart failure from the Hamburg City Health Study (HCHS, n = 7396, derivation cohort), the Gutenberg Health Study (GHS, 14,715, validation cohort) and the Study of Health in Pomerania (SHIP, 4608, validation cohort). Multivariable linear regression analyses with systolic and diastolic blood pressure as continuous exposure variables were adjusted for common cardiovascular risk factors and antihypertensive medication. Both systolic and diastolic blood pressure were consistently associated with measures of left ventricular hypertrophy (ß per standard deviation (SD) for LV mass (g) and systolic blood pressure: 5.09 (p < 0.001); diastolic blood pressure: 2.29 (p < 0.001) in HCHS). Systolic blood pressure correlated with declining diastolic function (ß per SD for E/e': 0.29, p < 0.001 in HCHS) and diastolic blood pressure with declining systolic function (ß per SD for LVEF, in %: - 0.15; p = 0.041 in HCHS) in all cohorts. Pending further validation, our results from three independent German population samples suggest differential effects of systolic versus diastolic blood pressure on left ventricular structure and function.


Assuntos
Ecocardiografia , Insuficiência Cardíaca , Humanos , Pressão Sanguínea , Estudos Transversais , Fenótipo
8.
Clin Cardiol ; 46(10): 1210-1219, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37526378

RESUMO

BACKGROUND: Although electrophysiological (EP) centers have institutional standards, evidence on management of cardiac tamponade is lacking. AIM AND METHODS: A physician-based survey was conducted by sending out questionnaires to all hospitals in Germany performing EP procedures. To evaluate the infrastructure of EP centers and the impact of center volume and onsite cardiac surgery on the management of cardiac tamponade, the results of the survey were analyzed for low-volume (0-250 procedures per year), mid-volume (250-500 procedures), and high-volume (>500 procedures) centers, as well as for centers with and without onsite cardiac surgery. RESULTS: A total of 341 centers were identified and 189/341 (55%) returned data sets were analyzed. Most types of EP procedures are performed across all kinds of centers. Ablation of ventricular tachycardia (VT) is concentrated in higher volume centers and in centers with onsite cardiac surgery. None of the participating low-volume centers and only 13% of centers without onsite cardiac surgery responded to performing epicardial VT ablation. Irrespective of center volume and onsite cardiac surgery, neither body mass index nor age was reported to be an exclusion criterion for ablation procedures. Higher volume centers and centers with onsite cardiac surgery more often have dedicated EP laboratories and EP-nursing teams. Also, differences regarding periprocedural safety precautions and management of cardiac tamponade were found for low-, mid-, and high-volume centers, as well as for centers with and without onsite cardiac surgery. CONCLUSION: While center volume and onsite cardiac surgery do not impact patient selection, there are differences in ablation spectrum, infrastructure, periprocedural safety precautions, and treatment of tamponade.


Assuntos
Tamponamento Cardíaco , Ablação por Cateter , Taquicardia Ventricular , Humanos , Tamponamento Cardíaco/etiologia , Tamponamento Cardíaco/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/terapia , Taquicardia Ventricular/cirurgia , Alemanha/epidemiologia , Ablação por Cateter/métodos , Eletrofisiologia , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37473404

RESUMO

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Veias Pulmonares/cirurgia , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres
10.
Circ J ; 87(7): 950-956, 2023 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-37286488

RESUMO

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Resultado do Tratamento , Ablação por Cateter/métodos , Fibrilação Atrial/cirurgia , Átrios do Coração , Veias Pulmonares/cirurgia , Catéteres , Recidiva
11.
Front Cardiovasc Med ; 10: 1156500, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37034336

RESUMO

Background: Cryoballoon (CB)- based pulmonary vein isolation (PVI) remains guided by fluoroscopy and dye. The novel saline injection-based occlusion tool allows for pulmonary vein (PV)-occlusion assessment without the need for dye injection. Aim: To compare KODEX-EPD guided CB-PVI using the novel saline injection-based workflow with conventional cryoablation for acute efficacy, fluoroscopy exposure and dye volume. Methods: Consecutive atrial fibrillation (AF)- patients undergoing CB-PVI in conjunction with KODEX-EPD (CryoEPD group) were analyzed. Patients undergoing conventional CB-PVI (Cryo group) in the same time period acted as controls. Results: One hundred forty patients [91/140 (65%) persistent AF] were studied. Seventy patients underwent CryoEPD procedures [64 ± 13 years, 21 (30%) female] and seventy patients underwent Cryo procedures [68 ± 10 years, 27 (39%) female].A total of 560 PVs were identified and successfully isolated. Mean procedure time was 66 ± 15 min for the CryoEPD group, and 65 ± 19 min for the Cryo group (p = 0.3). Fluoroscopy time (CryoEPD 6 ± 4 min; Cryo 13 ± 6 min, p < 0.001) and dose area product (CryoEPD 193 [111; 297] cGycm2; Cryo 381 [268; 614] cGycm2, p < 0.001) were lower in patients undergoing CryoEPD compared with Cryo procedures. No dye was needed in the CryoEPD group while 53 ± 18 ml dye per patient were administered for the Cryo group (p < 0.001). The overall complication rate was comparable between both groups (p = 0.5). Conclusion: KODEX-EPD guided AF-ablation enables dye-free CB-based PVI with reduced fluoroscopy exposure when compared to conventional CB-ablation, without differences in acute procedural outcomes or procedure duration.

