Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
3.
J Cardiothorac Vasc Anesth ; 38(6): 1309-1313, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38503628

RESUMO

OBJECTIVES: To determine the impact of pressure recovery (PR) adjustment on disease severity grading in patients with severe aortic stenosis. The authors hypothesized that accounting for PR would result in echocardiographic reclassification of aortic stenosis severity in a significant number of patients. DESIGN: A retrospective observational study between October 2013 and February 2021. SETTING: A single-center, quaternary-care academic center. PARTICIPANTS: Adults (≥18 years old) who underwent transcatheter aortic valve implantation (TAVI). INTERVENTIONS: TAVI. MEASUREMENTS AND MAIN RESULTS: A total of 342 patients were evaluated in this study. Left ventricle mass index was significantly greater in patients who continued to be severe after PR (100.47 ± 28.77 v 90.15 ± 24.03, p = < 0.000001). Using PR-adjusted aortic valve area (AVA) resulted in the reclassification of 81 patients (24%) from severe to moderate aortic stenosis (AVA >1.0 cm2). Of the 81 patients who were reclassified, 23 patients (28%) had sinotubular junction (STJ) diameters >3.0 cm. CONCLUSION: Adjusting calculated AVA for PR resulted in a reclassification of a significant number of adult patients from severe to moderate aortic stenosis. PR was significantly larger in patients who reclassified from severe to moderate aortic stenosis after adjusting for PR. PR appeared to remain relevant in patients with STJ ≥3.0 cm. Clinicians need to be aware of PR and how to account for its effect when measuring pressure gradients with Doppler.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Ecocardiografia/métodos
4.
Int J Cardiol Cardiovasc Risk Prev ; 16: 200170, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36874037

RESUMO

Background: Increased afterload affects many of the flow dependent metrics assessed during transthoracic echocardiography (TTE) especially in the evaluation valvular disease. A single timepoint blood pressure (BP) may not accurately reflect the afterload present at the time of flow-dependent imaging and quantification. We assessed the magnitude of change in BP at discrete timepoints during routine TTE. Method: We conducted a prospective study where participants underwent automated BP measurement while undergoing a clinically indicated TTE. The first reading was obtained right after the patient lay supine and subsequent readings were taken at 10-min intervals during image acquisition. Result: We included 50 participants (66% were male, with a mean age of 64 years). After 10 min, 40 (80%) participants had a drop in systolic BP of >10 mmHg. Compared to the baseline, there was a significant drop in systolic BP (mean decrease 20.0 ± 12.8 mmHg; P < 0.05), and diastolic BP (mean decrease 15.7 ± 13.2 mmHg; P < 0.05) at 10 min. The systolic BP remained different from the baseline value throughout the duration of the study (average decrease from baseline to study end was 12.4 ± 16.0 mmHg, p < 0.05). Conclusion: BP recorded just prior to TTE does not accurately reflect the afterload present during most of the study. This finding has important implications for valvular heart disease imaging protocols that incorporate flow dependent metrics, where the presence or absence of hypertension may lead to under- or over-estimation of disease severity.

5.
J Am Soc Echocardiogr ; 36(4): 411-420, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36641103

RESUMO

BACKGROUND: Aortic stenosis (AS) is a degenerative valve condition that is underdiagnosed and undertreated. Detection of AS using limited two-dimensional echocardiography could enable screening and improve appropriate referral and treatment of this condition. The aim of this study was to develop methods for automated detection of AS from limited imaging data sets. METHODS: Convolutional neural networks were trained, validated, and tested using limited two-dimensional transthoracic echocardiographic data sets. Networks were developed to accomplish two sequential tasks: (1) view identification and (2) study-level grade of AS. Balanced accuracy and area under the receiver operator curve (AUROC) were the performance metrics used. RESULTS: Annotated images from 577 patients were included. Neural networks were trained on data from 338 patients (average n = 10,253 labeled images), validated on 119 patients (average n = 3,505 labeled images), and performance was assessed on a test set of 120 patients (average n = 3,511 labeled images). Fully automated screening for AS was achieved with an AUROC of 0.96. Networks can distinguish no significant (no, mild, mild to moderate) AS from significant (moderate or severe) AS with an AUROC of 0.86 and between early (mild or mild to moderate AS) and significant (moderate or severe) AS with an AUROC of 0.75. External validation of these networks in a cohort of 8,502 outpatient transthoracic echocardiograms showed that screening for AS can be achieved using parasternal long-axis imaging only with an AUROC of 0.91. CONCLUSION: Fully automated detection of AS using limited two-dimensional data sets is achievable using modern neural networks. These methods lay the groundwork for a novel method for screening for AS.


