Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Respir Med ; 218: 107395, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37633422

RESUMO

INTRODUCTION: Activity monitors (apps and wearables) are increasingly used by the general population, including people with Chronic Obstructive Pulmonary Disease (COPD). There is potential for activity monitors to support increases in physical activity for people with COPD and healthcare practitioners (HCPs) are likely to be key in supporting their use, but little is currently known about HCPs' views or experiences. This qualitative research aimed to explore HCPs' views and experiences of supporting people with COPD who have used activity monitors. METHODS: Seventeen semi-structured telephone or online interviews were conducted with HCPs between September 2020 and May 2021. HCPs included two nurses, an occupational therapist, a physician, and 13 physiotherapists. Participants were recruited via social media advertisements. They all had experience of supporting people with COPD who had used activity monitors. Interviews were analysed using reflexive thematic analysis. FINDINGS: Four themes were developed highlighting the challenges and benefits of HCPs supporting patients with using activity monitors and utilising patient-collected activity data; 1) Skills and experience are needed to increase accessibility and engagement, 2) Objectively monitored physical activity can support exercise prescription, 3) Applications of activity monitors vary across different settings, and 4) Support is needed for future use of activity monitors. DISCUSSION: HCPs recognised the potential for activity monitors to impact patients' ability to self-manage their COPD. However, there is a lack of guidance and information to support integration within practice. Future research is needed to co-develop information and guidelines for people with COPD and HCPs.


Assuntos
Médicos , Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/terapia , Atitude do Pessoal de Saúde , Exercício Físico , Terapia por Exercício , Pesquisa Qualitativa
2.
J Mater Sci Mater Med ; 33(6): 51, 2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35639212

RESUMO

Hand tendon injuries represent a major clinical problem and might dramatically diminish a patient's life quality. In this study, a targeted solution for flexor tendon repair was developed by combining a mechanical and biological approach. To this end, a novel acrylate-endcapped urethane-based polymer (AUP) was synthesized and its physico-chemical properties were characterized. Next, tubular repair constructs were developed using electrospinning of the AUP material with incorporated naproxen and hyaluronic acid (i.e. anti-inflammatory and anti-adhesion compounds, respectively), and with a tubular braid as mechanical reinforcement. Tensile testing of the repair constructs using ex vivo sheep tendons showed that the developed repair constructs fulfilled the required mechanical properties for tendon repair (i.e. minimal ultimate stress of 4 MPa), with an ultimate stress of 6.4 ± 0.6 MPa. Moreover, in vitro biological assays showed that the developed repair tubes and the incorporated bioactive components were non-cytotoxic. In addition, when equine tenocytes and mesenchymal stem cells were co-cultured with the repair tubes, an increased production of collagen and non-collagenous proteins was observed. In conclusion, this novel construct in which a mechanical approach (fulfilling the required mechanical properties) was combined with a biological approach (incorporation of bioactive compounds), shows potential as flexor tendon repair application. Graphical abstract.


Assuntos
Células-Tronco Mesenquimais , Procedimentos de Cirurgia Plástica , Traumatismos dos Tendões , Animais , Cavalos , Ovinos , Traumatismos dos Tendões/cirurgia , Tendões , Engenharia Tecidual
3.
COPD ; 19(1): 88-98, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35132933

RESUMO

Physical activity monitoring technology (e.g. smartphone apps or wearables) can objectively record physical activity levels, potentially support interventions to increase activity levels, and support the self-management of Chronic Obstructive Pulmonary Disease (COPD). Insight into patients' experiences of monitoring physical activity is needed to inform future healthcare practice and policy utilizing this technology to support long-term positive health behavior change. This scoping review aimed to explore the experiences of using technology for monitoring physical activity among people with COPD. The Joanna Briggs Institute scoping review methodological framework was used. Relevant scientific databases (CINAHL Complete, MEDLINE, PsycINFO, SPORTDiscus, Cochrane Library and Scopus) were searched from 1st January 2016 to 16th March 2021. Thematic synthesis was used to analyze the data. Twelve studies exploring the experiences of people with COPD using technology for monitoring physical activity were included in the synthesis. Seven themes were developed and summarize experiences: 1) Monitoring and keeping track of their activity and health, 2) Supporting motivation to be active, 3) Acceptability of the device, 4) Experiencing technical issues with the device, 5) Setting appropriate and achievable goals for their health condition, 6) Integrating the device into their life and daily routine, and 7) Perceived physical and psychological benefits of using the device. Further high-quality research is needed to understand the experiences of people with COPD using technology to monitor physical activity in everyday life and better self-manage their health condition. Supporting people with COPD to monitor their physical activity could enable them to better self-manage their health condition.


