Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
NMR Biomed ; 37(1): e5038, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37712359

RESUMO

The arterial input function (AIF) plays a crucial role in estimating quantitative perfusion properties from dynamic susceptibility contrast (DSC) MRI. An important issue, however, is that measuring the AIF in absolute contrast-agent concentrations is challenging, due to uncertainty in relation to the measured R 2 ∗ -weighted signal, signal depletion at high concentration, and partial-volume effects. A potential solution could be to derive the AIF from separately acquired dynamic contrast enhanced (DCE) MRI data. We aim to compare the AIF determined from DCE MRI with the AIF from DSC MRI, and estimated perfusion coefficients derived from DSC data using a DCE-driven AIF with perfusion coefficients determined using a DSC-based AIF. AIFs were manually selected in branches of the middle cerebral artery (MCA) in both DCE and DSC data in each patient. In addition, a semi-automatic AIF-selection algorithm was applied to the DSC data. The amplitude and full width at half-maximum of the AIFs were compared statistically using the Wilcoxon rank-sum test, applying a 0.05 significance level. Cerebral blood flow (CBF) was derived with different AIF approaches and compared further. The results showed that the AIFs extracted from DSC scans yielded highly variable peaks across arteries within the same patient. The semi-automatic DSC-AIF had significantly narrower width compared with the manual AIFs, and a significantly larger peak than the manual DSC-AIF. Additionally, the DCE-based AIF provided a more stable measurement of relative CBF and absolute CBF values estimated with DCE-AIFs that were compatible with previously reported values. In conclusion, DCE-based AIFs were reproduced significantly better across vessels, showed more realistic profiles, and delivered more stable and reasonable CBF measurements. The DCE-AIF can, therefore, be considered as an alternative AIF source for quantitative perfusion estimations in DSC MRI.


Assuntos
Artérias , Meios de Contraste , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Algoritmos , Perfusão
2.
Eur Radiol ; 33(7): 4767-4779, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36826502

RESUMO

OBJECTIVES: Follow-up of congenital lung abnormalities (CLA) is currently done with chest computer tomography (CT). Major disadvantages of CT are exposure to ionizing radiation and need for contrast enhancement to visualise vascularisation. Chest magnetic resonance imaging (MRI) could be a safe alternative to image CLA without using contrast agents. The objective of this cohort study was to develop a non-contrast MRI protocol for the follow-up of paediatric CLA patients, and to compare findings on MRI to postnatal CT in school age CLA patients. METHODS: Twenty-one CLA patients, 4 after surgical resection and 17 unoperated (mean age 12.8 (range 9.4-15.9) years), underwent spirometry and chest MRI. MRI was compared to postnatal CT on appearance and size of the lesion, and lesion associated abnormalities, such as hyperinflation and atelectasis. RESULTS: By comparing school-age chest MRI to postnatal CT, radiological appearance and diagnostic interpretation of the type of lesion changed in 7 (41%) of the 17 unoperated patients. In unoperated patients, the relative size of the lesion in relation to the total lung volume remained stable (0.9% (range - 6.2 to + 6.7%), p = 0.3) and the relative size of lesion-associated parenchymal abnormalities decreased (- 2.2% (range - 0.8 to + 2.8%), p = 0.005). CONCLUSION: Non-contrast-enhanced chest MRI was able to identify all CLA-related lung abnormalities. Changes in radiological appearance between MRI and CT were related to CLA changes, patients' growth, and differences between imaging modalities. Further validation is needed for MRI to be introduced as a safe imaging method for the follow-up of paediatric CLA patients. KEY POINTS: • Non-contrast-enhanced chest MRI is able to identify anatomical lung changes related to congenital lung abnormalities, including vascularisation. • At long-term follow-up, the average size of congenital lung abnormalities in relation to normal lung volume remains stable. • At long-term follow-up, the average size of congenital lung abnormalities associated parenchymal abnormalities such as atelectasis in relation to normal lung volume decreases.


Assuntos
Bivalves , Atelectasia Pulmonar , Humanos , Criança , Animais , Adolescente , Estudos de Coortes , Tomografia Computadorizada por Raios X/métodos , Pulmão/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética
3.
J Thorac Imaging ; 38(2): 97-103, 2023 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35482025

RESUMO

PURPOSE: To test respiratory-triggered ultrashort echo-time (UTE) Spiral VIBE-MRI sequence in systemic sclerosis-interstitial lung disease assessment compared with computed tomography (CT). MATERIAL AND METHODS: Fifty four SSc patients underwent chest CT and UTE (1.5 T). Two radiologists, independently and in consensus, verified ILD presence/absence and performed a semiquantitative analysis (sQA) of ILD, ground-glass opacities (GGO), reticulations and honeycombing (HC) extents on both scans. A CT software quantitative texture analysis (QA) was also performed. For ILD detection, intra-/inter-reader agreements were computed with Cohen K coefficient. UTE sensitivity and specificity were assessed. For extent assessments, intra-/inter-reader agreements and UTE performance against CT were computed by Lin's concordance coefficient (CCC). RESULTS: Three UTE were discarded for low quality, 51 subjects were included in the study. Of them, 42 QA segmentations were accepted. ILD was diagnosed in 39/51 CT. UTE intra-/inter-reader K in ILD diagnosis were 0.56 and 0.26. UTE showed 92.8% sensitivity and 75.0% specificity. ILD, GGO, and reticulation extents were 14.8%, 7.7%, and 7.1% on CT sQA and 13.0%, 11.2%, and 1.6% on CT QA. HC was <1% and not further considered. UTE intra-/inter-reader CCC were 0.92 and 0.89 for ILD extent and 0.84 and 0.79 for GGO extent. UTE RET extent intra-/inter-reader CCC were 0.22 and 0.18. UTE ILD and GGO extents CCC against CT sQA and QA were ≥0.93 and ≥0.88, respectively. RET extent CCC were 0.35 and 0.22 against sQA and QA, respectively. CONCLUSION: UTE Spiral VIBE-MRI sequence is reliable in assessing ILD and GGO extents in systemic sclerosis-interstitial lung disease patients.


