Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Heliyon ; 10(8): e29256, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38628714

RESUMO

Background: Transient cortical blindness (TCB) has been reported as a complication after diagnostic cerebral angiography in 0.3-1% of cases. Our aim was to observe the frequency of TCB after diagnostic cerebral angiography over a period of 11 years using only hypo-osmolar, nonionic contrast agents and following a protocol to reduce both the total volume of injected contrast agent and the number of angiography series obtained. Methods: We retrospectively included all 2431 patients who received diagnostic cerebral angiographies at our institution. Primary outcome measure was the occurrence of TCB after diagnostic cerebral angiography, hypothesizing that the occurrence of TBC depends on the volume of contrast agent and angiography of the vertebrobasilary arteries. Results: Over the analyzed time period of 11 years, we did not observe a single case of TCB following diagnostic cerebral angiography. The median contrast volume used was 100 ml (IQR, 100-200), ranging from 15 ml to 500 ml. In our cohort, 61.5% of patients received a selective catheterization of the vertebrobasilary territory. In 99.8% of angiographies iopamidol was used a contrast agent. Conclusion: Our results indicate that following to certain aspects of the angiography protocol (using the hypoosmolar, non-ionic contrast agent iopamidol and reducing the number of catheterized vessels and angiography series to a diagnostic minimum) the frequency of transient cortical blindness as a complication of diagnostic cerebral angiography considerably can be very low.

2.
Cardiovasc Eng Technol ; 14(3): 393-403, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36814059

RESUMO

PURPOSE: Acute ischemic stroke is a life-threatening emergency caused by an occlusion of a cerebral artery through a blood clot. Aspiration thrombectomy is an endovascular therapy for the removal of vessel occlusions. However, open questions regarding the hemodynamics during the intervention remain, motivating investigations of blood flow within cerebral arteries. In this study, we present a combined experimental and numerical approach to analyze hemodynamics during endovascular aspiration. METHODS: We have developed an in vitro setup for investigations of hemodynamic changes during endovascular aspiration within a compliant model of patient-specific cerebral arteries. Pressures, flows, and locally resolved velocities were obtained. In addition, we established a computational fluid dynamics (CFD) model and compared the simulations during physiological conditions and in two aspiration scenarios with different occlusions. RESULTS: Flow redistribution within cerebral arteries after ischemic stroke is strongly dependent on the severity of the occlusion and on the volume flow extracted by endovascular aspiration. Numerical simulations exhibit an excellent correlation of R = 0.92 for flow rates and a good correlation of R = 0.73 for pressures. Further on, the local velocity field inside the basilar artery had a good agreement between CFD model and particle image velocimetry (PIV) data. CONCLUSION: The presented setup allows for in vitro investigations of artery occlusions and endovascular aspiration techniques on arbitrary patient-specific cerebrovascular anatomies. The in silico model provides consistent predictions of flows and pressures in several aspiration scenarios.


Assuntos
AVC Isquêmico , Humanos , Hemodinâmica , Simulação por Computador , Artérias Cerebrais , Reologia
3.
Clin Neuroradiol ; 33(1): 219-226, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36028628

RESUMO

PURPOSE: In intracranial wide-neck aneurysms, simple coil embolization is often not a feasible treatment option. Balloon-assisted coiling comes with the drawback of blood flow impairment, whereas permanent stent placement requires long-term antiplatelet therapy. Temporary stent-assisted coiling (coiling assisted by temporary stenting, CATS) is an alternative that eliminates both disadvantages. Because prior studies included only small numbers of patients, it was our aim to analyze the safety and effectiveness of this technique in a larger cohort of patients. METHODS: We retrospectively evaluated all endovascular aneurysm treatments at our institution from 2011 to 2020. Out of a total of 688 aneurysm treatments, we intended to perform 95 (14%) with temporary stent-assisted coiling and included them in our study. RESULTS: Sixty-four (64)% of aneurysms were acutely ruptured, 3% were symptomatic but unruptured, and 33% were incidental. Successful stent recovery was possible in 93% of treatments. Initial complete and adequate occlusion rate were 53% and 82%, respectively. Long-term follow-up at 6 and 12 months was available for 71% and 44% of cases. Aneurysm recurrence was observed in 10% of cases after 6 months, and in 17% after 1 year or later. Periprocedural complications were noted in 12 cases (13%), of which only 1 complication was definitely associated with temporary stent-assisted coiling (1%). One of the periprocedural complications resulted in neurological damage, the other complications were asymptomatic. CONCLUSION: Temporary stent-assisted coiling appears to be a safe and effective treatment method in intracranial wide-neck aneurysms. Procedural safety appears to be comparable with balloon remodeling or permanent stent-assisted coiling, but it comes with the further benefit of diminished need for posttreatment antiplatelet therapy, which may improve the outcome of patients. However, to define the true value and potential benefit of this technique, further prospective studies are required.


