Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
1.
Ann R Coll Surg Engl ; 101(6): 387-390, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31155894

RESUMO

BACKGROUND: Ankle fracture malreduction has been shown to result in poor long-term functional outcomes. Varying methods can be used to change practice and thereby outcomes. We present over four years' worth of results with the effects of different techniques for change. METHODS: Two audit cycles were performed incorporating three audit data collections; an initial standard setting audit in 2013, with re-audits in 2015 and 2017. Between the first and second audit was a period of education and reflection. Between the second and third audit there was a change in process in ankle fracture management supported by education. Image intensifier films were reviewed on the hospital picture archiving and communication system, by at least two blinded observers in each cycle. These were scored based on the criteria published by Pettrone et al. RESULTS: In the initial audit in 2013, there were 94 patients, with a malreduction rate of 33%. In the second audit in 2015, there were 68 patients, with an increase in malreduction rate to 43.8%. In the third audit in 2017, there were 205 patients, with a significant decrease in malreduction rate to 2.4%. The final major complication rate was 0.98%. The rate of deep infection was 0.5%. CONCLUSIONS: By recognising and addressing the need to improve the quality of ankle fracture fixation, we have made significant improvements in radiological outcomes. Education alone, without system change, was not successful in our department in achieving improved outcomes.


Assuntos
Fraturas do Tornozelo/cirurgia , Fixação de Fratura/métodos , Melhoria de Qualidade , Centros de Traumatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
2.
Bone Joint J ; 100-B(8): 1002-1009, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-30062940

RESUMO

Aims: The aim of this study was to report the initial results of the Exeter V40 stem, which became available in 2000. Patients and Methods: A total of 540 total hip arthroplasties (THAs) were performed in our unit using this stem between December 2000 and May 2002. Our routine protocol is to review patients postoperatively and at one, five, and ten years following surgery. Results: A total of 145 patients (26.9%) died before ten years and of the remaining 395 stems, 374 (94.7%) remain in situ. A total of 21 well-fixed stems (5.3%) were revised. Ten were exchanged using a cement-in-cement technique to facilitate acetabular revision. Three were revised for infection, one for instability, one for fracture of the stem, and six following a periprosthetic fracture. An additional 16 acetabular components (4.1%) were revised; five for aseptic loosening and 11 for instability. There were no revisions for aseptic loosening of the stem, and no evidence of aseptic loosening in any hip. The fate of every stem is known and all patients remain under review. Survivorship, with revision of the stem for aseptic loosening as the endpoint, was 100%. At 13.5 years, the Kaplan-Meier survival rate for all-cause revision of the stem was 96.8% (95% confidence interval (CI) 94.8 to 98.8) and all-cause revision (including acetabular revision, infection, and instability) was 91.2% (95% CI 88.3 to 94.1). Conclusion: Conclusion No stem was revised for aseptic loosening in this series. The contemporary Exeter V40 stem continues to perform well, and survival has remained comparable with that of the Exeter Universal stem. Cite this article: Bone Joint J 2018;100-B:1002-9.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adulto , Idoso , Cimentação , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Falha de Prótese/etiologia , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Recidiva , Reoperação/estatística & dados numéricos
3.
Bone Joint J ; 99-B(11): 1450-1457, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29092983

