Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Bone Joint Surg Br ; 94(10): 1403-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23015569

RESUMO

The use of pulsed electromagnetic fields (PEMF) to stimulate bone growth has been recommended as an alternative to the surgical treatment of ununited scaphoid fractures, but has never been examined in acute fractures. We hypothesised that the use of PEMF in acute scaphoid fractures would accelerate the time to union by 30% in a randomised, double-blind, placebo-controlled, multicentre trial. A total of 53 patients in three different medical centres with a unilateral undisplaced acute scaphoid fracture were randomly assigned to receive either treatment with PEMF (n = 24) or a placebo (n = 29). The clinical and radiological outcomes were assessed at four, six, nine, 12, 24 and 52 weeks. A log-rank analysis showed that neither time to clinical and radiological union nor the functional outcome differed significantly between the groups. The clinical assessment of union indicated that at six weeks tenderness in the anatomic snuffbox (p = 0.03) as well as tenderness on longitudinal compression of the scaphoid (p = 0.008) differed significantly in favour of the placebo group. We conclude that stimulation of bone growth by PEMF has no additional value in the conservative treatment of acute scaphoid fractures.


Assuntos
Consolidação da Fratura/efeitos da radiação , Fraturas Ósseas/terapia , Magnetoterapia , Osso Escafoide/lesões , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Moldes Cirúrgicos , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
2.
Eur J Orthop Surg Traumatol ; 21(1): 7-12, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21837232

RESUMO

OBJECTIVE: The purpose of this study is to determine the efficacy of the open reduction and fixation of a dislocated proximal humerus fracture with a locking plate, also evaluating the incidence of complications and functional recovery of the shoulder. A retrospective study focusing on patients who had suffered a fracture of the proximal humerus and were treated by means of an open reduction and internal fixation with a locking plate, using either the Philos or the LPHP plate. We have also included a comparison of these two plates. METHOD: Ninety-two patients were found to be eligible and were included in our study. These patients had all been treated for a proximal humerus fracture between 2002 and 2008. We included those patients who could be classified as a class 2, 3, or 4 according to the Neer classification. Demographic data, surgical technique, and peri/post-operative complications were collected from medical records. Patients were followed-up and the Oxford Shoulder Score (OSS) was filled in by phone. The mean age of our patient population was 66.2 (15-97), with a male: female ratio of 1:5 (15:77). (The median follow-up was 2.4 years (0.2-5.8). Fourteen of our patients died during follow-up, while 25 patients were otherwise lost to follow-up. For this study, out of the original 131 patients, this finally resulted in 92 patients whom we followed-up post-operatively. RESULTS: Ninety-two patients (70%, 92/131) were interviewed. The mean Oxford Shoulder Score (OSS) was 19.76 (11-54). The overall complication rate was 39.1% (36/92). The most frequently occurring complications in our patient population were hemorrhage 3.3%; dislocation of the caput humeri and/or tuberculum majus 2.2%; persistent pain 3.3%; Avascular necrosis (AVN) of the humeral head 0%; Loss of reduction and screw cutout 6.5%; Plate breakout 6.5%; Subacromial Impingement 11.9%; Frozen shoulder 3.3%; rotator cuff rupture 1.1%, and infection 1.1%. Of the entire group of patients originally included in this study, 29% was re-operated due to one of the above-mentioned complications. CONCLUSION: In conclusion, the locking plate provides satisfactory functional outcomes after a mid-term follow-up in patients with displaced proximal humerus fractures. The incidence of complications and subsequent re-operation is relatively high, however, comparable to or slightly better when compared to data found in literature. Subacromial Impingement seems to occur more frequently when a Philos plate is implemented. We therefore suggest that randomized clinical trials determining the possible superiority of one specific type of plate in patients with a displaced proximal humerus fracture are to be performed in future.