Assuntos
Aplicativos Móveis , Doença Pulmonar Obstrutiva Crônica , Autogestão , Exercício Físico , Monitores de Aptidão Física , Humanos , Doença Pulmonar Obstrutiva Crônica/terapia
4.
Int Orthop ; 45(1): 209-216, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33185725

RESUMO

PURPOSE: Scapular stress fracture (sSF) is a difficult complication to treat after reverse total shoulder arthroplasty (RSA). The aim of this study was to identify the prevalence and possible risk factors in a large population. METHODS: A total of 2165 RSAs that were implanted between January 2006 and October 2017 in five hospitals were evaluated. Within this cohort, sSF was radiologically confirmed. Age, gender, surgical indication and hospital of treatment were determined for the entire cohort. A matched 3:1 case-control study was then performed to investigate several clinical and surgical variables. RESULTS: sSF occurred in 3.1% (63 patients), with a median time interval of five months post-operative [IQR = 9, range: (1-79)]. Within the entire cohort, females (OR = 2.99) and rotator cuff arthropathy (RCA) (OR = 2.79) were more prone to this complication. Age had little influence (OR = 1.03). After exclusion, fifty-five eligible cases were matched to 165 controls based on hospital, gender, age and surgical indication. After univariable analysis, significance was obtained for osteopenia (P = 0.037), osteoporosis (P = 0.032), surgical approach (P = 0.002) and peri-operative acromioclavicular (AC) joint surgery (P = 0.035). Multivariate analysis demonstrated that osteopenia (OR = 3.94), osteoporosis (OR = 2.85) and a deltopectoral approach (OR = 3.70) were independent risk factors. CONCLUSION: According to our findings, older women with poor bone quality and a history of RCA suffered more frequently from sSF. Anterolateral approach during surgery was a surgical protective factor, possibly due to the mobilization of the acromioclavicular joint. Although this study indicates who is at risk for sSF, further investigation for prevention of sSF in these patients is necessary.


Assuntos
Artroplastia do Ombro , Fraturas de Estresse , Articulação do Ombro , Idoso , Artroplastia do Ombro/efeitos adversos , Estudos de Casos e Controles , Feminino , Humanos , Prevalência , Estudos Retrospectivos , Fatores de Risco , Escápula/diagnóstico por imagem , Escápula/cirurgia , Articulação do Ombro/diagnóstico por imagem , Articulação do Ombro/cirurgia , Resultado do Tratamento
5.
Acta Orthop Belg ; 86(2): 205-215, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33418608

RESUMO

The purpose of this survey in Belgium and the Netherlands was to assess treatment variation in glenohumeral osteoarthritis between experienced and less experienced orthopedic surgeons, and to investigate perioperative treatment after shoulder arthroplasty in a large group of orthopedic surgeons. Orthopedic surgeons specialized in shoulder surgery were invited to complete a survey between November 2013 and February 2015. Seventy-one percent of the approached surgeons com-pleted the survey. Less experienced surgeons (< 6 years) and surgeons from the Netherlands find patient characteristics (e.g. smoking p=0.01) more relevant than more experienced surgeons (≥ 6 years) and surgeons from Belgium. Less experienced surgeons will less likely (p=0.001) perform resurfacing arthroplasty compare to experienced surgeons. The less and the experienced surgeons use similar indications for a reverse shoulder arthroplasty regarding age limit and cuff arthropathy without osteoarthritis. Less experienced surgeon will more likely (p=0.003) prescribe a low molecular weight heparin during the hospital stay after a shoulder arthroplasty. In this survey, we found a decrease in the use of resurfacing arthroplasty and a strong increase in the use of reverse shoulder arthroplasty. Besides, there is little consensus concerning pre-operative planning, patient characteristics, surgical technique, and patient reported outcome measures. Level of evidence: IV.