RESUMO

AIMS: We report the incidence of radiolucent lines (RLLs) using two flanged acetabular components at total hip arthroplasty (THA) and the effect of the Rim Cutter. PATIENTS AND METHODS: We performed a retrospective review of 300 hips in 292 patients who underwent primary cemented THA. A contemporary flanged acetabular component was used with (group 1) and without (group 2) the use of the Rim Cutter and the Rimfit acetabular component was used with the Rim Cutter (group 3). RLLs and clinical outcomes were evaluated immediately post-operatively and at five years post-operatively. RESULTS: There was no significant difference in the incidence of RLLs on the immediate post-operative radiographs (p = 0.241) or at five years post-operatively (p = 0.463). RLLs were seen on the immediate post-operative radiograph in 2% of hips in group 1, in 5% in group 2 and in 7% in group 3. Five years post-operatively, there were RLLs in 42% of hips in group 1, 41% in group 2 and in 49% in group 3. In the vast majority of hips, in each group, the RLL was present in DeLee and Charnley zone 1 only (86%, 83%, 67% respectively). Oxford and Harris Hip scores improved significantly in all groups. There was no significant difference in these scores or in the change in scores between the groups, with follow-up. CONCLUSION: Despite the Rim Cutter showing promising results in early laboratory and clinical studies, this analysis of the radiological and clinical outcome five years post-operatively does not show any advantage over and above modern cementing techniques in combination with a well performing cemented acetabular component. For this reason, we no longer use the Rim Cutter in routine primary THA. Cite this article: Bone Joint J 2017;99-B:1450-7.


Assuntos
Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Falha de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico por imagem , Radiografia , Estudos Retrospectivos , Resultado do Tratamento
4.
Injury ; 48(12): 2773-2777, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29031824

RESUMO

INTRODUCTION: The Exeter Trauma Stem (ETS) has been recommended by National Institute of Clinical Excellence (NICE) guidelines in the United Kingdom as a proven, cemented stem. A single laboratory study in the literature has raised possible concerns about the polished finish of the ETS and subsequent potential for accelerated loosening although there is little clinical evidence to support or refute this. METHODS: The aim of this study was to assess clinical outcomes of the ETS at a minimum of five years post implantation. Primary outcomes were radiological loosening at a minimum of five years along with survivorship of the implant. Patient demographics were prospectively collected and followed up. RESULTS: 218 ETS's (in 214 patients) were implanted from June 2002 until August 2008 in a single centre by a wide variety of surgeons of differing grades. Of these, 16 underwent revision surgery for fracture (2), dislocation (3), infection (1) and acetabular erosion (10) but there were no revisions for aseptic loosening of the implant. There were 64.0% (137/214) patients that had died by the time of this study. Of the remaining patients, 90 had radiographs of their hips at a minimum of 5 years with 36 of these at a minimum of 7 years post implantation. None of these had evidence of loosening. CONCLUSION: The ETS is a robust and suitable stem for implantation in patients with hip fractures. There are no clinical suspicions or increased rates of loosening with the ETS in our study. The concerns about surface finish are not borne out in our clinical study which shows no evidence of loosening at a minimum of five years post operation. It confers many advantages including ease of revision and it should continue to be used as per NICE guidelines.


Assuntos
Artroplastia de Quadril , Cimentação , Fraturas do Quadril/cirurgia , Prótese de Quadril , Radiografia , Reoperação/estatística & dados numéricos , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/estatística & dados numéricos , Cimentos Ósseos , Feminino , Seguimentos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Resultado do Tratamento , Reino Unido/epidemiologia
5.
Bone Joint J ; 98-B(12): 1611-1619, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27909122

RESUMO

AIMS: Femoral impaction bone grafting was first developed in 1987 using morselised cancellous bone graft impacted into the femoral canal in combination with a cemented, tapered, polished stem. We describe the evolution of this technique and instrumentation since that time. PATIENTS AND METHODS: Between 1987 and 2005, 705 revision total hip arthroplasties (56 bilateral) were performed with femoral impaction grafting using a cemented femoral stem. All surviving patients were prospectively followed for a mean of 14.7 years (9.8 to 28.3) with no loss to follow-up. By the time of the final review, 404 patients had died. RESULTS: There were 76 further revisions (10.8%) involving the stem; seven for aseptic loosening, 23 for periprosthetic fracture, 24 for infection, one for malposition, one for fracture of the stem and 19 cement-in-cement exchanges of the stem during acetabular revision. The 20-year survival rate for the entire series was 98.8% (95% confidence interval (CI) 97.8 to 99.8) with aseptic loosening as the endpoint, and 87.7% (95% CI 82.8 to 92.6) for revision for any reason. Survival improved with the evolution of the technique, although this was not statistically significant due to the overall low rate of further revision. CONCLUSION: This is the largest series of revision total hip arthroplasties with femoral impaction grafting, and the results support the continued use of this technique. Cite this article: Bone Joint J 2016;98-B:1611-19.


