Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Oral Investig ; 28(2): 128, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38294555

RESUMO

OBJECTIVES: This in vitro study aimed to evaluate the wear of natural teeth opposing 3 mol% yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) with different surface conditions. MATERIALS AND METHODS: Sixty 3Y-TZP specimens were randomly assigned to six groups (n = 10), differing in surface condition. In three groups, the samples underwent glazing-with the glaze applied to roughened (i.e., 106-µm-grit diamond-finished), as-sintered, and polished zirconia. The three remaining groups consisted of unglazed specimens: solely polished samples and diamond-finished samples (106-µm-grit and 46-µm-grit) without further conditioning. Two-body wear was evaluated at extracted, non-carious molars (n = 60), which served as antagonists in chewing simulation (10,000 masticatory cycles, 49N load). As a control, natural teeth with intact enamel surfaces were tested against natural molars (n = 10). All samples were 3D-scanned before and after the chewing simulation (7 Series, Straumann). Volume loss was calculated (Inspect Software, GOM), and statistically analyzed (SPSS Statistics 24, IBM). RESULTS: Volume loss of the natural antagonists decreased in the following order: 106-µm-grit diamond-finished zirconia (4.6 ± 2.5 mm3), glazed 106-µm-grit diamond-finished zirconia (3.8 ± 1.1 mm3), glazed as-sintered zirconia (3.5 ± 0.9 mm3), 46-µm-grit diamond-finished zirconia (1.7 ± 0.6 mm3), control (1.6 ± 0.7 mm3), glazed polished zirconia (1.4 ± 0.5 mm3), and solely polishing (0.4 ± 0.2 mm3). Even when polishing the surfaces before glazing, volume loss was not mitigated to the same extent as after polishing alone. CONCLUSIONS: The zirconia surface condition beneath the glazing influences antagonist wear. Although polishing before glazing resulted in acceptable levels of antagonist wear, this approach did not yield as favorable results as polishing alone. CLINICAL RELEVANCE: For operators favoring glazing, pre-polishing the zirconia surface could be advantageous to reduce wear.


Assuntos
Esmalte Dentário , Boca Edêntula , Zircônio , Humanos , Simulação por Computador , Diamante , Mastigação
2.
Clin Oral Investig ; 27(5): 2089-2095, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37022527

RESUMO

OBJECTIVES: Orthodontic patients struggle with interdental cleaning calling for simpler mechanical devices to reduce the high plaque levels. The present study aimed to compare the cleansing efficacy of an oral irrigator with that of dental flossing in patients with fixed braces after 4 weeks of home-use. MATERIALS AND METHODS: The study design is a randomized and single-blinded cross-over study. After 28 days using the products at home, hygiene indices (Rustogi Modified Navy Plaque Index (RMNPI); gingival bleeding index (GBI)) were compared between test (oral irrigator) and control product (dental floss). RESULTS: Seventeen adult individuals finalized the study. After 28 days of cleaning with the oral irrigator, RMNPI was 54.96% (46.91-66.05) compared to 52.98% (42.75-65.60) with dental floss (p = 0.029). Subgroup analysis revealed that the higher cleansing efficacy of the dental floss is attributable to buccal and marginal areas. GBI after the test phase with the oral irrigator was 12.96% (7.14-24.31) and statistically significantly higher compared to 8.33% (5.84-15.33) with dental floss (p = 0.030) which could be seen in all subgroups. CONCLUSIONS: Oral irrigators do not remove plaque and reduce gingival bleeding as efficiently as dental floss in easily accessible regions. However, in posterior regions, where the patients struggled with the application of dental floss, the oral irrigator showed similar results. CLINICAL RELEVANCE: Oral irrigators should only be recommended to orthodontic patients who cannot use interdental brushes and are not compliant with dental flossing.


Assuntos
Placa Dentária , Gengivite , Adulto , Humanos , Dispositivos para o Cuidado Bucal Domiciliar , Estudos Cross-Over , Escovação Dentária , Gengivite/prevenção & controle , Higiene Bucal , Placa Dentária/prevenção & controle , Índice de Placa Dentária , Método Simples-Cego
3.
Clin Oral Investig ; 27(2): 603-611, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36272010

RESUMO

OBJECTIVES: To compare the cleansing efficacy of an auto-cleaning device with nylon bristles (Y-brush®) to that of manual toothbrushing. MATERIALS AND METHODS: Twenty probands refrained from oral hygiene for 3 days. Rustogi Modified Navy Plaque Index was assessed before and after (randomized) toothbrushing either with the auto-cleaning device for 5 s per jaw or with a manual toothbrush for a freely chosen time up to 4 min. The clinical investigation was repeated in a cross-over design. In a third trial period, the brushing time for auto-cleaning was increased to 15 s per jaw. The study was supplemented by plaster cast analyses. RESULTS: Full-mouth plaque reduction was higher with manual toothbrushing than with auto-cleaning for 5 s per jaw (p < 0.001). There was no statistically significant difference on smooth tooth surfaces but on marginal and interdental sites. Increasing the brushing time of auto-cleaning to 15 s per jaw resulted in a comparable full-mouth plaque reduction as with manual toothbrushing (p = 0.177). In 95% of individuals, the device was too short not completely covering second molars. In 30.67% of teeth, the gingival margin was not covered by bristles. CONCLUSIONS: Auto-cleaning devices with nylon bristles have a future potential to reach plaque reduction levels comparable to manual toothbrushing, although manufacturers must focus on improving an accurate fit. CLINICAL RELEVANCE: Under the premise of an ameliorated fit, the auto-cleaning device might be recommendable for people with low brushing efficacy. Interdental sites remain a failure point if adjunct interdental cleaning is not viable.