Assuntos
Doenças Pulmonares Intersticiais , Escleroderma Sistêmico , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Sensibilidade e Especificidade , Pulmão
4.
J Magn Reson Imaging ; 57(6): 1908-1921, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36218321

RESUMO

BACKGROUND: Free-breathing 1 H ventilation MRI shows promise but only single-center validation has yet been performed against methods which directly image lung ventilation in patients with cystic fibrosis (CF). PURPOSE: To investigate the relationship between 129 Xe and 1 H ventilation images using data acquired at two centers. STUDY TYPE: Sequence comparison. POPULATION: Center 1; 24 patients with CF (12 female) aged 9-47 years. Center 2; 7 patients with CF (6 female) aged 13-18 years, and 6 healthy controls (6 female) aged 21-31 years. Data were acquired in different patients at each center. FIELD STRENGTH/SEQUENCE: 1.5 T, 3D steady-state free precession and 2D spoiled gradient echo. ASSESSMENT: Subjects were scanned with 129 Xe ventilation and 1 H free-breathing MRI and performed pulmonary function tests. Ventilation defect percent (VDP) was calculated using linear binning and images were visually assessed by H.M., L.J.S., and G.J.C. (10, 5, and 8 years' experience). STATISTICAL TESTS: Correlations and linear regression analyses were performed between 129 Xe VDP, 1 H VDP, FEV1 , and LCI. Bland-Altman analysis of 129 Xe VDP and 1 H VDP was carried out. Differences in metrics were assessed using one-way ANOVA or Kruskal-Wallis tests. RESULTS: 129 Xe VDP and 1 H VDP correlated strongly with; each other (r = 0.84), FEV1 z-score (129 Xe VDP r = -0.83, 1 H VDP r = -0.80), and LCI (129 Xe VDP r = 0.91, 1 H VDP r = 0.82). Bland-Altman analysis of 129 Xe VDP and 1 H VDP from both centers had a bias of 0.07% and limits of agreement of -16.1% and 16.2%. Linear regression relationships of VDP with FEV1 were not significantly different between 129 Xe and 1 H VDP (P = 0.08), while 129 Xe VDP had a stronger relationship with LCI than 1 H VDP. DATA CONCLUSION: 1 H ventilation MRI shows large-scale agreement with 129 Xe ventilation MRI in CF patients with established lung disease but may be less sensitive to subtle ventilation changes in patients with early-stage lung disease. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 2.


Assuntos
Fibrose Cística , Humanos , Feminino , Fibrose Cística/diagnóstico por imagem , Ventilação Pulmonar , Pulmão/diagnóstico por imagem , Respiração , Imageamento por Ressonância Magnética/métodos , Isótopos de Xenônio
5.
Pediatr Pulmonol ; 57(12): 2981-2991, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35982507

RESUMO

BACKGROUND AND OBJECTIVE: The most common respiratory complication of prematurity is bronchopulmonary dysplasia (BPD), leading to structural lung changes and impaired respiratory outcomes. However, also preterm children without BPD may show similar adverse respiratory outcomes. There is a need for a safe imaging modality for preterm children with and without BPD for disease severity assessment and risk stratification. Our objective was to develop a magnetic resonance imaging (MRI) protocol in preterm children with and without BPD at school age. METHODS: Nine healthy volunteers (median age 11.6 [range: 8.8-12.8] years), 11 preterm children with BPD (11.0 [7.2-15.6] years), and 9 without BPD (11.1 [10.7-12.6] years) underwent MRI. Images were scored on hypo- and hyperintense abnormalities, bronchopathy, and architectural distortion. MRI data were correlated to spirometry. Ventilation and perfusion defects were analyzed using Fourier Decomposition (FD) MRI. RESULTS: On MRI, children with BPD had higher %diseased lung (9.1 (interquartile range [IQR] 5.9-11.6)%) compared to preterm children without BPD (3.4 (IQR 2.5-5.4)%, p < 0.001) and healthy volunteers (0.4 (IQR 0.1-0.8)%, p < 0.001). %Diseased lung correlated negatively with %predicted FEV1 (r = -0.40, p = 0.04), FEV1 /FVC (r = -0.49, p = 0.009) and FEF75 (r = -0.63, p < 0.001). Ventilation and perfusion defects on FD sequence corresponded to hypointense regions on expiratory MRI. CONCLUSION: Chest MRI can identify structural and functional lung damage at school age in preterm children with and without BPD, showing a good correlation with spirometry. We propose MRI as a sensitive and safe imaging method (without ionizing radiation, contrast agents, or the use of anesthesia) for the long-term follow-up of preterm children.