Assuntos
Artroplastia de Quadril/métodos , Transplante Ósseo/métodos , Fêmur/cirurgia , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Cimentação , Feminino , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Complicações Intraoperatórias , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/cirurgia , Desenho de Prótese , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Reoperação/efeitos adversos , Reoperação/métodos , Adulto Jovem
6.
Bone Joint J ; 98-B(11): 1441-1449, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27803218

RESUMO

AIMS: We present a minimum 20-year follow-up study of 382 cemented Exeter Universal total hip arthroplasties (350 patients) operated on at a mean age of 66.3 years (17 to 94). PATIENTS AND METHODS: All patients received the same design of femoral component, regardless of the original diagnosis. Previous surgery had been undertaken for 33 hips (8.6%). During the study period 218 patients with 236 hips (62%) died, 42 hips (11%) were revised and 110 hips (29%) in 96 patients were available for review. The acetabular components were varied and some designs are now obsolete, however they were all cemented. RESULTS: With an endpoint of revision for aseptic loosening or lysis, survivorship of the stem at 22.8 years was 99.0% (95% confidence interval (CI) 97.0 to 100). One stem was revised 21 years post-operatively in a patient with Gaucher's disease and proximal femoral osteolysis. Survivorship with aseptic loosening or lysis of the acetabular component or stem as the endpoint at 22.8 years was 89.3% (95% CI 84.8 to 93.8). With an endpoint of revision for any reason, overall survivorship was 82.9% (95% CI 77.4 to 88.4) at 22.8 years. Radiological review showed excellent preservation of bone stock at 20 to 25 years, and no impending failures of the stem. CONCLUSION: The Exeter femoral stem continues to perform well beyond 20 years. Cite this article: Bone Joint J 2016;98-B:1441-9.


Assuntos
Artroplastia de Quadril/instrumentação , Prótese de Quadril , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cimentos Ósseos , Cimentação , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Seguimentos , Doença de Gaucher/diagnóstico por imagem , Doença de Gaucher/cirurgia , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Osteólise/diagnóstico por imagem , Osteólise/cirurgia , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Índice de Gravidade de Doença , Adulto Jovem
7.
Bone Joint J ; 98-B(3): 307-12, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26920954

RESUMO

AIMS: We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). PATIENTS AND METHODS: A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. RESULTS: There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. Oxford and Harris hip scores demonstrated significant clinical improvement (all p < 0.001). Radiolucent lines were present in 37 (36%) of the 103 acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. CONCLUSION: Kaplan-Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. TAKE HOME MESSAGE: The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/instrumentação , Prótese de Quadril , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Cimentos Ósseos , Cimentação , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos
8.
Eur Spine J ; 25(1): 247-251, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25391625

RESUMO

PURPOSE: The purpose of this study was to validate the Oswestry Spinal Risk Index (OSRI) in an external population. The OSRI predicts survival in patients with metastatic spinal cord compression (MSCC). METHODS: We analysed the data of 100 patients undergoing surgical intervention for MSCC at a tertiary spinal unit and recorded the primary tumour pathology and Karnofsky performance status to calculate the OSRI. Logistic regression models and survival plots were applied to the data in accordance with the original paper. RESULTS: Lower OSRI scores predicted longer survival. The OSRI score predicted survival accurately in 74% of cases (p = 0.004). CONCLUSIONS: Our study has found that the OSRI is a significant predictor of survival at levels similar to those of the original authors and is a useful and simple tool in aiding complex decision making in patients presenting with MSCC.


