1.
Anal Chem ; 73(7): 1495-501, 2001 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-11321300

RESUMO

HPLC/MS is a linear technique characterized by serial injection and analysis of individual samples. Parallel-format high-throughput screens for druglike properties present a significant analytical challenge. Analysis speed and system ruggedness are key requirements for bioanalysis of thousands of samples per day. The tasks involved in LC/MS analysis are readily divided into three areas, sample preparation/liquid handling, LC/MS method building/sample analysis, and data processing. Several automation and multitasking strategies were developed and implemented to minimize plating and liquid handling errors, reduce dead times within the analysis cycle, and allow for comprehensive review of data. Delivering multiple samples to multiple injectors allows the autosampler time to complete its wash cycles and aspirate the next set of samples while the previous set is being analyzed. A dual-column chromatography system provides column cycling and peak stacking and allows rapid throughput using conventional LC equipment. Collecting all data for a compound into a single file greatly reduces the number of data files collected, increases the speed of data collection, allows rugged and complete review of all data, and provides facile data management. The described systems have analyzed over 40 000 samples per month for two years and have the capacity for over 2000 samples per instrument per day.


Assuntos
Cromatografia Gasosa-Espectrometria de Massas/métodos , Fígado/metabolismo , Automação , Bioensaio , Cromatografia Gasosa-Espectrometria de Massas/instrumentação , Hepatócitos/metabolismo , Humanos
2.
Rapid Commun Mass Spectrom ; 14(21): 2074-9, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11085421

RESUMO

An automated flow injection analysis (FIA) mass spectrometry system (AutoScan) was developed to allow rapid unattended determination of optimal conditions during mass (ms) and tandem mass spectrometry (ms/ms) on new chemical entities (NCEs) arranged in 96-well plates. The 96-well plate is placed on the deck of a modified Gilson Multiprobe autosampler for injection into a PE Sciex API 2000 triple quadrupole mass spectrometer. A customized software interface is used to create the necessary scan experiments by associating each 96-well plate of NCEs to be scanned with an index file containing data on the identity of each analyte and its expected molecular weight. Analytes are injected four at a time into a custom injection manifold and conventional mass spectra are acquired in both polarities (+/-) using an alternating positive/negative Q1 scan function. The software determines the optimal polarity and definitive precursor ion for all analytes and uses the results to build the injection sequence for product ion scanning. The samples are automatically re-injected under MS/MS conditions, and product ion scans that loop among different collision energies are collected for each analyte. The resulting data are processed automatically and the optimal MS/MS transitions for each analyte are selected. A color-coded graphical interface facilitates data review. Any unusual ion transitions or transposition errors made during plate preparation are noted and corrected. Complete MS and MS/MS conditions are obtained for 96 compounds in about one hour and the resulting data are available for download as sample control injection sequence files.


Assuntos
Espectrometria de Massas/instrumentação , Espectrometria de Massas/métodos , Automação/instrumentação , Automação/métodos , Cromatografia Líquida de Alta Pressão , Avaliação Pré-Clínica de Medicamentos , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/metabolismo , Software