Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine Deform ; 10(6): 1265-1278, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35904725

RESUMO

PURPOSE: To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. METHODS: A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies. RESULTS: Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt-chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°-55.42°] and Ti 32.58° [24.62°-40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°-29.53°] and Ti 20.15° [18.0°-22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7-22%) for CoCr and 12% (- 8-32%) for stainless steel (SS) (n = 2 studies each; Chi2 = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1-22%) for Ti (n = 3 studies) and 10% (2-19) for CoCr (n = 1 study). Among 6.0-6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°-14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°-40.62°), and pelvic tilt angle was 21.11° (18.35°-23.86°). CONCLUSIONS: For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided. LEVEL OF EVIDENCE: III.


Assuntos
Pseudoartrose , Fusão Vertebral , Adulto , Humanos , Fusão Vertebral/efeitos adversos , Aço Inoxidável , Titânio , Ligas de Cromo , Pseudoartrose/etiologia , Cobalto , Cromo
2.
Spine Deform ; 10(6): 1245-1263, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35737287

RESUMO

PURPOSE: To assess surgical and safety outcomes associated with different rod materials and diameters in adolescent idiopathic scoliosis (AIS) surgery. METHODS: A systematic literature review and meta-analysis evaluated the surgical management of AIS patients using pedicle screw fixation systems (i.e., posterior rods and pedicle screws) with rods of different materials and sizes. Postoperative surgical outcomes (e.g., kyphosis and coronal correction) and complications (i.e., hyper/hypo-lumbar lordosis, proximal junctional kyphosis, revisions, reoperations, and infections) were assessed. Random-effects models (REMs) pooled data for outcomes reported in ≥ 2 studies. RESULTS: Among 75 studies evaluating AIS surgery using pedicle screw fixation systems, 46 described rod materials and/or diameters. Two studies directly comparing titanium (Ti) and cobalt-chromium (CoCr) rods found that CoCr rods provided significantly better postoperative kyphosis angle correction vs. Ti rods during a shorter follow-up (0-3 months, MD = - 2.98°, 95% CI - 5.79 to - 0.17°, p = 0.04), and longer follow-up (≥ 24 months, MD = - 3.99°, 95% CI - 6.98 to - 1.00, p = 0.009). Surgical infection varied from 2% (95% CI 1.0-3.0%) for 5.5 mm rods to 4% (95% CI 2.0-7.0%) for 6 mm rods. Reoperation rates were lower with 5.5 mm rods 1% (95% CI 0.0-3.0%) vs. 6 mm rods [6% (95% CI 2.0-9.0%); p = 0.04]. Differences in coronal angle, lumbar lordosis, proximal junctional kyphosis, revisions, and infections did not differ significantly (p > 0.05) among rods of different materials or diameters. CONCLUSION: For AIS, CoCr rods provided better correction of thoracic kyphosis compared to Ti rods. Patients with 5.5 mm rods had fewer reoperations vs. 6.0 and 6.35 mm diameter rods. LEVEL OF EVIDENCE: III.


Assuntos
Cifose , Lordose , Escoliose , Fusão Vertebral , Humanos , Adolescente , Escoliose/cirurgia , Lordose/cirurgia , Titânio , Fusão Vertebral/efeitos adversos , Cifose/cirurgia , Cobalto , Cromo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...