Assuntos
Displasia Broncopulmonar , Recém-Nascido , Criança , Humanos , Displasia Broncopulmonar/diagnóstico por imagem , Volume Expiratório Forçado , Estudos de Viabilidade , Seguimentos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética
6.
J Physiol ; 600(17): 3931-3950, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35862359

RESUMO

Prematurely born young adults who experienced neonatal oxidative injury (NOI) of the lungs have increased incidence of cardiovascular disease. Here, we investigated the long-term effects of NOI on cardiopulmonary function in piglets at the age of 10-12 weeks. To induce NOI, term-born piglets (1.81 ± 0.06 kg) were exposed to hypoxia (10-12% F iO 2 ${F}_{{\rm{iO}}_{\rm{2}}}$ ), within 2 days after birth, and maintained for 4 weeks or until symptoms of heart failure developed (range 16-28 days), while SHAM piglets were normoxia raised. Following recovery (>5 weeks), NOI piglets were surgically instrumented to measure haemodynamics during hypoxic challenge testing (HCT) and exercise with modulation of the nitric-oxide system. During exercise, NOI piglets showed a normal increase in cardiac index, but an exaggerated increase in pulmonary artery pressure and a blunted increase in left atrial pressure - suggesting left atrial under-filling - consistent with an elevated pulmonary vascular resistance (PVR), which correlated with the duration of hypoxia exposure. Moreover, hypoxia duration correlated inversely with stroke volume (SV) during exercise. Nitric oxide synthase inhibition and HCT resulted in an exaggerated increase in PVR, while the PVR reduction by phosphodiesterase-5 inhibition was enhanced in NOI compared to SHAM piglets. Finally, within the NOI piglet group, prolonged duration of hypoxia was associated with a better maintenance of SV during HCT, likely due to the increase in RV mass. In conclusion, duration of neonatal hypoxia appears an important determinant of alterations in cardiopulmonary function that persist further into life. These changes encompass both pulmonary vascular and cardiac responses to hypoxia and exercise. KEY POINTS: Children who suffered from neonatal oxidative injury, such as very preterm born infants, have increased risk of cardiopulmonary disease later in life. Risk stratification requires knowledge of the mechanistic underpinning and the time course of progression into cardiopulmonary disease. Exercise and hypoxic challenge testing showed that 10- to 12-week-old swine that previously experienced neonatal oxidative injury had increased pulmonary vascular resistance and nitric oxide dependency. Duration of neonatal oxidative injury was a determinant of structural and functional cardiopulmonary remodelling later in life. Remodelling of the right ventricle, as a result of prolonged neonatal oxidative injury, resulted in worse performance during exercise, but enabled better performance during the hypoxic challenge test. Increased nitric oxide dependency together with age- or comorbidity-related endothelial dysfunction may contribute to predisposition to pulmonary hypertension later in life.


Assuntos
Hipertensão Pulmonar , Disfunção Ventricular Direita , Animais , Animais Recém-Nascidos , Humanos , Hipóxia , Pulmão/irrigação sanguínea , Óxido Nítrico , Estresse Oxidativo , Suínos , Disfunção Ventricular Direita/etiologia
7.
Neuroimage ; 245: 118752, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34823024

RESUMO

AIMS: Non-invasive measures of brain iron content would be of great benefit in neurodegeneration with brain iron accumulation (NBIA) to serve as a biomarker for disease progression and evaluation of iron chelation therapy. Although magnetic resonance imaging (MRI) provides several quantitative measures of brain iron content, none of these have been validated for patients with a severely increased cerebral iron burden. We aimed to validate R2* as a quantitative measure of brain iron content in aceruloplasminemia, the most severely iron-loaded NBIA phenotype. METHODS: Tissue samples from 50 gray- and white matter regions of a postmortem aceruloplasminemia brain and control subject were scanned at 1.5 T to obtain R2*, and biochemically analyzed with inductively coupled plasma mass spectrometry. For gray matter samples of the aceruloplasminemia brain, sample R2* values were compared with postmortem in situ MRI data that had been obtained from the same subject at 3 T - in situ R2*. Relationships between R2* and tissue iron concentration were determined by linear regression analyses. RESULTS: Median iron concentrations throughout the whole aceruloplasminemia brain were 10 to 15 times higher than in the control subject, and R2* was linearly associated with iron concentration. For gray matter samples of the aceruloplasminemia subject with an iron concentration up to 1000 mg/kg, 91% of variation in R2* could be explained by iron, and in situ R2* at 3 T and sample R2* at 1.5 T were highly correlated. For white matter regions of the aceruloplasminemia brain, 85% of variation in R2* could be explained by iron. CONCLUSIONS: R2* is highly sensitive to variations in iron concentration in the severely iron-loaded brain, and might be used as a non-invasive measure of brain iron content in aceruloplasminemia and potentially other NBIA disorders.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Ceruloplasmina/deficiência , Distúrbios do Metabolismo do Ferro/diagnóstico por imagem , Distúrbios do Metabolismo do Ferro/metabolismo , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Doenças Neurodegenerativas/diagnóstico por imagem , Doenças Neurodegenerativas/metabolismo , Autopsia , Ceruloplasmina/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Fenótipo
8.
Basic Res Cardiol ; 116(1): 51, 2021 09 12.
Artigo em Inglês | MEDLINE | ID: mdl-34510273