Assuntos
Aneurisma Roto , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Estudos Retrospectivos , Inibidores da Agregação Plaquetária , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/terapia , Stents/efeitos adversos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Aneurisma Intracraniano/complicações , Resultado do Tratamento , Embolização Terapêutica/métodos , Aneurisma Roto/terapia , Angiografia Cerebral
4.
AJNR Am J Neuroradiol ; 43(11): 1597-1602, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36229165

RESUMO

BACKGROUND AND PURPOSE: Radiographic shunt series are still the imaging technique of choice for radiologic evaluation of VP-shunt complications. Radiographic shunt series are associated with high radiation exposure and have a low diagnostic performance. Our aim was to investigate the diagnostic performance of whole-body ultra-low-dose CT for detecting mechanical ventriculoperitoneal shunt complications. MATERIALS AND METHODS: This retrospective study included 186 patients (mean age, 54.8 years) who underwent whole-body ultra-low-dose CT (100 kV[peak]; reference, 10 mAs). Two radiologists reviewed the images for the presence of ventriculoperitoneal shunt complications, image quality, and diagnostic confidence. On a 5-point Likert scale, readers scored image quality and diagnostic confidence (1 = very low, 5 = very high). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Radiation dose estimation of whole-body ultra-low-dose CT was calculated and compared with the radiation dose of a radiographic shunt series. RESULTS: 34 patients positive for VP-shunt complications were correctly identified on whole-body ultra-low-dose CT by both readers. No false-positive or -negative cases were recorded by any of the readers, yielding a sensitivity of 100% (95% CI, 87.3%-100%), a specificity of 100% (95% CI, 96.9%-100%), and perfect agreement (κ = 1). Positive and negative predictive values were high at 100%. Shunt-specific image quality and diagnostic confidence were very high (median score, 5; range, 5-5). Interobserver agreement was substantial for image quality (κ = 0.73) and diagnostic confidence (κ = 0.78). The mean radiation dose of whole-body ultra-low-dose CT was significantly lower than the radiation dose of a conventional radiographic shunt series (0.67 [SD, 0.4] mSv versus 1.57 [SD, 0.6] mSv; 95% CI, 0.79-1.0 mSv; P < .001). CONCLUSIONS: Whole-body ultra-low-dose CT allows detection of ventriculoperitoneal shunt complications with excellent diagnostic accuracy and diagnostic confidence. With concomitant radiation dose reduction on contemporary CT scanners, whole-body ultra-low-dose CT should be considered an alternative to the radiographic shunt series.


Assuntos
Exposição à Radiação , Derivação Ventriculoperitoneal , Humanos , Pessoa de Meia-Idade , Derivação Ventriculoperitoneal/efeitos adversos , Estudos Retrospectivos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Sensibilidade e Especificidade
5.
AJNR Am J Neuroradiol ; 43(9): 1299-1303, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35953279

RESUMO

BACKGROUND AND PURPOSE: Because stroke therapy has changed with the introduction of endovascular stroke treatment as a standard approach, studies on intrahospital causes of death from stroke are no longer up-to-date. The purpose of this observational study was to present the causes of death during hospitalization of patients with ischemic stroke who received endovascular stroke treatment, with the focus on a differentiation of curative and secondary palliative treatment. MATERIALS AND METHODS: We studied a total cohort of 1342 patients who received endovascular stroke treatment in a tertiary stroke center (Aachen, Germany) between 2010 and 2020 and analyzed the causes of death in all 326 consecutive deceased patients. We distinguished between curative treatment and a secondary palliative approach and analyzed causes of death and treatment numbers across the years. RESULTS: In the entire cohort of 326 deceased patients, the most common cause of death was of a cerebrovascular nature (51.5%), followed by pneumonia and sepsis (25.8%) and cardiovascular causes (8.3%). Neurovascular causes constituted 75.8% of reasons for palliation. In the group with a secondary palliative approach, causes of death were neurovascular in 54.0% of patients and pneumonia and sepsis in 26.0% of patients. CONCLUSIONS: Cerebrovascular causes in patients with stroke play a major role in the intrahospital causes of death and reasons for palliation. Considering the large proportion of secondarily palliative-treated patients, reasons for palliation should be considered instead of causes of death to avoid concealment by, for example, life-terminating measures.