Assuntos
Estenose da Valva Aórtica , Aprendizado de Máquina , Humanos , Redes Neurais de Computação , Ecocardiografia/métodos , Reprodutibilidade dos Testes
6.
Clin Cardiol ; 46(1): 76-83, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36273422

RESUMO

BACKGROUND: Adverse cardiac events are common following transcatheter aortic valve replacement (TAVR). Our aim was to investigate the low left ventricular stroke volume index (LVSVI) 30 days after TAVR as an early echocardiographic marker of survival. HYPOTHESIS: Steady-state (30-day) LVSVI after TAVR is associated with 1-year mortality. METHODS: A single-center retrospective analysis of all patients undergoing TAVR from 2017 to 2019. Baseline and 30-day post-TAVR echocardiographic LVSVI were calculated. Patients were stratified by pre-TAVR transaortic gradient, surgical risk, and change in transvalvular flow following TAVR. RESULTS: This analysis focuses on 238 patients treated with TAVR. The 1-year mortality rate was 9% and 124 (52%) patients had normal flow post-TAVR. Of those with pre-TAVR low flow, 67% of patients did not normalize LVSVI at 30 days. The 30-day normal flow was associated with lower 1-year mortality when compared to low flow (4% vs. 14%, p = .007). This association remained significant after adjusting for known predictors of risk (adjusted odds ratio [OR] of 3.45, 95% confidence interval: 1.02-11.63 [per 1 ml/m2 decrease], p = .046). Normalized transvalvular flow following TAVR was associated with reduced mortality (8%) when compared to those with persistent (15%) or new-onset low flow (12%) (p = .01). CONCLUSIONS: LVSVI at 30 days following TAVR is an early echocardiographic predictor of 1-year mortality and identifies patients with worse intermediate outcomes. More work is needed to understand if this short-term imaging marker might represent a novel therapeutic target.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Estudos Retrospectivos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Índice de Gravidade de Doença , Função Ventricular Esquerda , Fatores de Risco
7.
Proc Mach Learn Res ; 219: 285-307, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38463535

RESUMO

Aortic stenosis (AS) is a degenerative valve condition that causes substantial morbidity and mortality. This condition is under-diagnosed and under-treated. In clinical practice, AS is diagnosed with expert review of transthoracic echocardiography, which produces dozens of ultrasound images of the heart. Only some of these views show the aortic valve. To automate screening for AS, deep networks must learn to mimic a human expert's ability to identify views of the aortic valve then aggregate across these relevant images to produce a study-level diagnosis. We find previous approaches to AS detection yield insufficient accuracy due to relying on inflexible averages across images. We further find that off-the-shelf attention-based multiple instance learning (MIL) performs poorly. We contribute a new end-to-end MIL approach with two key methodological innovations. First, a supervised attention technique guides the learned attention mechanism to favor relevant views. Second, a novel self-supervised pretraining strategy applies contrastive learning on the representation of the whole study instead of individual images as commonly done in prior literature. Experiments on an open-access dataset and a temporally-external heldout set show that our approach yields higher accuracy while reducing model size.