Assuntos
Artroplastia do Ombro , Cirurgiões Ortopédicos , Osteoartrite , Assistência Perioperatória/métodos , Complicações Pós-Operatórias , Articulação do Ombro , Idoso , Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Artroplastia do Ombro/estatística & dados numéricos , Bélgica/epidemiologia , Competência Clínica , Feminino , Pesquisas sobre Atenção à Saúde , Humanos , Masculino , Países Baixos/epidemiologia , Cirurgiões Ortopédicos/normas , Cirurgiões Ortopédicos/estatística & dados numéricos , Osteoartrite/diagnóstico , Osteoartrite/epidemiologia , Osteoartrite/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Padrões de Prática Médica/estatística & dados numéricos , Articulação do Ombro/patologia , Articulação do Ombro/cirurgia
6.
Sci Rep ; 8(1): 4720, 2018 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-29549270

RESUMO

Insufficient glenoid fixation is one of the main reasons for failure in total shoulder arthroplasty. This is predominantly caused by the inert nature of the ultra-high molecular weight polyethylene (UHMWPE) used in the glenoid component of the implant, which makes it difficult to adhesively bind to bone cement or bone. Previous studies have shown that this adhesion can be ameliorated by changing the surface chemistry using plasma technology. An atmospheric pressure plasma jet is used to treat UHMWPE substrates and to modify their surface chemistry. The modifications are investigated using several surface analysis techniques. The adhesion with bone cement is assessed using pull-out tests while osteoblast adhesion and proliferation is also tested making use of several cell viability assays. Additionally, the treated samples are put in simulated body fluid and the resulting calcium phosphate (CaP) deposition is evaluated as a measure of the in vitro bioactivity of the samples. The results show that the plasma modifications result in incorporation of oxygen in the surface, which leads to a significant improved adhesion to bone cement, an enhanced osteoblast proliferation and a more pronounced CaP deposition. The plasma-treated surfaces are therefore promising to act as a shoulder implant.


Assuntos
Pressão Atmosférica , Cimentos Ósseos/química , Adesão Celular , Osteoblastos/citologia , Gases em Plasma/química , Polietilenos/química , Articulação do Ombro/cirurgia , Humanos , Teste de Materiais , Próteses e Implantes , Propriedades de Superfície
7.
J Intellect Disabil Res ; 62(12): 1058-1071, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29417652

RESUMO

BACKGROUND: Individuals with tuberous sclerosis complex (TSC) are at increased risk of developing self-injurious behaviour. The persistence of this deleterious behaviour over years is reported in aetiologically heterogeneous samples to be between 60% and 80% but is unknown for TSC. METHOD: In this study, we determined the 3-year persistence of self-injury in a sample (n = 52) of children (with and without ID) and adults (with ID) with TSC and examined characteristics associated with persistence. RESULTS: Findings for self-injury were contrasted to those for aggression and property destruction to examine the specificity of results to this behaviour. Self-injury was persistent in 84.6% of those with TSC who showed this behaviour, in contrast to 66.7% both for aggression and destruction. Persistent self-injury was associated with poor self-help skills, greater overactivity/impulsivity and more behavioural indicators of pain. These latter two characteristics were also associated with persistent aggression. No characteristics were associated with persistence of property destruction. CONCLUSION: These findings suggest that self-injurious behaviours in individuals with TSC, together with aggressive and destructive behaviours, are highly persistent and would benefit from targeted intervention. Poor adaptive skills, overactivity/impulsivity and painful health conditions may differentiate those at most risk for persistent self-injury or aggression.


