Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
4.
Zentralbl Gynakol ; 102(12): 655-8, 1980.
Artigo em Alemão | MEDLINE | ID: mdl-7445821

RESUMO

Evaluation on the basis of Hodr's CTG score was undertaken of 1,239 antepartum cardiotocograms obtained from 1,239 pregnant women. Inconspicuous cardiotocograms were obtained from 1,114 patients, that is 89.9 per cent, while dubious or prepathological findings were recorded from 123 women (nine per cent) and clearly pathological cardiotocographic findings from two. Predictions were correct in 1,019 cases (82.4 per cent), falsely positive in 147 cases (11.8 per cent), and falsely negative in 71 cases (5.7 per cent).


Assuntos
Doenças Fetais/diagnóstico , Monitorização Fetal/métodos , Frequência Cardíaca , Adulto , Feminino , Sofrimento Fetal/diagnóstico , Humanos , Recém-Nascido , Gravidez , Complicações na Gravidez/diagnóstico
5.
Zentralbl Gynakol ; 102(1): 12-6, 1980.
Artigo em Alemão | MEDLINE | ID: mdl-7467919

RESUMO

The score proposed by Fischer and co-workers was used in evaluating 1,239 antepartal cardiotocograms which had been recorded from the same number of pregnant women. The cardiotocograms of 966 patients (78.0 per cent) were without pathological findings (between eight and ten scores on the condition index), while prepathological suspicion was recordable from 141 (11.4 per cent) (between five and seven scores), and pathological conditions from 132 (10.7 per cent) (between four and zero scores). Conditions of the newborn were correctly predicted in 913 cases (73.8 per cent), erroneously positive in 120 cases (9.7 per cent), and erroneously negative in 204 cases (16.5 per cent).


Assuntos
Coração Fetal/fisiologia , Frequência Cardíaca , Complicações na Gravidez/diagnóstico , Parto Obstétrico/métodos , Feminino , Humanos , Gravidez , Risco
6.
Zentralbl Gynakol ; 102(16): 909-14, 1980.
Artigo em Alemão | MEDLINE | ID: mdl-7456887

RESUMO

A total of 1,239 antepartum cardiotocograms, obtained from the same number of pregnant women, was evaluated on the basis of the CTG score proposed by Kubli. The cardiotocograms were unconspicuous, that is non-contributory, in the context of 752 patients (60.7 per cent), while 400 (32.3 per cent) gave rise to suspicion, and 87 (7.0 per cent) were pathological. Predictions were correct in 736 cases (59.5 per cent), falsely positive in 91 cases (7.4 per cent), and falsely negative in 410 cases (33.1 per cent).


Assuntos
Coração Fetal , Monitorização Fetal/métodos , Frequência Cardíaca , Feminino , Doenças Fetais/diagnóstico , Humanos , Gravidez , Complicações na Gravidez/diagnóstico
7.
Zentralbl Gynakol ; 101(9): 608-11, 1979.
Artigo em Alemão | MEDLINE | ID: mdl-484100

RESUMO

The efficiency of liquid crystals in placenta localisation was checked by comparison of thermographic results with those obtained from using the ultrasonic B-scan method. Ther results obtained from the two techniques were in fair agreement in 93 of 106 cases or 87.7 per cent. The highest amount of agreement was recorded from the group with anterior-wall placenta. For placenta localisation the sensitivity of liquid crystal thermography was found to be inferior to that of the ultrasonic B-scan method.


Assuntos
Placenta/anatomia & histologia , Termografia/normas , Feminino , Humanos , Gravidez , Ultrassom/normas
8.
Zentralbl Gynakol ; 101(24): 1572-5, 1979.
Artigo em Alemão | MEDLINE | ID: mdl-547609

RESUMO

One antepartal cardiotocogram each was taken from 1,239 pregnant women and evaluated by means of theCGT score, as proposed by Hammacher and co-workers. Inconspicuous cardiotocograms were recorded from 1,090 patients (88.0 per cent), while 124 (10.0 per cent) were suspicious, 20 (1.6 per cent) prepathological, and five (0.4 per cent) pathological. Forecasts of newborns' conditions were correct in 994 cases (80.4 per cent), erroneously positive in 140 cases (11.3 per cent), and erroneously negative in 103 cases (8.3 per cent).


