Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1024-1034, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37227345

RESUMO

BACKGROUND: Early postoperative cognitive dysfunction (POCD) has been reported following atrial fibrillation (AF) ablation. However, whether POCD is persistent long-term is unknown. OBJECTIVES: The purpose of this study was to determine if AF catheter ablation is associated with persistent cognitive dysfunction at 12-month follow-up. METHODS: This is a prospective study of 100 patients with symptomatic AF who failed at least 1 antiarrhythmic drug randomized to either ongoing medical therapy or AF catheter ablation and followed up for 12 months. Changes in cognitive performance were assessed using 6 cognitive tests administered at baseline and during follow-up (3, 6, and 12 months). RESULTS: A total of 96 participants completed the study protocol. Mean age was 59 ± 12 years (32% women, 46% with persistent AF). The prevalence of new cognitive dysfunction in the ablation arm compared with the medical arm was as follows: at 3 months: 14% vs 2%; P = 0.03; at 6 months: 4% vs 2%; P = NS; and at 12 months: 0% vs 2%; P = NS. Ablation time was an independent predictor of POCD (P = 0.03). A significant improvement in cognitive scores was seen in 14% of the ablation arm patients at 12 months compared with no patients in the medical arm (P = 0.007). CONCLUSIONS: POCD was observed following AF ablation. However, this was transient with complete recovery at 12-month follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Disfunção Cognitiva , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/complicações , Estudos Prospectivos , Cognição , Disfunção Cognitiva/epidemiologia , Disfunção Cognitiva/etiologia , Ablação por Cateter/efeitos adversos
2.
Chemosphere ; 153: 521-7, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27037659

RESUMO

In this study, the formation of eight N-nitrosamines, N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine, N-nitrosomethylamine, N-nitrosodi-n-propylamine, N-nitrosodi-n-butylamine, N-Nitrosopiperidine, N-Nitrosopyrrolidine, N-Nitrosomorpholine, were systematically evaluated with respect to seven N-nitrosamine precursors (dimethylamine, trimethylamine, 3-(dimethylaminomethyl)indole, 4-dimethylaminoantipyrine, ethylmethylamine, diethylamine, dipropylamine) and three disinfectants (monochloramine, free chlorine, peracetic acid) under variable dosages, exposure times, and pH in a drinking water system. Without the presence of the seven selected N-nitrosamine precursors N-nitrosamine formation was not observed under any tested condition except very low levels of N-Nitrosopyrrolidine under some conditions. With selected N-nitrosamine precursors present N-nitrosamines formed at different levels under different conditions. The highest N-nitrosamine formation was NDMA with a maximum concentration of 1180 ng/L by monochloramine disinfection with precursors present; much lower levels of N-nitrosamines were formed by free chlorine disinfection; and no detectable level of N-nitrosamines were observed by peracetic acid disinfection except low level of N-Nitrosodi-n-propylamine under some conditions. NDMA formation was not affected by pH while four other N-nitrosamine formations were slightly affected by sample pH tested between 7 and 9, with formation decreasing with increasing pH. Monochloramine exposure time study displayed fast formation of N-nitrosamines, largely formed in four hours of exposure and maximized after seven days. This was a systematic study on the N-nitrosamine formation with the seven major N-nitrosamine precursors presence and absence under different conditions, including peracetic acid disinfection which has not been studied elsewhere.


Assuntos
Cloraminas/química , Cloro/química , Desinfetantes/química , Água Potável/química , Nitrosaminas/síntese química , Ácido Peracético/química , Poluentes Químicos da Água/química , Purificação da Água/métodos , Dimetilnitrosamina/síntese química , Desinfecção , Nitrosaminas/química
3.
Environ Sci Pollut Res Int ; 22(11): 8594-602, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25561263

RESUMO

Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 µg/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.


Assuntos
Bromatos/análise , Água Potável/química , Percloratos/análise , Poluentes Químicos da Água/análise , Purificação da Água/métodos , Adsorção , Bromatos/isolamento & purificação , Cromatografia por Troca Iônica/métodos , Monitoramento Ambiental/métodos , Monitoramento Ambiental/estatística & dados numéricos , Missouri , Espectrometria de Massas em Tandem/métodos , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...