1.
J Cardiovasc Electrophysiol ; 17(9): 992-7, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16948743

RESUMO

BACKGROUND AND OBJECTIVE: Far-field R wave sensing (FFS) in the atrial channel of dual chamber pacemakers is a relevant source for inappropriate mode switch from the DDD mode to the DDI or VDI mode. Inappropriate loss of atrioventricular synchrony due to false positive mode switch is hemodynamically disadvantageous, may induce atrial tachyarrhythmias, can lead to pacemaker syndrome, and impairs the reliability of pacemaker Holter data. The aim of the study was to determine whether individual adjustment of the postventricular atrial blanking period (PVAB) based on an additional test is effective in avoiding inappropriate mode switch due to FFS when compared with standard programming of the PVAB. METHODS: A total of 207 patients were supplied with a St. Jude Medical Identity DR or Identity ADx DR dual chamber pacemaker for sinus nodal disease (n = 84), atrioventricular block (n = 79), binodal disease (n = 35), or other indications (n = 9). At hospital discharge, they were randomized to an individually optimized PVAB (n = 100) or to a control group with the PVAB left at the nominal of 100 msec (n = 107). Primary endpoint was the occurrence of inappropriate mode switch due to FFS within 3 months after pacemaker implantation assessed by stored electrograms of the pacemaker. RESULTS: At the 3-month follow-up, 28/107 (26%) patients with the standard programming of the PVAB showed at least one episode of inappropriate mode switch due to FFS versus 10/100 (10%) patients with optimized PVAB (P < 0.01). The optimized PVAB was shorter than the nominal PVAB in about one-third of patients and longer in about two-third of patients. Different atrial lead localizations were not associated with the occurrence of inappropriate mode switch. CONCLUSIONS: Individual adjustment of the PVAB significantly reduces the incidence of inappropriate mode switch due to FFS.


Assuntos
Estimulação Cardíaca Artificial/normas , Sistema de Condução Cardíaco/fisiologia , Teste de Materiais/normas , Marca-Passo Artificial/normas , Nó Sinoatrial/fisiologia , Idoso , Idoso de 80 Anos ou mais , Arritmia Sinusal/fisiopatologia , Arritmia Sinusal/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Taquicardia/fisiopatologia , Taquicardia/terapia
2.
Pacing Clin Electrophysiol ; 28(7): 620-9, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16008796

RESUMO

BACKGROUND: Pacemaker diagnostic counters are used to guide device programming and patient management. However, these data are susceptible to inappropriate classification of events. The aim of this multicenter study was to evaluate pacemaker diagnostic data using stored intracardiac electrograms (EGMs). METHODS: The study included 351 patients (191 males, aged 71 +/- 10 years) with standard indications for dual-chamber pacemaker implantation. EGM triggers were atrial tachycardia (AT), ventricular tachycardia (VT), sudden bradycardia response (SBR), and pacemaker-mediated tachycardia (PMT). For this study, the devices could store up to 5 EGMs of 8s each (with marker annotation and onset recording). After 3 months, the EGMs were analyzed and classified as "confirmed" if the EGM validated the trigger and as "false positive" if the EGM showed an event different from the trigger. RESULTS: Of the 1,003 EGMs available, the triggers were AT in 640 EGMs, VT in 76, SBR in 105, and PMT in 178 EGMs. Four EGMs were triggered by magnet application. The trigger was confirmed in 614 EGMs (62%): 62% of AT episodes, 18% of VT episodes, 100% of SBR episodes, and 54% of PMT episodes. In 385 cases (45%), the EGMs revealed false-positive events due to far-field sensing (39%), noise and myopotential sensing (26%), sinus tachycardias (21%), double counting (9%), exit block (4%), and undersensing (1%). CONCLUSION: This large-scale study of stored EGMs revealed their value in validating diagnostic counter data. Therapeutic decisions should not be based on diagnostic counters alone; they should be validated by sophisticated tools like stored EGMs.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Marca-Passo Artificial , Idoso , Animais , Bradicardia/diagnóstico , Reações Falso-Positivas , Humanos , Masculino , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Ventricular/diagnóstico