Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Endovasc Ther ; 14(4): 498-505, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17696624

RESUMO

PURPOSE: To evaluate the safety and efficacy of the StarClose device for closure of antegrade punctures following infrainguinal endovascular interventions. METHODS: A retrospective review was conducted of 221 consecutive patients treated with the StarClose device in a 12-month period at 5 centers (4 French and 1 British). Of these, 107 patients (69 men; median age 75 years, range 44-93) were from the UK cohort (111 closures), and 94 patients (75 men; median age 67 years, range 32-95) were from the French cohort (111 closures). Technical success, complication rates, demographic data, medical history, and procedural details were gathered for all patients. Residual bleeding and the requirement for additional manual compression were recorded when the device failed. Clinical evaluation was performed at discharge; color-coded duplex ultrasonography was done in a subset of French patients. RESULTS: The overall technical success rate was 94.6% (210/222; 95% CI 3.1%-9.2%). The results were similar in the 2 cohorts: 95.5% (106/111; 95% CI 1.9%-10.1%) in the UK and 93.7% (104/111; 95% CI 3.1%-12.4%) in France. The 12 failures (5 UK and 7 France) were due to several mechanisms: device failure (n=5), obesity (n=1), groin scarring (n=2), and unexplained (n=4). In 2 failed cases, open surgical closure of the arteriotomy was performed because pressure hemostasis failed. Two pseudoaneurysms were observed: one after immediate failure was successfully treated by prolonged pressure; the other, after apparent success of the device, required surgical therapy. The incidence of serious vascular complication was 1.8% (4/222; 95% CI 0.7%-4.5%); 2 patients from each cohort. CONCLUSION: The StarClose device safely and effectively closes antegrade punctures after infrainguinal endovascular intervention, even in patients who would be considered to be at high risk for puncture-site bleeding. However, a randomized trial would be required to support any definitive recommendations.


Assuntos
Cateterismo Periférico , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Punções/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Inglaterra , Desenho de Equipamento , Segurança de Equipamentos , Feminino , França , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
2.
J Endovasc Ther ; 13(4): 522-6, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16928169

RESUMO

PURPOSE: To report a novel technique for safely closing antegrade common femoral artery (CFA) punctures using the StarClose device after proximal superficial femoral artery (SFA) angioplasty. TECHNIQUE: The vessel locator of the StarClose device should not be deployed within a recently dilated vessel, so after proximal SFA angioplasty, the sheath is withdrawn into the CFA. A second guidewire is inserted into the profunda femoris artery followed by insertion of the StarClose sheath. The vessel locator is deployed in the profunda main stem and withdrawn into the CFA until resistance is felt, indicating apposition to the luminal aspect of the vessel wall. The device is subsequently deployed according to the manufacturer's instructions. CONCLUSION: Use of profunda femoris artery allows safe closure of the CFA using the StarClose device following antegrade puncture for proximal SFA angioplasty.


Assuntos
Angioplastia com Balão/instrumentação , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/terapia , Artéria Femoral/diagnóstico por imagem , Técnicas Hemostáticas/instrumentação , Ligas , Angiografia/instrumentação , Angiografia/métodos , Angioplastia com Balão/métodos , Hemorragia/prevenção & controle , Humanos , Punções
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...