Assuntos
Procedimentos Endovasculares , Pneumonia , Sepse , Acidente Vascular Cerebral , Humanos , Causas de Morte , Acidente Vascular Cerebral/terapia , Acidente Vascular Cerebral/etiologia , Causalidade , Pneumonia/etiologia , Sepse/etiologia , Resultado do Tratamento , Procedimentos Endovasculares/efeitos adversos
6.
Eur J Radiol ; 116: 55-60, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31153574

RESUMO

OBJECTIVE: To determine the changes in fractional anisotropy (FA) at the proximal spinal cord and in magnetic resonance spectroscopy (MRS) of the precentral gyrus in patients with cervical spondylotic myelopathy (CSM) with respect to clinical symptoms and their duration. MATERIAL AND METHODS: 20 patients with CSM (7 female; mean age 64.6 ± 10.5 years) and 18 age/sex matched healthy controls (9 female; mean age 63.5 ± 6.6 years) were prospectively included. Clinical data (modified Japanese Orthopaedic Association Score (mJOA) and Neck Disability Index (NDI)) and 3T MR measurements including DTI at the spinal cord (level C2/3) with FA and MRS of the left and right precentral gyrus were taken. Clinical correlations and regression analyses were performed. RESULTS: Mean clinical scores of patients were significantly different to controls (mJOA; CSM: 10.2 ± 2.9; controls: 18.0 ± 0.0, p < 0.001; NDI; CSM: 41.4±23.5; controls: 4.4±6.6, p<0.001); FA was significantly lower in patients (CSM: 0.645 ± 0.067; controls: 0.699 ± 0.037, p = 0.005). MRS showed significantly lower metabolite concentrations between both groups: creatine (Cr) (CSM: 46.46±7.64; controls: 51.36±5.76, p = 0.03) and N-acetylaspartate (NAA) (CSM: 93.94±19.22; controls: 107.24±20.20, p = 0.05). Duration of symptoms ≤6 months was associated with increased myo-inositol (Ins) (61.58±17.76; 44.44±10.79; p = 0.02) and Ins/Cr ratio (1.36±0.47; 0.96±0.18; p = 0.014) compared to symptoms >6 months. CONCLUSION: Metabolic profiles of the precentral gyrus and FA in the uppermost spinal cord differ significantly between patients and healthy controls. Ins, thought to be a marker of endogenous neuroinflammatory response, is high in the early course of CSM and normalizes over time.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Córtex Motor/diagnóstico por imagem , Córtex Motor/metabolismo , Doenças da Medula Espinal/patologia , Espondilose/patologia , Idoso , Anisotropia , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Biomarcadores/metabolismo , Vértebras Cervicais/diagnóstico por imagem , Vértebras Cervicais/patologia , Creatina/metabolismo , Feminino , Humanos , Inositol/metabolismo , Masculino , Pessoa de Meia-Idade , Córtex Motor/patologia , Doenças da Medula Espinal/metabolismo , Espondilose/metabolismo , Fatores de Tempo
7.
AJNR Am J Neuroradiol ; 40(5): 784-787, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30975653

RESUMO

BACKGROUND AND PURPOSE: Periventricular caps are a common finding on MR imaging and are believed to reflect focally increased interstitial water content due to dysfunctional transependymal transportation rather than ischemic-gliotic changes. We compared the quantitative water content of periventricular caps and microvascular white matter lesions, hypothesizing that periventricular caps associated with increased interstitial fluid content display higher water content than white matter lesions and are therefore differentiable from microvascular white matter lesions by measurement of the water content. MATERIALS AND METHODS: In a prospective study, we compared the water content of periventricular caps and white matter lesions in 50 patients using a quantitative multiple-echo, gradient-echo MR imaging water-mapping sequence. RESULTS: The water content of periventricular caps was significantly higher than that of white matter lesions (P = .002). Compared with normal white matter, the mean water content of periventricular caps was 17% ± 5% higher and the mean water content of white matter lesions was 11% ± 4% higher. Receiver operating characteristic analysis revealed that areas in which water content was 15% higher compared with normal white matter correspond to periventricular caps rather than white matter lesions, with a specificity of 93% and a sensitivity of 60% (P < .001). There was no significant correlation between the water content of periventricular caps and whole-brain volume (P = .275), white matter volume (P = .243), gray matter volume (P = .548), lateral ventricle volume (P = .800), white matter lesion volume (P = .081), periventricular cap volume (P = .081), and age (P = .224). CONCLUSIONS: Quantitative MR imaging allows differentiation between periventricular caps and white matter lesions. Water content quantification of T2-hyperintense lesions may be a useful additional tool for the characterization and differentiation of T2-hyperintense diseases.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Água/análise , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Hidrocefalia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Substância Branca/diagnóstico por imagem , Substância Branca/patologia
8.
Neuropathol Appl Neurobiol ; 45(6): 570-585, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31002412