Assuntos
Agressão/psicologia , Deficiência Intelectual/epidemiologia , Comportamento Problema/psicologia , Comportamento Autodestrutivo/epidemiologia , Esclerose Tuberosa/epidemiologia , Adolescente , Adulto , Comorbidade , Feminino , Humanos , Deficiência Intelectual/psicologia , Masculino , Comportamento Autodestrutivo/psicologia , Esclerose Tuberosa/psicologia , Reino Unido/epidemiologia , Adulto Jovem
8.
Sci Justice ; 57(1): 13-20, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28063580

RESUMO

Recent years have seen a significant increase in the sensitivity of DNA testing, enabling the determination of DNA profiles from low levels of cellular material. However, the increased sensitivity is in many ways a double-edged sword as background contaminating DNA generated during the manufacture of consumables and sampling devices is now being detected and may compromise the interpretation of the DNA profile results. This study initially demonstrated the effectiveness of ethylene oxide (EO) as a post-production treatment to eliminate DNA on swabs, used as a sampling device for the recovery of cellular material. Subsequently, the potential adverse effects of any residual EO remaining on the swabs on the downstream DNA analysis on both rayon and cotton swabs were investigated and the levels of remaining EO measured. Two main variables were tested: the amount of time elapsed since EO treatment of the swabs prior to use, and the time elapsed between cellular material collection and DNA analysis. Residual levels of EO were found to be below quantitation levels and therefore also international standards. The results indicated that while there was a negligible effect of EO treatment on DNA recovered from rayon swabs, there was however an adverse effect on the DNA profiles recovered from cotton swabs. The adverse effect was negatively correlated with time since EO treatment and positively correlated with time to DNA analysis.


Assuntos
Impressões Digitais de DNA , Desinfetantes , Contaminação de Equipamentos , Óxido de Etileno , Manejo de Espécimes/instrumentação , DNA/isolamento & purificação , Humanos
9.
J Orthop ; 14(1): 62-67, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27822004

RESUMO

This study introduced the new delto-fulcral triangle (DFT), the first anatomical model of its kind. As seen from the orthopaedician's supraspinatus-outlet view, the antero-superior point of the coracoid process along with the lateral- and posterior-most acromial landmarks form the boundaries of the DFT. Since these osseous scapular landmarks accounted for both dynamic and static stabilisers of the glenohumeral joint, knowledge of the anatomical features of the DFT may prove beneficial to the orthopaedic surgeon. This study thus aimed to investigate the morphometry of the new DFT. The bony surfaces of one-hundred and sixty-nine (n = 169) normal and pathological (Omarthrosis and Cuff-Tear Arthropathy) shoulders from the hospital's CT scan database were reconstructed (Mimics®: Materialise, Leuven, Belgium). Statistical significance was observed between all three groups for Side 2 (LACPF: distance between most lateral and most posterior points of the acromion) and angles α (angle between sides 1 and 3) and ß (angle between sides 1 and 2) of the DFT. It was postulated that although pathological cases present with a smaller lateral acromial distance (LACPF), their lateral acromion landmark is more posteriorly placed from the scapular plane than that of a normal case. As the aspects of the morphometric anatomy of the DFT presented with levels of statistical significance, it may provide a means to evaluate the anatomy of normal and pathological cases. Additionally, the three osseous scapular landmarks that create the DFT are clearly visualised and palpable, therefore they are easily reproducible from both X-ray images and CT scans.

10.
Acta Orthop Belg ; 82(2): 339-345, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27682297

RESUMO

We evaluate our experience with arthroscopic interpositioning arthroplasty as a treatment of the young degenerative shoulder joint. Between 2007 and 2009 ten patients were treated with either a dermal allograft or a meniscal allograft. In seven patients the graft failed and within 13 months these were revised to a total shoulder arthroplasty. Three patients are still satisfied after 7 to 8 years follow-up. Biologic resurfacing of the glenoid may have a role in the management of glenohumeral arthritis in the young and active patient, but the optimal graft and pathology still need to be defined.