8.
JACC Cardiovasc Imaging ; 15(9): 1542-1544, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36075613
10.
Circ Cardiovasc Qual Outcomes ; 15(4): e008487, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35354282

RESUMO

BACKGROUND: While clinical prediction models (CPMs) are used increasingly commonly to guide patient care, the performance and clinical utility of these CPMs in new patient cohorts is poorly understood. METHODS: We performed 158 external validations of 104 unique CPMs across 3 domains of cardiovascular disease (primary prevention, acute coronary syndrome, and heart failure). Validations were performed in publicly available clinical trial cohorts and model performance was assessed using measures of discrimination, calibration, and net benefit. To explore potential reasons for poor model performance, CPM-clinical trial cohort pairs were stratified based on relatedness, a domain-specific set of characteristics to qualitatively grade the similarity of derivation and validation patient populations. We also examined the model-based C-statistic to assess whether changes in discrimination were because of differences in case-mix between the derivation and validation samples. The impact of model updating on model performance was also assessed. RESULTS: Discrimination decreased significantly between model derivation (0.76 [interquartile range 0.73-0.78]) and validation (0.64 [interquartile range 0.60-0.67], P<0.001), but approximately half of this decrease was because of narrower case-mix in the validation samples. CPMs had better discrimination when tested in related compared with distantly related trial cohorts. Calibration slope was also significantly higher in related trial cohorts (0.77 [interquartile range, 0.59-0.90]) than distantly related cohorts (0.59 [interquartile range 0.43-0.73], P=0.001). When considering the full range of possible decision thresholds between half and twice the outcome incidence, 91% of models had a risk of harm (net benefit below default strategy) at some threshold; this risk could be reduced substantially via updating model intercept, calibration slope, or complete re-estimation. CONCLUSIONS: There are significant decreases in model performance when applying cardiovascular disease CPMs to new patient populations, resulting in substantial risk of harm. Model updating can mitigate these risks. Care should be taken when using CPMs to guide clinical decision-making.


Assuntos
Doenças Cardiovasculares , Insuficiência Cardíaca , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Humanos , Medição de Risco/métodos
11.
Lancet ; 399(10330): 1094-1095, 2022 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-35120591
12.
Circ Cardiovasc Qual Outcomes ; 14(8): e007858, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34340529

RESUMO

BACKGROUND: There are many clinical prediction models (CPMs) available to inform treatment decisions for patients with cardiovascular disease. However, the extent to which they have been externally tested, and how well they generally perform has not been broadly evaluated. METHODS: A SCOPUS citation search was run on March 22, 2017 to identify external validations of cardiovascular CPMs in the Tufts Predictive Analytics and Comparative Effectiveness CPM Registry. We assessed the extent of external validation, performance heterogeneity across databases, and explored factors associated with model performance, including a global assessment of the clinical relatedness between the derivation and validation data. RESULTS: We identified 2030 external validations of 1382 CPMs. Eight hundred seven (58%) of the CPMs in the Registry have never been externally validated. On average, there were 1.5 validations per CPM (range, 0-94). The median external validation area under the receiver operating characteristic curve was 0.73 (25th-75th percentile [interquartile range (IQR)], 0.66-0.79), representing a median percent decrease in discrimination of -11.1% (IQR, -32.4% to +2.7%) compared with performance on derivation data. 81% (n=1333) of validations reporting area under the receiver operating characteristic curve showed discrimination below that reported in the derivation dataset. 53% (n=983) of the validations report some measure of CPM calibration. For CPMs evaluated more than once, there was typically a large range of performance. Of 1702 validations classified by relatedness, the percent change in discrimination was -3.7% (IQR, -13.2 to 3.1) for closely related validations (n=123), -9.0 (IQR, -27.6 to 3.9) for related validations (n=862), and -17.2% (IQR, -42.3 to 0) for distantly related validations (n=717; P<0.001). CONCLUSIONS: Many published cardiovascular CPMs have never been externally validated, and for those that have, apparent performance during development is often overly optimistic. A single external validation appears insufficient to broadly understand the performance heterogeneity across different settings.