RESUMO

OBJECTIVE: The aim of this study was to test the hypothesis that white matter degeneration of the perforant path - as part of the Papez circuit - is a key feature of amyotrophic lateral sclerosis (ALS), even in the absence of frontotemporal dementia (FTD) or deposition of pTDP-43 inclusions in hippocampal granule cells. METHODS: We used diffusion Magnetic Resonance Imaging (dMRI), polarized light imaging (PLI) and immunohistochemical analysis of post mortem hippocampus specimens from controls (n = 5) and ALS patients (n = 14) to study white matter degeneration in the perforant path. RESULTS: diffusion Magnetic Resonance Imaging demonstrated a decrease in fractional anisotropy (P = 0.01) and an increase in mean diffusivity (P = 0.01) in the perforant path in ALS compared to controls. PLI-myelin density was lower in ALS (P = 0.05) and correlated with fractional anisotropy (r = 0.52, P = 0.03). These results were confirmed by immunohistochemistry; both myelin (proteolipid protein, P = 0.03) and neurofilaments (SMI-312, P = 0.02) were lower in ALS. Two out of the fourteen ALS cases showed pTDP-43 pathology in the dentate gyrus, but with comparable myelination levels in the perforant path to other ALS cases. CONCLUSION: We conclude that degeneration of the perforant path occurs in ALS patients and that this may occur before, or independent of, pTDP-43 aggregation in the dentate gyrus of the hippocampus. Future research should focus on correlating the degree of cognitive decline to the amount of white matter atrophy in the perforant path.


Assuntos
Esclerose Lateral Amiotrófica/patologia , Hipocampo/patologia , Via Perfurante/patologia , Substância Branca/patologia , Idoso , Idoso de 80 Anos ou mais , Esclerose Lateral Amiotrófica/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Feminino , Hipocampo/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Via Perfurante/diagnóstico por imagem , Substância Branca/diagnóstico por imagem
9.
Eur J Neurol ; 26(3): 428-e33, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30317687

RESUMO

BACKGROUND AND PURPOSE: In 1995 intravenous recombinant tissue plasminogen activator (IVRTPA) was the first reperfusion therapy to be approved in patients with acute ischaemic stroke (AIS). The significance and impact of IVRTPA in times of modern endovascular stroke treatment (EST) were analysed in a German academic stroke centre. METHODS: A retrospective observational cohort analysis of 1034 patients with suspected AIS presenting at the emergency department in 2014 was performed. Patients were evaluated for baseline characteristics, reperfusion procedures, IVRTPA eligibility, clinical outcome, symptomatic intracranial haemorrhage (sICH) and mortality. Data acquisition was part of an investigator-initiated, prospective and blinded end-point registry. RESULTS: In 718 (69%) patients the diagnosis of symptomatic AIS was confirmed. 419 (58%) patients presented within 4.5 h of symptom onset and of those 260 (62%) received reperfusion therapy (IVRTPA alone, n = 183; combination or bridging therapy, n = 60; EST alone, n = 17). Subtracting cases with absolute contraindications for IVRTPA resulted in an effective thrombolysis rate of 82%. sICH occurred in two patients treated with IVRTPA alone (1.1%). The median door-to-needle interval was 30 min. Fifty (17%) non-EST eligible AIS patients presenting within 4.5 h without absolute contraindications did not receive IVRTPA mainly due to mild or regressive symptoms. Most of these untreated IVRTPA eligible patients (82%) were discharged with a good clinical outcome (modified Rankin Scale ≤ 2). CONCLUSIONS: Intravenous recombinant tissue plasminogen activator remains the most frequently applied reperfusion therapy in AIS patients presenting within 4.5 h of onset in a tertiary stroke centre. An effective thrombolysis rate of over 80% can be achieved without increased rates of sICH.


Assuntos
Isquemia Encefálica/tratamento farmacológico , Procedimentos Endovasculares/estatística & dados numéricos , Fibrinolíticos/uso terapêutico , Avaliação de Processos e Resultados em Cuidados de Saúde/estatística & dados numéricos , Acidente Vascular Cerebral/tratamento farmacológico , Terapia Trombolítica/estatística & dados numéricos , Ativador de Plasminogênio Tecidual/uso terapêutico , Administração Intravenosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Fibrinolíticos/administração & dosagem , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ativador de Plasminogênio Tecidual/administração & dosagem
10.
AJNR Am J Neuroradiol ; 40(1): 25-32, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30573461