Assuntos
Artroplastia/métodos , Osteoartrite/cirurgia , Articulação do Ombro/cirurgia , Adulto , Aloenxertos , Desbridamento , Feminino , Humanos , Masculino , Meniscos Tibiais/transplante , Pessoa de Meia-Idade , Osteoartrite/diagnóstico por imagem , Estudos Prospectivos , Radiografia , Articulação do Ombro/diagnóstico por imagem , Transplante de Pele , Adulto Jovem
11.
Bone Joint J ; 98-B(9): 1215-21, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27587523

RESUMO

AIMS: Heterotopic ossification (HO) occurs after arthroplasty, especially total hip arthroplasty. In this study we describe the incidence, evolution, morphology and clinical consequences of HO following reverse shoulder arthroplasty. PATIENTS AND METHODS: This is a single-centre retrospective study of 132 consecutive patients who received a Delta III or Delta Xtend reverse total shoulder arthroplasty between 2006 and 2013 for the treatment of cuff tear arthropathy. There were 96 women and 36 men. Their mean age at the time of surgery was 69 years (49 to 89) and the mean follow-up was 36 months (12 to 84). The incidence, evolution, morphology and clinical consequences of HO using the Constant-Murley score (CS) were analysed. A modified Brooker classification of HO of the hip was used. RESULTS: HO was seen in 39 patients (29.5%). A total of 31 of these patients (81.6%) began to develop HO by three months post-operatively. According to the Hamada classification, 11 patients had grade 1a, eight had grade 1b, six had grade 1c and 14 had grade 2 HO. The HO evolved over a mean of 8.3 months (3 to 21). Patients with HO had a lower mean CS at three (p = 0.017), six (p < 0.001) and 12 months (p < 0.001) post-operatively. HO was not associated with notching (p = 0.675). CONCLUSION: HO after reverse shoulder arthroplasty is a non-progressive condition without long-term clinical consequences. Only grade 2 HO is clinically relevant with a negative effect on the function of the shoulder during its development. Cite this article: Bone Joint J 2016;98-B:1215-21.


Assuntos
Artroplastia do Ombro/efeitos adversos , Artroplastia do Ombro/métodos , Ossificação Heterotópica/etiologia , Distribuição por Idade , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ossificação Heterotópica/epidemiologia , Ossificação Heterotópica/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de Doença , Distribuição por Sexo
12.
Expert Rev Med Devices ; 13(8): 773-84, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27410191

RESUMO

INTRODUCTION: There is a lack of organization in existing studies on the outcome and complications of total shoulder arthroplasty. As a result, it is difficult to gain substantial evidence regarding the rate and risk factors for the occurrence of glenoid loosening which remains the most common cause of prosthetic failure. To improve the quality of future studies, an agreement should exist on definitions of glenoid loosening and on the potential risk factors. AREAS COVERED: Reviewing the literature, loosening can be defined as the appearance of radiolucent lines, radiological loosening, clinical loosening and revision as the end stage. Three different categories of influencing parameters can be distinguished: implant related, patient related and surgeon related. Expert commentary: The aim of this review is to organize the available knowledge on glenoid failure, as well as to describe the gaps so that it will constructively contribute to the debate on how to prevent glenoid failure in the anatomic total shoulder arthroplasty.


Assuntos
Cavidade Glenoide/patologia , Falha de Prótese , Artroplastia de Substituição , Cavidade Glenoide/diagnóstico por imagem , Cavidade Glenoide/cirurgia , Humanos , Imageamento Tridimensional , Desenho de Prótese
13.
Acta Orthop Belg ; 82(3): 637-642, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29119907

RESUMO

Chronic glenohumeral dislocation is a rare entity and several treatment options have been proposed. The aim of this study is to report the long-term follow-up of the reversed shoulder arthroplasty in patients with chronic glenohumeral dislocation. A retrospective analysis of all patients between January 2002 and December 2012 that were treated with a reversed shoulder arthroplasty for chronic anterior glenohumeral dislocations was performed. Pre-operative CT evaluation of the bone loss and fatty degeneration of the rotator cuff muscles was performed. Pre- and postoperative Constant-Murley score was evaluated. 6 patients (4 males and 2 females) with anterior glenohumeral dislocations were evaluated. Average age was 73 years (between 65-86 years). The average time of dislocation was 18 weeks (between 4 and 52 weeks). Average time of follow-up was 39 months (between 12 and 90 months). The CM improved from 33 (between 17 and 45) pre-op to 76 postop (between 55 and 89). No postoperative complications were observed. Reversed shoulder arthroplasty gives good results in case of chronic glenohumeral dislocation.


