Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mil Med ; 168(7): 528-9, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12901460

RESUMO

Patients are referred to the endodontist to have root canal therapy performed to treat pulpal and periradicular diseases. Routinely, the only radiograph to accompany the patient is the periapical radiograph. This radiograph is inadequate in the detection of asymptomatic pathosis that may be present in other areas of the maxilla and mandible. The military's readiness mission requires that a panoramic radiograph be part of the patient's dental record. In addition to its use for personal identification purposes, the panoramic radiograph is an excellent diagnostic tool that can give the clinician an overall view of the dentoalveolar structures. This retrospective study evaluated randomly selected panoramic radiographs and recorded the presence of radiolucent and radiopaque areas not evident on a referral periapical radiograph. The results of this study found a 4.2% occurrence of undiagnosed pathosis following additional radiographs and clinical examinations.


Assuntos
Endodontia/estatística & dados numéricos , Odontologia Militar/estatística & dados numéricos , Padrões de Prática Odontológica/estatística & dados numéricos , Radiografia Panorâmica/estatística & dados numéricos , Georgia , Humanos , Militares/estatística & dados numéricos , Seleção de Pacientes , Radiografia Panorâmica/instrumentação , Encaminhamento e Consulta/estatística & dados numéricos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Inquéritos e Questionários
2.
J Endod ; 29(3): 187-90, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12669878

RESUMO

The purpose of this study was to evaluate the antimicrobial activity of several medication preparations in root canal dentin infected with Enterococcus faecalis. Roots of extracted bovine incisors were prepared to standardized cylindrical test specimens, 5 mm in height. The smear layer was removed and the samples were autoclaved and then incubated at 37 degrees C/5% CO2 for 24 h in brain-heart infusion (BHI) broth containing 7.0 x 10(4) colony forming units per ml of E. faecalis. The samples were washed in phosphate buffered saline and mounted to individual culture wells with sticky wax. Test medications were applied to fill the canal lumina; medication groups were: (a) sterile H2O (positive control); (b) a 10% mixture of 1.0 g Ca(OH)2 USP in 10 ml sterile H2O; (c) 10% Ca(OH)2 in 0.12% chlorhexidine gluconate (Peridex); (d) Peridex; and (e) uninoculated BHI (negative control). The samples were incubated at 37 degrees C/5% CO2 for 24 h. Dentin samples for quantitative microbiology were then obtained with consecutive sterile burs (ISO 029, 035, 042). All three experimental groups demonstrated significantly greater antimicrobial activity than the positive control (p < 0.001). Group 2 demonstrated significantly greater antimicrobial activity than Group 3 or Group 4 at all dentin depths (p < 0.05). These results suggest that 10% Ca(OH)2 may be more effective than Peridex or 10% Ca(OH)2 in Peridex for the elimination of E. faecalis from dentin tubules.


Assuntos
Anti-Infecciosos Locais/farmacologia , Clorexidina/análogos & derivados , Cavidade Pulpar/microbiologia , Dentina/microbiologia , Enterococcus faecalis/efeitos dos fármacos , Irrigantes do Canal Radicular/farmacologia , Animais , Hidróxido de Cálcio/administração & dosagem , Hidróxido de Cálcio/farmacologia , Bovinos , Clorexidina/administração & dosagem , Clorexidina/farmacologia , Contagem de Colônia Microbiana , Combinação de Medicamentos , Enterococcus faecalis/crescimento & desenvolvimento , Camada de Esfregaço , Água
3.
J Endod ; 28(9): 665-7, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12236312

RESUMO

The purpose of this study was to compare quantitatively the density of gutta-percha root canal fillings produced by cold lateral condensation with those produced by an ultrasonically energized spreader in a warm lateral condensation technique in artificial root canals. Thirty-degree simulated root canals in 30 transparent acrylic blocks were instrumented by using rotary files. The blocks were weighed. The canals were obturated with gutta-percha using cold lateral condensation without sealer and then weighed again. Two applications of warm lateral condensation were then performed on the same 30 canals using the UES. The blocks were weighed once more after each additional UES obturation treatment. The first heat application produced a 26.92% increase in weight over lateral condensation, and the second heat application produced an additional 5.95% increase. A one-way repeated measures ANOVA followed by the Tukey-Kramer test revealed that both applications of warm lateral condensation produced significant (p < 0.001) increases in weight. Results indicate that warm lateral condensation using a ultrasonically energized spreader results in denser gutta-percha fills by weight than cold lateral condensation.