RESUMO

BACKGROUND AND PURPOSE: The rupture of an intracranial aneurysm is a serious incident, causing subarachnoid hemorrhage associated with high fatality and morbidity rates. Because the demand for radiologic examinations is steadily growing, physician fatigue due to an increased workload is a real concern and may lead to mistaken diagnoses of potentially relevant findings. Our aim was to develop a sufficient system for automated detection of intracranial aneurysms. MATERIALS AND METHODS: In a retrospective study, we established a system for the detection of intracranial aneurysms from 3D TOF-MRA data. The system is based on an open-source neural network, originally developed for segmentation of anatomic structures in medical images. Eighty-five datasets of patients with a total of 115 intracranial aneurysms were used to train the system and evaluate its performance. Manual annotation of aneurysms based on radiologic reports and critical revision of image data served as the reference standard. Sensitivity, false-positives per case, and positive predictive value were determined for different pipelines with modified pre- and postprocessing. RESULTS: The highest overall sensitivity of our system for the detection of intracranial aneurysms was 90% with a sensitivity of 96% for aneurysms with a diameter of 3-7 mm and 100% for aneurysms of >7 mm. The best location-dependent performance was in the posterior circulation. Pre- and postprocessing sufficiently reduced the number of false-positives. CONCLUSIONS: Our system, based on a deep learning convolutional network, can detect intracranial aneurysms with a high sensitivity from 3D TOF-MRA data.


Assuntos
Aprendizado Profundo , Imageamento Tridimensional/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Neuroimagem/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
11.
AJNR Am J Neuroradiol ; 39(11): 2077-2081, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30309845

RESUMO

BACKGROUND AND PURPOSE: Blood flow management in the carotid artery during mechanical thrombectomy is crucial for safety and effectiveness. There is an ongoing discussion about whether balloon-guide catheters or large-bore sheaths are needed for effective flow management. We compared general flow characteristics of proximal aspiration through a large-bore sheath and a balloon-guide catheter in a porcine in vivo model. MATERIALS AND METHODS: We investigated blood flow in a porcine common carotid artery with and without aspiration (VacLok syringe and Penumbra pump, Pump MAX) through an 8F-long sheath and an 8F balloon-guide catheter. Blood hemodynamics were assessed via continuous duplex sonography. RESULTS: Average vessel diameter and baseline blood flow were 4.4 ± 0.2 mm and 244 ± 20 mL/min, respectively. For the 8F sheath, pump aspiration resulted in a significant flow reduction (225 ± 25 mL/min, P < .001), but with a persisting antegrade stream. Manual aspiration resulted in collapse of the vessel in 2 of 7 measurements and oscillatory flow with antegrade systolic and retrograde diastolic components in the remaining 5 measurements. Net flow was antegrade (52 ± 44 mL/min) in 3 and retrograde (-95 ± 52 mL/min) in the remaining 2 measurements. For balloon-guide catheters, balloon inflation always resulted in flow arrest. Additional pump or manual aspiration resulted in significant flow reversal of -1100 ± 230 and -468 ± 46 mL/min, respectively (both, P < .001). CONCLUSIONS: Only balloon-guide catheters allow reliable blood flow arrest and flow reversal in combination with aspiration via syringes or high-flow pump systems. Aspiration through an 8F sheath results in either collapse of the vessel or oscillatory flow, which can result in a net antegrade or retrograde stream.


Assuntos
Catéteres , Circulação Cerebrovascular , Trombectomia/instrumentação , Animais , Artéria Carótida Primitiva/cirurgia , Feminino , Stents , Acidente Vascular Cerebral/cirurgia , Suínos , Trombectomia/métodos
12.
AJNR Am J Neuroradiol ; 39(5): 905-909, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29650784

RESUMO

BACKGROUND AND PURPOSE: Blood flow should be interrupted during mechanical thrombectomy to prevent embolization of clot fragments. The purpose of our study was to provide a handy overview of the most common aspiration devices and to quantify their flow characteristics. MATERIALS AND METHODS: We assessed volumetric flow rates generated by a 60-mL VacLok vacuum pressure syringe, a Pump MAX aspiration pump, and a Dominant Flex suction pump connected to the following: 1) an 8F long sheath, 2) an 8F balloon-guide catheter, 3) an ACE 64 distal aspiration catheter, and 4) an AXS Catalyst 6 Distal Access Catheter. We used a water/glycerol solution, which was kept at a constant temperature of 20°C (viscosity, 3.7 mPa · s). RESULTS: Aspiration with the syringe and the Dominant Flex suction pump achieved the highest flows, whereas aspiration with the Pump MAX was significantly lower (P < .001). Resistors in the aspiration system (tubing, connectors, and so forth) restricted flows, especially when the resistance of the catheter was small (due to its large diameter) and the connected resistors became the predominant resistance (P < .001). The syringe achieved an average vacuum pressure of -90 kPa, and the resulting flow was constant during almost the entire procedure of filling the syringe. CONCLUSIONS: Sixty-milliliter VacLok vacuum pressure syringes and the Dominant Flex suction pump achieved high and constant flows likely sufficient to reverse blood flow during thrombectomy with an 8F sheath or balloon-guide catheter in the ICA and modern distal aspiration catheters in the MCA. The Pump MAX aspiration pump is dedicated for use with distal aspiration catheters and is unlikely to reverse blood flow in the ICA and MCA without balloon protection.