Assuntos
Monitorização Fetal/métodos , Índice de Apgar , Feminino , Humanos , Recém-Nascido , Trabalho de Parto , Gravidez , Prognóstico
11.
Zentralbl Gynakol ; 100(13): 847-9, 1978.
Artigo em Alemão | MEDLINE | ID: mdl-685566

RESUMO

There is reported about 106 amniocenteses between 28th and 40th week of pregnancy after previous investigation and marking of the point of puncture on the abdomen of the pregnant woman by means of investigation the point with ultrasonic compoundscan. The angle of puncture method is found out and the maximum and minimum infiltration intensity. Complications have not been observed. That technique makes possible a high security for puncture and excellent puncture results.


Assuntos
Amniocentese/métodos , Ultrassonografia , Feminino , Humanos , Gravidez , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez
12.
Zentralbl Gynakol ; 100(18): 1193-200, 1978.
Artigo em Alemão | MEDLINE | ID: mdl-568862

RESUMO

Eighty-five cardiotachograms of newborns aged between 34 and 42 weeks of gestation were studied. Fifty newborns were delivered spontaneously. In seventeen cases caesarean sections were used and in eighteen cases vacuum extractions. Cardiotachograms were recorded continuously throughout the immediate postnatal period until the stabilisation of the heart rate. Cardiotachograms were divided into three typical groups based on their cours of heart rate and fluctuation. The relation between these groups and the methods and duration of delivery and the condition of newborns were discussed. We found a correlation between the pathological cardiotachograms (tachycardiac and bradycardiac type of cardiotachogram) and long expulsion time, existent history of intrauterine disorder and low Apgar score. No relationship could be established between pathological cardiotachograms and the method of delivery.


Assuntos
Arritmias Cardíacas/diagnóstico , Doenças do Recém-Nascido/diagnóstico , Monitorização Fisiológica , Cuidado Pós-Natal , Bradicardia/diagnóstico , Feminino , Frequência Cardíaca , Humanos , Recém-Nascido , Trabalho de Parto , Gravidez , Taquicardia/diagnóstico , Fatores de Tempo
13.
Zentralbl Gynakol ; 99(22): 1366-70, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-602505

RESUMO

Pregnant women with imminent miscarriage were treated with Partusisten and/or Dilatol for tocolysis beginning in the 29. week of pregnancy. During treatment the mean urinary excretion of total oestrogens (n = 35; p less than 0,01 in 36th week of pregnancy and later) and the mean plasma level of HPL increased (n = 8; p less than 0,01 in 33., 34. and 35. week of pregnancy). These changes have to be concidered in judging the fetoplacental unit or the function of placenta.


Assuntos
Estrogênios/urina , Etanolaminas/farmacologia , Fenoterol/farmacologia , Lactogênio Placentário/sangue , Ameaça de Aborto/prevenção & controle , Feminino , Fenoterol/uso terapêutico , Humanos , Gravidez , Fatores de Tempo
14.
Zentralbl Gynakol ; 99(22): 1371-6, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-602506

RESUMO

8 normotensive late pregnant women in the early latent phase of premature labor were examined before, during and after the intravenous pump infusion of fenoterol (Partusisten) with the method of quantitative sphygmometry, the bloodless graphic registration of the arterial blood pressure and the direct electronic timing of pulse wave velocity. Dose levels of fenoterol were 3 microgram/min and 6 microgram/min. During the administration of fenoterol systolic blood pressure increases insignificantly, but mean and diastolic pressure decrease distinctly with broadening of amplitude. Stroke volume, cardiac output, work and power of the heart increase significantly. The fall of the total peripheral resistance is much more pronounciated than the decrease of blood pressure. Therefore the hemodynamic mode of action of fenoterol is a favourable one in regard to the perfusion of peripheral tissues. The effects on the cardiovascular system in a dose level usual for tocolysis are smaller than those of nylidrin.


Assuntos
Sistema Cardiovascular/efeitos dos fármacos , Etanolaminas/farmacologia , Fenoterol/farmacologia , Hemodinâmica/efeitos dos fármacos , Pressão Sanguínea/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Gravidez , Pulso Arterial/efeitos dos fármacos
15.
Zentralbl Gynakol ; 99(21): 1299-304, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-339605

RESUMO

The amniocentesis to gain increasing importance ought to be examined whether an alteration of the bacterial flora of the amniotic fluid was caused by repeated amniocentesis. 128 samples of amniotic fluid selected by abdominal amniocentesis were placed in microbiological cultures. Bacteria was isolated in 30 cases, originated predominantly by pollution. Under the circumstance of strong sterile conditions the amniocentesis proven even when repeated a diagnostical way of procedure which does not represent any danger to mother nor child.


