Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
3.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1041-1042: 1-10, 2017 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-27992785

RESUMO

This paper describes cases of poisoning caused by new psychoactive substances such as: 25B-NBOMe (2-(4-bromo-2,5-dimethoxyphenyl)-N-[(2-methoxyphenyl)methyl]ethanamine) and 4-CMC (1-(4-chlorophenyl)-2-(methylamino)-1-propanone). The analytical procedure includes rapid and selective method for the extraction and determination of 4-CMC and 25B-NBOMe in blood samples using UPLC-MS/MS technique. To the best of our knowledge, this is the first report, that involves a fully validated method for quantification of new-designer drug - 4-CMC in postmortem blood samples. The biological material was also analyzed with the use of routine analytical methods: immunochemical techniques, gas chromatography with flame ionization detection and gas chromatography with electron impact mass spectrometry. The results of real samples analyses correspond to possible toxicological effects: death resulting from 25B-NBOMe - mediated hallucinations (661ng/mL of 25B-NBOMe and 0.887ng/mL of 4-CMC), fatal overdose of 25B-NBOMe and 4-CMC (66.5ng/mL of 25B-NBOMe and 2.14ng/mL of 4-CMC) and non-fatal intoxication of these drugs (38.4ng/mL of 25B NBOMe and 0.181ng/mL of 4-CMC). Additionally, O-demethylathed O, O-bis-demethylathed and glucuronidated metabolites of 25B-NBOMe in biological specimens were detected.


Assuntos
Anisóis/sangue , Cromatografia Líquida de Alta Pressão/métodos , Drogas Desenhadas/análise , Fenetilaminas/sangue , Psicotrópicos/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Anal Bioanal Chem ; 408(3): 1009-13, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26635019

RESUMO

Determination of trace amounts of bisphenol A (BPA) may cause problems mainly related to the presence of BPA in solvents (even in LC-MS grade), laboratory vessels, and plastic equipment used for sample preparation. Variable and sometimes significant amounts of BPA present in the background cause problems in obtaining good repeatability of measurements at the ultra-trace levels. Such observations (i.e., poor repeatability of results) were made during development of the LC-MS/MS method for determination of BPA in human serum samples. The method included gradient separation of the sample's constituents. The BPA peak was present in the chromatograms not only when procedural blanks were injected but also when void injections were made. One of the possible ways to eliminate background contamination is to change the source of solvents, use a different water purification system, and introduce rigorous equipment cleaning procedures. However, despite the use of these recommended guidelines, the peak of BPA was still present in the system blank. It was observed that the intensity of the BPA peak was proportional to the time of column conditioning. It was concluded that BPA, present in the components of the mobile phase, is being enriched in the front of the separation column during its conditioning (i.e., when mobile phase elution strength was low). This paper describes effects of gradient and isocratic elution conditions on LC-MS/MS system blank. The problem of spurious BPA peak, originating from the mobile phase, was solved by replacing gradient with isocratic elution mode. The use of isocratic elution conditions with the mobile phase of relatively high elution strength (50% of acetonitrile) allowed elimination of the peak of BPA coming from the mobile phase and significantly improved the precision of determination of BPA at low concentration levels.


Assuntos
Compostos Benzidrílicos/análise , Cromatografia Líquida/métodos , Fenóis/análise , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/instrumentação , Sensibilidade e Especificidade , Espectrometria de Massas em Tandem/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...