Assuntos
Sucção/instrumentação , Sucção/métodos , Trombectomia/instrumentação , Trombectomia/métodos , Catéteres , Procedimentos Endovasculares , Humanos , Modelos Biológicos , Seringas
13.
Clin Radiol ; 73(2): 218.e9-218.e15, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28811040

RESUMO

AIM: To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. METHODS: The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n=20; clipping: n=15; coiling + stenting: n=9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-images (1.5 or 3 T). Nominal data were analysed using McNemar's chi-square test and ordinal variables using the Wilcoxon rank test. RESULTS: Compared to TOF-MRA, MAR-FPCTA was significantly better suited to detect aneurysm remnants and to evaluate parent vessels after clipping (p<0.01). For coil packages >160 mm3, TOF-MRA provided significantly better assessment than MAR-FPCTA (p<0.01). For small coil packages (<160 mm3), no significant difference between TOF-MRA and MAR-FPCTA (p=0.232) was observed. For different clip sizes (cut-off 492 mm3) likewise no significant differences were found. The interobserver comparison showed high interrater agreement. CONCLUSION: MAR-FPCTA is significantly better suited for follow-up examinations of clipped aneurysms, whereas for larger coil packages TOF-MRA is preferable. Smaller coil packages can be analysed using MAR-FPCTA or TOF-MRA.


Assuntos
Artefatos , Angiografia Cerebral/métodos , Angiografia por Tomografia Computadorizada/métodos , Processamento de Imagem Assistida por Computador/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste , Seguimentos , Humanos , Aumento da Imagem/métodos , Aneurisma Intracraniano/terapia , Metais , Próteses e Implantes , Estudos Retrospectivos , Stents , Instrumentos Cirúrgicos
14.
Sol Phys ; 293(11): 149, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30880844

RESUMO

The Interface Region Imaging Spectrograph (IRIS) is a NASA small explorer mission that provides high-resolution spectra and images of the Sun in the 133 - 141 nm and 278 - 283 nm wavelength bands. The IRIS data are archived in calibrated form and made available to the public within seven days of observing. The calibrations applied to the data include dark correction, scattered light and background correction, flat fielding, geometric distortion correction, and wavelength calibration. In addition, the IRIS team has calibrated the IRIS absolute throughput as a function of wavelength and has been tracking throughput changes over the course of the mission. As a resource for the IRIS data user, this article describes the details of these calibrations as they have evolved over the first few years of the mission. References to online documentation provide access to additional information and future updates.

15.
AJNR Am J Neuroradiol ; 38(12): 2277-2281, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29025728

RESUMO

BACKGROUND AND PURPOSE: Large-bore catheters allow mechanical thrombectomy in ischemic stroke by engaging and retrieving clots without additional devices (direct aspiration first-pass technique [ADAPT]). The purpose of this study was to establish a model for minimal catheter diameters needed for ADAPT. MATERIALS AND METHODS: We established a theoretic model for the calculation of minimal catheter diameters needed for ADAPT. We then verified its validity in 28 ADAPT maneuvers in a porcine in vivo model. To account for different mechanical thrombectomy techniques, we factored in ADAPT with/without a hypothetic 0.021-inch microcatheter or 0.014-inch microwire inside the lumen of the aspiration catheter and aspiration with a 60-mL syringe versus an aspiration pump. RESULTS: According to our calculations, catheters with an inner diameter of >0.040 inch and >0.064 inch, respectively, are needed to be effective in the middle cerebral artery (2.5-mm diameter) or in the internal carotid artery (4 mm) in an average patient. There was a significant correlation between predicted and actual thrombectomy results (P = .010). Our theoretic model had a positive and negative predictive value of 78% and 79%, respectively. Sensitivity and specificity were 88% and 64%, respectively. CONCLUSIONS: Our theoretic model allows estimating the minimal catheter diameters needed for successful mechanical thrombectomy with ADAPT, as demonstrated by the good agreement with our animal experiments. Our model will be helpful to interventionalists in avoiding selecting catheters that are likely too small to be effective.


