1.
Abdom Radiol (NY) ; 47(10): 3375-3385, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35798962

RESUMO

PURPOSE: To investigate whether locoregional staging of colon cancer by experienced radiologists can be improved by training and feedback to minimize the risk of over-staging into the context of patient selection for neoadjuvant therapy and to identify potential pitfalls of CT staging by characterizing pathologic traits of tumors that remain challenging for radiologists. METHODS: Forty-five cases of stage I-III colon cancer were included in this retrospective study. Five experienced radiologists evaluated the CTs; 5 baseline scans followed by 4 sequential batches of 10 scans. All radiologists were trained after baseline scoring and 2 radiologists received feedback. The learning curve, diagnostic performance, reader confidence, and reading time were evaluated with pathologic staging as reference. Pathology reports and H&E slides of challenging cases were reviewed to identify potential pitfalls. RESULTS: Diagnostic performance in distinguishing T1-2 vs. T3-4 improved significantly after training and with increasing number of reviewed cases. Inaccurate staging was more frequently related to under-staging rather than over-staging. Risk of over-staging was minimized to 7% in batch 3-4. N-staging remained unreliable with an overall accuracy of 61%. Pathologic review identified two tumor characteristics causing under-staging for T-stage in 5/7 cases: (1) very limited invasive part beyond the muscularis propria and (2) mucinous composition of the invading part. CONCLUSION: The high accuracy and specificity of T-staging reached in our study indicate that sufficient training and practice of experienced radiologists can ensure high validity for CT staging in colon cancer to safely use neoadjuvant therapy without significant risk of over-treatment, while N-staging remained unreliable.


Assuntos
Neoplasias do Colo , Neoplasias do Colo/diagnóstico por imagem , Neoplasias do Colo/patologia , Humanos , Estadiamento de Neoplasias , Radiologistas , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
2.
Phys Med Biol ; 62(13): 5312-5326, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28557798

RESUMO

The incidence of small renal masses (SRMs) sized <4 cm has increased over the decades (as co-findings/or due to introduction of cross sectional imaging). Currently, partial nephrectomy (PN) or watchful waiting is advised in these patients. Ultimately, 80-90% of these SRMs require surgical treatment and PN is associated with a 15% complication rate. In this aging population, with possible comorbidities and poor health condition, both PN and watchful waiting are non-ideal treatment options. This resulted in an increased need for early, non-invasive treatment strategies such as MR-guided high intensity focused ultrasound (MR-HIFU). (i) To investigate the feasibility of creating a confluent lesion in the kidney using respiratory-gated MR-HIFU under clinical conditions in a pre-clinical study and (ii) to evaluate the reproducibility of the MR-HIFU ablation strategy. Healthy pigs (n = 10) under general anesthesia were positioned on a clinical MR-HIFU system with integrated cooling. A honeycomb pattern of seven overlapping ablation cells (4 × 4 × 10 mm3, 450 W, <30 s) was ablated successively in the cortex of the porcine kidney. Both MR thermometry and acoustic energy delivery were respiratory gated using a pencil beam navigator on the contralateral kidney. The non-perfused volume (NPV) was visualized after the last sonication by contrast-enhanced (CE) T 1-weighted MR (T 1 w) imaging. Cell viability staining was performed to visualize the extent of necrosis. RESULTS: a median NPV of 0.62 ml was observed on CE-T 1 w images (IQR 0.58-1.57 ml, range 0.33-2.75 ml). Cell viability staining showed a median damaged volume of 0.59 ml (IQR 0.24-1.35 ml, range 0-4.1 ml). Overlooking of the false rib, shivering of the pig, and too large depth combined with a large heat-sink effect resulted in insufficient heating in 4 cases. The NPV and necrosed volume were confluent in all cases in which an ablated volume could be observed. Our results demonstrated the feasibility of creating a confluent volume of ablated kidney cortical tissue in vivo with MR-HIFU on a clinically available system using respiratory gating and near-field cooling and showed its reproducibility.