RESUMO

Pulmonary hypertension is common in heart failure with preserved ejection fraction (HFpEF). Here, we tested the hypothesis that comorbidities [diabetes mellitus (DM, streptozotocin), hypercholesterolemia (HC, high-fat diet) and chronic kidney disease (CKD, renal microembolization)] directly impair pulmonary vasomotor control in a DM + HC + CKD swine model. 6 months after induction of DM + HC + CKD, pulmonary arterial pressure was similar in chronically instrumented female DM + HC + CKD (n = 19) and Healthy swine (n = 18). However, cardiac output was lower both at rest and during exercise, implying an elevated pulmonary vascular resistance (PVR) in DM + HC + CKD swine (153 ± 10 vs. 122 ± 9 mmHg∙L-1∙min∙kg). Phosphodiesterase 5 inhibition and endothelin receptor antagonism decreased PVR in DM + HC + CKD (- 12 ± 12 and - 22 ± 7 mmHg∙L-1∙min∙kg) but not in Healthy swine (- 1 ± 12 and 2 ± 14 mmHg∙L-1∙min∙kg), indicating increased vasoconstrictor influences of phosphodiesterase 5 and endothelin. Inhibition of nitric oxide synthase produced pulmonary vasoconstriction that was similar in Healthy and DM + HC + CKD swine, but unmasked a pulmonary vasodilator effect of endothelin receptor antagonism in Healthy (- 56 ± 26 mmHg∙L-1∙min∙kg), whereas it failed to significantly decrease PVR in DM + HC + CKD, indicating loss of nitric oxide mediated inhibition of endothelin in DM + HC + CKD. Scavenging of reactive oxygen species (ROS) had no effect on PVR in either Healthy or DM + HC + CKD swine. Cardiovascular magnetic resonance imaging, under anesthesia, showed no right ventricular changes. Finally, despite an increased contribution of endogenous nitric oxide to vasomotor tone regulation in the systemic vasculature, systemic vascular resistance at rest was higher in DM + HC + CKD compared to Healthy swine (824 ± 41 vs. 698 ± 35 mmHg∙L-1∙min∙kg). ROS scavenging induced systemic vasodilation in DM + HC + CKD, but not Healthy swine. In conclusion, common comorbidities directly alter pulmonary vascular control, by enhanced PDE5 and endothelin-mediated vasoconstrictor influences, well before overt left ventricular backward failure or pulmonary hypertension develop.


Assuntos
Insuficiência Cardíaca , Animais , Antagonistas dos Receptores de Endotelina/farmacologia , Feminino , Óxido Nítrico , Volume Sistólico , Suínos , Vasoconstrição , Vasodilatadores
9.
Quant Imaging Med Surg ; 11(4): 1247-1255, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33816164

RESUMO

BACKGROUND: T2 mapping is increasingly used to quantify cartilage degeneration in knee osteoarthritis (OA), yet reproducibility studies in a multicenter setting are limited. The purpose of this study was to determine the longitudinal reproducibility and multicenter variation of cartilage T2 mapping, using various MRI equipment and acquisition protocols. METHODS: In this prospective multicenter study, four traveling, healthy human subjects underwent T2 mapping twice at five different centers with a 6-month-interval. Centers had various MRI scanners, field strengths, and T2 mapping acquisition protocols. Mean T2 values were calculated in six cartilage regions of interest (ROIs) as well as an average value per patient. A phantom was scanned once at each center. To evaluate longitudinal reproducibility, intraclass correlation coefficients (ICC), root-mean-square coefficient of variation (RMS-CV), and a Bland-Altman plot were used. To assess the variation of in vivo and phantom T2 values across centers, ANOVA was performed. RESULTS: ICCs of the T2 mapping measurements per ROI and the ROI's combined ranged from 0.73 to 0.91, indicating good to excellent longitudinal reproducibility. RMS-CVs ranged from 1.1% to 1.5% (per ROI) and 0.6% to 1.6% (ROIs combined) across the centers. A Bland-Altman plot did not reveal a systematic error. Evident, but consistent, discrepancies in T2 values were observed across centers, both in vivo and in the phantom. CONCLUSIONS: The results of this study suggest that T2 mapping can be used to longitudinal assess cartilage degeneration in multicenter studies. Given the differences in absolute cartilage T2 values across centers, absolute T2 values derived from various centers in multicenter multivendor trials should not be pooled.

10.
Laryngoscope ; 131(7): E2402-E2408, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33459361

RESUMO

OBJECTIVES/HYPOTHESIS: Dysphonia is a common problem at long-term follow-up after airway surgery for laryngotracheal stenosis (LTS) with major impact on quality of life. Dysphonia after LTS can be caused by scar tissue from initial stenosis along with anatomical alterations after surgery. There is need for a modality to noninvasively image structure and function of the reconstructed upper airways including the vocal cords to assess voice outcome and possible treatment after LTS. Our objective was to correlate vocal cord structure and function of patients after airway reconstruction for LTS on static and dynamic magnetic resonance imaging (MRI) to voice outcome. STUDY DESIGN: Prospective cohort study. METHODS: Voice outcome was assessed by voice questionnaires ((pediatric) Voice Handicap Index (p)VHI)) and the Dysphonia Severity Index (DSI). Postsurgical anatomy, airway lumen, and vocal cord thickness and movement on multiplanar static high-resolution MRI and dynamic acquisitions during phonation was correlated to voice outcome. RESULTS: Forty-eight patients (age 14.4 (range 7.5-30.7) years) and 11 healthy volunteers (15.9 (8.2-28.8) years) were included. Static MRI demonstrated vocal cord thickening in 80.9% of patients, correlated to a decrease in DSI (expected odds 0.75 [C.I. 0.58-0.96] P = .02). Dynamic MRI showed impaired vocal cord adduction during phonation in 61.7% of patients, associated with a lower DSI score (0.65 [C.I. 0.48-0.88] P = .006). CONCLUSIONS: In LTS patients, after airway reconstruction MRI can safely provide excellent structural and functional detail of the vocal cords correlating to DSI, with further usefulness expected from technical refinements. We therefore suggest MRI as a tool for extensive imaging during LTS follow-up. LEVEL OF EVIDENCE: 3 Laryngoscope, 131:E2402-E2408, 2021.