Assuntos
Artroplastia do Ombro/métodos , Luxação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Doença Crônica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Rep Prog Phys ; 77(4): 046502, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24695004

RESUMO

Fe-based superconductors bridge a gap between MgB2 and the cuprate high temperature superconductors as they exhibit multiband character and transition temperatures up to around 55 K. Investigating Fe-based superconductors thus promises answers to fundamental questions concerning the Cooper pairing mechanism, competition between magnetic and superconducting phases, and a wide variety of electronic correlation effects. The question addressed in this review is, however, is this new class of superconductors also a promising candidate for technical applications? Superconducting film-based technologies range from high-current and high-field applications for energy production and storage to sensor development for communication and security issues and have to meet relevant needs of today's society and that of the future. In this review we will highlight and discuss selected key issues for Fe-based superconducting thin film applications. We initially focus our discussion on the understanding of physical properties and actual problems in film fabrication based on a comparison of different observations made in the last few years. Subsequently we address the potential for technological applications according to the current situation.

15.
Acta Orthop Belg ; 80(3): 301-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26280602

RESUMO

Hardware prominence after plate fixation for clavicle fracture is a common complication. The aim of the study was to perform a 3D analysis of the prominence of different types of superior clavicle plates. An automated fitting of 3 straight and 10 precontoured plates was performed on 52 3D-CT-scan reconstructed cadaver clavicles. The mean and maximum bone-plate distance and maximum prominence was significant higher with the straight plates compared to the precontoured plates. The mean and maximum boneplate distance was significant higher with the precontoured DePuy-Synthes plates compared to the precontoured Acumed plates but when evaluating the maximum prominence there was no significant difference between the most commonly used 8-holes plates. To conclude, precontoured plates of the clavicula diminish significantly hardware prominence. There exists a difference in hardware prominence between different brands of precontoured plates but this difference is limited and in most cases not significant.


Assuntos
Placas Ósseas , Clavícula/cirurgia , Fraturas Ósseas/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Cadáver , Clavícula/diagnóstico por imagem , Clavícula/lesões , Feminino , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Ajuste de Prótese , Tomografia Computadorizada por Raios X
16.
Acta Orthop Belg ; 80(3): 314-21, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26280604

RESUMO

UNLABELLED: Reversed total shoulder arthroplasty (RTSA) has well known indications and good to excellent results are described in the literature. When the arthroplasty fails however, revision remains a technical challenge with many questions unanswered. To analyse retrospectively and consecutively the indications and results of primary RTSA-revision. All patients that underwent revision RTSA between 2004 and 2009 were included. Indications for surgery, surgical details and clinical evaluation with the preand postoperative Constant-score (CS) were analyzed. 37 Revisions (37 patients) of RTSA were analysed with an average follow up of 41.2 months (24-84). Indications were infection (23), glenoid loosening (9), instability (2) malpositioning (2) and suprascapular nerve irritation (1). 25 patients obtained a one-stage conversion to a new reversed prosthesis; 4 patients obtained a two-stage revision; 8 patients got a megahead prosthesis. No difference in reinfection rate is seen between one- and two stage techniques. An overall lower CS is seen for the mega-head prosthesis. CONCLUSIONS: The main indication for revision was infection. Revision of RTSA to a new reversed prosthesis is to prefer even when several procedures are necessary in one patient. When this is impossible, a mega-head prosthesis is to consider and gives reasonable results.


Assuntos
Artroplastia de Substituição/métodos , Instabilidade Articular/cirurgia , Prótese Articular , Falha de Prótese , Infecções Relacionadas à Prótese/cirurgia , Articulação do Ombro/cirurgia , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
17.
J Bone Joint Surg Br ; 92(6): 817-22, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20513879