Assuntos
Gengivite , Dente , Humanos , Escovação Dentária , Nylons , Dispositivos para o Cuidado Bucal Domiciliar , Projetos Piloto , Índice de Placa Dentária , Método Simples-Cego , Desenho de Equipamento
4.
Artigo em Inglês | MEDLINE | ID: mdl-35162583

RESUMO

The aim of this systematic review was to answer the question of whether patients with osteogenesis imperfecta can be prosthetically rehabilitated with dental implants. A protocol was prospectively registered in PROSPERO (CRD42021286368). The inclusion criteria were the presence of osteogenesis imperfecta and the use of implants for prosthetic restorations. Cases in which the inclusion criteria were not met were excluded. PubMed, Web of Science, and Scopus were last searched on 22 August 2021. Quality assessment was performed using the Methodological Quality and Synthesis of Case Series and Case Reports tool. The primary outcome was implant survival. Supporting data were analyzed descriptively. Twelve studies were included. Twenty-three patients received a total number of 116 implants, with 5.0 (±3.8) implants placed per patient. The implant survival rate was 94.0% with a mean follow-up of 59.1 months (±36.1). A limitation of this review was the relatively short follow-up time in some of the included studies; therefore, the survival rate may be overestimated. Nevertheless, the available data showed the loss of only seven implants, with two implants lost due to implant fractures not attributable to the patient. With the limitations of this review and based on the available data, dental implants have a high survival rate in patients with osteogenesis imperfecta. Therefore, dental implants may be a viable treatment option for replacing missing teeth. This research was not funded by external resources.


Assuntos
Implantes Dentários , Osteogênese Imperfeita , Falha de Restauração Dentária , Humanos
5.
Healthcare (Basel) ; 9(3)2021 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-33807082

RESUMO

The aim of this study was to investigate the operating conditions of dentists in Central Europe during the first coronavirus disease 2019 (COVID-19) lockdown. A survey including 24 questions was emailed to dentists in Austria, Germany, Switzerland and South Tyrol (Italy). Questions regarding dentists' field of work, working hours, treatments performed, personal protective equipment and protocols, and economic consequences were asked. 1731 participants were included. 30.4% of participants worked mainly in Austria, 60.8% in Germany, 6% in Switzerland and 2.1% in South Tyrol. A country-specific analysis for the situation of South Tyrol was not possible due to the low participation; 53.7% of German, 45.5% of Austrian, and 11.7% of Swiss respondents reduced their working hours; 42.8% of Austrian, 41.5% of Swiss, and 17.3% of German participants closed their offices temporarily; 52.2% of respondents provided emergency service including pain management, restorations/temporaries, and denture repairs. A lack of access to FFP2/FFP3 (filtering facepiece) respirators was indicated by 59.4% Austrian, 38.0% German, and 11.7% Swiss dentists (p < 0.001). FFP2/FFP3 respirators were, when available, most frequently used in Austria (86.9%), followed by Switzerland (61.2%) and Germany (56.7%) (p < 0.001). Financial consequences could not be conclusively quantified by 58.6% of the participants. Most respondents in all partaking countries made use of governmental support. A lack of blueprints/guidelines resulted in heterogeneous working conditions. In consideration of a potentially high risk of infection in the dental setting, non-emergency dental treatments were largely suspended in all participating countries.

6.
Clin Oral Investig ; 25(1): 247-253, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32504217

RESUMO

OBJECTIVES: To compare the cleansing efficacy of a representative "ten seconds" auto-cleaning device with that of uninstructed manual toothbrushing in a pilot study. MATERIALS AND METHODS: Twenty periodontally healthy probands refrained from oral hygiene for 3 days. Baseline full-mouth plaque scores (Rustogi Modified Navy Plaque Index, RMNPI) were assessed. After randomization, probands cleaned their teeth either with the auto-cleaning test device according to the manufacturer's protocol or with a manual toothbrush. Plaque reduction was assessed by two aligned blinded investigators. After a 2-week recovery, the clinical investigation was repeated in a crossover design. The brushing pattern of the auto-cleaning device was analyzed in probands' casts. RESULTS: Full-mouth plaque reduction was 11.37 ± 3.70% for the auto-cleaning device and 31.39 ± 5.27% for manual toothbrushing (p < 0.0001). The investigation of the auto-cleaning device's brushing pattern in dental casts revealed a positive relationship of bristle rows in contact with tooth surfaces and the cleansing efficacy in the respective areas. A maximum of 2/4 bristle rows were in contact with the tooth surfaces; in some areas, the bristles had no contact to the teeth. CONCLUSIONS: Uninstructed manual toothbrushing is superior to auto-cleaning. The alignment and density of the auto-cleaning device's bristle rows need to be improved, and assorted sizes would be necessary to cover different jaw shapes. CLINICAL RELEVANCE: The auto-cleaning device has been developed to accommodate individuals with poor dexterity or compliance. To date, it is unable to provide sufficient plaque reduction due to an inappropriate bristle alignment and poor fit with diverse dental arches.


Assuntos
Eletrônica , Desenho de Equipamento , Escovação Dentária , Estudos Cross-Over , Índice de Placa Dentária , Humanos , Projetos Piloto , Método Simples-Cego
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...