Assuntos
Guta-Percha/química , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Resinas Acrílicas , Análise de Variância , Temperatura Baixa , Cavidade Pulpar/ultraestrutura , Desenho de Equipamento , Temperatura Alta , Humanos , Modelos Anatômicos , Obturação do Canal Radicular/instrumentação , Preparo de Canal Radicular/instrumentação , Estatística como Assunto , Propriedades de Superfície , Ultrassom
4.
J Endod ; 28(2): 59-61, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11833689

RESUMO

The purpose of this study was to quantitatively compare the sealing effectiveness of five restorative materials that were used to create an intracoronal double seal. Fifty-two extracted mandibular molars were randomly divided into five groups of 10 teeth, and one positive and one negative control tooth. The crowns were removed and the pulpal floor and canal orifices were sealed with 3 mm of one of the following materials: Amalgabond, C&B Metabond, One-Step Dentin Adhesive with AEliteflo composite, One-Step with Palfique composite, or intermediate restorative material (IRM). Each tooth was affixed to a fluid filtration device and the seal was evaluated at 0, 1, 7, 30, and 90 days. The results showed a significant (p = 0.0001) difference in leakage between the materials. At 7 days, IRM, AEliteflo, and Palfique leaked significantly more than Amalgabond or C&B Metabond. Amalgabond consistently produced the best seal of all the materials throughout the duration of the study.


Assuntos
Infiltração Dentária , Materiais Restauradores do Canal Radicular , Compostos de Bário , Bis-Fenol A-Glicidil Metacrilato , Compostos de Boro , Cimentos Dentários , Adesivos Dentinários , Humanos , Teste de Materiais , Metacrilatos , Metilmetacrilatos , Dente Molar , Dióxido de Silício , Estatísticas não Paramétricas , Cimento de Óxido de Zinco e Eugenol
5.
J Endod ; 28(1): 40-3, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11806648

RESUMO

A cochlear implant (CI) converts mechanical sound energy into electrical signals that can be delivered to the cochlear nerve of profoundly deaf patients. The purpose of this study was to investigate whether electromagnetic interference with the CI occurs during the operation of the electric pulp tester, apex locator, electrocautery unit, electrosurgery unit, or panoramic radiograph machine. A mastoidectomy and cochleostomy were performed on a cadaver, and a CI was implanted. The dental devices were used intraorally, and the implant's circuitry was tested after each trial. A second CI was implanted in a human skull, which was then exposed to 50 panoramic radiographs, testing the implant's circuitry after each exposure. The probability of damage to the CI by any of the devices was negligible, except for the electrosurgery unit operated at level 7, which destroyed the CI's circuitry. Therefore, although the other devices seem safe, it is recommended that the electrosurgery unit not be used on a CI patient.


Assuntos
Implantes Cocleares , Equipamentos Odontológicos , Cadáver , Cóclea/cirurgia , Implante Coclear , Intervalos de Confiança , Teste da Polpa Dentária/instrumentação , Eletricidade , Eletrocoagulação/instrumentação , Campos Eletromagnéticos , Eletrocirurgia/instrumentação , Desenho de Equipamento , Falha de Equipamento , Segurança de Equipamentos , Humanos , Processo Mastoide/cirurgia , Desenho de Prótese , Radiografia Panorâmica/instrumentação , Estatística como Assunto , Ápice Dentário/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...