Assuntos
Catéteres , Trombólise Mecânica/instrumentação , Acidente Vascular Cerebral/terapia , Animais , Suínos , Resultado do Tratamento
16.
Interv Neuroradiol ; 23(6): 583-588, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28944705

RESUMO

Purpose Carotid artery anatomy is thought to influence internal carotid artery access time (ICA-AT) in patients requiring mechanical thrombectomy for acute ischemic stroke. This study investigates the association between ICA-AT and carotid anatomy. Material and methods Computed tomography angiography (CTA) data of 76 consecutive patients presenting with acute ischemic stroke requiring mechanical thrombectomy for middle cerebral artery or carotid T occlusion were evaluated. The supraaortic extracranial vasculature was analyzed regarding take-off angles and curvature of the affected side. Digital subtraction angiography data were primarily analyzed regarding ICA-AT and secondarily regarding recanalization time and radiographic result. Results ICA-AT was significantly influenced by vessel tortuosity. Take-off angle of the left common carotid artery ( p = 0.001) and the brachiocephalic trunk ( p = 0.002) as well as the tortuosity of the common carotid artery ( p = 0.002) had highest impact on ICA-AT. For recanalization time, however, we found only the take-off angle of the left common carotid artery to be of significance ( p = 0.020). There was a tendency for ICA-AT to correlate with successful (mTICI ≥ 2 b) revascularization (average time of successful results was 24.3 minutes, of unsuccessful was 35.6 minutes; p = 0.065). Every evaluated segment with less carotid tortuosity showed a carotid AT below 25 minutes. Conclusion Supraaortic vessel tortuosity significantly influences ICA-AT in mechanical thrombectomy for an acute large vessel. There furthermore was a trend for lower successful recanalization rates with increasing ICA-AT.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Artéria Carótida Interna/anormalidades , Estenose das Carótidas/diagnóstico por imagem , Trombólise Mecânica , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Idoso , Angiografia Digital , Angiografia Cerebral , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Masculino , Resultado do Tratamento
17.
AJNR Am J Neuroradiol ; 38(7): 1372-1376, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28473345

RESUMO

BACKGROUND AND PURPOSE: Simple coil embolization is often not a feasible treatment option in wide-neck aneurysms. Stent-assisted coil embolization helps stabilize the coils within the aneurysm. Permanent placement of a stent in an intracranial vessel, however, requires long-term platelet inhibition. Temporary stent-assisted coiling is an alternative technique for the treatment of wide-neck aneurysms. To date, only case reports and small case series have been published. Our purpose was to retrospectively analyze the effectiveness and safety of temporary stent-assisted coiling in a larger cohort. MATERIALS AND METHODS: Research was performed for all patients who had undergone endovascular aneurysm treatment in our institution (University Hospital Aachen) between January 2010 and December 2015. During this period, 355 consecutive patients had undergone endovascular aneurysm treatment. We intended to treat 33 (9.2%) of them with temporary stent-assisted coiling, and they were included in this study. Incidental and acutely ruptured aneurysms were included. RESULTS: Sufficient occlusion was achieved in 97.1% of the cases. In 94%, the stent could be fully recovered. Complications occurred in 5 patients (14.7%), whereas in only 1 case was the complication seen as specific to stent-assisted coiling. CONCLUSIONS: Temporary stent-assisted coiling is an effective technique for the treatment of wide-neck aneurysms. Safety is comparable with that of stent-assisted coiling and coiling with balloon remodeling.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Stents , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolectomia com Balão , Estudos de Coortes , Remoção de Dispositivo , Embolização Terapêutica/efeitos adversos , Procedimentos Endovasculares , Feminino , Seguimentos , Humanos , Embolia Intracraniana/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
18.
Int J Obes (Lond) ; 41(6): 935-944, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28220041

RESUMO

OBJECTIVE: Midlife obesity affects cognition and increases risk of developing dementia. Recent data suggest that intake of the short chain fatty acid butyrate could improve memory function, and may protect against diet-induced obesity by reducing body weight and adiposity. SUBJECTS: We examined the impact of a high-fat diet (HFD) followed by intervention with 5% (w/w) dietary butyrate, on metabolism, microbiota, brain function and structure in the low-density-lipoprotein receptor knockout (LDLr-/-) mouse model in mid and late life. RESULTS: In mid-adult mice, 15 weeks of HFD-induced adiposity, liver fibrosis and neuroinflammation, increased systolic blood pressure and decreased cerebral blood flow, functional connectivity assessed with neuroimaging. The subsequent 2 months butyrate intervention restored these detrimental effects to chow-fed control levels. Both HFD and butyrate intervention decreased variance in fecal microbiota composition. In late-adult mice, HFD showed similar detrimental effects and decreased cerebral white and gray matter integrity, whereas butyrate intervention attenuated only metabolic parameters. CONCLUSION: HFD induces detrimental effects in mid- and late-adult mice, which can be attenuated by butyrate intervention. These findings are consistent with reported associations between midlife obesity and cognitive impairment and dementia in humans. We suggest that butyrate may have potential in prevention and treatment of midlife obesity.