Assuntos
Assistência ao Convalescente/métodos , Disfonia/diagnóstico , Procedimentos de Cirurgia Plástica/efeitos adversos , Complicações Pós-Operatórias/diagnóstico , Prega Vocal/diagnóstico por imagem , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Disfonia/etiologia , Disfonia/fisiopatologia , Estudos de Viabilidade , Seguimentos , Voluntários Saudáveis , Humanos , Laringoestenose/cirurgia , Imageamento por Ressonância Magnética , Masculino , Fonação/fisiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Prega Vocal/fisiopatologia , Qualidade da Voz , Adulto Jovem
11.
Orphanet J Rare Dis ; 16(1): 21, 2021 01 07.
Artigo em Inglês | MEDLINE | ID: mdl-33413525

RESUMO

BACKGROUND: In Pompe disease, an inherited metabolic muscle disorder, severe diaphragmatic weakness often occurs. Enzyme replacement treatment is relatively ineffective for respiratory function, possibly because of irreversible damage to the diaphragm early in the disease course. Mildly impaired diaphragmatic function may not be recognized by spirometry, which is commonly used to study respiratory function. In this cross-sectional study, we aimed to identify early signs of diaphragmatic weakness in Pompe patients using chest MRI. METHODS: Pompe patients covering the spectrum of disease severity, and sex and age matched healthy controls were prospectively included and studied using spirometry-controlled sagittal MR images of both mid-hemidiaphragms during forced inspiration. The motions of the diaphragm and thoracic wall were evaluated by measuring thoracic cranial-caudal and anterior-posterior distance ratios between inspiration and expiration. The diaphragm shape was evaluated by measuring the height of the diaphragm curvature. We used multiple linear regression analysis to compare different groups. RESULTS: We included 22 Pompe patients with decreased spirometry results (forced vital capacity in supine position < 80% predicted); 13 Pompe patients with normal spirometry results (forced vital capacity in supine position ≥ 80% predicted) and 18 healthy controls. The mean cranial-caudal ratio was only 1.32 in patients with decreased spirometry results, 1.60 in patients with normal spirometry results and 1.72 in healthy controls (p < 0.001). Anterior-posterior ratios showed no significant differences. The mean height ratios of the diaphragm curvature were 1.41 in patients with decreased spirometry results, 1.08 in patients with normal spirometry results and 0.82 in healthy controls (p = 0.001), indicating an increased curvature of the diaphragm during inspiration in Pompe patients. CONCLUSIONS: Even in early-stage Pompe disease, when spirometry results are still within normal range, the motion of the diaphragm is already reduced and the shape is more curved during inspiration. MRI can be used to detect early signs of diaphragmatic weakness in patients with Pompe disease, which might help to select patients for early intervention to prevent possible irreversible damage to the diaphragm.


Assuntos
Doença de Depósito de Glicogênio Tipo II , Estudos Transversais , Doença de Depósito de Glicogênio Tipo II/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Espirometria , Capacidade Vital
12.
Eur Radiol ; 31(6): 3846-3855, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33219845

RESUMO

OBJECTIVES: The aim of this study was to assess the effect of a deep learning (DL)-based reconstruction algorithm on late gadolinium enhancement (LGE) image quality and to evaluate its influence on scar quantification. METHODS: Sixty patients (46 ± 17 years, 50% male) with suspected or known cardiomyopathy underwent CMR. Short-axis LGE images were reconstructed using the conventional reconstruction and a DL network (DLRecon) with tunable noise reduction (NR) levels from 0 to 100%. Image quality of standard LGE images and DLRecon images with 75% NR was scored using a 5-point scale (poor to excellent). In 30 patients with LGE, scar size was quantified using thresholding techniques with different standard deviations (SD) above remote myocardium, and using full width at half maximum (FWHM) technique in images with varying NR levels. RESULTS: DLRecon images were of higher quality than standard LGE images (subjective quality score 3.3 ± 0.5 vs. 3.6 ± 0.7, p < 0.001). Scar size increased with increasing NR levels using the SD methods. With 100% NR level, scar size increased 36%, 87%, and 138% using 2SD, 4SD, and 6SD quantification method, respectively, compared to standard LGE images (all p values < 0.001). However, with the FWHM method, no differences in scar size were found (p = 0.06). CONCLUSIONS: LGE image quality improved significantly using a DL-based reconstruction algorithm. However, this algorithm has an important impact on scar quantification depending on which quantification technique is used. The FWHM method is preferred because of its independency of NR. Clinicians should be aware of this impact on scar quantification, as DL-based reconstruction algorithms are being used. KEY POINTS: • The image quality based on (subjective) visual assessment and image sharpness of late gadolinium enhancement images improved significantly using a deep learning-based reconstruction algorithm that aims to reconstruct high signal-to-noise images using a denoising technique. • Special care should be taken when scar size is quantified using thresholding techniques with different standard deviations above remote myocardium because of the large impact of these advanced image enhancement algorithms. • The full width at half maximum method is recommended to quantify scar size when deep learning algorithms based on noise reduction are used, as this method is the least sensitive to the level of noise and showed the best agreement with visual late gadolinium enhancement assessment.


