Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Echocardiogr ; 8(2): 94-101, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16564232

RESUMO

The pulsed Doppler early diastolic left ventricular (LV) tissue (e)-blood (E) onset temporal relationship (e-E) is suggested to predict pulmonary capillary wedge pressure (PCWP), through the formulas: tau = 32 + 0.7(e-E) and PCWP = LV end-systolic pressure x e(-IVRT/tau). Small changes/errors in E could influence the quotient IVRT/tau by oppositely affecting IVRT and e-E. At rest in 50 healthy individuals we noted: e-E: 2 +/- 14 ms; IVRT: 89 +/- 17 ms; calculated tau: 33 +/- 10 ms; and PCWP: 9 +/- 9 mmHg (> 12 mmHg in 28%). Non-pharmacological preload alterations in 14 individuals rendered an intraindividual 'PCWP'-fluctuation of up to 40 mmHg. This application may therefore not be clinically robust.


Assuntos
Diástole/fisiologia , Modelos Cardiovasculares , Pressão Propulsora Pulmonar/fisiologia , Função Ventricular , Idoso , Ecocardiografia Doppler de Pulso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Fatores de Tempo
2.
Eur J Echocardiogr ; 6(6): 419-28, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16293528

RESUMO

AIM: A ratio>15 between the early diastolic pulsed Doppler velocities of the mitral inflow (E) and the basal left ventricular (LV) tissue (e) has been demonstrated to predict an elevated LV filling pressure (FP). An elevated LVFP implies an elevated right ventricular pressure (RVp). In order to investigate the sensitivity of the E/e filling index, we compared E/e and RVp, in their ability to identify a Doppler-assumed elevation of LVFP. METHODS AND RESULTS: Application of pulsed Doppler international recommendations grouped 134 patients with acute coronary syndromes (ACS) and 50 age- and sex-matched controls, according to LV filling: normal; delayed relaxation; an isolated pathological mitral-pulmonary venous-A-wave-duration difference; pseudo normal; or a restrictive filling pattern. An E/e>15 and an RVp>30 mmHg showed the following (%) sensitivity (32/94), specificity (95/76), positive (68/59), and negative (80/97) predictive values of a Doppler-assumed elevation of LVFP, in terms of either a pseudo normal or a restrictive filling pattern. CONCLUSION: The low sensitivity of E/e to detect a Doppler-assumed elevation of LVFP could limit its clinical usefulness as a single variable, in ACS. The high sensitivity and negative predictive value of RVp support its use as an additional LV filling variable in these patients.


Assuntos
Ecocardiografia Doppler de Pulso , Ventrículos do Coração/diagnóstico por imagem , Função Ventricular Esquerda , Função Ventricular Direita , Pressão Ventricular , Idoso , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Função Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...