Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Med Biol ; 58(14): 4717-31, 2013 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-23780474

RESUMO

A method is described for computing patient-specific absorbed dose rates to active marrow which accounts for spatial variation in bone volume fraction and marrow cellularity. A module has been added to the 3D Monte Carlo dosimetry program DPM to treat energy deposition in the components of bone spongiosa distinctly. Homogeneous voxels in regions containing bone spongiosa (as defined on CT images) are assumed to be comprised only of bone, active (red) marrow and inactive (yellow) marrow. Cellularities are determined from biopsy, and bone volume fractions are computed from cellularities and CT-derived voxel densities. Electrons are assumed to deposit energy locally in the three constituent components in proportions determined by electron energy absorption fractions which depend on energy, cellularity, and bone volume fraction, and which are either taken from the literature or are derived from Monte Carlo simulations using EGS5. Separate algorithms are used to model primary ß particles and secondary electrons generated after photon interactions. Treating energy deposition distinctly in bone spongiosa constituents leads to marrow dosimetry results which differ from homogeneous spongiosa dosimetry by up to 20%. Dose rates in active marrow regions with cellularities of 20, 50, and 80% can vary by up to 20%, and can differ by up to 10% as a function of bone volume fraction. Dose to bone marrow exhibits a strong dependence on marrow cellularity and a potentially significant dependence on bone volume fraction.


Assuntos
Medula Óssea/patologia , Medula Óssea/efeitos da radiação , Osso e Ossos/efeitos da radiação , Método de Monte Carlo , Radioimunoterapia/métodos , Medula Óssea/diagnóstico por imagem , Osso e Ossos/diagnóstico por imagem , Humanos , Radiometria , Tomografia Computadorizada por Raios X
2.
IEEE Trans Nucl Sci ; 54(1): 146-151, 2007 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-20305792

RESUMO

The DPM (Dose Planning Method) Monte Carlo electron and photon transport program, designed for fast computation of radiation absorbed dose in external beam radiotherapy, has been adapted to the calculation of absorbed dose in patient-specific internal emitter therapy. Because both its photon and electron transport mechanics algorithms have been optimized for fast computation in 3D voxelized geometries (in particular, those derived from CT scans), DPM is perfectly suited for performing patient-specific absorbed dose calculations in internal emitter therapy. In the updated version of DPM developed for the current work, the necessary inputs are a patient CT image, a registered SPECT image, and any number of registered masks defining regions of interest. DPM has been benchmarked for internal emitter therapy applications by comparing computed absorption fractions for a variety of organs using a Zubal phantom with reference results from the Medical Internal Radionuclide Dose (MIRD) Committee standards. In addition, the ß decay source algorithm and the photon tracking algorithm of DPM have been further benchmarked by comparison to experimental data. This paper presents a description of the program, the results of the benchmark studies, and some sample computations using patient data from radioimmunotherapy studies using (131)I.

3.
Phys Med Biol ; 45(8): 2263-91, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10958194

RESUMO

A new Monte Carlo (MC) algorithm, the 'dose planning method' (DPM), and its associated computer program for simulating the transport of electrons and photons in radiotherapy class problems employing primary electron beams, is presented. DPM is intended to be a high accuracy MC alternative to the current generation of treatment planning codes which rely on analytical algorithms based on an approximate solution of the photon/electron Boltzmann transport equation. For primary electron beams, DPM is capable of computing 3D dose distributions (in 1 mm3 voxels) which agree to within 1% in dose maximum with widely used and exhaustively benchmarked general-purpose public-domain MC codes in only a fraction of the CPU time. A representative problem, the simulation of 1 million 10 MeV electrons impinging upon a water phantom of 128(3) voxels of 1 mm on a side, can be performed by DPM in roughly 3 min on a modern desktop workstation. DPM achieves this performance by employing transport mechanics and electron multiple scattering distribution functions which have been derived to permit long transport steps (of the order of 5 mm) which can cross heterogeneity boundaries. The underlying algorithm is a 'mixed' class simulation scheme, with differential cross sections for hard inelastic collisions and bremsstrahlung events described in an approximate manner to simplify their sampling. The continuous energy loss approximation is employed for energy losses below some predefined thresholds, and photon transport (including Compton, photoelectric absorption and pair production) is simulated in an analogue manner. The delta-scattering method (Woodcock tracking) is adopted to minimize the computational costs of transporting photons across voxels.


Assuntos
Método de Monte Carlo , Fótons , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Algoritmos , Simulação por Computador , Elétrons , Imagens de Fantasmas , Espalhamento de Radiação
4.
Radiology ; 159(1): 39-42, 1986 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3513251

RESUMO

To evaluate its potential for differentiating benign from malignant breast lesions, digital subtraction angiography of the breast (DSAB) was performed in 23 women with mammographic evidence of disease, and the results were compared with surgical biopsy findings. The DSAB technique employed breast immobilization with modest compression and bolus injection; following the injection of contrast material, 30-40 sequential subtraction images were obtained over a 5-minute interval. The average technical settings were 50 k Vp and 10 mAs, resulting in an estimated radiation dose to the breast of 0.05 mrad (0.5 mu Gy) per exposure. DSAB consistently demonstrated retention of contrast material and abnormal vasculature in malignant lesions but not in benign lesions. In the 22 breast lesions for which there was histopathologic correlation, DSAB correctly categorized eight of nine malignant and 11 of 13 benign lesions. Although this series is small, the initial results of DSAB suggest its potential for differentiating benign from malignant lesions.


Assuntos
Angiografia , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Carcinoma/diagnóstico por imagem , Adenocarcinoma/diagnóstico por imagem , Diagnóstico Diferencial , Feminino , Humanos , Mamografia , Técnica de Subtração
5.
Cancer ; 56(6): 1287-92, 1985 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-3896454

RESUMO

The authors have investigated digital subtraction angiography (DSA) for the differential diagnosis of breast lesions detected initially by mammography. Eighteen patients scheduled for biopsy first underwent digital subtraction angiography of the breast (DSAB). Criteria for malignancy included the presence of abnormal vessels and a "blush" in the area of the lesion. A total of 17 lesions are currently available for histopathologic correlation. Although this is a small series, the initial results of DSAB suggest its potential utility for differentiating between benign and malignant lesions.


Assuntos
Angiografia , Doenças Mamárias/diagnóstico por imagem , Neoplasias da Mama/diagnóstico por imagem , Técnica de Subtração , Diagnóstico Diferencial , Estudos de Avaliação como Assunto , Feminino , Humanos
6.
Radiology ; 155(1): 65-8, 1985 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-3883425

RESUMO

Differentiation of benign from malignant lesions in screening for breast cancer is usually arrived at via surgical biopsy, an invasive and costly procedure. Digital subtraction angiography (DSA) of the breast is a less invasive procedure. DSA imaging patterns from 22 patients with malignant and benign lesions were compared with surgical biopsy findings. DSA examinations were performed with the breast in an immobilization device and contrast medium was injected into the superior vena cava. Images were produced with a low kilovoltage (50 kVp) to enhance contrast, and a technique yielding an average dose to the breast of less than 2 rad (0.02 Gy) was used. Preliminary clinical results demonstrate the potential of DSA for differentiation of benign and malignant lesions and justify further investigations of its use as an alternative to surgical biopsy.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Angiografia/métodos , Biópsia , Mama/patologia , Neoplasias da Mama/irrigação sanguínea , Neoplasias da Mama/patologia , Feminino , Humanos , Doses de Radiação , Técnica de Subtração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...