Assuntos
Aprendizado Profundo , Gadolínio , Algoritmos , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Imageamento por Ressonância Magnética , Masculino , Miocárdio/patologia
13.
Thorax ; 76(1): 44-52, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33122446

RESUMO

RATIONALE: Paediatric laryngotracheal stenosis (LTS) is often successfully corrected with open airway surgery. However, respiratory and vocal sequelae frequently remain. Clinical care and surgical interventions could be improved with better understanding of these sequelae. OBJECTIVE: The objective of this cross-sectional study was to develop an upper airway MRI protocol to obtain information on anatomical and functional sequelae post-LTS repair. METHODS: Forty-eight patients (age 14.4 (range 7.5-30.7) years) and 11 healthy volunteers (15.9 (8.2-28.8) years) were included. Spirometry and static and dynamic upper airway MRI (3.0 T, 30 min protocol) were conducted. Analysis included assessment of postoperative anatomy and airway lumen measurements during static and dynamic (inspiration and phonation) acquisitions. MAIN RESULTS: Good image quality without artefacts was achieved for static and dynamic images in the majority of MRIs. MRI showed vocal cord thickening in 80.9% of patients and compared with volunteers, a significant decrease in vocal cord lumen area (22.0 (IQR 17.7-30.3) mm2 vs 35.1 (21.2-54.7) mm2, p=0.03) but not cricoid lumen area (62.3±27.0 mm2 vs 66.2±34.8 mm2, p=0.70). Furthermore, 53.2% of patients had an A-frame deformation at site of previous tracheal cannula, showing lumen collapse during inspiration. Dynamic imaging showed incomplete vocal cord abduction during inspiration in 42.6% and incomplete adduction during phonation in 61.7% of patients. CONCLUSIONS: Static and dynamic MRI is an excellent modality to non-invasively image anatomy, tissue characteristics and vocal cord dynamics of the upper airways. MRI-derived knowledge on postsurgical LTS sequelae might be used to improve surgery.


Assuntos
Laringoestenose/diagnóstico , Laringe/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Traqueia/diagnóstico por imagem , Estenose Traqueal/diagnóstico , Prega Vocal/diagnóstico por imagem , Adolescente , Adulto , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Adulto Jovem
14.
J Cardiovasc Magn Reson ; 22(1): 68, 2020 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-32938483

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) phase contrast (PC) flow measurements suffer from phase offset errors. Background subtraction based on stationary phantom measurements can most reliably be used to overcome this inaccuracy. Stationary tissue correction is an alternative and does not require additional phantom scanning. The aim of this study was 1) to compare measurements with and without stationary tissue correction to phantom corrected measurements on different GE Healthcare CMR scanners using different software packages and 2) to evaluate the clinical implications of these methods. METHODS: CMR PC imaging of both the aortic and pulmonary artery flow was performed in patients on three different 1.5 T CMR scanners (GE Healthcare) using identical scan parameters. Uncorrected, first, second and third order stationary tissue corrected flow measurement were compared to phantom corrected flow measurements, our reference method, using Medis QFlow, Circle cvi42 and MASS software. The optimal (optimized) stationary tissue order was determined per scanner and software program. Velocity offsets, net flow, clinically significant difference (deviation > 10% net flow), and regurgitation severity were assessed. RESULTS: Data from 175 patients (28 (17-38) years) were included, of which 84% had congenital heart disease. First, second and third order and optimized stationary tissue correction did not improve the velocity offsets and net flow measurements. Uncorrected measurements resulted in the least clinically significant differences in net flow compared to phantom corrected data. Optimized stationary tissue correction per scanner and software program resulted in net flow differences (> 10%) in 19% (MASS) and 30% (Circle cvi42) of all measurements compared to 18% (MASS) and 23% (Circle cvi42) with no correction. Compared to phantom correction, regurgitation reclassification was the least common using uncorrected data. One CMR scanner performed worse and significant net flow differences of > 10% were present both with and without stationary tissue correction in more than 30% of all measurements. CONCLUSION: Phase offset errors had a significant impact on net flow quantification, regurgitation assessment and varied greatly between CMR scanners. Background phase correction using stationary tissue correction worsened accuracy compared to no correction on three GE Healthcare CMR scanners. Therefore, careful assessment of phase offset errors at each individual scanner is essential to determine whether routine use of phantom correction is necessary. TRIAL REGISTRATION: Observational Study.