Assuntos
Técnicas de Ablação/métodos , Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Rim/diagnóstico por imagem , Rim/cirurgia , Imageamento por Ressonância Magnética , Cirurgia Assistida por Computador/métodos , Suínos , Animais , Feminino , Reprodutibilidade dos Testes , Temperatura
3.
Med Phys ; 42(8): 4685-97, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26233196

RESUMO

PURPOSE: One of the major issues in high intensity focused ultrasound ablation of abdominal lesions is obstruction of the ultrasound beam by the thoracic cage. Beam shaping strategies have been shown by several authors to increase focal point intensity while limiting rib exposure. However, as rib obstruction leaves only part of the aperture available for energy transmission, conserving total emitted acoustic power, the intensity in the near-field tissues inherently increases after beam shaping. Despite of effective rib sparing, those tissues are therefore subjected to increased risk of thermal damage. In this study, for a number of clinically representative intercostal sonication geometries, modeling clinically available hardware, the effect of beam shaping on both the exposure of the ribs and near-field to acoustic energy was evaluated and the implications for the volumetric ablation rate were addressed. METHODS: A relationship between rib temperature rise and acoustic energy density was established by means of in vivo MR thermometry and simulations of the incident acoustic energy for the corresponding anatomies. This relationship was used for interpretation of rib exposure in subsequent numerical simulations in which rib spacing, focal point placement, and the focal point trajectory were varied. The time required to heat a targeted region to 65 °C was determined without and with the application of beam shaping. The required sonication time was used to calculate the acoustic energy density at the fat-muscle interface and at the surface of the ribs. At the fat-muscle interface, exposure was compared to available literature data and rib exposure was interpreted based on the earlier obtained relation between measured temperature rise and simulated acoustic energy density. To estimate the volumetric ablation rate, the cool-down time between periods of energy exposure was estimated using a time-averaged power limit of 100 kJ/h. RESULTS: At the level of the ribs, the temperature rise-energy density proportionality constant was estimated to be 6.0-7.6 °C/(J/mm(2)). Beam shaping by the geometric shadow method typically reduces the acoustic intensity a factor of 2, considering the 1 cm(2) with the highest exposure. For a 4 mm diameter circular sonication trajectory, the near-field energy limit of 2.5 J/mm(2) was exceeded for all considered geometries. The estimated rib temperature was in all but one (sonication 50 mm behind the ribs, with 15 mm rib spacing and a 4 mm diameter circular sonication trajectory) of the considered scenarios within acceptable limits. For those sonication scenarios where a single sonication is considered safe both in terms of near-field as well as rib heating, volumetric ablation rates in the order of 1 ml/h are estimated. CONCLUSIONS: Intercostal sonication is associated with an increased risk of near-field overheating. This risk is strongly dependent on the considered rib spacing, the placement of the focus behind the ribs, and the selected sonication trajectory. For the hardware under simulation, obstruction by the thoracic cage renders ablations of clinically relevant volumes within a practical time-frame unfeasible in a large part of the liver. Improvements maybe expected from transducer designs with a larger active surface and/or nonlinear sonication strategies.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Fígado/cirurgia , Tecido Adiposo/fisiologia , Simulação por Computador , Estudos de Viabilidade , Ablação por Ultrassom Focalizado de Alta Intensidade/instrumentação , Humanos , Fígado/fisiopatologia , Modelos Biológicos , Músculos/fisiologia , Órgãos em Risco , Costelas/anatomia & histologia , Costelas/fisiologia , Temperatura
4.
Cancer Imaging ; 12: 387-94, 2012 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-23022541

RESUMO

Recent decades have seen a paradigm shift in the treatment of liver tumours from invasive surgical procedures to minimally invasive image-guided ablation techniques. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a novel, completely non-invasive ablation technique that has the potential to change the field of liver tumour ablation. The image guidance, using MR imaging and MR temperature mapping, provides excellent planning images and real-time temperature information during the ablation procedure. However, before clinical implementation of MR-HIFU for liver tumour ablation is feasible, several organ-specific challenges have to be addressed. In this review we discuss the MR-HIFU ablation technique, the liver-specific challenges for MR-HIFU tumour ablation, and the proposed solutions for clinical translation.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Neoplasias Hepáticas/terapia , Imageamento por Ressonância Magnética , Humanos