Assuntos
Neoplasias da Mama/patologia , Tomada de Decisão Clínica/métodos , Técnicas de Apoio para a Decisão , Neoplasias Pulmonares/patologia , Compressão da Medula Espinal/etiologia , Neoplasias da Coluna Vertebral/mortalidade , Neoplasias da Coluna Vertebral/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Medição de Risco , Compressão da Medula Espinal/cirurgia , Neoplasias da Coluna Vertebral/complicações , Neoplasias da Coluna Vertebral/cirurgia
9.
Bone Joint J ; 97-B(8): 1070-5, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26224823

RESUMO

If patients could recall their physical status before total hip (THA) or knee arthroplasty (TKA) accurately it could have valuable applications both clinically and for research. This study evaluated the accuracy of a patient's recollection one year after either THA or TKA using the Oxford hip or knee scores (OHS and OKS). In total, 113 patients (59 THA, 54 TKA) who had completed the appropriate score pre-operatively were asked to complete the score again at a mean of 12.4 months (standard deviation (sd) 0.8) after surgery, recalling their pre-operative state. While there were no significant differences between the actual and recalled pre-operative scores (OHS mean difference 0.8, sd 6.21, 95% confidence interval (CI) -0.82 to 2.42, p = 0.329; OKS mean difference -0.11, sd 7.34, 95% CI -2.11 to 1.89, p = 0.912), absolute differences were relatively large (OHS, 5.24; OKS, 5.41), correlation was weak (OHS r = 0.7, OKS r = 0.61) and agreement between actual and recalled responses for individual questions was poor in half of the OHS and two thirds of the OKS. A patient's recollection of pre-operative pain and function is inaccurate one year after THA or TKA.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Avaliação da Deficiência , Rememoração Mental , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Indicadores Básicos de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Inquéritos e Questionários
10.
Bone Joint J ; 97-B(3): 346-52, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25737518

RESUMO

Flexor digitorum longus transfer and medial displacement calcaneal osteotomy is a well-recognised form of treatment for stage II posterior tibial tendon dysfunction. Although excellent short- and medium-term results have been reported, the long-term outcome is unknown. We reviewed the clinical outcome of 31 patients with a symptomatic flexible flat-foot deformity who underwent this procedure between 1994 and 1996. There were 21 women and ten men with a mean age of 54.3 years (42 to 70). The mean follow-up was 15.2 years (11.4 to 16.5). All scores improved significantly (p < 0.001). The mean American Orthopedic Foot and Ankle Society (AOFAS) score improved from 48.4 pre-operatively to 90.3 (54 to 100) at the final follow-up. The mean pain component improved from 12.3 to 35.2 (20 to 40). The mean function score improved from 35.2 to 45.6 (30 to 50). The mean visual analogue score for pain improved from 7.3 to 1.3 (0 to 6). The mean Short Form-36 physical component score was 40.6 (sd 8.9), and this showed a significant correlation with the mean AOFAS score (r = 0.68, p = 0.005). A total of 27 patients (87%) were pain free and functioning well at the final follow-up. We believe that flexor digitorum longus transfer and calcaneal osteotomy provides long-term pain relief and satisfactory function in the treatment of stage II posterior tibial tendon dysfunction.


Assuntos
Osteotomia/métodos , Disfunção do Tendão Tibial Posterior/cirurgia , Transferência Tendinosa/métodos , Adulto , Idoso , Calcâneo/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Disfunção do Tendão Tibial Posterior/fisiopatologia , Ossos do Tarso/cirurgia , Resultado do Tratamento
11.
Am J Transplant ; 15(3): 601-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25693472

RESUMO

Compensation models for physicians are currently based primarily on the work relative value unit (wRVU) that rewards productivity by work volume. The value-based payment structure soon to be ushered in by the Centers for Medicare and Medicaid Services rewards clinical quality and outcomes. This has prompted changes in wRVU value for certain services that will result in reduced payment for specialty procedures such as transplantation. To maintain a stable and competent workforce and achieve alignment between clinical activity, growth imperatives, and cost effectiveness, compensation of transplant physicians must evolve toward a matrix of measures beyond the procedure-based activity. This personal viewpoint proposes a redesign of transplant physician compensation plans to include the "virtual RVU" to recognize and reward meaningful clinical integration defined as hospital-physician commitment to specified and measurable metrics for current non-RVU-producing activities. Transplantation has been a leader in public outcomes reporting and is well suited to meet the challenges ahead that can only be overcome with a tight collaboration and alignment between surgeons, other physicians, support staff, and their respective institution and leadership.


