Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ultrasonics ; 82: 44-48, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28750316

RESUMO

This article reports a technique for near-surface ultrasonic array imaging. Information equivalent to an undelayed full matrix of inter-element responses is produced through cross-correlation of a later time diffuse full matrix. This reconstructed full matrix lacks the nonlinear effects of early time saturation present in a directly acquired response. Consequently the near-surface material information usually obscured by this effect is retrieved. Furthermore it is shown that a hybrid full matrix formed through a temporally weighted sum of coherent and reconstructed matrices allows for effective near-surface and bulk material imaging from a single direct-contact experimental realisation.

2.
Opt Express ; 23(1): 26-32, 2015 Jan 12.
Artigo em Inglês | MEDLINE | ID: mdl-25835651

RESUMO

We demonstrate the generation of Bessel beams using an acousto-optic array based on a liquid filled cavity surrounded by a cylindrical multi-element ultrasound transducer array. Conversion of a Gaussian laser mode into a Bessel beam with tunable order and position is shown. Also higher-order Bessel beams up to the fourth order are successfully generated with experimental results very closely matching simulations.

3.
Phys Rev Lett ; 113(14): 144301, 2014 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-25325647

RESUMO

This Letter reports a technique for the imaging of acoustic nonlinearity. By contrasting the energy of the diffuse field produced through the focusing of an ultrasonic array by delayed parallel element transmission with that produced by postprocessing of sequential transmission data, acoustic nonlinearity local to the focal point is measured. Spatially isolated wave distortion is inferred without requiring interrogation of the wave at the inspection point, thereby allowing nonlinear imaging through depth.


Assuntos
Modelos Teóricos , Ultrassom/métodos , Acústica , Processamento de Imagem Assistida por Computador , Dinâmica não Linear , Termodinâmica
4.
Artigo em Inglês | MEDLINE | ID: mdl-25004543

RESUMO

Ultrasonic array imaging algorithms have been widely used and developed in nondestructive evaluation in the last 10 years. In this paper, three imaging algorithms [total focusing method (TFM), phase-coherent imaging (PCI), and spatial compounding imaging (SCI)] are compared through both simulation and experimental measurements. In the simulation, array data sets were generated using a hybrid forward model containing a single defect among a multitude of randomly distributed point scatterers to represent backscatter from material microstructure. The number of point scatterers per unit area and their scattering amplitude were optimized to reduce computation cost. The SNR of the final images and their resolution were used to indicate the quality of the different imaging algorithms. The images of different types of defects (point reflectors and planar cracks) were used to investigate the robustness of the imaging algorithms. It is shown that PCI can yield higher image resolution and higher SNR for defects in material with weak backscatter than TFM, but that the images of cracks are distorted. Overall, TFM is the most robust algorithm across a range of different types of defects. It is also shown that the detection limit of all three imaging algorithms is almost equal for weakly scattering defects.

5.
J Acoust Soc Am ; 131(5): 3664-70, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559343

RESUMO

Acoustic radiation force exerted by standing waves on particles is analyzed using a finite difference time domain Lagrangian method. This method allows the acoustic radiation force to be obtained directly from the solution of nonlinear fluid equations, without any assumptions on size or geometry of the particles, boundary conditions, or acoustic field amplitude. The model converges to analytical results in the limit of small particle radii and low field amplitudes, where assumptions within the analytical models apply. Good agreement with analytical and numerical models based on solutions of linear scattering problems is observed for compressible particles, whereas some disagreement is detected when the compressibility of the particles decreases.

6.
J Acoust Soc Am ; 128(4): EL195-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20968325

RESUMO

A method of manipulating microparticles in a liquid using ultrasound is proposed and demonstrated. An ultrasonic standing wave with nodal planes whose positions are controllable by varying the relative phase of two applied sinusoidal signals is generated using a pair of acoustically matched piezoelectric transducers. The resulting acoustic radiation force is used to trap micron scale particles at a series of arbitrary positions (determined by the relative phase) and then move them in a controlled manner. This method is demonstrated experimentally and 5 µm polystyrene particles are trapped and moved in one dimension through 140 µm.


Assuntos
Poliestirenos , Ultrassom , Modelos Teóricos , Movimento (Física) , Tamanho da Partícula , Transdutores , Ultrassom/instrumentação
7.
Ultrasonics ; 49(6-7): 538-48, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19328512

RESUMO

A model for quantifying the performance of acoustic emission (AE) systems on plate-like structures is presented. Employing a linear transfer function approach the model is applicable to both isotropic and anisotropic materials. The model requires several inputs including source waveforms, phase velocity and attenuation. It is recognised that these variables may not be readily available, thus efficient measurement techniques are presented for obtaining phase velocity and attenuation in a form that can be exploited directly in the model. Inspired by previously documented methods, the application of these techniques is examined and some important implications for propagation characterisation in plates are discussed. Example measurements are made on isotropic and anisotropic plates and, where possible, comparisons with numerical solutions are made. By inputting experimentally obtained data into the model, quantitative system metrics are examined for different threshold values and sensor locations. By producing plots describing areas of hit success and source location error, the ability to measure the performance of different AE system configurations is demonstrated. This quantitative approach will help to place AE testing on a more solid foundation, underpinning its use in industrial AE applications.

8.
Ultrasonics ; 48(5): 367-75, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18348894

RESUMO

This paper presents the fabrication and characterisation of a flexible ultrasonic transducer using commercially available PZT-5A piezoelectric fibers which are lapped to form rectangular piezoelectric elements. The key feature in the device construction is the inclusion of gaps between the piezoelectric fibers to ensure good flexibility in the plane normal to the fiber direction. The spatial response of the transducer ultrasonic output was assessed using acoustographic imaging. The flexibility of the transducer and its applicability in pulse-echo mode on curved sections was demonstrated by testing on a 38 mm diameter steel rod. The transducer response was found to be broad band and highly non uniform but good pulse-echo performance was achieved at 5 MHz.


Assuntos
Desenho Assistido por Computador , Interpretação de Imagem Assistida por Computador/métodos , Modelos Teóricos , Transdutores , Ultrassonografia/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Luz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...