Assuntos
Adiposidade/efeitos dos fármacos , Butiratos/farmacologia , Circulação Cerebrovascular/efeitos dos fármacos , Transtornos Cognitivos/tratamento farmacológico , Dieta Hiperlipídica/efeitos adversos , Inflamação/tratamento farmacológico , Fármacos Neuroprotetores/farmacologia , Animais , Transtornos Cognitivos/fisiopatologia , Modelos Animais de Doenças , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Inflamação/fisiopatologia , Cirrose Hepática/tratamento farmacológico , Cirrose Hepática/fisiopatologia , Masculino , Camundongos , Camundongos Obesos
19.
J Neurointerv Surg ; 9(12): 1223-1227, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27998957

RESUMO

INTRODUCTION: The direct aspiration first pass technique (ADAPT) has been introduced as a rapid and safe endovascular treatment strategy in patients with ischemic stroke. OBJECTIVE: To determine the technical feasibility, safety, and functional outcome with ADAPT using the new large-bore 6F SOFIA Plus catheter. METHODS: A retrospective analysis of prospectively collected data from six university hospitals was performed. The following parameters of all acute stroke procedures (June 2015- January 2016) using the SOFIA Plus catheter were analyzed: accessibility of the thrombus with the catheter, recanalization success (Thrombolysis in Cerebral Infarction ≥2b), time to recanalization, procedure-related complications. Furthermore, National Institutes of Health Stroke Scale (NIHSS) scores at presentation and discharge and the modified Rankin scale (mRS) score at 90 days were recorded. RESULTS: 85 patients were treated using the SOFIA Plus catheter. The occlusion site was the anterior circulation in 94.1%. Median baseline NIHSS score was 18. In 64.7%, ADAPT alone was successful after a median procedure time of 21 min. With additional use of stent retrievers in the remaining cases, the recanalization rate was 96.5%. No catheter-related complications such as dissections were observed. Thrombus migration to a new vascular territory occurred in 4.7% and symptomatic hemorrhage in 4.7%. After 3 months, mRS 0-2 was achieved in 49.4%. Mortality rate was 20%. CONCLUSIONS: In the majority of cases, thrombus aspiration using the SOFIA Plus catheter results in successful recanalization after a short procedure time. With additional use of stent retrievers, a high recanalization rate can be achieved (96.5%). The complication rate was in line with those of previous publications.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Catéteres , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia/instrumentação , Adulto , Idoso , Catéteres/efeitos adversos , Feminino , Humanos , Pessoa de Meia-Idade , Alta do Paciente/tendências , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Estudos Retrospectivos , Stents/efeitos adversos , Trombectomia/efeitos adversos , Trombectomia/métodos , Resultado do Tratamento
20.
Clin Neuroradiol ; 27(3): 311-318, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26669592

RESUMO

PURPOSE: We aimed to compare different computed tomography (CT) perfusion post-processing algorithms regarding image quality of perfusion maps from low-dose volume perfusion CT (VPCT) and their diagnostic performance regarding the detection of ischemic brain lesions. METHODS AND MATERIALS: We included VPCT data of 21 patients with acute stroke (onset < 6h), which were acquired at 80 kV and 180 mAs. Low-dose VPCT datasets with 72 mAs (40 % of original dose) were generated using realistic low-dose simulation. Perfusion maps (cerebral blood volume (CBV); cerebral blood flow (CBF) from original and low-dose datasets were generated using two different commercially available post-processing methods: deconvolution-based method (DC) and maximum slope algorithm (MS). The resulting DC and MS perfusion maps were compared regarding perfusion values, signal-to-noise ratio (SNR) as well as image quality and diagnostic accuracy as rated by two blinded neuroradiologists. RESULTS: Quantitative perfusion parameters highly correlated for both algorithms and both dose levels (r ≥ 0.613, p < 0.001). Regarding SNR levels and image quality of the CBV maps, no significant differences between DC and MS were found (p ≥ 0.683). Low-dose MS CBF maps yielded significantly higher SNR levels (p < 0.001) and quality scores (p = 0.014) than those of DC. Low-dose CBF and CBV maps from both DC and MS yielded high sensitivity and specificity for the detection of ischemic lesions (sensitivity ≥ 0.82, specificity ≥ 0.90). CONCLUSION: Our results indicate that both methods produce diagnostically sufficient perfusion maps from simulated low-dose VPCT. However, MS produced CBF maps with significantly higher image quality and SNR than DC, indicating that MS might be more suitable for low-dose VPCT imaging.


Assuntos
Algoritmos , Encéfalo/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...