Assuntos
Aorta/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Cardiopatias Congênitas/diagnóstico por imagem , Hemodinâmica , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética/instrumentação , Artéria Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Adolescente , Adulto , Aorta/fisiopatologia , Insuficiência da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Criança , Feminino , Cardiopatias Congênitas/fisiopatologia , Humanos , Masculino , Imagens de Fantasmas , Valor Preditivo dos Testes , Artéria Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/fisiopatologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Adulto Jovem
15.
Recent Results Cancer Res ; 216: 31-110, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32594384

RESUMO

Imaging in Oncology is rapidly moving from the detection and size measurement of a lesion to the quantitative assessment of metabolic processes and cellular and molecular interactions. Increasing insights into cancer as a complex disease with involvement of the tumor stroma in tumor pathobiological processes have made it clear that for successful control of cancer, treatment strategies should not only be directed at the cancer cells but should also take aspects of the tumor microenvironment into account. This requires an understanding of the complex molecular and cellular interactions in cancer tissue. Recent developments in imaging technology have increased the possibility to image various pathobiological processes in cancer development and response to treatment. For computed tomography (CT) and magnetic resonance imaging (MRI) various improvements in hardware, software, and imaging probes have lifted these modalities from classical anatomical imaging techniques to techniques suitable to image and quantify various physiological processes and molecular and cellular interactions. Next to a more general overview of possible imaging targets in oncology, this chapter provides an overview of the various developments in CT and MRI technology and some specific applications.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Humanos , Oncologia
16.
PLoS One ; 14(7): e0219291, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31310623

RESUMO

OBJECTIVES: Autopsy rates worldwide have dropped significantly over the last decades and imaging-based autopsies are increasingly used as an alternative to conventional autopsy. Our aim was to evaluate the clinical performance and cost of minimally invasive autopsy. METHODS: This study was part of a prospective cohort study evaluating a newly implemented minimally invasive autopsy consisting of MRI, CT, and biopsies. We calculated diagnostic yield and clinical utility-defined as the percentage successfully answered clinical questions-of minimally invasive autopsy. We performed minimally invasive autopsy in 46 deceased (30 men, 16 women; mean age 62.9±17.5, min-max: 18-91). RESULTS: Ninety-six major diagnoses were found with the minimally invasive autopsy of which 47/96 (49.0%) were new diagnoses. CT found 65/96 (67.7%) major diagnoses and MRI found 82/96 (85.4%) major diagnoses. Eighty-four clinical questions were asked in all cases. Seventy-one (84.5%) of these questions could be answered with minimally invasive autopsy. CT successfully answered 34/84 (40.5%) clinical questions; in 23/84 (27.4%) without the need for biopsies, and in 11/84 (13.0%) a biopsy was required. MRI successfully answered 60/84 (71.4%) clinical questions, in 27/84 (32.1%) without the need for biopsies, and in 33/84 (39.8%) a biopsy was required. The mean cost of a minimally invasive autopsy was €1296 including brain biopsies and €1087 without brain biopsies. Mean cost of CT was €187 and of MRI €284. CONCLUSIONS: A minimally invasive autopsy, consisting of CT, MRI and CT-guided biopsies, performs well in answering clinical questions and detecting major diagnoses. However, the diagnostic yield and clinical utility were quite low for postmortem CT and MRI as standalone modalities.


Assuntos
Autopsia/economia , Autopsia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Causas de Morte , Feminino , Hospitais , Humanos , Biópsia Guiada por Imagem/economia , Imageamento por Ressonância Magnética/economia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/economia , Adulto Jovem
17.
Int J Cardiovasc Imaging ; 35(6): 1111-1118, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30963352

RESUMO

The purpose of this study was to compare invasively measured aorta flow with 2D phase contrast flow and 4D flow measurements by cardiovascular magnetic resonance (CMR) imaging in a large animal model. Nine swine (mean weight 63 ± 4 kg) were included in the study. 4D flow CMR exams were performed on a 1.5T MRI scanner. Flow measurements were performed on 4D flow images at the aortic valve level, in the ascending aorta, and main pulmonary artery. Simultaneously, flow was measured using an invasive flow probe, placed around the ascending aorta. Additionally, standard 2D phase contrast flow and 2D left ventricular (LV) volumetric data were used for comparison. The correlations of cardiac output (CO) between the invasive flow probe, and CMR modalities were strong to very strong. CO measured by 4D flow CMR correlated better with the CO measured by the invasive flow probe than 2D flow CMR flow and volumetric LV data (4D flow CMR: Spearman's rho = 0.86 at the aortic valve level and 0.90 at the ascending aorta level; 2D flow CMR: 0.67 at aortic valve level; LV measurements: 0.77). In addition, there tended to be a correlation between mean pulmonary artery flow and aorta flow with 4D flow (Spearman's rho = 0.65, P = 0.07), which was absent in measurements obtained with 2D flow CMR (Spearman's rho = 0.40, P = 0.33). This study shows that aorta flow can be accurately measured by 4D flow CMR compared to simultaneously measured invasive flow. This helps to further validate the quantitative reliability of this technique.