3.
Eur J Surg ; 167(5): 382-5, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11419556

RESUMO

OBJECTIVE: To assess the efficacy of isosorbide dinitrate in healing anal fissures. DESIGN: Randomised, prospective, double blind, placebo controlled trial. SETTING: Teaching hospital, The Netherlands. SUBJECTS: 37 consecutive subjects with anal fissure diagnosed in the surgical outpatient department. INTERVENTIONS: After randomisation, 20 patients were given isosorbide dinitrate, and 17 patients placebo. MAIN OUTCOME MEASURES: Healing of anal fissure, recurrence, and tolerance. RESULTS: Both groups were treated for a median (range) of 5 weeks (range 1-10). After this period, 17 in the isosorbide group had healed compared with 6 controls (p < 0.003). The fissure recurred in 2 patients who had had an initial good response to isosorbide, and in 2 in the control group. Side effects (particularly headache) were more common after isosorbide dinitrate, but not significantly so (9/20 compared with 3/17). CONCLUSIONS: Isosorbide dinitrate is an effective treatment for anal fissure, and is significantly better than placebo.


Assuntos
Fissura Anal/tratamento farmacológico , Dinitrato de Isossorbida/uso terapêutico , Vasodilatadores/uso terapêutico , Adulto , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
Artigo em Inglês | MEDLINE | ID: mdl-9200299

RESUMO

Constipation following routine hysterectomy seems to occur more frequently than originally thought. Treatment depends on whether the patient is referred and to whom. Physical examination seems of limited value. Proper protocols for evaluation of complaints after hysterectomy are mandatory. Colonic transit studies and dynamic rectal examination could be useful. We found an overrepresentation of enteroceles in the hysterectomy group. Management of these abnormalities seems much more complicated than was previously thought. Prospective studies are needed to investigate anorectal disorders after hysterectomy.


Assuntos
Constipação Intestinal/etiologia , Histerectomia/efeitos adversos , Canal Anal/fisiopatologia , Colo/fisiopatologia , Constipação Intestinal/fisiopatologia , Constipação Intestinal/terapia , Feminino , Humanos , Manometria , Reto/fisiopatologia
5.
J Appl Physiol (1985) ; 69(4): 1479-85, 1990 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-2262472

RESUMO

We determined maximal exercise capacity and measured hemodynamics in 10 6-wk-old lambs with an aortopulmonary left-to-right shunt [S, 57 +/- 11%, (SD)] and in 9 control lambs (C) during a graded treadmill test 8 days after surgery. Maximal exercise capacity (3.7 +/- 0.2 km/h and 10 +/- 5% inclination vs. 4.0 +/- 0.9 km/h and 15 +/- 0% inclination, P less than 0.02) and peak oxygen consumption (25 +/- 7 vs. 34 +/- 8 ml O2.min-1.kg-1, P less than 0.02) were both lower in the shunt than in the control lambs. This was due to a lower maximal systemic blood flow in the shunt lambs (271 +/- 38 vs. 359 +/- 71 ml.min-1.kg-1, P less than 0.01). Despite their high maximal left ventricular output, which was higher than in the control lambs (448 +/- 87 vs. 359 +/- 71 ml.min-1.kg-1, P less than 0.05), the left-to-right shunt could not be compensated for during maximal exercise because of a decreased reserve in heart rate (S: 183 +/- 22 to 277 +/- 38 beats/min; C: 136 +/- 25 to 287 +/- 29 beats/min) and in left ventricular stroke volume (S: 1.8 +/- 0.3 to 1.6 +/- 0.4 ml/kg; C: 1.0 +/- 0.3 to 1.3 +/- 0.2 ml/kg). We conclude that exercise capacity of shunt lambs is lower than that of control lambs, despite a good left ventricular performance, because a part of the reserves for increasing the left ventricular output is already utilized at rest.


Assuntos
Aorta/fisiologia , Consumo de Oxigênio/fisiologia , Condicionamento Físico Animal , Artéria Pulmonar/fisiologia , Envelhecimento/fisiologia , Animais , Peso Corporal/fisiologia , Hemodinâmica/fisiologia , Hemoglobinas/metabolismo , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...