Assuntos
Renda , Modelos Econômicos , Médicos/economia , Transplante , Centers for Medicare and Medicaid Services, U.S. , Humanos , Estados Unidos
12.
Bone Joint J ; 96-B(2): 188-94, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24493183

RESUMO

Impaction bone grafting for the reconstitution of bone stock in revision hip surgery has been used for nearly 30 years. Between 1995 and 2001 we used this technique in acetabular reconstruction, in combination with a cemented component, in 304 hips in 292 patients revised for aseptic loosening. The only additional supports used were stainless steel meshes placed against the medial wall or laterally around the acetabular rim to contain the graft. All Paprosky grades of defect were included. Clinical and radiographic outcomes were collected in surviving patients at a minimum of ten years after the index operation. Mean follow-up was 12.4 years (sd 1.5) (10.0 to 16.0). Kaplan-Meier survival with revision for aseptic loosening as the endpoint was 85.9% (95% CI 81.0 to 90.8) at 13.5 years. Clinical scores for pain relief remained satisfactory, and there was no difference in clinical scores between cups that appeared stable and those that appeared radiologically loose.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Cimentos Ósseos , Transplante Ósseo/métodos , Cabeça do Fêmur/transplante , Previsões , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação/métodos , Estudos Retrospectivos , Resultado do Tratamento
13.
Knee ; 20(6): 401-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23891167

RESUMO

BACKGROUND: Achieving soft tissue balance is an operative goal in total knee arthroplasty. This randomised, prospective study compared computer navigation to conventional techniques in achieving soft tissue balance. METHODS: Forty one consecutive knee arthroplasties were randomised to either a non-navigated or navigated group. In the non-navigated group, balancing was carried out using surgeon judgement. In the navigated group, balancing was carried out using navigation software. In both groups, the navigation software was used as a measuring tool. RESULTS: Balancing of the mediolateral extension gap was superior in the navigation group (p=0.001). No significant difference was found between the two groups in balancing the mediolateral flexion gap or in achieving equal flexion and extension gaps. CONCLUSIONS: Computer navigation offered little advantage over experienced surgeon judgement in achieving soft tissue balance in knee replacement. However, the method employed in the navigated group did provide a reproducible and objective assessment of flexion and extension gaps and may therefore benefit surgeons in training. LEVEL OF EVIDENCE: Level I, RCT.


Assuntos
Artroplastia do Joelho/métodos , Amplitude de Movimento Articular/fisiologia , Cirurgia Assistida por Computador/métodos , Idoso , Artroplastia do Joelho/efeitos adversos , Feminino , Seguimentos , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Prótese do Joelho , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Queensland , Radiografia , Medição de Risco , Lesões dos Tecidos Moles/prevenção & controle , Estatísticas não Paramétricas , Cirurgia Assistida por Computador/efeitos adversos , Resultado do Tratamento
14.
J Bone Joint Surg Br ; 94(11): 1482-6, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23109626

RESUMO

The technique of femoral cement-in-cement revision is well established, but there are no previous series reporting its use on the acetabular side at the time of revision total hip replacement. We describe the technique and report the outcome of 60 consecutive acetabular cement-in-cement revisions in 59 patients at a mean follow-up of 8.5 years (5 to 12). All had a radiologically and clinically well-fixed acetabular cement mantle at the time of revision. During the follow-up 29 patients died, but no hips were lost to follow-up. The two most common indications for acetabular revision were recurrent dislocation (46, 77%) and to complement femoral revision (12, 20%). Of the 60 hips, there were two cases of aseptic loosening of the acetabular component (3.3%) requiring re-revision. No other hip was clinically or radiologically loose (96.7%) at the latest follow-up. One hip was re-revised for infection, four for recurrent dislocation and one for disarticulation of a constrained component. At five years the Kaplan-Meier survival rate was 100% for aseptic loosening and 92.2% (95% CI 84.8 to 99.6), with revision for any cause as the endpoint. These results support the use of cement-in-cement revision on the acetabular side in appropriate cases. Theoretical advantages include preservation of bone stock, reduced operating time, reduced risk of complications and durable fixation.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Cimentos Ósseos/uso terapêutico , Articulação do Quadril/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Taxa de Sobrevida , Resultado do Tratamento
15.
Am J Transplant ; 12(10): 2623-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22823895