13.
Sci Rep ; 13(1): 4668, 2023 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-36949243

RESUMO

Coffee, next to water the most widespread beverage, is attributed both harmful and protective characteristics concerning cardiovascular health. This study aimed to evaluate associations of coffee consumption with cardiac biomarkers, echocardiographic, electrocardiographic parameters and major cardiovascular diseases. We performed a cross-sectional analysis of 9009 participants of the population-based Hamburg City Health Study (HCHS), enrolled between 2016 and 2018 median age 63 [IQR: 55; 69] years. Coffee consumption was classified into three groups: < 3 cups/day (low), 3-4 cups/day (moderate), > 4 cups/day (high). In linear regression analyses adjusted for age, sex, body mass index, diabetes, hypertension, smoking, and additives, high coffee consumption correlated with higher LDL-cholesterol (ß = 5.92; 95% CI 2.95, 8.89; p < 0.001). Moderate and high coffee consumption correlated with lower systolic (ß = - 1.91; 95% CI - 3.04, - 0.78; p = 0.001; high: ß = - 3.06; 95% CI - 4.69, - 1.44; p < 0.001) and diastolic blood pressure (ß = - 1.05; 95% CI - 1.67, - 0.43; p = 0.001; high: ß = - 1.85; 95% CI - 2.74, - 0.96; p < 0.001). Different levels of coffee consumption did neither correlate with any investigated electrocardiographic or echocardiographic parameter nor with prevalent major cardiovascular diseases, including prior myocardial infarction and heart failure. In this cross-sectional analysis, high coffee consumption correlated with raised LDL-cholesterol levels and lower systolic and diastolic blood pressure. However, major cardiovascular diseases including heart failure and its diagnostic precursors were not associated with coffee consumption, connoting a neutral role of coffee in the context of cardiovascular health.


Assuntos
Insuficiência Cardíaca , Infarto do Miocárdio , Humanos , Pessoa de Meia-Idade , Café/efeitos adversos , Pressão Sanguínea , LDL-Colesterol , Estudos Transversais , Ecocardiografia , Fatores de Risco
14.
Nutrients ; 15(3)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36771381

RESUMO

Despite associations of regular coffee consumption with fewer neurodegenerative disorders, its association with microstructural brain alterations is unclear. To address this, we examined the association of coffee consumption with brain MRI parameters representing vascular brain damage, neurodegeneration, and microstructural integrity in 2316 participants in the population-based Hamburg City Health Study. Cortical thickness and white matter hyperintensity (WMH) load were measured on FLAIR and T1-weighted images. Microstructural white matter integrity was quantified as peak width of skeletonized mean diffusivity (PSMD) on diffusion-weighted MRI. Daily coffee consumption was assessed in five groups (<1 cup, 1-2 cups, 3-4 cups, 5-6 cups, >6 cups). In multiple linear regressions, we examined the association between brain MRI parameters and coffee consumption (reference group <1 cup). After adjustment for covariates, 3-4 cups of daily coffee were associated with lower PSMD (p = 0.028) and higher cortical thickness (p = 0.015) compared to <1 cup. Moreover, 1-2 cups per day was also associated with lower PSMD (p = 0.022). Associations with WMH load or other groups of coffee consumption were not significant (p > 0.05). The findings indicate that regular coffee consumption is positively associated with microstructural white matter integrity and cortical thickness. Further research is necessary to determine longitudinal effects of coffee on brain microstructure.


