Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1029-1030: 48-59, 2016 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-27423043

RESUMO

Fluoroquinolones are considered as gold standard for the prevention of bacterial infections after transrectal ultrasound guided prostate biopsy. However, recent studies reported that fluoroquinolone- resistant bacterial strains are responsible for gradually increasing number of infections after transrectal prostate biopsy. In daily clinical practice, antibacterial efficacy is evaluated only in vitro, by measuring the reaction of bacteria with an antimicrobial agent in culture media (i.e. calculation of minimal inhibitory concentration). Such approach, however, has no relation to the treated tissue characteristics and might be highly misleading. Thus, the objective of this study was to develop, with the use of Design of Experiments approach, a reliable, specific and sensitive ultra-high performance liquid chromatography- diode array detection method for the quantitative analysis of levofloxacin in plasma and prostate tissue samples obtained from patients undergoing prostate biopsy. Moreover, correlation study between concentrations observed in plasma samples vs prostatic tissue samples was performed, resulting in better understanding, evaluation and optimization of the fluoroquinolone-based antimicrobial prophylaxis during transrectal ultrasound guided prostate biopsy. Box-Behnken design was employed to optimize chromatographic conditions of the isocratic elution program in order to obtain desirable retention time, peak symmetry and resolution of levofloxacine and ciprofloxacine (internal standard) peaks. Fractional Factorial design 2(4-1) with four center points was used for screening of significant factors affecting levofloxacin extraction from the prostatic tissue. Due to the limited number of tissue samples the prostatic sample preparation procedure was further optimized using Central Composite design. Design of Experiments approach was also utilized for evaluation of parameter robustness. The method was found linear over the range of 0.030-10µg/mL for human plasma and 0.300-30µg/g for human prostate tissue samples. The intra-day and inter-day variability for levofloxacine from both plasma and prostate samples were less than 10%, with accuracies between 93 and 108% of the nominal values. The limit of detection and the limit of quantification for human plasma were 0.01µg/mL and 0.03µg/mL, respectively. For the prostate tissue, the limit of detection and the limit of quantification were 0.1µg/g and 0.3µg/g, respectively. The average recoveries of levofloxacin were in the range from 99 to 106%. Also, the method fulfills requirements of robustness what was determined and proved by Design of Experiments. The developed method was successfully applied to examine prostate tissue and plasma samples from 140 hospitalized patients enrolled into the clinical study, 12h after oral administration of LVF at a dose of 500mg. The mean (±SD) LVF concentration in prostate was 6.22±3.52µg/g and in plasma 2.54±1.14µg/mL. Due to simplicity of the method and relative small amount of sample needed for the assay, the method can be applied in clinical practice for monitoring of LVF concentrations in plasma and prostate gland.


Assuntos
Antibacterianos/farmacocinética , Infecções Bacterianas/prevenção & controle , Cromatografia Líquida de Alta Pressão/métodos , Levofloxacino/farmacocinética , Próstata/patologia , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/sangue , Infecções Bacterianas/etiologia , Endossonografia/efeitos adversos , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Levofloxacino/sangue , Limite de Detecção , Masculino , Pessoa de Meia-Idade , Próstata/metabolismo , Próstata/microbiologia
2.
J Pharm Biomed Anal ; 94: 180-7, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24598171

RESUMO

Convenient methods for testing drug candidates' lipophilicity and acidity are highly requested in modern pharmaceutical research and drug development strategies. Reversed-phase high-performance liquid chromatography (RP HPLC) might be particularly useful for the determination of both dissociation constant and the (pH-dependent) partition coefficient related parameters, applicable in high-throughput analysis of multi-component mixtures. The general theory of combined pH/organic modifier gradient has recently provided equations relating gradient retention time and pH of the mobile phase. The purpose of this work was to facilitate the identification of analytes in this technique by its transfer to RP HPLC coupled with time-of-flight mass spectrometry with electrospray ionization source (ESI-TOF-MS). The accuracy of the proposed methodology was assessed by analyzing a set of known drugs. The ammonium formate, ammonium acetate or ammonium bicarbonate buffers were used to control pH during chromatographic analysis. In result, the pKa and hydrophobicity parameters were determined and the accuracy of the estimated values was assessed by comparing them with literature data. The gradient RP HPLC coupled with ESI-TOF-MS methods allowed for the rapid determination of dissociation constant and hydrophobicity and was shown to be especially applicable for complex mixtures. The use of ESI-TOF-MS detection allowed to achieve the medium-throughput screening rate (100 compounds/day) and provided a simple approach to assess pharmacokinetically important physicochemical properties of drugs.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas/métodos , Preparações Farmacêuticas/química , Soluções Tampão , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Força Próton-Motriz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...