RESUMO

This personal viewpoint report summarizes the responses of a survey targeting established transplant programs with a structured framework, such as center, institute, or department, and stability of leadership to assure valuable experiential observations. The 18-item survey was sent to 20 US institutions that met inclusion criteria. The response rate was 100%. Seventeen institutions had a distinct transplant governance structure. A majority of respondents perceived that their type of transplant structure was associated with enhanced recognition within their institution (85%), improved regulatory compliance (85%), transplant volume growth (75%), improved quality outcomes (75%) and increased funding for transplant-related research (75%). The prevailing themes in respondents' remarks were the perceived need for autonomy of the transplant entity, alignment among services and finances and alignment of authority with responsibility. Many respondents suggested that a dialogue be opened about effective transplant infrastructure that overcomes the boundaries of traditional academic department silos.


Assuntos
Administração de Instituições de Saúde , Transplante , Modelos Organizacionais , Estados Unidos
16.
Foot Ankle Surg ; 18(1): 19-21, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22325998

RESUMO

BACKGROUND: This prospective study investigates the use of intraoperative fluoroscopy in hallux valgus surgery. To our knowledge there have been no studies questioning the benefit and reliability of intraoperative fluoroscopy in hallux valgus surgery. METHODS: We performed a prospective investigation of 28 consecutive cases undergoing hallux valgus surgery. Fluoroscopic images were examined intraoperatively and any significant findings documented. A comparison was made between these images and weight bearing films 6 weeks postoperatively to examine their reliability. We excluded those patients that went on to have an Akin osteotomy. RESULTS: There were no unforseen intraoperative events that were revealed by the use of fluoroscopy and no surgical modifications were made as a result of the intraoperative images. The intraoperative films were found to be a reliable representation of the postoperative weight bearing films but a small increase in the hallux valgus angle was noted at 6 weeks and this is thought to be due to stretching of the medial soft tissue repair. CONCLUSIONS: Intraoperative fluoroscopy is a reliable technique. This study was performed at a centre which performs approximately 100 hallux valgus operations per year and that should be taken into consideration when reviewing our findings. We conclude that there may be a role for fluoroscopy for surgeons in the early stages of the surgical learning curve and for those that infrequently perform hallux valgus surgery. We cannot, however, recommend that fluoroscopy be used routinely in hallux valgus surgery.


Assuntos
Fluoroscopia/métodos , Hallux Valgus/diagnóstico por imagem , Hallux Valgus/cirurgia , Articulação Metatarsofalângica/diagnóstico por imagem , Monitorização Intraoperatória/métodos , Procedimentos Ortopédicos/métodos , Seguimentos , Humanos , Articulação Metatarsofalângica/cirurgia , Estudos Prospectivos , Reprodutibilidade dos Testes
17.
Proc Inst Mech Eng H ; 224(9): 1133-40, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21053777

RESUMO

The Rim Cutter (Stryker Orthopedics, Mahwah, New Jersey) is a tool designed to cut a ledge inside the rim of the acetabulum, onto which a precisely trimmed, cemented, flanged cup can be fitted. The aim was to investigate the effect of the Rim Cutter on the intra-acetabular cement mantle pressure and the depth of cement penetration during cup insertion. The study had two parts. In the first part, hemi-pelvis models were fitted with pressure sensors. Pressure in the acetabulum was measured on insertion of a conventional cemented flanged cup with and without the use of a Rim Cutter to prepare the rim of the acetabulum. The second part assessed cement penetration when the same cups were inserted into a foam shell model. The shell was mounted in a jig and had holes drilled in it; the distance that cement penetrated into the holes was measured. A significant increase in cement pressure at the apex (p = 0.04) and the rim (p = 0.004) is seen when the Rim Cutter is used. Cement penetration in the Rim Cutter group was significantly increased at the rim of the acetabulum (p = 0.003). Insertion of a flanged cup after the acetabulum is prepared with the Rim Cutter leads to a significant increase in cement pressure and penetration during cup insertion in vitro when compared with conventional flanged cups.