Assuntos
Café , Substância Branca , Humanos , Imageamento por Ressonância Magnética , Encéfalo/diagnóstico por imagem , Substância Branca/diagnóstico por imagem , Neuroimagem
15.
ESC Heart Fail ; 10(2): 975-984, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36482800

RESUMO

AIMS: We aim to develop a pragmatic screening tool for heart failure at the general population level. METHODS AND RESULTS: This study was conducted within the Hamburg-City-Health-Study, an ongoing, prospective, observational study enrolling randomly selected inhabitants of the city of Hamburg aged 45-75 years. Heart failure was diagnosed per current guidelines. Using only digital electrocardiograms (ECGs), a convolutional neural network (CNN) was built to discriminate participants with and without heart failure. As comparisons, known risk variables for heart failure were fitted into a logistic regression model and a random forest classifier. Of the 5299 individuals included into this study, 318 individuals (6.0%) had heart failure. Using only the digital ECGs instead of several risk variables as an input, the CNN provided a comparable predictive accuracy for heart failure versus the logistic regression model and the random forest classifier [area under the curve (AUC) of 0.75, a sensitivity of 0.67 and a specificity of 0.69 for the CNN; AUC 0.77, a sensitivity of 0.63 and a specificity of 0.76 for the logistic regression; AUC 0.79, a sensitivity of 0.67 and a specificity of 0.72 for the random forest classifier]. CONCLUSIONS: Using a CNN build on digital ECGs only and requiring no additional input, we derived a screening tool for heart failure in the general population. This could be perfectly embedded into clinical routine of general practitioners, as it builds on an already established diagnostic tool and does not require additional, time-consuming input. This could help to alleviate the underdiagnosis of heart failure.


Assuntos
Insuficiência Cardíaca , Redes Neurais de Computação , Humanos , Estudos Prospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Algoritmo Florestas Aleatórias , Eletrocardiografia
16.
Europace ; 25(2): 571-577, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36413601

RESUMO

AIMS: Three Tesla (T) magnetic resonance imaging (MRI) provides critical imaging information for many conditions. Owing to potential interactions of the magnetic field, it is largely withheld from patients with cardiac implantable electronic devices (CIEDs). Therefore, we assessed the safety of 3T MRI in patients with '3T MRI-conditional' and 'non-3T MRI-conditional' CIEDs. METHODS AND RESULTS: We performed a retrospective single-centre analysis of clinically indicated 3T MRI examinations in patients with conventional pacemakers, cardiac resynchronization devices, and implanted defibrillators from April 2020 to May 2022. All CIEDs were interrogated and programmed before and after scanning. Adverse events included all-cause death, arrhythmias, loss of capture, inappropriate anti-tachycardia therapies, electrical reset, and lead or generator failure during or shortly after MRI. Changes in signal amplitude and lead impedance were systematically assessed. Statistics included median and interquartile range. A total of 132 MRI examinations were performed on a 3T scanner in 97 patients. Thirty-five examinations were performed in patients with 'non-3T MRI-conditional' CIEDs. Twenty-six scans were performed in pacemaker-dependent patients. No adverse events occurred during or shortly after MRI. P-wave or R-wave reductions ≥ 50 and ≥ 25%, respectively, were noted after three (2.3%) scans, all in patients with '3T MRI-conditional' CIEDs. Pacing and shock impedance changed by ± 30% in one case (0.7%). Battery voltage and stimulation thresholds did not relevantly change after MRI. CONCLUSION: Pending verification in independent series, our data suggest that clinically indicated MRI scans at 3T field strength should not be withheld from patients with cardiac pacemakers or defibrillators.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Segurança de Equipamentos , Imageamento por Ressonância Magnética/métodos
17.
Chem Res Toxicol ; 35(11): 2068-2084, 2022 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-36302168

RESUMO

N-Nitrosamines (NAs) are a class of reactive organic chemicals that humans may be exposed to from environmental sources, food but also impurities in pharmaceutical preparations. Some NAs were identified as DNA-reactive mutagens and many of those have been classified as probable human carcinogens. Beyond high-potency mutagenic carcinogens that need to be strictly controlled, NAs of low potency need to be considered for risk assessment as well. NA impurities and nitrosylated products of active pharmaceutical ingredients (APIs) often arise from production processes or degradation. Most NAs require metabolic activation to ultimately become carcinogens, and their activation can be appropriately described by first-principles computational chemistry approaches. To this end, we treat NA-induced DNA alkylation as a series of subsequent association and dissociation reaction steps that can be calculated stringently by density functional theory (DFT), including α-hydroxylation, proton transfer, hydroxyl elimination, direct SN2/SNAr DNA alkylation, competing hydrolysis and SN1 reactions. Both toxification and detoxification reactions are considered. The activation reactions are modeled by DFT at a high level of theory with an appropriate solvent model to compute Gibbs free energies of the reactions (thermodynamical effects) and activation barriers (kinetic effects). We study congeneric series of aliphatic and cyclic NAs to identify trends. Overall, this work reveals detailed insight into mechanisms of activation for NAs, suggesting that individual steric and electronic factors have directing and rate-determining influence on the formation of carbenium ions as the ultimate pro-mutagens and thus carcinogens. Therefore, an individual risk assessment of NAs is suggested, as exemplified for the complex API-like 4-(N-nitroso-N-methyl)aminoantipyrine which is considered as low-potency NA by in silico prediction.