Assuntos
Doenças Cardiovasculares , Doenças Cardiovasculares/diagnóstico , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/terapia , Humanos , Curva ROC
13.
J Clin Epidemiol ; 138: 32-39, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34175377

RESUMO

OBJECTIVE: To assess whether the Prediction model Risk Of Bias ASsessment Tool (PROBAST) and a shorter version of this tool can identify clinical prediction models (CPMs) that perform poorly at external validation. STUDY DESIGN AND SETTING: We evaluated risk of bias (ROB) on 102 CPMs from the Tufts CPM Registry, comparing PROBAST to a short form consisting of six PROBAST items anticipated to best identify high ROB. We then applied the short form to all CPMs in the Registry with at least 1 validation (n=556) and assessed the change in discrimination (dAUC) in external validation cohorts (n=1,147). RESULTS: PROBAST classified 98/102 CPMS as high ROB. The short form identified 96 of these 98 as high ROB (98% sensitivity), with perfect specificity. In the full CPM registry, 527 of 556 CPMs (95%) were classified as high ROB, 20 (3.6%) low ROB, and 9 (1.6%) unclear ROB. Only one model with unclear ROB was reclassified to high ROB after full PROBAST assessment of all low and unclear ROB models. Median change in discrimination was significantly smaller in low ROB models (dAUC -0.9%, IQR -6.2-4.2%) compared to high ROB models (dAUC -11.7%, IQR -33.3-2.6%; P<0.001). CONCLUSION: High ROB is pervasive among published CPMs. It is associated with poor discriminative performance at validation, supporting the application of PROBAST or a shorter version in CPM reviews.


Assuntos
Pesquisa Biomédica/organização & administração , Estudos Epidemiológicos , Projetos de Pesquisa/estatística & dados numéricos , Projetos de Pesquisa/normas , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Viés , Regras de Decisão Clínica , Análise Discriminante , Humanos , Prognóstico
15.
J Am Heart Assoc ; 10(10): e018978, 2021 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-33960198

RESUMO

Background Transcatheter aortic valve replacement (TAVR) has become the preferred treatment for symptomatic patients with aortic stenosis and elevated procedural risk. Many deaths following TAVR are because of noncardiac causes and comorbid disease burden may be a major determinant of postprocedure outcomes. The prevalence of comorbid conditions and associations with outcomes after TAVR has not been studied. Methods and Results This was a retrospective single-center study of patients treated with TAVR from January 2015 to October 2018. The association between 21 chronic conditions and short- and medium-term outcomes was assessed. A total of 341 patients underwent TAVR and had 1-year follow-up. The mean age was 81.4 (SD 8.0) years with a mean Society of Thoracic Surgeons predicted risk of mortality score of 6.7% (SD 4.8). Two hundred twenty (65%) patients had ≥4 chronic conditions present at the time of TAVR. There was modest correlation between Society of Thoracic Surgeons predicted risk of mortality and comorbid disease burden (r=0.32, P<0.001). After adjusting for Society of Thoracic Surgeons predicted risk of mortality, age, and vascular access, each additional comorbid condition was associated with increased rates of 30-day rehospitalizations (odds ratio, 1.21; 95% CI, 1.02-1.44), a composite of 30-day rehospitalization and 30-day mortality (odds ratio, 1.20; 95% CI, 1.02-1.42), and 1-year mortality (odds ratio, 1.29; 95% CI, 1.05-1.59). Conclusions Comorbid disease burden is associated with worse clinical outcomes in high-risk patients treated with TAVR. The risks associated with comorbid disease burden are not adequately captured by standard risk assessment. A systematic assessment of comorbid conditions may improve risk stratification efforts.


Assuntos
Estenose da Valva Aórtica/cirurgia , Efeitos Psicossociais da Doença , Complicações Pós-Operatórias/economia , Sistema de Registros , Medição de Risco/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Comorbidade/tendências , Feminino , Seguimentos , Mortalidade Hospitalar/tendências , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
16.
Catheter Cardiovasc Interv ; 98(4): 767-773, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-33979472