Assuntos
Amniocentese/efeitos adversos , Líquido Amniótico/microbiologia , Escherichia coli/isolamento & purificação , Feminino , Humanos , Klebsiella/isolamento & purificação , Gravidez , Complicações na Gravidez/diagnóstico , Proteus/isolamento & purificação , Staphylococcus/isolamento & purificação , Esterilização , Streptococcus/isolamento & purificação , Fatores de Tempo
16.
Zentralbl Gynakol ; 99(16): 985-91, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-919874

RESUMO

12 pregnant women in the gestational weeks 33 to 39 who had symptoms of chronic placental insufficiency received 22 intraamniotic amino acids infusions. 250 ml of a 5 per cent solution of L-amino-acids was infused within 12 hours. During these infusions nearly 80 per cent of the amino acids (according to alpha-amino-nitrogen) were eliminated from the amniotic fluid in 24 hours. The highest elimination rate with 83.4 per cent has been found in cases with intrauterine growth retardation. The smallest rise of urea-nitrogen-level after intraamniotic amino acid infusion has been observed in cases with intrauterine growth retardation and in the second or third infusion. The decrease of amniotic fluid protein content after infusion was on the average about 30 per cent. The interpretation of these results is difficult, because so far not exist examinations of the gastrointestinal resorption and metabolism of amino acids and amniotic fluid proteins by the human fetus. According to our experiences it is possible to supply fetus with severe intrauterine growth retardation with vital substrates on paraplacental way. But the postnatal treatment of the small for dates babies is more effective.


Assuntos
Aminoácidos/administração & dosagem , Âmnio , Doenças Placentárias/tratamento farmacológico , Insuficiência Placentária/tratamento farmacológico , Aminoácidos/metabolismo , Aminoácidos/uso terapêutico , Líquido Amniótico/metabolismo , Creatinina/metabolismo , Feminino , Humanos , Infusões Parenterais , Gravidez , Proteínas/metabolismo , Ureia/metabolismo
17.
Zentralbl Gynakol ; 99(18): 1120-3, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-919888

RESUMO

The cardiotocograms of 340 pregnant women which are recorded ante partum and intra partum were analysed by the score of Hammacher. This score is representative for the intra partum period. We found a direct relation between variations of CTG and the Apgar-score of newborn. In the ante partum period only in pathological score this correlation can be observed.


Assuntos
Trabalho de Parto , Gravidez , Contração Uterina , Índice de Apgar , Feminino , Humanos , Recém-Nascido , Métodos
18.
Zentralbl Gynakol ; 99(10): 603-9, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-899344

RESUMO

Cardiotachograms in a group of 30 vigorous newborns have permitted the study of the typical signs of the regulatory mechanism of neonatal circulation during the first minutes of life. Immediately after birth neonatal heart rate rise to a peak heart rate of 177 bpm at the age of two minutes. Thereupon neonatal heart rate falls gradually and reaches a stabil level in the 13. minute after delivery. In the phase of gradually fall in neonatal heart rate many brief episodes of cardiac deceleration ("spikes") were observed.


Assuntos
Frequência Cardíaca , Recém-Nascido , Monitorização Fisiológica/métodos , Feminino , Humanos , Gravidez
19.
Zentralbl Gynakol ; 99(3): 168-72, 1977.
Artigo em Alemão | MEDLINE | ID: mdl-899365

RESUMO

By means of quantitative sphygmometry and the unbloody recording of arterial blood pressure the hemodynamic effect of an infusion of Solcoseryl in combination with low molecular dextrane on the maternal cardiovascular system in 9 normotensive healthy late pregnant women is examined. Solcoseryl causes no improvement of the cardiovascular effects known for low molecular dextrane.


Assuntos
Actiemil/farmacologia , Dextranos/farmacologia , Hemodinâmica/efeitos dos fármacos , Gravidez , Extratos de Tecidos/farmacologia , Pressão Sanguínea/efeitos dos fármacos , Débito Cardíaco/efeitos dos fármacos , Volume Cardíaco/efeitos dos fármacos , Quimioterapia Combinada , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Terceiro Trimestre da Gravidez , Resistência Vascular/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...