Assuntos
Nitrosaminas , Humanos , Nitrosaminas/metabolismo , Carcinógenos/metabolismo , Mutagênicos , DNA , Preparações Farmacêuticas
18.
ESC Heart Fail ; 9(6): 4189-4197, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36101477

RESUMO

AIMS: Data on the association between periodontitis and preclinical cardiac alterations remain scarce. The aim of the current study is to determine if periodontitis is associated with morphological and functional cardiac changes measured by transthoracic echocardiography as well as different heart failure (HF) phenotypes. METHODS: Participants from the population-based Hamburg City Health Study [ClinicalTrial.gov (NCT03934957)], who underwent transthoracic echocardiography and periodontal screening were included. Periodontitis was classified according to Eke and Page (none/mild, moderate, severe). The 2021 ESC HF guidelines were applied and HF was classified into HF with preserved ejection fraction (HFpEF, ejection fraction ≥50%), HF with mid-range and reduced ejection fraction [HF(m)rEF, ejection fraction <50%], and HF in general [HFpEF and HF(m)rEF]. Due to limited size, all subjects with LVEF <50% and symptoms or signs of HF were classified as HF with reduced and mildly reduced ejection fraction [HF(m)rEF]. RESULTS: Within 6209 participants with full periodontal examination, we identified an overlap of n = 167 participants with periodontitis and HF. Participants with severe periodontitis showed a higher burden of cardiovascular risk factors (men at advanced age, diabetes mellitus, hypertension) when compared with participants with none/mild periodontitis. After adjustment for age, sex, body mass index, smoking, diabetes, hypertension, atrial fibrillation, and coronary artery disease, severe periodontitis was significantly associated with HF(m)rEF (odds ratio: 3.16; 95% CI: 1.21, 8.22; P = 0.019), although no association was found for HFpEF and HF in general. CONCLUSIONS: The current study demonstrated that severe periodontitis was significantly associated with HF(m)rEF, although no relevant associations were found with HFpEF and HF in general as well as echocardiographic variables. The results implicate a potential target group, who need special attention from cooperating physicians and dentists. Future studies are warranted to verify whether systemic inflammation could be the link between the two diseases.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Hipertensão , Periodontite , Humanos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Função Ventricular Esquerda , Volume Sistólico , Prognóstico , Hipertensão/complicações , Periodontite/complicações , Periodontite/diagnóstico , Periodontite/epidemiologia
19.
Sci Rep ; 12(1): 15307, 2022 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-36096919

RESUMO

Transthoracic echocardiography (TTE) and cine cardiac magnetic resonance imaging (CMR) are established imaging methods of the aortic root. We aimed to evaluate the comparability of measurements in TTE and standard cine CMR sequences of the aortic root. Our study included 741 subjects (mean age 63.5 ± 8 years, 43.7% female) from the Hamburg City Health Study (HCHS). Subjects underwent CMR and TTE. Aortic root measurements were performed at the level of the aortic annulus (AoAn), sinus of Valsalva (SoV), and sinotubular junction (STJ) by standard cine CMR in left ventricular long axis and left ventricular outflow tract view. Measurements were performed applying the leading-edge to leading-edge (LL) convention and inner-edge to inner-edge (II) convention in TTE and the II convention in CMR. Inter correlation coefficients (ICCs) demonstrated high inter- and intraobserver reproducibility for CMR and TTE measurements of SoV and STJ (ICCs 0.9-0.98) and moderate reproducibility for AoAn (ICCs 0.68-0.91). CMR measurements of SoV and STJ showed strong agreement with TTE: while correlations were comparable (r = 0.75-0.85) bias was lower with TTE II (bias - 0.1 to - 0.74) versus TTE LL measurements (mean bias - 1.49 to - 2.58 mm). The agreement for AoAn was fair (r = 0.51-0.57) with variable bias (mean bias 0.39-3.9). Standard cine CMR and TTE derived aortic root measurements are reproducible and comparable with higher agreement for TTE II instead of LL measurements. These results support an interchangeable application of TTE and standard CMR for screening of aortic root diseases thereby possibly reducing redundant multimodality imaging.


Assuntos
Doenças da Aorta , Ecocardiografia , Idoso , Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...