RESUMO

BACKGROUND: Carotid access has shown promise as an excellent delivery route for transcatheter aortic valve replacement (TAVR). We aimed to compare outcomes of transcarotid (TC) and transfemoral (TF) TAVR by conducting a search and analysis of the best evidence in the literature to shed light on its safety and effectiveness. METHODS: The PubMed/MEDLINE, Embase, and Cochrane library from inception to July 2020 were searched to identify articles reporting comparative data on TC versus TF approaches for TAVR. Patients' baseline characteristics and clinical outcomes were extracted from the articles and pooled for analysis. RESULTS: Five studies, including a total of 2470 patients, were included in the study with 1859 patients in the TF group and 611 patients in the TC group. The TC group had higher prevalence of peripheral vascular disease, while the patients in the TF group was older. Meta-analysis revealed that there was no significant differences between the two groups with regard to 30-day mortality (p = 0.09), stroke (p = 0.28), new dialysis (p = 0.58), major bleeding (p = 0.69), or pacemaker implantation (p = 0.44). The TF group had a higher incidence of vascular complications (3.9% vs. 2.3%; OR 2.22; 95% CI [1.13, 4.38]; p = 0.02). CONCLUSIONS: Compared with the TF approach, TC-TAVR is associated with comparable procedural and clinical outcomes. Our analysis found a lower rate of vascular complication in TC access compared with TF access. This supports consideration of such an alternative access when there are concerns over the feasibility of TF access.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Artéria Femoral/cirurgia , Humanos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
J Am Heart Assoc ; 9(18): e016505, 2020 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-32862771

RESUMO

Background Advanced heart failure (AHF) carries a morbidity and mortality that are similar or worse than many advanced cancers. Despite this, there are no accepted quality metrics for end-of-life (EOL) care for patients with AHF. Methods and Results As a first step toward identifying quality measures, we performed a qualitative study with 23 physicians who care for patients with AHF. Individual, in-depth, semistructured interviews explored physicians' perceptions of characteristics of high-quality EOL care and the barriers encountered. Interviews were analyzed using software-assisted line-by-line coding in order to identify emergent themes. Although some elements and barriers of high-quality EOL care for AHF were similar to those described for other diseases, we identified several unique features. We found a competing desire to avoid overly aggressive care at EOL alongside a need to ensure that life-prolonging interventions were exhausted. We also identified several barriers related to identifying EOL including greater prognostic uncertainty, inadequate recognition of AHF as a terminal disease and dependence of symptom control on disease-modifying therapies. Conclusions Our findings support quality metrics that prioritize receipt of goal-concordant care over utilization measures as well as a need for more inclusive payment models that appropriately reflect the dual nature of many AHF therapies.


Assuntos
Insuficiência Cardíaca/terapia , Médicos/psicologia , Qualidade da Assistência à Saúde , Assistência Terminal/métodos , Adulto , Idoso , Cardiologistas/psicologia , Feminino , Humanos , Entrevistas como Assunto , Masculino , Pessoa de Meia-Idade , Médicos de Atenção Primária/psicologia , Pesquisa Qualitativa , Assistência Terminal/normas
20.
Struct Heart ; 4(4): 295-299, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32905421

RESUMO

BACKGROUND: One third of high- and prohibitive-risk TAVR patients remain severely symptomatic or die 1 year after treatment. There is interest in identifying individuals for whom this procedure is futile and should not be offered. METHODS: We performed a systematic review of the highest reported stratum of risk in TAVR clinical predictive models (CPMs). We explore whether currently available predictive models can identify patients for whom TAVR is futile, based on a quantitative futility definition and the observed and predicted outcomes for patients in the highest stratum of risk. RESULTS: 17 TAVR CPMs representing 69,191 treated patients were published from 2013 to 2018. When reported, the median number of patients in the highest stratum of risk was 569 (range 1 to 1759). Observed mortality for this risk stratum ranged from 9% at 30 days to 59% at 1 year after TAVR. Statistical confidence in these observed event rates was low. The highest predicted event rates ranged from 11.0% for in-hospital mortality to 75.1% for the composite of mortality or high symptom burden 1 year after TAVR. CONCLUSION: No high-risk TAVR group in currently available TAVR CPMs had an appropriate event rate and adequate statistical power to meet a quantitative definition of futility.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...