RESUMO

We retrospectively reviewed 11 consecutive patients with an infected reverse shoulder prosthesis. Patients were assessed clinically and radiologically, and standard laboratory tests were carried out. Peroperative samples showed Propionbacterium acnes in seven, coagulase-negative Staphylococcus in five, methicillin-resistant staphylococcus aureus in one and Escherichia coli in one. Two multibacterial and nine monobacterial infections were seen. Post-operatively, patients were treated with intravenous cefazolin for at least three days and in all antibiotic therapy was given for at least three months. Severe pain (3 of 11) or severe limitation of function (3 of 11) are not necessarily seen. A fistula was present in eight, but function was not affected. All but one patient were considered free of infection after one-stage revision at a median follow-up of 24 months, and without antibiotic treatment for a minimum of six months. One patient had a persistent infection despite a second staged revision, but is now free of infection with a spacer. Complications included posterior dislocation in one, haematoma in one and a clavicular fracture in one. At the most recent follow-up the median post-operative Constant-Murley score was 55, 6% adjusted for age, gender and dominance. A one-stage revision arthroplasty reduces the cost and duration of treatment. It is reliable in eradicating infection and good functional outcomes can be achieved.


Assuntos
Artroplastia de Substituição/métodos , Prótese Articular/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Articulação do Ombro/cirurgia , Adulto , Idoso , Antibacterianos/uso terapêutico , Artroplastia de Substituição/reabilitação , Doença Crônica , Terapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/tratamento farmacológico , Reoperação/métodos , Estudos Retrospectivos , Resultado do Tratamento
18.
J Phys Chem B ; 110(47): 23688-93, 2006 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-17125328

RESUMO

Au nanoparticles supported on Al2O3 were prepared by deposition-precipitation of HAuCl4 with different precipitation agents NaOH and urea. The samples were investigated by means of different characterization techniques such as X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XAS), and transmission electron microscopy (TEM). The results show that depending on the precipitation agent, the Au particles have a different Au-Au coordination number and size after calcination at 523 K. Whereas the use of NaOH leads to the formation of Au nanoparticles with a Au-Au coordination number of 6.7 and a mean diameter below 2 nm, those prepared with urea have a mean size of 3.1 nm. The Au-Au coordination number could be determined as 8.6. At the smaller particles obtained with NaOH, hints for Au-O interactions were found. For these particles TEM results advise a rather flat lenticular morphology. Different deposition mechanisms depending on the precipitation agent are discussed as the reason for the formation of nanoparticles with different shapes, sizes, and valence states.

19.
J Orthop Res ; 22(6): 1222-30, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15475201

RESUMO

UNLABELLED: Painful cuff tear arthropathy (CTA) affects the independence of the elderly. Surgical treatment often consists of joint replacement, the functional outcome of which remains variable. Knowledge of the biomechanical properties of the different prosthetic designs can guide the orthopaedic surgeon in the choice of implant to predict its clinical result. A 3-D computer model of the glenohumeral joint is used to analyse the moment of the deltoid muscle in the scapular plane. A geometrical 3-D ball-and-socket model of the shoulder joint was used to calculate (1) the angle-force relationships, (2) the moment arm of the deltoid muscle and (3) the moment of the deltoid muscle components, for increasing degrees of arm elevation in the scapular plane. In this 3-D model, a clinical thoraco-scapular rhythm analysis was implemented, based on measurements in normal subjects, patients treated with an anatomical prosthesis and patients treated with an inversed delta III prosthesis. These data were compared for 10 different prosthetic treatment options. RESULTS: Muscle angle-force curves show a favourable slope in non-anatomical prosthetic designs, where the centre of rotation of the glenohumeral joint is medialized, the deltoid muscle is elongated and the humeral shaft is lateralized. On the contrary, anatomical prosthetic designs do not perform well in this computer analysis. CONCLUSIONS: From a biomechanical point of view, a shoulder prosthesis which medializes the centre of rotation, lengthens the deltoid muscle and increases the deltoid lever arm, results in a significantly more powerful abduction of the shoulder, despite complete loss of rotator cuff function. RELEVANCE: This study explains why a successful functional outcome can be expected in CTA with a reversed prosthesis.


Assuntos
Simulação por Computador , Próteses e Implantes , Lesões do Manguito Rotador , Manguito Rotador/fisiologia , Articulação do Ombro/fisiologia , Artroplastia de Substituição , Fenômenos Biomecânicos , Humanos , Desenho de Prótese , Rotação , Manguito Rotador/cirurgia , Escápula/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...