Assuntos
Artroplastia de Quadril/instrumentação , Cimentos Ósseos , Prótese de Quadril , Engenharia Biomédica , Desenho de Equipamento , Articulação do Quadril/anatomia & histologia , Articulação do Quadril/cirurgia , Humanos , Técnicas In Vitro , Modelos Anatômicos , Pressão
18.
J Bone Joint Surg Br ; 92(10): 1351-5, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20884970

RESUMO

We report the outcome of the flangeless, cemented all-polyethylene Exeter acetabular component at a mean of 14.6 years (10 to 17) after operation. Of the 263 hips in 243 patients, 122 prostheses are still in situ; 112 patients (119 hips) have died, 18 hips have been revised, and three patients (four hips) were lost to follow-up. Radiographs at the final review were available for 110 of the 122 surviving hips. There were acetabular radiolucent lines in 54 hips (49%). Two acetabular components had migrated but neither patient required revision. The Kaplan-Meier survivorship at 15 years with 61 hips at risk with revision for any cause as the endpoint was 89.9% (95% confidence interval (CI) 84.6 to 95.2) and for aseptic loosening of the acetabular component or lysis 91.7% (95% CI 86.6 to 96.8). In 210 hips with a diagnosis of primary osteoarthritis, survivorship with revision for any cause as the endpoint was 93.2% (95% CI 88.1 to 98.3), and for aseptic loosening of the acetabular component 95.0% (95% CI 90.3 to 99.7). The cemented all-polyethylene Exeter acetabular component has an excellent long-term survivorship.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Acetábulo/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Polietileno , Desenho de Prótese , Falha de Prótese , Radiografia , Reoperação , Análise de Sobrevida , Resultado do Tratamento , Adulto Jovem
19.
J Bone Joint Surg Br ; 91(7): 851-4, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19567845

RESUMO

Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.


Assuntos
Artroplastia de Quadril/efeitos adversos , Cimentação/efeitos adversos , Articulação do Quadril/cirurgia , Artroplastia de Quadril/mortalidade , Cimentação/instrumentação , Cimentação/mortalidade , Ensaios Clínicos como Assunto , Feminino , Humanos , Masculino , Medição de Risco , Resultado do Tratamento , Reino Unido
20.
J Bone Joint Surg Br ; 91(5): 577-82, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19407288

RESUMO

The removal of well-fixed bone cement from the femoral canal during revision of a total hip replacement (THR) can be difficult and risks the loss of excessive bone stock and perforation or fracture of the femoral shaft. Retaining the cement mantle is attractive, yet the technique of cement-in-cement revision is not widely practised. We have used this procedure at our hospital since 1989. The stems were removed to gain a better exposure for acetabular revision, to alter version or leg length, or for component incompatibility. We studied 136 hips in 134 patients and followed them up for a mean of eight years (5 to 15). A further revision was required in 35 hips (25.7%), for acetabular loosening in 26 (19.1%), sepsis in four, instability in three, femoral fracture in one and stem fracture in one. No femoral stem needed to be re-revised for aseptic loosening. A cement-in-cement revision of the femoral stem is a reliable technique in the medium term. It also reduces the risk of perforation or fracture of the femoral shaft.


Assuntos
Artroplastia de Quadril/métodos , Cimentos Ósseos/uso terapêutico , Cimentação/métodos , Prótese de Quadril , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Fêmur/cirurgia , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Radiografia , Reoperação/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...