Assuntos
Aorta/diagnóstico por imagem , Cateterismo Cardíaco , Hemodinâmica , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Artéria Pulmonar/diagnóstico por imagem , Circulação Pulmonar , Animais , Aorta/fisiologia , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Animais , Valor Preditivo dos Testes , Artéria Pulmonar/fisiologia , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Sus scrofa , Fatores de Tempo , Transdutores de Pressão
18.
Eur Radiol ; 29(6): 2770-2782, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30519932

RESUMO

OBJECTIVES: This study was conducted in order to evaluate the effect of geometric distortion (GD) on MRI lung volume quantification and evaluate available manual, semi-automated, and fully automated methods for lung segmentation. METHODS: A phantom was scanned with MRI and CT. GD was quantified as the difference in phantom's volume between MRI and CT, with CT as gold standard. Dice scores were used to measure overlap in shapes. Furthermore, 11 subjects from a prospective population-based cohort study each underwent four chest MRI acquisitions. The resulting 44 MRI scans with 2D and 3D Gradwarp were used to test five segmentation methods. Intraclass correlation coefficient, Bland-Altman plots, Wilcoxon, Mann-Whitney U, and paired t tests were used for statistics. RESULTS: Using phantoms, volume differences between CT and MRI varied according to MRI positions and 2D and 3D Gradwarp correction. With the phantom located at the isocenter, MRI overestimated the volume relative to CT by 5.56 ± 1.16 to 6.99 ± 0.22% with body and torso coils, respectively. Higher Dice scores and smaller intraobject differences were found for 3D Gradwarp MR images. In subjects, semi-automated and fully automated segmentation tools showed high agreement with manual segmentations (ICC = 0.971-0.993 for end-inspiratory scans; ICC = 0.992-0.995 for end-expiratory scans). Manual segmentation time per scan was approximately 3-4 h and 2-3 min for fully automated methods. CONCLUSIONS: Volume overestimation of MRI due to GD can be quantified. Semi-automated and fully automated segmentation methods allow accurate, reproducible, and fast lung volume quantification. Chest MRI can be a valid radiation-free imaging modality for lung segmentation and volume quantification in large cohort studies. KEY POINTS: • Geometric distortion varies according to MRI setting and patient positioning. • Automated segmentation methods allow fast and accurate lung volume quantification. • MRI is a valid radiation-free alternative to CT for quantitative data analysis.


Assuntos
Imageamento Tridimensional/métodos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Criança , Estudos de Coortes , Feminino , Humanos , Medidas de Volume Pulmonar/métodos , Masculino , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes
19.
Eur Respir Rev ; 27(150)2018 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30567932

RESUMO

Thin-slices multi-detector computed tomography (MDCT) plays a key role in the differential diagnosis of interstitial lung disease (ILD). However, thin-slices MDCT has a limited ability to detect active inflammation, which is an important target of newly developed ILD drug therapy. Magnetic resonance imaging (MRI), thanks to its multi-parameter capability, provides better tissue characterisation than thin-slices MDCT.Our aim was to summarise the current status of MRI applications in ILD and to propose an ILD-MRI protocol. A systematic literature search was conducted for relevant studies on chest MRI in patients with ILD.We retrieved 1246 papers of which 55 original papers were selected for the review. We identified 24 studies comparing image quality of thin-slices MDCT and MRI using several MRI sequences. These studies described new MRI sequences to assess ILD parenchymal abnormalities, such as honeycombing, reticulation and ground-glass opacity. Thin-slices MDCT remains superior to MRI for morphological imaging. However, recent studies with ultra-short echo-time MRI showed image quality comparable to thin-slices MDCT. Several studies demonstrated the added value of chest MRI by using functional imaging, especially to detect and quantify inflammatory changes.We concluded that chest MRI could play a role in ILD patients to differentiate inflammatory and fibrotic changes and to assess efficacy of new ILD drugs.


Assuntos
Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Pulmão/efeitos dos fármacos , Doenças Pulmonares Intersticiais/tratamento farmacológico , Masculino , Tomografia Computadorizada Multidetectores , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
20.
Eur Heart J Cardiovasc Imaging ; 19(7): 739-748, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29474537

RESUMO

Aims: The autopsy rate worldwide is alarmingly low (0-15%). Mortality statistics are important, and it is, therefore, essential to perform autopsies in a sufficient proportion of deaths. The imaging autopsy, non-invasive, or minimally invasive autopsy (MIA) can be used as an alternative to the conventional autopsy in an attempt to improve postmortem diagnostics by increasing the number of postmortem procedures. The aim of this study was to determine the diagnostic accuracy of postmortem magnetic resonance imaging (MRI), computed tomography (CT), and CT-guided biopsy for the detection of acute and chronic myocardial ischaemia. Methods and results: We included 100 consecutive adult patients who died in hospital, and for whom next-of-kin gave permission to perform both conventional autopsy and MIA. The MIA consists of unenhanced total-body MRI and CT followed by CT-guided biopsies. Conventional autopsy was used as reference standard. We calculated sensitivity and specificity and receiver operating characteristics curves for CT and MRI as the stand-alone test or combined with biopsy for detection of acute and chronic myocardial infarction (MI). Sensitivity and specificity of MRI with biopsies for acute MI was 0.97 and 0.95, respectively and 0.90 and 0.75, respectively for chronic MI. MRI without biopsies showed a high specificity (acute: 0.92; chronic: 1.00), but low sensitivity (acute: 0.50; chronic: 0.35). CT (total Agatston calcium score) had a good diagnostic value for chronic MI [area under curve (AUC) 0.74, 95% confidence interval (CI) 0.64-0.84], but not for acute MI (AUC 0.60, 95% CI 0.48-0.72). Conclusion: We found that the combination of MRI with biopsies had high sensitivity and specificity for the detection of acute and chronic myocardial ischaemia.


Assuntos
Autopsia/métodos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Centros Médicos Acadêmicos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Doença Crônica , Estudos Transversais , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/patologia , Variações Dependentes do Observador , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...